My meters acc starts with 144 they were installed by kplc this year, they have connection problems when loading token.They always displays 'failed' what could be the problem? kindly assist.
This is how to troubleshoot: First, make sure the MCU is ON, In the Consumer Unit all MCB circuit breakers including the Double pole isolator must be ON. The CIU batteries Must be in good condition, inside your house plug in your CIU in the power Socket outlet and Switch it ON. You can load your token without hustle or stains. To understand better check out this TH-cam video th-cam.com/video/gsNAaCb9t_U/w-d-xo.html
My smart meter its having a problem with the ciu keypad when pressed a certain number it jump to another digit so am un able to load token any idea to restart the ciu.
Hi, it taken like three months without loading token, now i've purchased to load in but unfortunately when i fix it on the socket and key in the codes then enter it just reads 000, what could be the problem?
Weuh hii yangu inakunywa token kama wa munyota show me how I can see instantenous power consumption (load) cause tell me why tulilala saa sita ikiwa 1.89, Right now its at 0.88 and I bought juzi 5 units in the morning na nikatoka
Hey, guys [Electricians, Electrical students, and Utility Customers. This is a special video regarding the ACTIVATION of the SMART METER TECHNOLOGY Prepaid Energy Meter Model 2023, Kindly Watch this video, Like, Comment, and support us by SUBSCRIBING to this channel. Where you don`t understand Feel free to ask all questions below, in the comment section or reach us on WhatsApp wa.me/c/254754879439. You can watch a full video on how to INSTALL and activate Clou & Smart meter Technology by clicking this link. th-cam.com/video/ZN6dG2L86Vk/w-d-xo.html
My meter starts with 92..... It was successfully activated and commissoined but after 1 month of working well, the power supply suddenly stopped! Inputting of tokens using the CIU is however successful. What is the problem? Richard Tonui.
Could you hire a qualified electrician to check if your meter can be switched to tamper mode? You can also share the photo of your powered CIU LCD Screen with our WhatsApp for help.
We are yet to find the shortcode for the model Smart Meter Technology 2023 to cancel the Audible Alarm. In the meantime, you can top up the credit or disconnect the CIU power cable and avoid depleting the token without knowing.
Try to replace your batteries with a new ones. Also whenever you're loading the token make sure you have plugged the CIU on the socket and switch it ON.
Please check your wiring, Neutral and earth MUST be independent in the consumer box and any other point of termination in the house. Never join Neutral and Earth at any point after the utility meter box. Check out this TH-cam video th-cam.com/video/MkVCpzReOAo/w-d-xo.htmlsi=LZCf1yAEeEGPCjWV
If the meter has been tampered with, you're required to visit your nearest KPLC office for a clear tamper code. Hire a qualified Electrician to assist you before inputting the code.
Kindly make sure that the account No you purchased the token/Credit with is correct, you must input token digits correctly, The CIU you're using to load the token Must be correctly Configured with its MCU and last the meter should be updated.
Asante Sana ❤❤❤ nilikua nianze kulia. It works
Welcome
What of the latest UNP112
My meters acc starts with 144 they were installed by kplc this year, they have connection problems when loading token.They always displays 'failed' what could be the problem? kindly assist.
This is how to troubleshoot: First, make sure the MCU is ON, In the Consumer Unit all MCB circuit breakers including the Double pole isolator must be ON. The CIU batteries Must be in good condition, inside your house plug in your CIU in the power Socket outlet and Switch it ON. You can load your token without hustle or stains. To understand better check out this TH-cam video th-cam.com/video/gsNAaCb9t_U/w-d-xo.html
My smart meter its having a problem with the ciu keypad when pressed a certain number it jump to another digit so am un able to load token any idea to restart the ciu.
Please are all the token to be input on the meter or we have a standard which all meter commissioning must follow?
Pardon your question please.
Hi, it taken like three months without loading token, now i've purchased to load in but unfortunately when i fix it on the socket and key in the codes then enter it just reads 000, what could be the problem?
You should contact a qualified electrician with an excellent reputation who can assist you with troubleshooting. Contact us at 0754879439
Weuh hii yangu inakunywa token kama wa munyota show me how I can see instantenous power consumption (load) cause tell me why tulilala saa sita ikiwa 1.89,
Right now its at 0.88 and I bought juzi 5 units in the morning na nikatoka
Can I use 1 ciu for 2 smart meters of same model 2021 as one of my ciu keypads not responding,any help and idea pls.
Yes you can use but one at a time. To pair input 1593570 plus meter No then press Okay/enter key.
Hey, guys [Electricians, Electrical students, and Utility Customers. This is a special video regarding the ACTIVATION of the SMART METER TECHNOLOGY Prepaid Energy Meter Model 2023, Kindly Watch this video, Like, Comment, and support us by SUBSCRIBING to this channel. Where you don`t understand Feel free to ask all questions below, in the comment section or reach us on WhatsApp wa.me/c/254754879439. You can watch a full video on how to INSTALL and activate Clou & Smart meter Technology by clicking this link. th-cam.com/video/ZN6dG2L86Vk/w-d-xo.html
Mine displays failed when i mate with meter s/n,what could be the problem
To troubleshoot check out this TH-cam video. Click the link below.
th-cam.com/video/gsNAaCb9t_U/w-d-xo.html
My meter starts with 92.....
It was successfully activated and commissoined but after 1 month of working well, the power supply suddenly stopped! Inputting of tokens using the CIU is however successful.
What is the problem?
Richard Tonui.
Could you hire a qualified electrician to check if your meter can be switched to tamper mode? You can also share the photo of your powered CIU LCD Screen with our WhatsApp for help.
If the screen on the CIU has a blinking icon like this __/ __ Try pressing 000 then enter, had the same issue today and the code sorted it out
Hello.
Hiw do I stop the alarm.... Its so annoying at 5units it beeps
We are yet to find the shortcode for the model Smart Meter Technology 2023 to cancel the Audible Alarm. In the meantime, you can top up the credit or disconnect the CIU power cable and avoid depleting the token without knowing.
Is commission number the same?
My doesnt load on batteries ...only when there is power what could be the issue
Try to replace your batteries with a new ones. Also whenever you're loading the token make sure you have plugged the CIU on the socket and switch it ON.
This meter consumes alot of power i dont know why
Please check your wiring, Neutral and earth MUST be independent in the consumer box and any other point of termination in the house. Never join Neutral and Earth at any point after the utility meter box. Check out this TH-cam video th-cam.com/video/MkVCpzReOAo/w-d-xo.htmlsi=LZCf1yAEeEGPCjWV
I agree. I use 1000ksh every 8 days
Very worrying
I have token and I want it to activated
To Activate model Smart meter technology energy meter watch this video and follow the procedures.
Cant be able to load mine...it just read 0.00 all the time and saying error 006
Kindly hire a qualified electrician to assist you, if the problem persists report the meter as faulty to your nearest Kplc office for Replacement.
What if the meter has tampered
If the meter has been tampered with, you're required to visit your nearest KPLC office for a clear tamper code. Hire a qualified Electrician to assist you before inputting the code.
My has a reject sign and reject words
Kindly make sure that the account No you purchased the token/Credit with is correct, you must input token digits correctly, The CIU you're using to load the token Must be correctly Configured with its MCU and last the meter
should be updated.
Why is mine not working
What`s wrong? Could you have tampered with the meter after installation or powered the meter without properly tightening the terminal cover?
Meter reject commissioning code
DAWA NI SOLAR SYSTEM KPLC WAKOME 😂🤣🤣😂