PAANO I CHECK KAHIT NAKA OFF NA UMIILAW PA RIN (LED BULB)

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ม.ค. 2021
  • #NakaOffnaUmiilawpaRin #LEDbulb
    #Paano i Check Kahit Naka Off na Umiilaw pa Rin.
    #Paano i Check LED Bulb
    #Kahit Naka Off na Umiilaw Pa Rin.
    Sa videong ito ituturo ko sa inyo kong paano i troubleshoot ang ilaw na naka off na umiilaw pa rin..
    kong bago sa channel ko kabayan sana'y wag niyong kalimutang mag like, share, subscribe at pindutin ang notification bell..Maraming Salamat.

ความคิดเห็น • 281

  • @reyelectrical
    @reyelectrical 3 ปีที่แล้ว +1

    Kabayan ganda ng itinuro mo parehas tayo maturo godbless

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Salamat kabayan puntahan ko rin bahay mo at dikitan at kalembangin ang bell..Stay Safe kabayan..

  • @RLC415
    @RLC415 ปีที่แล้ว +3

    Sir palagay kopo ang problema hindi switch..yung pong live wire ay sa terminal ng switch i- connect pag naka Off. yung return wire ay sa kabilang terminal ng switch i- connect na papunta sa terminal ng ilaw i- connect dun sa gitna wag dun sa may thread ng bokilya. Ang naka connect sa terminal sa thread ng bokilya ay yung neutral or ground wire. Ang purpose po kaya wala live wire sa bokilya ng ilaw ay for safety reason. Pag naka Off ang switch walang live wire dun sa parte ng bokilya habang nag rerepair kung sakali. Kaya po may ilaw pa ng konte kahit naka off na ang switch dahil yung live wire mo dumeretso sa ilaw na dapat sa switch lang sya at yung return wire mo ang magiging live wire pag naka On ang switch.

    • @renelauron8393
      @renelauron8393 11 หลายเดือนก่อน

      Tama no problem ang switch kasi gumagana. Yong pag connect niya ay baligtad lang. Live to live, neutral to neutral lines dapat kung basehan ang gamit ng tester. Akala ko nga e test pa niya ang linya ng bombilya kung saan ang live na sinsasabi niya at yong neutral e. Yon ang d nya ginawa, kaya hindi maliwanag ang kanyang paliwanag ngunit ang ilaw naman ay maliwanag 😅 #kulang

  • @espiritulomboy1957
    @espiritulomboy1957 2 ปีที่แล้ว

    Maraming salamat kabayan, awa ng Diyos ay marami akong natutunan, sana ay mapakinabangan ko.

  • @JhemzVtv83
    @JhemzVtv83 3 ปีที่แล้ว

    Master salamat nang Marami sa pag visit nang Bahay ko po.... Kapwa electrician po ito

  • @PauliChromatic
    @PauliChromatic 2 ปีที่แล้ว +4

    Kahit po ba naka off na ang ilaw at naggo glow pa din kahit mahina, nagkokonsumo pa rin po ba yun ng kuryente?

  • @WillieTVhere
    @WillieTVhere 2 ปีที่แล้ว

    Thank you for kabauan nagaluhad kuna kubo mo kabayan kimalimbamg q narin kampana.

  • @buhaycanadachannel8419
    @buhaycanadachannel8419 2 ปีที่แล้ว

    Very informative po salamat sa pagshare👌😍❤️👍

  • @pacificodeluta7507
    @pacificodeluta7507 ปีที่แล้ว

    good job sa troubleshooting demo sir

  • @talentongdodong1903
    @talentongdodong1903 ปีที่แล้ว +1

    Salamat sa turo mo boss, pa wireng nman sa bahay ko boss, para tatakbo, kuryinte na kita, thanks

  • @willycanlas9393
    @willycanlas9393 3 ปีที่แล้ว +1

    salamat Idol sa tutorial 👍

  • @emilyemily8572
    @emilyemily8572 2 ปีที่แล้ว

    Wow ganun pla thnak you po so helpful po

  • @noelsallybataller7941
    @noelsallybataller7941 ปีที่แล้ว +1

    Sana po pag aayos po tau yung sa linya po lamang ng aayusin ang patayin sa breaker dpo ang main kc minsan may gumagamit sa mga outlet at makaistorbo tau sa mga gawain nila. Opinyon ko lang pi.😁

  • @permanentveneracion9094
    @permanentveneracion9094 3 ปีที่แล้ว +1

    Nice 1 kuya cezar

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Slamat sir

    • @mheldseecheverre341
      @mheldseecheverre341 3 ปีที่แล้ว +1

      Sir standard dapat sinunod mo..tama yung unang nakakabit sa swich na live kung line to neutral ang supply..kahit d ka magpatay ng breaker..main pa pinatay eh may nakabranch naman yang sa ilaw at outlet..sana yung cb lng ng ilaw ang pinatay mo..feedback lng po..

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Salamat sa feedback sir ..

  • @gemmaromero4433
    @gemmaromero4433 3 ปีที่แล้ว +7

    Sir pag line to neutral ka dapat yong zero volt ang ilagay mo sa ilaw mo tapos yong hot ilagay mo sa switch.

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว +4

      Magandang umaga ma'am ganun nga yong L2 o neutral galing ng supply diretso sa receptacle at ang Line1 nman o ang hot wire galing supply diretsi nman sa switch para pag nka off switch walang kuryente sa receptacle..Thanks and Stay Safe

    • @jasoninosanto4310
      @jasoninosanto4310 3 ปีที่แล้ว

      @@alekstrisyantv6481 @@

    • @jamesgarbogarbo7599
      @jamesgarbogarbo7599 ปีที่แล้ว

      ndi mo ata naintindihan sinabi ni sir.. ganyan din nmn ibig nyang sabihin

    • @alekstrisyantv6481
      @alekstrisyantv6481  ปีที่แล้ว

      Thank you boss.

  • @cebuelectrician8956
    @cebuelectrician8956 10 หลายเดือนก่อน

    Tama po ya gina gawa nyo sir paki shout out naman dyan

  • @CHLEOMENTETV
    @CHLEOMENTETV 3 ปีที่แล้ว

    Magaling kapatid...comment ko lang po is dapat po breaker na lang ilaw pinatay hnd ung main.. may effect po kc un sa mga appliances like ref and acu.. but overall video is very good! God bless po..

  • @troll210
    @troll210 2 ปีที่แล้ว

    Isa nanamang kaalaman mga kurentisyan

  • @simpliciocamirino2271
    @simpliciocamirino2271 3 ปีที่แล้ว

    Salamat sa pag sharing master.

  • @GhostedStories
    @GhostedStories 2 ปีที่แล้ว

    Maraming salamat bro.

  • @rolandoroncales7992
    @rolandoroncales7992 3 ปีที่แล้ว +7

    Broder hindi yan ground return ang tawag sa isang linya at ang isanaman ay itap sa line two

    • @merlito3319
      @merlito3319 ปีที่แล้ว

      Nagkabalitad lng, kaya tama ka brad.

  • @DaddyBongAngeles
    @DaddyBongAngeles 2 ปีที่แล้ว

    Same problem sa ilaw ko sa room ko boss.. ngayon alam ko na ppaano aayusin. Newbie here boss na pindot ko na master salamat

  • @eclipse5715
    @eclipse5715 2 ปีที่แล้ว

    Thanks for teaching us

  • @arzeevangelista8600
    @arzeevangelista8600 3 ปีที่แล้ว +1

    Sa province kasi yung isang linya lang may hot line kaya talagang mawawala ang konting ilaw nyan baligtarin mo lang ang hot line sa receptacle or yung return sa switch....unlike sa parehas na may volage di talaga yan mawawala ...😁

  • @robertosenga4423
    @robertosenga4423 2 ปีที่แล้ว

    Good job

  • @JunPVlog
    @JunPVlog 3 ปีที่แล้ว +1

    Thank you for sharing sir new supporters here

  • @3232sanisani
    @3232sanisani ปีที่แล้ว

    Sakin line to line nakadim p din kahitvswitch off na...3watts lng ang bulb,,,may konsumo p din ba kaya yun sa kontador? tnx sa sasagot

  • @ronaldpaulraagas8844
    @ronaldpaulraagas8844 2 ปีที่แล้ว +1

    Sir, Line to Ground po ba diyan o Line to Line? Kasi dito sa amin Line to Line. At meron trouble na kahit naka switch OFF ay umiilaw pa rin tatlong ilaw isa switch. Ano kaya posibli trouble? Naka baon ang mga wirings....

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Oo sir line to ground kami dito

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Lagyan mo nlang sir jumper na capacitor 0.1 microfarad 250 or 275 VAC. Sa receptacle mo ilalagay jumper sir

    • @gerrymatu686
      @gerrymatu686 2 ปีที่แล้ว

      @@alekstrisyantv6481 yong tatlong ilaw every receptacle lagyan nang capacitor ? Thanks

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Oo sir ganon na nga

  • @gwardiyaimbentortv
    @gwardiyaimbentortv ปีที่แล้ว

    Sending support

  • @jonathandeboque8781
    @jonathandeboque8781 ปีที่แล้ว +2

    Sir.nagtataka.lng po ako jan paano po.nangyari na ang problema ay switch samantalang ng i-on mo po ang circuit breaker at nakita natin ay may konting ilaw pa e wala pa pong switch na nakakabit? E dba dapat po ay bulb lng ang problema?nagtaka din po ako kc ng gamitan nyo ng test light ung switch ok naman po kc hindi umilaw ung test light sa returm noong naka off, tapos noon pong i-on nyo ang switch umilaw nmn ang test light ng nakatutok sa return.. e di parang wala pong problema sa switch.. paano po mangyari un

    • @alekstrisyantv6481
      @alekstrisyantv6481  ปีที่แล้ว +1

      Switch problema sir kasi madumi na loob ng switch kaya hindi talaga siya totally nag o off. Salamat Sir

    • @jonathandeboque8781
      @jonathandeboque8781 ปีที่แล้ว

      @@alekstrisyantv6481 ah ok po sir salamat po

    • @edwarddelarosa2096
      @edwarddelarosa2096 ปีที่แล้ว

      Sa tingin ko sa led bulb na diperensya

    • @jeffreycordova4447
      @jeffreycordova4447 ปีที่แล้ว +1

      may resistance po. ganyan talaga pag led.

  • @aidadayondon4430
    @aidadayondon4430 2 ปีที่แล้ว

    Nice vid sir, tanong lang po, ano ang dapat kong gawin kapag napasukan ang tubig ulan ang receptacle/ socket ng LED bulb sa aming ceiling. Pwede po bang magsimula ito ng sunog?

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Oo ma'am..una mo gawin dapat ma trace muna kong saan galing tubig kasi delikado nga yan. Salamat

  • @christianjamesedic5184
    @christianjamesedic5184 3 ปีที่แล้ว +1

    wow napaka impormative. Sir tanong ko lang pano po kung 3C ung ilaw ung button bulb sia? kaht naka off na po switch pero nag go glow parin po sia. walan naman pong polarity yung switch diba po? kahit alin wire doon pedeng ikabit? or gayahin ko nalang po yung pano ung wiring nung kung san tinanggal don ko na rin po ibalik ung wire. ganyan ganyan po katulad po nung sa inyo ung problema nung ilaw dto sa bahay. pero pang cieling po cia na tatlong klase ang ilaw pag inoff mo at pag inon mag papalit po sia ng ilaw.. magiging puti, pag inoff mo pag on mo ulit magiging puti, then last po magiging warm na. meron din po siang parang ballast po e

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว +1

      Sir ibalik mo na lang sa dating connection. Mayron kasi na hindi pwede mabaliktad yong supply niya..Sa switch walang problema kasi wala nman polarity yon..salamat sir at stay safe..!

    • @christianjamesedic5184
      @christianjamesedic5184 3 ปีที่แล้ว

      @@alekstrisyantv6481 ok po salamat. bili nalang ako ngbagong switch po baka dahil duon. Try ko po. salamat

    • @spooncr4ft18
      @spooncr4ft18 ปีที่แล้ว

      @@alekstrisyantv6481 hi sir ung ilaw po namin tricor din po.. Tapos po pag nka off na sya may konting ilaw pa din po.. May kunsumo pa din po ba sa kuryente pag ganon?

    • @marygraceartoza4634
      @marygraceartoza4634 ปีที่แล้ว

      Sir SA pagkabit piva Ng may switch pova kailangan ay line1 SA switch at line1 Rin SA receptacles sir at ung line1 pova run dun ung pinaka gitna sirp

    • @alekstrisyantv6481
      @alekstrisyantv6481  ปีที่แล้ว

      Oo sir ganon na nga..

  • @LocalElectricianPH
    @LocalElectricianPH 2 ปีที่แล้ว

    Mahusay master.

  • @rolandobulawan7283
    @rolandobulawan7283 ปีที่แล้ว

    Kabayan db dapat my sariling breaker ung ilaw at ung outlet meaning kanya kanyang breaker para pag my problema ang ilaw ung breaker lang ilaw ang nka off nd madadamay ung iba kc nga ilaw lang ang my problema sa case mo main breaker pa tlg ang inoff mo

  • @onofreleonzon3434
    @onofreleonzon3434 ปีที่แล้ว +1

    Yong switch ay electronic o my pilot light indicator..palitan mo ng hindi electonic..

    • @noelsallybataller7941
      @noelsallybataller7941 ปีที่แล้ว

      Tama po kau sir pag indicator light iilaw at iilaw kahit nkaoff ang switch.

  • @markanthonyemosino3825
    @markanthonyemosino3825 2 ปีที่แล้ว +1

    Sir tanong ko lang po yung single switch po namin ng ilaw nag palit ako. kaya lang di ko alam kung alin yung live at return. pwede ba magkapalit o magkabaligtad yung live at return ng wire sa single switch?

  • @junc1630
    @junc1630 2 หลายเดือนก่อน

    Tanong ko lang po, sir. Yung kaso naman ng ilaw namin tinanggal ko na sa switch pero umiilaw pa din, ano po kaya ang totoong trouble?

  • @Mj-ly8sh
    @Mj-ly8sh 2 ปีที่แล้ว

    Master ask q lang po. Tumulo kc ang ulan sa kisami namin sa Cr dun Banda sa my ilaw. My kaunting tubig s loob ng bulb then kahit Patay cia my glow lumalakas Ang glow tapos hihina. Tanong q lang safe parin ba cia gamitin? Sana mareplayan nio po

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Hindi po safe yon.. palitan niyo nlang bulb or ibilad niyo muna sa araw para matuyo..Salamat Stay Safe Po.

  • @gjrp18
    @gjrp18 3 ปีที่แล้ว +2

    Kung sa switch ang problema pwedeng pagpalitin lang ung wire n nkakabit.

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว +1

      Pwede sir at i check mo na rin ang switch minsan kasi yon ang salarin kahit nka off na may contact pa rin..i check mo gamitan mo ng tester.

  • @rodelcabale1753
    @rodelcabale1753 ปีที่แล้ว

    Una Kong inaalam Jan kung line to neutral o line to line ang supply ng transformer ng Elec. Cooperatives kalimitan sa mga probinsiya line to neutral o kaya sa mga condominium dto sa maynila kalimitan line to line ang supply ng meco.

  • @ronalynmission1986
    @ronalynmission1986 ปีที่แล้ว

    Baliktad sir, neutral ang dumaan sa switch, live ung dumiretso sa kabila ng terminal ng socket

  • @victorvergara8186
    @victorvergara8186 ปีที่แล้ว

    Sir tanong Lang po.pag walang ground ang mga outlet,saan po pwede magkabit Ng ground?o talagang magpapalakad talaga Ng wire hanggang sa breaker?

    • @alekstrisyantv6481
      @alekstrisyantv6481  ปีที่แล้ว

      Oo sir kong lahat lalagyan mo ng ground ang outlet..pero kong isang oitlet lang nman lalagyan mo halimbawa lalagyan mo ng ground ang outlet ng ref. Kuha ka nlang ng wire pulupot mo sa bakal at itusok mo sa lupa..EARTH GROUND sir .Salamat.

  • @markmanaig7635
    @markmanaig7635 หลายเดือนก่อน

    Nilalagyan daw ng 275V 0.1uf capacitor para mawala yung dimmed light.. Dko lang alam san dun ikakabit

  • @renegadeone7837
    @renegadeone7837 2 ปีที่แล้ว

    paano naman kung ung supply sa breaker mismo pag tinest light ay umiilaw dalawang terminal nia, grounded ba boss?

  • @jonathandeboque8781
    @jonathandeboque8781 ปีที่แล้ว

    Sir alex may tanong po ako line to line po jan ang connection o line to ground? Salamat po

  • @gganza
    @gganza ปีที่แล้ว

    Palagay ko may nag off ng switch na basa ang kamay at magkaroon ng ground kaya may konting ilaw o di kaya pa iglap iglap ang ilaw pag natuyo yan mamatay din tuluyan yan. Madalas nangyari sa bathroom switch o di kaya sa kitchen switch namin yan pagpinasok ng konting hamog ang switch.

  • @jericcastillo4286
    @jericcastillo4286 2 ปีที่แล้ว

    Sir alektrisyan.SUBSCRIBER Nyo po ako. Ask ko lang. May 3 different switches ako para sa striplights at pinlights ko. Okay sila dati ng biglang after 2 month.MAY KONTING ILAW SILA KAHIT NAKA OFF. Sabay sabay sila nagka ganon. Switch kaya po problema? O ano po kaya? Maraming salamat po. Pag palain kayo.

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Ah kong different switches sir ..bka sa mga bulb nga kasi may electronics parts sa loob ang mga yan..try mo i disconnect sa mga switch kong mayron pa rin sa bulb nga problema..Salamat Sir

    • @jericcastillo4286
      @jericcastillo4286 2 ปีที่แล้ว

      @@alekstrisyantv6481 dahil kaya sir sa line to line to samin? Khit idisconnect ko sa switch meron pa din?

  • @lizandroituriaga2608
    @lizandroituriaga2608 2 ปีที่แล้ว +1

    boss bakit main breaker kailangan off, dapat yung s lighting breaker lang isolate.

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Sir Wala nman gumagamit kya main nlang off ko..Salamat sir

  • @antoniojrsomera4395
    @antoniojrsomera4395 2 ปีที่แล้ว

    Sir tanung ko lang po.. Pano kung ganyan na case pinatay na ang switch may kunting ilaw padin na mahina.. May consumo po ba yan.. kasi pin light na 10 at yung sa center lamp nailaw padin ng mahina pag naoff na switch.. Malaki po ba consumo pag ganon?

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Mayron sir kunsumo yan konti lang nman..ano supply sa inyo sir line to neutral ba o line to line?

  • @junrinon5600
    @junrinon5600 3 ปีที่แล้ว +1

    Ac Yan kabayan kahit magkabaliktad Yan at Wala sa switch Ang sira...

  • @roviannbernados3726
    @roviannbernados3726 3 ปีที่แล้ว +2

    boss diba sa switch walang neutral return lang nasa taas ang neutral

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Yes sir L1 ang nasa switch yong L2 Neutral direct sa receptacle

    • @bronzonchupalan1494
      @bronzonchupalan1494 3 ปีที่แล้ว

      @@alekstrisyantv6481 sir good day po,ah correct me if I'm wrong, kung ung nsa switch ay line 1 or hot wire, so sana ung return galing switch papunta sa receptacle ay dpat nsa thread ng receptacle pra incase na alisin ung bulb at mahawakan ung thread hindi makuryente pag nka off na ung switch, madami ksi nagkakamali about sa connections.. Godbless po sir..

    • @bronzonchupalan1494
      @bronzonchupalan1494 3 ปีที่แล้ว +1

      @@alekstrisyantv6481 pwede po kung line to neutral connection, ung hot wire nsa off ng switch tpos sa ung return galing switch papunta sa mismong gitna ng receptacle, pra ung thread ng receptacle khit mahawakan ay neutral at wlang kuryente.. Tama po ako sir? Salamat. Godbless

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Wala sir Rovi Ann yong neutral galing ng supply diretso sa receptacle

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Tama ka Sir Bronzon ganon nga ang connection Yong L1 hot wire galing ng supply or breaker connected sa off ng switch at yong return nman connected sa on ng switch papunta sa bronze ng receptacle..at yong l2 neutral nman galing ng supply diretso sa receptacle yong may thread ...Line to Neutral kasi ang supply dito sa amin..Salamat sa feedback sir Stay Safe..

  • @RyanA4011
    @RyanA4011 2 ปีที่แล้ว

    Boss baka pwede po magtanong...
    yung sakin naman kumikislap ung ceiling LED light every 4 seconds... sa switch ba po issue? ung switch kasi may maliit na ilaw para sa gabi makita... hindi ko alam pano ayusin. salamay

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Sir ganito madali pag check kong sira ang switch tanggalin mo common at return wire pagdikitin mo lang direkta at kong kumikislap pa rin bka malapit na mapundi LED light mo..Salamat Sir

  • @gerardovero8621
    @gerardovero8621 ปีที่แล้ว

    Pag gumamit pova nyang testlight nakababa poba dapat ung breaker sir check kopo sana u g outlet na kukuhanan ko para makabbitan kopo ng switch at outlet sir pasagot namn po para malaman kopo kng san ung line1 a tline2?

    • @alekstrisyantv6481
      @alekstrisyantv6481  ปีที่แล้ว

      Sir kong gagamit ka ng testlight dapat may supply nka on ang breaker..pag test mo ng isang linya pag umilaw test light mo yon ang live wire or Line 1..yong line na hindi iilaw pag tinest mo yon nman ang neutra or Line 2

  • @VienVieniceVietriz
    @VienVieniceVietriz 3 ปีที่แล้ว

    possible din kaya ganito din ung sa LED ceiling light nmn ? may mahinang light parin po kase kht naka off salamat po :)

  • @kciredcabayao363
    @kciredcabayao363 3 ปีที่แล้ว

    pinaltan po ng bagong switch o binaligtad lang po ang linya ng switch? salamat po

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Binaliktad at pinalitan na rin ng bagong switch sir..Salamat Sir Stay Safe..

  • @voyagerloftTV
    @voyagerloftTV 3 ปีที่แล้ว

    Thanks for sharing this video sir

  • @eutiquioalforque6519
    @eutiquioalforque6519 2 ปีที่แล้ว

    ipagpalit lang ba ung linya sa receptale at swich sir salamat

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Oo sir kongline to neutral dapat neutral naka direkta sa receptacle..Salamat Sir

  • @jovb143
    @jovb143 2 ปีที่แล้ว

    Anong brand nong dalawang switch pare? Yong before and after sana. We have same problem baka same switch brand din kami.

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว +1

      Parehas brand ng ROYU sir pero yong bagong switch na pinalit ko yong mas malapad na pindutan..Slamat Sir

    • @jovb143
      @jovb143 2 ปีที่แล้ว

      @@alekstrisyantv6481 it’s not applicable pala sa lights namin. I just checked kahit open circuit na, I removed the switch me ilaw pa rin. Cguro I’ll try d solution of adding capacitor as per one of d TH-camrs suggestion. Thanx pare 😊

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว +1

      Line to Line ba supply sa inyo sir..?

    • @jovb143
      @jovb143 2 ปีที่แล้ว

      @@alekstrisyantv6481 L to L = 240v ; L to N = 120V

  • @rianeruiz8292
    @rianeruiz8292 11 หลายเดือนก่อน

    Un bulb po mismo ang bahagyang may ilaw kahit ilipat lipat ko pa sa ibang receptacle

  • @edlongar-tv
    @edlongar-tv 3 ปีที่แล้ว

    Klangan nka line 1 lahat NG connection ppunta sa swicth khit n ito ay line to ground o line to line ang linya Lalo n sa probensya

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Oo sir naka line 1 linya ng swicth ..Salamat Sir

  • @VirgieHutchins
    @VirgieHutchins 4 หลายเดือนก่อน

    Paano kung 3 colors un led light pinalitan na namin un switch ganun pa rin meron parin naiiwan ng konting light ano ang dapat gawin

  • @ezekielmiranda1901
    @ezekielmiranda1901 2 ปีที่แล้ว

    yan lang po dalawa madalas ang problema? wala na po ba iba?

  • @adoinsalejandro2245
    @adoinsalejandro2245 2 ปีที่แล้ว +1

    Problem talaga ng LED lalo na sa line to line 110vac L1 at L2,dyn kasi line to neutral d po ground

    • @jericcastillo4286
      @jericcastillo4286 2 ปีที่แล้ว

      Sir Adoins Ask ko lang. May 3 different switches ako para sa striplights at pinlights ko. Okay sila dati ng biglang after 2 month.MAY KONTING ILAW SILA KAHIT NAKA OFF. Sabay sabay sila nagka ganon. Switch kaya po problema? O ano po kaya? Maraming salamat po. Pag palain kayo.

    • @adoinsalejandro2245
      @adoinsalejandro2245 2 ปีที่แล้ว

      @@jericcastillo4286 try mo sir i measure ang voltage if may tester ka na digital,i off mo muna saka mo i measure,may electronics kasi yan sir

    • @jericcastillo4286
      @jericcastillo4286 2 ปีที่แล้ว

      @@adoinsalejandro2245 pero line to line din sir provider naminm nabasa ko comment nyo na karinawan gnyan s line to line. Kaya naisip ko po. Naisip ko sana paltan lahat ilaw e mahal madami, kya hinayaan ko na lang.

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว +1

      Baka switch sir bka napasukan dumi kaya may contact try mo palitan bago switch..pero posible din bulb tama si sir adonis may electronics parts sa loob niyan..Salamat

  • @trensetter1705
    @trensetter1705 2 ปีที่แล้ว

    *Sir, pano naman po yung ayaw umilaw kahit naka on na po yung switch, yung gamit ko po na switch is para sa ceiling fan, pwede ba yun? chineck kona po yung wiring patungo sa ilaw ok naman.*

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Sunod mo na i check sir kong may supply ..gamit ka ng tester at ingat sir sa pag check ng voltage.

  • @regorgeslani1015
    @regorgeslani1015 2 ปีที่แล้ว

    Pano Naman Po Boss Kung Line to line Na Salamat Po Sa Makasagot

  • @ronalynmission1986
    @ronalynmission1986 ปีที่แล้ว

    Kaya umilaw ung kabilang terminal ng switch,return yon ng live na galing sa ilaw.

  • @josepcortes6625
    @josepcortes6625 3 ปีที่แล้ว

    Gd day sir..Sir pag ganyan ang ilaw may kunsumo po ba yan?slamat po

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว +1

      Mayron sir pero kaunti lang kasi hindi nman nka full yong ilaw..Salamat Sir God Bless.

  • @jessonvanantolihao6827
    @jessonvanantolihao6827 3 ปีที่แล้ว

    naka off na ang breaker wala nang tao ang outlet at ilaw.. pero meron akong isang ilaw sa CR may kuryinte parin umiilaw pag nilalagyan ko nang bumbilya nag trip ang breaker. asking lang kabayan

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Naka off na breaker ..pero may ilaw pa rin ibig sabihin kabayan hindi dumaan ng breaker ang linya ng ilaw mo.
      Kong nag trip kabayan ibig sabihin may shorted linya..Thanks and Stay Safe kabayan.

  • @edisontorres9629
    @edisontorres9629 10 หลายเดือนก่อน

    Anong brand po ng switch yung maayos at yung may leak?

  • @bhorgetrespecio3417
    @bhorgetrespecio3417 2 ปีที่แล้ว

    Hello po sir....napundi yung bulb ng pin tester ko....may nabibili po ba nun....?

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Mayron sir sa mga electronics parts shop..Salamat Sir

  • @andratuttobeneyt1246
    @andratuttobeneyt1246 3 ปีที่แล้ว +1

    Boss pag 3 ung switch tapos isa ang ilaw pwede din b yan?Salamat...

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว +1

      Pwede Sir gagamit ka ng dalawang pirasong 3Way Switch at isang piraso ng 4Way Switch ..yong isang ilaw controlled ng ng tatlong switch sa magkaibang location..Salamat Sir at Stay Safe

    • @andratuttobeneyt1246
      @andratuttobeneyt1246 3 ปีที่แล้ว +1

      Salamat Boss ung ilaw ko kc 3 switch tapos pagnaka off nagbiblink ung bumbilia ginaya ko ung gnawa mo pinagpalit ko ung wire sa ilaw ganun p din ung bang sa gitnang switch boss apat ung wire posible bang nakapalit kc tinangal un nung nagpintura ng bahay,.pare pareho kc kulay ng wire sa gitna.Salamat..

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว +1

      I check mo sir ang unang gawin mo i testing mo ng ibang bulb kong mag blink pa din sa linya ka nman mag concentrate.Slamat sir

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว +1

      Ano ba ang supply sa inyo sir line to line ba or line to neutral

    • @andratuttobeneyt1246
      @andratuttobeneyt1246 3 ปีที่แล้ว

      Boss Pag 18w at 10w ung ilaw hindi naman,.at pag mababa ang watts at saka lalagyan ko ng extension ung bumbilya saka nagbiblink,..dto ko ngaun Boss sa Italia.Salamat..

  • @dwightpagaduan9628
    @dwightpagaduan9628 3 ปีที่แล้ว

    Sir tanong kolang po ganyan din po ang case ng ilaw ko, nag coconduct po parin ba ng electricity pag naka off switch pag ganyan case ? Thanks po in advace

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Oo pero sir pero kaunti lang nman kunsumo niyan ..Salamat Sir Thanks

    • @jericcastillo4286
      @jericcastillo4286 2 ปีที่แล้ว

      Ano ginawa nyo sir dwight? Ganyan din sakin. 3 switch sa pinlight strip light ko.

  • @warrenbacolod376
    @warrenbacolod376 2 ปีที่แล้ว

    Patulong naman po. Nagpalit ako ng smart switch sa sala at dining so 2 capacitor sa dalawang switch. Ang problem ko ang ilaw sa garahe at meron akong 4 na downlight, me isang capacitor na kinabit ko sa line 1 pero nag biblink pa din kahit me 4.5 capacitor na. Ang isang switch 1 ilaw 12w, ang isang switch 3 downlight tig 12w. Need ba tig isang capacitor para di na mag blink?

  • @jairahdiaz1724
    @jairahdiaz1724 ปีที่แล้ว

    Paano f line to line Ang liny egnunprin Ang ngyayari nakadim prin kht naka off

  • @bernardoquarteros6371
    @bernardoquarteros6371 3 ปีที่แล้ว

    Ingatan Nawa NG Dios

  • @jessonvanantolihao6827
    @jessonvanantolihao6827 3 ปีที่แล้ว

    kabayan may tanong ako. pwede bah

  • @noelhembrador1298
    @noelhembrador1298 ปีที่แล้ว

    Ganyan din sken palitan mo ng bumbilya kasi emergency bulb yan ganyan din ako dami ko kinalikot ung bulb sinubukan ko

  • @therandomcarpenter6810
    @therandomcarpenter6810 ปีที่แล้ว

    Kabayan may tanung ako ,ilan mm ang binubutasan sa kisame para sa pin light ?

    • @alekstrisyantv6481
      @alekstrisyantv6481  ปีที่แล้ว

      Kong ilang piraso ang pin light kabayan ganon din ang butas sa kisame..halimbawa apat na pin light apat na butas din..Salamat

    • @therandomcarpenter6810
      @therandomcarpenter6810 ปีที่แล้ว

      @@alekstrisyantv6481 hindi ang size butas kabayan

    • @alekstrisyantv6481
      @alekstrisyantv6481  ปีที่แล้ว

      Ah ok kabayan ..yan pin light ang gagamitin mo na guide kong gaano kalaki ang butas kabayan idikit mo sa kisame saka mo guhitan ng lapis..

    • @therandomcarpenter6810
      @therandomcarpenter6810 ปีที่แล้ว

      Sir balak ko kasi bumiling hole saw pang pin light ,anong size sir ang dapat

    • @alekstrisyantv6481
      @alekstrisyantv6481  ปีที่แล้ว

      Yong bilhin mo kabayan isang set. ibat ibang size ng butas..para sa lahat ng pin light..salamat

  • @bennyjulyvales1683
    @bennyjulyvales1683 2 ปีที่แล้ว

    yung ginamit nu po na testlight ay pareho lng sa test light ng motorsiklo?

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Hindi pang motor test light ko sir 110 - 700 volts kaya niyan..Salamat Sir

    • @bennyjulyvales1683
      @bennyjulyvales1683 2 ปีที่แล้ว

      @@alekstrisyantv6481 maari kpo bang mahinge nem ng test light na nabile mo boss at magkano ? ty boss

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Mura lang ito sir 60 pesos lang sa mga hardware.

    • @bennyjulyvales1683
      @bennyjulyvales1683 2 ปีที่แล้ว

      @@alekstrisyantv6481 sir pd malaman nem ng gamit mo pang testlight po.cencia npo dkpo kc linya ito nagkaroon lng ako ng kunting idea sa mga napanood k mga vedeo mo sir,slamat advance po

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Sir sorry nkalimutan ko brand ng test light ko onboard kasi ako sa barko ngayon..

  • @raulsayosamorris2451
    @raulsayosamorris2451 10 หลายเดือนก่อน

    Bro return at line 2 ang nasa ilaw,wala pong ground

  • @junmagtulis7585
    @junmagtulis7585 3 ปีที่แล้ว

    boss paano pag line line ang supply

  • @donaldaseberos2595
    @donaldaseberos2595 ปีที่แล้ว

    Paano po pag line to line Ang supply

  • @nelsonlacson1551
    @nelsonlacson1551 3 ปีที่แล้ว

    Hoy kabayan dito sminsa cavite line to line ano gagawin mo

  • @sherwinbadilla6775
    @sherwinbadilla6775 3 ปีที่แล้ว

    Sir tanong kolang sir dito sa amin sir sa davao line to line sir bakit pag off k Ang switch k sa strip lights k may ilaw parin sir ano gawin ko sir pa help sir

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Pag ganyan sir lagyan mo ng switch yong dalawang linya..L1 at L2

  • @walterdeleon9233
    @walterdeleon9233 2 ปีที่แล้ว

    applicable po ba yan sa 3way switch?

  • @efrenbabaran5837
    @efrenbabaran5837 2 ปีที่แล้ว

    bakit s ibang Led. walang umilang. ung isang led lng may Ilaw?

  • @teammarktv
    @teammarktv 2 ปีที่แล้ว

    kumukunsumo parin po ba sya kahit naka off?

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Oo sir pero kaunti lang ..para ka lang nagchacharge ng cp sa kunsumo..Salamat sir

  • @archiecab1766
    @archiecab1766 2 ปีที่แล้ว

    New subscriber here. Payakap naman idol.

  • @ramonroxas2072
    @ramonroxas2072 2 ปีที่แล้ว

    Sabi mo noong una, ok ang switch. Tapos sa huli sabi mo, switch ang problema. Alin ba talaga.

  • @JesArts35
    @JesArts35 3 ปีที่แล้ว

    Sir paano po sa led lights sa motor, kahit walang ground nailaw siya

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Sir yong positive supply doon mo ilagay ang switch..Salamat sir

  • @bongpogi6429
    @bongpogi6429 2 ปีที่แล้ว

    Bakit ka nag switch off sa main breaker dapat sa breaker or branches ng ilaw breaker at hindi yan Line to nuetral. Line to line yan brad.

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Line to Neutral sir main wala nman gumagamit wala yong may ari kaya main nlang off ko..Salamat Sir

  • @AnthonyBugaoan
    @AnthonyBugaoan 11 หลายเดือนก่อน

    Parang mali talaga ung pinagbqliktqd mo pa ung sa receptacle😂

  • @roadfieldtv2686
    @roadfieldtv2686 3 ปีที่แล้ว

    New friend po.. bisita karin sa bahay ko

  • @coisapinoso6999
    @coisapinoso6999 3 ปีที่แล้ว

    Ganto din yung ilaw namin. Delikado po ba ito?

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Hindi nman delikado sir pero dapat pag naka off dapat wala talagang ilaw..Salamat Sir

    • @regorgeslani1015
      @regorgeslani1015 2 ปีที่แล้ว

      Pano Naman Boss Kung Line to Line Pasagot Naman Po

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      L1 Sir ang naka direct sa Switch ..Thank You

  • @rerereckachchow
    @rerereckachchow 3 ปีที่แล้ว

    Pano po kaya sa strip lights naka switch off naman pero may dim light pa din cya. Sa gabi mapapansin kasi ung glow talaga.

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Neutral dapat sir ang nka direct sa strip lights ...Thanks

    • @francelflores9606
      @francelflores9606 2 ปีที่แล้ว

      Panu nmn po kung hindi nmn line to nuetral pero may grounded pdn kahit nka off may ilaw pdn na 110. Line to line po.

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Line 1 ang i direct mo sa switch..Salamt

  • @jovelasco9990
    @jovelasco9990 2 ปีที่แล้ว

    Sir,paano ba i fix ang single switch na ang ilaw ay naka on kahit nasa off position?

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Sir kong line to ground ang supply ...line 1 i direct mo sa receptacle..i check mo din switch sir baka sira na rin..Salamat Sir

  • @arlenemontilla8504
    @arlenemontilla8504 3 ปีที่แล้ว

    Sir pwd po b mka hingi ng tulong ask ko lang po bakit po khit mg fully paid po ako a bill ko lagi pong my naiiwan na pervious n bill,isa pa po bkit po sobrang laki ng bill n halos wla nman.po kming appliances ilaw elevtric fan at computer lang po,n compare ko lang bakit po yun kapit bahay ko n.halos kumpleto s appliances my aircon p mababa lang po yun bill nila my sarili po akong metro 3 months p lang po kmi nkkalipat.Sana po mbigyan nyo ng ksagutan.ang.oroblema ko.

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว +2

      Ma'am sa mga service provider kasi ma'am kahit isang buwan ka na hindi gumamit ng kuryente may babayaran ka na minimum bill..Pero Sabi mo sobrang laki ng binabayaran mo kahit kaunti ginagamit mo na appliances mas maganda ma'am ipa check mo metro mo bka may problema na at ipa check mo rin ang linya mo mula poste hanggang loob ng bahay mo. Salamat ma'am Stay Safe

    • @PauliChromatic
      @PauliChromatic 2 ปีที่แล้ว

      Baka po napaka taas ng wattage ng ilaw na ginagamit niyo pwede po yun sa ganon.

    • @rauldeguia8874
      @rauldeguia8874 2 ปีที่แล้ว +1

      Grounded yung linya mo.

  • @jayrtagumase4935
    @jayrtagumase4935 3 ปีที่แล้ว +1

    paano po kapag line to line. pero umiilaw parin ang led bulb

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Sir isang beses palang ako nka pag wiring jan sa maynila ang connection ko L1 diretso sa receptacle at ang L2 sa mga switch..at mga led rin ginamit wala nman problema sa bahay ng Pinsan ko..ito kasi na trouble ilang beses ko na na experience pag ang supply ay Line to Neautral..Salamat sir sa feedback..Stay Safe

    • @jayrtagumase4935
      @jayrtagumase4935 3 ปีที่แล้ว +1

      slamat sir

  • @rauldeguia8874
    @rauldeguia8874 2 ปีที่แล้ว

    Parang di puwede yung switch na may indicator na ilaw para
    sa mga LED na ilaw.

  • @mikepasaway416
    @mikepasaway416 3 ปีที่แล้ว +1

    Sir pano kung parehong live ung line one at line 2..

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Kong katulad jan sa maynila Sir Line To Line ang supply L2 ang i connect mo sa switch.Salamat sir sa feedback

    • @mikepasaway416
      @mikepasaway416 3 ปีที่แล้ว +2

      @@alekstrisyantv6481 parehas sir ang boltahe ng line 0ne at saka line two eh...di kya sa production ng led ang my error..

    • @alekstrisyantv6481
      @alekstrisyantv6481  3 ปีที่แล้ว

      Subukan mo sir ng ibang led para sigurado ka..

    • @rickmantv6012
      @rickmantv6012 3 ปีที่แล้ว +1

      Sa led yan may error..kasi sa maynila .line1 line2..110..+110..di kagaya sa probinsya..0+220..Line1 is 0earth ground neutral niya..Line2 hot 220..

    • @rickmantv6012
      @rickmantv6012 3 ปีที่แล้ว +1

      Sa maynila tatlo ang wire.isang walang balut.. dalawang ang may balut..kaya understood na dalawa ang may kuryente..Line1 at Line2...Yong Walang balut na wire..makagawa ka dun ng 110 source..kasi 0 yon.at saka pwede Rin protection yon sa grounding system..para maiwasan ang may makuryente..

  • @thomas_shelby106
    @thomas_shelby106 2 ปีที่แล้ว

    sir ano pong tawag dun sa bagong switch na ipinalit mo?

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      1 GANG switch sir..Salamat sir

    • @thomas_shelby106
      @thomas_shelby106 2 ปีที่แล้ว

      @@alekstrisyantv6481 salamat po, sana maayos ko ang led light namin, susundan ko lang po ang ginawa mo. salamat sir.

    • @alekstrisyantv6481
      @alekstrisyantv6481  2 ปีที่แล้ว

      Welcome Sir