Hello bhai ji video apki bahot detailing me hai acchi hai Mera apse sawaal h ki mera geyser hai 6ltr ka oster company ka kareeb 4 saal purana usme water drain ki problem aa rahi open kiya or service bhi ki but thik nhi hua leakage ke kya kaaran ho sakte kripiya bataya Thanks
TECH TO TECH Leakage nichey se ho rahi hai jaha connection wire box cover laga hota h waha per se paani nikal raha h geyser off ho chahe on paani nikalta reha h or agar me water inlet supply band kar du to band ho jata h
Bhai apne gyser ke baremein acha samjaye saab maine gyser kola maine magar pani leek hora aur current mein lagaye tho current on nahi hora saab auto cut aur jo aur ek hai oh pani legetho shot hota saab plz reply me thnk u
Hello , I have koryo 25L gyser. I have opened it. I have Cleaned the element . Tank has lot of scaling. Is it required to remove the tank and clean or I can use some chemical to clean the tank. Or please guide how to clean the tank.
Inlet vali tooti mein paani bohot kam ata hai.toh geyser bhi slow deta hai paani. 3rd floor par tanki hai.. Baki saare nalo mein paani tez pressure hai.. But voi geyser vale toti mein kam hai.. Plumber kehte hai saare bathroom ki pipe badal do.. Electrician kehta hai- geyser badal do.. Kya kiya jaaye kuch samajh nahi aata. Please help
Brother my house heater is not working. I removed geyser assembly. Element damaged. Another one pressure relief valve damaged. There have one pvc tube fixing that one down side.this problems how to solve. Please explain next video. My water heater 10ltr.vijai.
@@techindia7hunar ha brother check kia tha bina valve ke saath in let lagake check kia pressure out put acha tha, valve ke saath sirf water pressure acha tha, jab valve lagane se out ka pressure kum horahata.
Sir mere electrical gyer me bar bar air aajati hai to kya karu ek bar air nikal ke chalu karne par pani complate aata hai magar jab pani ka nal bandh karta hu to vapis air aajati hai please kych sollution de
Bahot bahot shukriya sir ...ab pani aa rha hai ..balti me koi diikat nhi lekin shower me thoda pressure kam hai lekin kam chal jata hai...bahot Dino ki problem apne solve kar di.. shukriya
भाई मेरी water Tanki aur aur geyser ke bich mein Main lagbhag 2 fit ka Antar hai jisse geyser mein bilkul bhi pressure Nahin ban raha hai kripya bataen ki kya Samadhan ho sakta hai
Bhai sahab,,panch chhe din se gejar main khara pani use ho rha hai,gejar chlate hi awaj bahut krne lga hai aur pani bhi lal rang ka (jang wala) aa rha hai,,,hum gejar ko 15 mint chla kr bnd kr dete hain ke kahi kuchh jyada garbar na ho jaye,,koi hall btaye kirpya
Mene 1ltr geyser ki new coil fitting kiya hu lekin usme pani garam hote same cutoff hone se kuch der pahele pani garam hone ki awaz aarahi hai kya problem ho sakti hai ab mujhe kya karna chahiye plzz bataiye
@@techindia7hunar Haa me yahi puchna chahta hu ke 1 ltr capacity wala geyser pani garam karte samay awaz karta hai kya kyu ke mene new coil fit kiya hu abhi or 10 din baad awaz aane shuru hogai
@@techindia7hunar Ye 1ltr wala geyser mene ek dost se liya hu coil short thi to mene khud change kar liya isliye mujhe pata nahi pahele isme awaz aati thi ya nahi
bahut khoob cleaning job.
I like your video, though I not a plumber, what you have said is universal and applicable in all job and business,, good....
Appropriate information with all the details ...carry on
Very useful video
good job sir
Very HONEST Person to clear all matter.THANKS A LOT.
Thanks
Accha samjhaye sir good
Very Nice Good Job 👍
आपने बहुत अच्छी जानकारी दी दिल से धन्यवाद
Thank you brother. Very helpful video 🙏
Bahut vanity dhanyawad
Nicely explained,i fully appreciate
Thanks
@@techindia7hunar hi
Snd no .
Useful vedio
Bohat achi video banai aapne
Sir aap muje aapna number send kar sakte ho
Jabardast parfomens ky shandar samjhya
thanks
excellent instructions to remedy scale build up
Thanks
Nicely explined. Tks
Ok sir bilkul samaj gai sar .thanks sir.
Please make one video of parrywere geyser 10litter. Wonderful videos I have seen, thanks.
Good video bhai
Thank you very much
Okokok
Sir aapne bohat ache se samjaya
Thanks a lot
Weldone
Good emfomathion. Sir
Thanks
Hello bhai ji video apki bahot detailing me hai acchi hai
Mera apse sawaal h ki mera geyser hai 6ltr ka oster company ka kareeb 4 saal purana usme water drain ki problem aa rahi open kiya or service bhi ki but thik nhi hua leakage ke kya kaaran ho sakte kripiya bataya
Thanks
Leakage kaha se hai bo batao Phele 🙏🙏🙏🙏
TECH TO TECH
Leakage nichey se ho rahi hai jaha connection wire box cover laga hota h waha per se paani nikal raha h geyser off ho chahe on paani nikalta reha h or agar me water inlet supply band kar du to band ho jata h
Vosser change kar do agar Vosser se Nahi hai to tank me hogi tank me gas welding Kara do Aapka giger sahi ho jaye ga 🙏🙏
TECH TO TECH
Thanks 😊 I
bht achha
Bhai apne gyser ke baremein acha samjaye saab maine gyser kola maine magar pani leek hora aur current mein lagaye tho current on nahi hora saab auto cut aur jo aur ek hai oh pani legetho shot hota saab plz reply me thnk u
auto cut ka batan daba do on ho jayega aur connection chak kar lo sahi se
Ok bhai saab thnk u
Thanks sir g
Hi what to do and could b reason if water leakage from top side where rubber ring is there in body joint. Drop drop water dripping.please guide
thank U sir ji
Baqi koi dikkat nahin hai bas paany geezer men bher jaane k bad auto cut nahin hota bhar k uuper kahin se leek ya overflow hone lagta hai
aap ke geyser ka tank likij hai pani auto cute nahi hota hai
Use wire or acid to clean
Bhai acid se to kabhi bhi clean karne ki kosis mat karna tank gal jayga Aur pipe bhi gal jayga
Mere pass bajaj ka majesty 25 leter wala hai ....osmen paany bharne I bad bhi auto band nahin hota
Majesty ???
Sir isko hum acid se clean kr skte hai??? Pls sir reply karna
Asid se Nahi garm karke kardo
Plz
Hello , I have koryo 25L gyser. I have opened it. I have Cleaned the element . Tank has lot of scaling. Is it required to remove the tank and clean or I can use some chemical to clean the tank. Or please guide how to clean the tank.
Nahi tank calaen karne ki koi jarurat nahi hai
Aur hamare gyser ki inlet and outlet separetely hai. Matlab element ki assembly ke sath nahi...
@@adityasathaye8968 koi dekkat nahi hai
Element or terminal ko khole bina b to assembly nikal sakte hai hum ya jrruri hai kholna.
Koi jaruri nahi hai ase bhi nikal sakte hai
5kg staplizer ki reley kese change karne hai video banay
Reley me kya huaa hai
Mera geyser 2 saal purana hai.. Bajaj cadalia 15 liter Paani bohut kam ata hai.. Is video wale geyser se bhi kam...
Har geyser ko aise hi kholte hai?
Ha jadatar esi Tarah se kholte hai
Havelis ka turbo dx model servicing dikhaye please..
Same process
Bhai geser ka non return valve change keya hai ab Pani out ni ho rha
Sir agr geyzer ko hum Ghar me Khud khol le to band karny ke bad leak to nai hoga
En let ka paip bich me se thoda kana (hoal)ho gaya he ab kya kare
Thankxxz
पवार लाइट नही जल रही सायद वायर गलत जुड़ गए थ्री पिन में
Ya tharmocute cute hai
Indicator connection samjhao
th-cam.com/video/RoecDK1vfmk/w-d-xo.htmlsi=dA-_X3xKHHYgVbvb
Sir ji jaksan box cansilad box or dip box me aelidi lagana bataye or kitne wot ki h. Reply
LED lagana bahut hi asan hai aap LED light kharido ge to aap ko pata chal jayega kaise lagate hai
Inlet vali tooti mein paani bohot kam ata hai.toh geyser bhi slow deta hai paani. 3rd floor par tanki hai.. Baki saare nalo mein paani tez pressure hai.. But voi geyser vale toti mein kam hai.. Plumber kehte hai saare bathroom ki pipe badal do.. Electrician kehta hai- geyser badal do.. Kya kiya jaaye kuch samajh nahi aata. Please help
Inlet wala volve khol kar dekh Lo kuchh fas gaya hoga
Water pipe bilkul saf kr diya
In let chake Karo Kitna flow hai
Brother my house heater is not working. I removed geyser assembly. Element damaged. Another one pressure relief valve damaged. There have one pvc tube fixing that one down side.this problems how to solve. Please explain next video. My water heater 10ltr.vijai.
@@muruganmurugan1706 element change kar do
@@techindia7hunar element change ogaya. Dusra relief valve ka problem. Assembly plate me rethana o wala. Usme pvc tube lagayauna. Oiye
Geyser se auto cut nikal kar chala sakte hain
Thank you sir ji
Usko kaise banaya jayega
Sir mene khaitan ka 25 ltr ka new geeser lgya hai 3 din ho gye .geezer tap me paani bhut kam ata hai or phir bnd ho jata hai .kya soultion hai eska
Sir l have snowline 15 litre capacity elec water geyser. The cut out is out of order.pl.let me know how can l repair it at home with demo.in Hindi
please change to thermostat
सर आउटलेट पाइप अंदर से टूट के छोटा हो गया है तो क्या उसके बाद भी वो पहले जैसा काम करेगा ..???
please change New pipe welding shop
Brother Naya havells quatro 10 liters liyata 1 afthe phela out ka garam pani pressure bahut kham aarahahai kya karna kuch suggestion dena
In let me pressure kitna hai bo dekho Pehele
@@techindia7hunar ha brother check kia tha bina valve ke saath in let lagake check kia pressure out put acha tha, valve ke saath sirf water pressure acha tha, jab valve lagane se out ka pressure kum horahata.
@@sripal6291 kon se volve ki baat kar rahe ho angal volve ki
@@techindia7hunar haa bhai,
Earthing kaise karneka
gryser ki boddy me laga do
Hi
Hello
भाई भरे गीज़र में तो बहुत वजन होता है । कैसे उतारना होगा।
Pahle uska elements khol do Pani nikal jayega
Agar customer hi reparing kar lege to ham sab mecanic apna pakad k hilayege kya
Nice comments
Instant geezr main pani kaisy fast hota agr left main pani kam ho to
Gas geezr
Sir inlet pipe jod sai hi tank k andar sai hi tut gyi hai ab kiya kre ice hmara geyzer krab hoga k nhi
Ek Steel ka pipe welding kara do dusre ke bata bar
Sir agar inlet pipe jod seh hi tut gyi hai kiya kre
Hello sir, is geyser mein jo inlet pipe mein jo already valve hota hai uska kya naam hota hai aur uska kya kaam hai sir please jaldi bataye
uska kam hai pani wapas jane se rokana aur bo khrab hai to usko nikal do
Sir geyser ka servicing karaya hai. Inlet se bhi hot water back kar main pvc pipe ko gala diya hai. Kaise thik hoga
Tamprchar kam kar ho
Bhai geser kharab hai chal Bhai thik hai kam kam makenic ka naam to mat lo sarkar
❤ es ka material kaha milta h
Tilak Nagar new delhi
Ghalti se installation k Tim inlet ki jgah out aur out ki jgah in lgane se kya hoga
Koi fark Nahi padta 🙏🙏🙏
कृपया हमें बताइए
हीटिंग रॉड के किसी भी टर्मिनल पर न्यूट्रल या फेज लगा सकते हैं या नहीं? हीटिंग रॉड में कोई प्लस या माइनस तो नहीं होता है?
th-cam.com/video/RoecDK1vfmk/w-d-xo.html esko dekh lo samjhh aa jayga
Sir isme out let kaat kar seedha kiya hai aapne out let ko saaf karte hue video nahi banai
Shaf karne ka sam tarika hai
Bahar se agar karigar bulaye to kitne paise dene chahiye sir
200
Air pipe kis lay drops attay hay
sefty bolve leeke hai
Sir ji geyser ka ya bate display on fir v water warm nhi ho rha hai
Kat jaldi kartha ha
Geyser 6 saal kA ho gya hai, kya Ab change kar Dena chaiheye
Kya problem hai GEYSER me
@@techindia7hunar heating element bar bar खराब हो रहा है
@@jagjeetpratapsingh7227 kitne me jal jata hai
Jab tak k connection pipe band na kare khud se
Kiya Karan hai ?
Usha misty 15 लीटर गीजर मैं गर्म पानी कम आ रहा है उसे कैसे ठीक करें
Kitna purana hai
Bhai tune input pipe ka bend kata galat kyon karte ho company ne soch kar hibend diya hai
Bhai bo band paani ki mix karne ke liye hai Aur Koi kam Nahi hota hai us band ka
Sir mere electrical gyer me bar bar air aajati hai to kya karu ek bar air nikal ke chalu karne par pani complate aata hai magar jab pani ka nal bandh karta hu to vapis air aajati hai please kych sollution de
Thodi hearing kam kar d0 tharmostet se
Ye salt kitchen le leja aur khana me dal
Nice 😂
hello bhai, geyser me jo thermostat ka switch hota hai aur dusra jisme reset ka button hota hai wo explain karo.. hamare pas bajaj shakti plus hai.
Reset Bala tharmocut hai
Aur muze shower k liye use karna hai to kya pressure kam ayega?
shower me to mix paani use karte hai
@@techindia7hunar ha lekin mix me pressure ka koi problem to nhi ayega na wo bend wala hissa todne k bad ,
@@manojsuryawanshi1546 kat do koi parolem nahi hogi
@@techindia7hunar thanks
Bahot bahot shukriya sir ...ab pani aa rha hai ..balti me koi diikat nhi lekin shower me thoda pressure kam hai lekin kam chal jata hai...bahot Dino ki problem apne solve kar di.. shukriya
New geyser fit kiya hai green light nhi aarahi or pani garam nhi horaha hai kya karna hoga
Cannetion dekho geyser ke
Top galt na laga deya ho
Sahi dhang se
Yeh Dekh lo th-cam.com/video/RoecDK1vfmk/w-d-xo.html
Agar element shirt Ho Jaaye to kya current lag sakta hai
Ha current lag sakta hai Aur paani bhi garm Nahi hoga
Current Na Lage iske liye kya karna chahie
@@shabraizhussain3005 geyser me earthing laga do tab current Nahi lage ga earth Chalo hona chahiy
भाई मेरी water Tanki aur aur geyser ke bich mein Main lagbhag 2 fit ka Antar hai jisse geyser mein bilkul bhi pressure Nahin ban raha hai kripya bataen ki kya Samadhan ho sakta hai
geygser kitna purana hai
@@techindia7hunar 6 month
@@SUDHIRKUMAR-1448 aap pvc canection ka bosser block ho gaya hoga
Sir mera to naya gyser he aur uska pressure to bilkul nahi deta he.
In let pipe me paresar chak Karo Thanda pipe me
Bhai sahab,,panch chhe din se gejar main khara pani use ho rha hai,gejar chlate hi awaj bahut krne lga hai aur pani bhi lal rang ka (jang wala) aa rha hai,,,hum gejar ko 15 mint chla kr bnd kr dete hain ke kahi kuchh jyada garbar na ho jaye,,koi hall btaye kirpya
app ne geyger new(nyaa) lagahai kya
@@techindia7hunar 15sal purana hai ji
@@kamaljitdhillon4746 to aap ke geyger ka element kharab ho gaya hai es ko change kar do
@@techindia7hunar ji ok,,thank you
Mene 1ltr geyser ki new coil fitting kiya hu lekin usme pani garam hote same cutoff hone se kuch der pahele pani garam hone ki awaz aarahi hai kya problem ho sakti hai ab mujhe kya karna chahiye plzz bataiye
ek litar paani thoda hota hai es liye bo jada se jada 3 litar hi paani garm karega aur chhote geyser me abaaj to aati hi hai
@@techindia7hunar
Haa me yahi puchna chahta hu ke 1 ltr capacity wala geyser pani garam karte samay awaz karta hai kya
kyu ke mene new coil fit kiya hu abhi or 10 din baad awaz aane shuru hogai
kyu ke mere pas 3 ltr capacity wala bhi geyser hai lekin ye pani garam hote samay awaz nahi karta
@@altafshaikh3771 pahle bhi abaj aati thii kya aur uska tmp 65, par kar do
@@techindia7hunar
Ye 1ltr wala geyser mene ek dost se liya hu coil short thi to mene khud change kar liya isliye mujhe pata nahi pahele isme awaz aati thi ya nahi
Sir water ka flow slow hai
th-cam.com/video/03-P3m6cJLg/w-d-xo.html this video watch
Kitney saal purana gyser hai ye bhai ji
Bhai sahab giger ki service 2 saal me ho honi chahiy jamin ke paani bala giger ki 🙏🙏🙏🙏
Ye giger 4 saal Purana hai
@@techindia7hunar acha...hamare gyser mei outlet mei panni ka pressure kum Q aa rha hai.plz btaye...
Phele inlet ka presser chaik Karo kitna preser hai
Pressure tu thek hai nrb ko lagana jaruri hai..usse k karan problem ho rhi hai
Voice is not good its difficult to hear
Assembly kab change karna chahiye
Jab assembly ki pipe elements se niche se gal , tut gayi ho tab assembly change Karni chahiye
Aur jab geyger me pani stor na ho tab bhi assembly change Karni chahiye
Sir inlet se gens kese nilti.... Kya krn h ..
Geyser ka element kyu fat taa hai...reason..Please rply
Khara (Namak ka pani)
Bhai safai karne ke baad bhi pani ka pressure nahi aa raha kya karu
Assembly change kr de bai