TIA Portal: External Peripherals / Distributed I/O Hardware Setup

แชร์
ฝัง

ความคิดเห็น • 82

  • @kasivisvanathk1040
    @kasivisvanathk1040 5 ปีที่แล้ว +33

    Even Siemens can't explain like you ! Your really a good teacher ! Thank-you !!!

    • @hegamurl7434
      @hegamurl7434  5 ปีที่แล้ว +1

      Thanks😁

    • @usamashaikh7130
      @usamashaikh7130 2 ปีที่แล้ว

      @@hegamurl7434 really you are great in explaining the concept

  • @BrandanG19
    @BrandanG19 2 ปีที่แล้ว +2

    Got a project dropped on me at work today. Pretty new to Tia portal, this video saved me thank you!

  • @owinookello9358
    @owinookello9358 2 ปีที่แล้ว +2

    this guy is genius i love his teaching so clear big up bro

    • @hegamurl7434
      @hegamurl7434  2 ปีที่แล้ว

      Thanks man!

    • @Manne-st9mr
      @Manne-st9mr ปีที่แล้ว

      @@hegamurl7434 How come u stopped making content ?

  • @firasn.t.5037
    @firasn.t.5037 หลายเดือนก่อน

    Very informative course, well done.

  • @muhannadfakhri
    @muhannadfakhri ปีที่แล้ว +1

    Woooow 🎉 🎉🎉🎉🎉
    Really you are good teacher
    Thanks we appreciate all what you give

  • @ajmalgani1517
    @ajmalgani1517 ปีที่แล้ว

    Best video i never see before

  • @sam8350
    @sam8350 3 ปีที่แล้ว +1

    Thank you for your informative video.. Explanation was really great..
    Here you have used S7-1500 and et200.. I want to know that is communication and programming same for S7-1200 and ET200SP.. Also how about working with normal ethernet (cat-6) cable..

  • @hoangnamnguyen7214
    @hoangnamnguyen7214 4 ปีที่แล้ว

    You are really good teacher. An excellent tutorial.

  • @mohsennekuee9039
    @mohsennekuee9039 3 ปีที่แล้ว

    vielen Dank für ihre Bemühungen

  • @gajendram6462
    @gajendram6462 3 ปีที่แล้ว

    Super sir ..I am always share your videos for learners

  • @azayelcalderon7134
    @azayelcalderon7134 5 ปีที่แล้ว +1

    You are the best!

  • @sarahlabidi6558
    @sarahlabidi6558 11 หลายเดือนก่อน

    You are the best. Thank you!!!

  • @valentino3704
    @valentino3704 3 ปีที่แล้ว

    Thanks. Hegamurl.
    That's helped me in my migration.
    Tumbs UP..

  • @wannabeviralstar
    @wannabeviralstar ปีที่แล้ว

    Hello! Great video, a quick question, if you need to change the configuration of the remote module either by adding a card or changing an analog card input from 2 wire to 4 wire, does this require a whole new hardware download or can it be done without stopping the PLC?

  • @simonmax3901
    @simonmax3901 5 ปีที่แล้ว +2

    That was excellent

  • @tznalcn
    @tznalcn 3 ปีที่แล้ว

    Hey Hega
    Whats could be the point of using only rmodules(upper parts) without lower parts (Inputs and Outputs)
    for ET200 extra modules such as for example Technology ones?

  • @GustavMinnesjord
    @GustavMinnesjord 16 วันที่ผ่านมา

    verry nice

  • @emmanuelkoskei8696
    @emmanuelkoskei8696 4 ปีที่แล้ว

    excellent tutorials , Keep up the great work

  • @dennisrubio2375
    @dennisrubio2375 ปีที่แล้ว

    Master 🧨

  • @denissorto8271
    @denissorto8271 3 ปีที่แล้ว

    How to do a backup of a PLC which include an ET200 in the same net.?
    Thank you so much for share the knowledge.

  • @oogalook
    @oogalook 4 ปีที่แล้ว

    Thanks so much!
    Question: How are your devices connected? Are both your IO device and computer plugged into the "X1" ports of your S1500? Or are all your parts connected to a router or something?

    • @HalfSpec
      @HalfSpec 4 ปีที่แล้ว +2

      I would say yes, that @Hegamurl could do it that way since he's only connecting a computer and the ET200. However, if you wanted to connect a second ET200, you would be out of ports on the particular S1500 he is using. In that instance you'd need a switch. Profinet is compatible with standard ethernet switches as long as the switch is 100mbit or better and full-duplex. That means you can link your computer, PLC, and three ET200s to a $20 5-port netgear switch from Amazon and everything would happily talk to each other. Of course, not all switches are built equal and you probably don't want to use a $20 netgear switch in an industrial application, but hopefully it demonstrates the point :)

    • @oogalook
      @oogalook 4 ปีที่แล้ว +1

      @@HalfSpec Thanks buddy! Good advice!

  • @HIRENECTECH
    @HIRENECTECH 4 ปีที่แล้ว

    Hi, Very well described the point. I would like to know how these all devices connected to each other physically. A simple diagram is just fine for me

  • @shivam5331
    @shivam5331 2 ปีที่แล้ว

    Nice explanation. Thanks

  • @banci1100
    @banci1100 หลายเดือนก่อน

    hello sir! hope you safe and sound..
    want to ask...🙏🙇
    should the CPU to connect the ET200 is S7-1500? how about S7-1200? is it OK?
    thank you, Sir.. hope your day as bright as the Sun🌄

  • @qhawemoyo8940
    @qhawemoyo8940 3 ปีที่แล้ว +1

    Hi, great video. With S7 1215C I know maximum number of signal modules in local rack is 8. When you connect it to ET200 SP does it mean you can add 64 more modules or the 8 is inclusive of distributed IO (i.e total for both local and distributed IO shouldn't exceed 8 signal modules)?

    • @kme8134
      @kme8134 2 ปีที่แล้ว

      I would like to know the same thing. But I think TIA portal will answer this for us. If you can configure many IO devices (more than 8 modules) in Tia, then it should be the same in real life. No?

    • @Qasemzarei
      @Qasemzarei 2 ปีที่แล้ว

      You could address maximum of 1024bytes for input and 1024 bytes for output in 1200 CPUs.
      That means:
      1024 Analog I/O (8bytes)
      or
      1024*8=8192 Digital I/O
      or
      a combination of those which should not exceed 1024bytes.

  • @framos9991
    @framos9991 ปีที่แล้ว

    Thank you!

  • @yarethpellot118
    @yarethpellot118 3 วันที่ผ่านมา

    Question!?
    I have RIO ET200sp
    With a
    DI 16x24v st
    DQ1 6x24vdc/0.5v st
    AI 2xu/i 2-/4-wire HF
    They all have light base
    All connect to power from the same power supply
    My unit connects but the DQ and the AI modules are blinking red lights
    I changed everything physically new stuff so i know the error is my program but i cant find it. Everything matches :(

  • @makenzo2371
    @makenzo2371 2 หลายเดือนก่อน

    👍

  • @mirrorcopy4681
    @mirrorcopy4681 2 ปีที่แล้ว

    thank your so much Bro.

  • @bhushankulkarni1259
    @bhushankulkarni1259 2 ปีที่แล้ว

    It's been really great experience learning Siemens feom your videos.
    Could you please do exactly same video on Profibus DP with some third party devixe using GSD file?

  • @nandarora1303
    @nandarora1303 4 ปีที่แล้ว

    Thanks for making such an informative video.
    In this the i/o addresses of peripheral were automatically given by the plc on downloading. But in case we had already installed one IM and it got faulty and we have to replace it. Now, what if the plc gives some I/O addresses not according to the ones we have already used in the plc program's ladder logic? How can we directly give them addresses before downloading?

  • @mybox6177
    @mybox6177 2 ปีที่แล้ว

    Thank you. Is it possible to make such circuit ring from such IM module. May be a star with switch.

  • @Ana19978
    @Ana19978 2 ปีที่แล้ว

    Thanks!so useful!

  • @Malavaniengineer
    @Malavaniengineer ปีที่แล้ว

    Thank you so much❤

  • @jojoon1937
    @jojoon1937 ปีที่แล้ว

    Please Make a video about s1500 encoder setting using a remote I/O rack and module

  • @LearningTecx
    @LearningTecx ปีที่แล้ว

    Hi what configuration your pc or laptop, Bcoz when I installed TIA portal in laptop is get slowdown in speed. Your's is working very fast, can suggest me the configuration it will helpful for me.
    Thank you

  • @aeon5567
    @aeon5567 2 ปีที่แล้ว

    Um here's a beginner question..
    Is the decentralized/peripheral IO and IO LINK MASTER the same thing

  • @arjanvandekuilen4354
    @arjanvandekuilen4354 4 ปีที่แล้ว

    Hi do you also have tutorials of this subject but then with WLAN communication. My problem is that hardwired I have no problems with recognizing the IO-Device (Sick OLM200) but when I put them on WLAN (Anybus AWB2030) sometimes they are recognized but most of the time not.

  • @johnbiayakadiebwe7121
    @johnbiayakadiebwe7121 4 ปีที่แล้ว +1

    EXCELLENT

  • @JustIce-zv8pk
    @JustIce-zv8pk 5 ปีที่แล้ว

    Great video.
    Thank You

  • @ectromeca8602
    @ectromeca8602 2 ปีที่แล้ว

    very nice video

  • @JinsonKurianVJames
    @JinsonKurianVJames 5 ปีที่แล้ว

    Excellent

  • @mateovelarde2056
    @mateovelarde2056 2 ปีที่แล้ว

    Hi!! Could you explain how to transfer and read data with the instructions DPRD_DAT/ DPRW_DAT ? For array data or structs with boolean data. How to safe them in a DB. How to call each data individually and read them through from a GSD. Thank you for all :D

  • @nomandanish441
    @nomandanish441 2 ปีที่แล้ว

    Thanks

  • @michagoralczyk2140
    @michagoralczyk2140 3 ปีที่แล้ว

    Perfect.

  • @IK-qu9hw
    @IK-qu9hw 5 หลายเดือนก่อน

    I am using 412-5H redundancy system with et 200 sp Im module on profinet communication, but my IM module is not taking IP address what is problem?

  • @manutentoreelettrico647
    @manutentoreelettrico647 3 ปีที่แล้ว

    Thank you Sir!!

  • @AKov0492
    @AKov0492 3 ปีที่แล้ว

    Hello from Ukraine)

  • @saeedmns2227
    @saeedmns2227 6 หลายเดือนก่อน

    Is it possible to simulate ET200 and S7 CPUs in PLCSIM without and physical devices?

  • @dukenuke2690
    @dukenuke2690 5 ปีที่แล้ว +1

    Thank you :)

  • @lollofbb1
    @lollofbb1 5 ปีที่แล้ว

    Thank you PLC god!

    • @hegamurl7434
      @hegamurl7434  5 ปีที่แล้ว

      Now, that's a title I could get used to!

  • @Rob63c
    @Rob63c 4 ปีที่แล้ว

    thanks for all the video's, can you make a video about prodiag thanks.

  • @ahmetmklnc198
    @ahmetmklnc198 3 ปีที่แล้ว

    thanks you....

  • @saeed2tube
    @saeed2tube 5 ปีที่แล้ว +1

    It can add 50 module?
    And why it has memory slot?

    • @hegamurl7434
      @hegamurl7434  5 ปีที่แล้ว +1

      Both good questions!
      The amount of modules you can connect depends on the type of the external I/O... the one I used in the video can have up to 64 Modules (including the Interface module and power modules), so it can grow very big. But different hardware would of course have other modules limits.
      The one I have has a mandatory memory slot, where it saves the module data... without it, it won't run. But again... different modules will have different requirements and most of them don't have a Memory Card Slot

  • @abderaawofshaibi9571
    @abderaawofshaibi9571 2 ปีที่แล้ว

    I would like to communicate with you, I want your help and we could make deal. I have projects and I need your advice. How can I get in touch with you

  • @naveenrawat4339
    @naveenrawat4339 ปีที่แล้ว

    Sir how report created in Tai protal wicc advance

  • @이승훈-x9u
    @이승훈-x9u 4 ปีที่แล้ว

    GOOD

  • @rigelectrician22
    @rigelectrician22 4 ปีที่แล้ว

    Hi,
    Thanks for making these nice and clear videos
    Can you please make a video for below blocks,
    DPRD_DAT, DPDR_DAT, CNT_CTL1
    How this pointer addressing works ???
    P#DB100.DBX0.0 BYTE 4
    What is DBX0.0 and BYTE 4, Why sometime I see BYTE 8 or some others also DBX 50.15 and etc
    I like to communicate with my Wago remote IO's through Profibus
    from CPU317-2 PN/DP. (317-2EK13-0AB0) v2.6.7
    Wago I/O rack
    750-333 coupler
    750-637 encoder
    750-455 AI 4 channel 4-20ma
    750-478 2AI 0-10 vdc
    750-457 4 AI. +-10V
    750-430 8 DI 24v
    757-600 Dummy
    I am just a beginner, started to make a project with siemens hardware and Wago IO's
    I just like to know how you change LADDR, RECORD, when I add or remove input cards ..
    Also ''CNT_CTL1'' for collecting data from Counter card "350-1AH03-0AE0"

  • @sicilykid91
    @sicilykid91 3 ปีที่แล้ว +1

    I keep getting "Error, Error in lower level devices" on all my peripherals

    • @hegamurl7434
      @hegamurl7434  3 ปีที่แล้ว

      You can check the error in your hardware configuration when xou are online. All components have diagnostic capability

  • @karoliczanwojtylanu
    @karoliczanwojtylanu 4 ปีที่แล้ว +2

    Can TIA Portal assign IP adress to ET200 automatically? I can not understand why have you assigned IP adress to this device twice? Coudn't you do it just once?

    • @nikog2243
      @nikog2243 4 ปีที่แล้ว

      also confusing for me. Once it's .144, the other time it's .145...

    • @DeKempster
      @DeKempster 4 ปีที่แล้ว

      You have to set the profinet device name. IP settings are written form the plc.

    • @ksenijadizdar9709
      @ksenijadizdar9709 2 ปีที่แล้ว

      I think this Hegamurl's video should help answer that question: th-cam.com/video/2whkK_jgDOU/w-d-xo.html&ab_channel=Hegamurl

  • @zhengkunyan8001
    @zhengkunyan8001 4 ปีที่แล้ว

    😄,😄😄thank you

  • @mohammedrezk8072
    @mohammedrezk8072 3 ปีที่แล้ว

    The series of ET200 is not organized at all.

  • @saeed2tube
    @saeed2tube 5 ปีที่แล้ว

    I don't know how to thank you.

  • @lamiselhamud3624
    @lamiselhamud3624 3 ปีที่แล้ว

    You are the best. Thank you!!!

  • @Olavotemrazaodenovo
    @Olavotemrazaodenovo 5 ปีที่แล้ว

    Excellent