@@binayaksamanta863 Just For Your Information As per Section 3.8 Table 3, the slenderness ratio (KL/r) of compression members shall not exceed 180, and the slenderness ratio (L/r) of tension members shall not exceed 400. You can edit the default values through MAIN and TMAIN parameters, as defined in the design parameters tab I hope this will clear your doubt
Well explained sir👍
Waiting for next part....
@@mohdshoaib5555 thank you 😊 stay tuned Share with others 😁✨
Excellent work Sir❤❤❤
THANK YOU ARNAV YOUR FEEDBACK,THIS MOTIVATE US MORE TO BRING VALUE TO YOUR CONCEPTS STAY TUNED FOR ALL THE UPCOMING CONCEPTUAL LEARNINGS
Thanks sir, waiting for your Next session
Sir it will be more helpful if you also make a video on when to use slenderness ratio 180, 250, 350 and in which members in a steel structure
@@binayaksamanta863 in design parameters everything will be covered
@@binayaksamanta863 Just For Your Information
As per Section 3.8 Table 3, the slenderness ratio (KL/r) of compression members shall not exceed 180, and the slenderness ratio (L/r) of tension members shall not exceed 400.
You can edit the default values through MAIN and TMAIN parameters, as defined in the design parameters tab I hope this will clear your doubt
Thank you so much for such amazing lectures @@CIVILNIRMAN