How to check the Hours on forklift Crown RC 5500

แชร์
ฝัง

ความคิดเห็น • 8

  • @mpc1mil
    @mpc1mil 2 หลายเดือนก่อน

    Amazon just trained me on one of these, a clamp type, for the last 2 days now, and I hope I get the hang of it quick cuz I really suck right now. I hope they don't fire me

  • @zeusrozo7490
    @zeusrozo7490 หลายเดือนก่อน

    Les agradezco el video sin embargo me hubiera gustado que fuera explicado bien para qué sirven las teclas direccionales hacia arriba y hacia la izquierda

  • @forklifttechnicianguru5126
    @forklifttechnicianguru5126 2 ปีที่แล้ว

    Good

  • @lancethomas4566
    @lancethomas4566 ปีที่แล้ว

    It looks brand new

  • @luisfernandomartinezrengif8581
    @luisfernandomartinezrengif8581 ปีที่แล้ว

    Tengo el código 204 en una rc5500 y no he podido solucionarlo, me ayudan por favor?

    • @forkliftiq
      @forkliftiq  ปีที่แล้ว

      Aquí está la causa del error 204

    • @forkliftiq
      @forkliftiq  ปีที่แล้ว

      Event Code 204
      The pump motor (M3) current is low during opera- tion.
      AC lift trucks only
      Step 1: Make sure that the power cables are con-
      nected correctly between M3 and Access 2.
      • If:The power cables are not connected correctly.
      - Then correct the power cables as necessary.
      • If:The power cables are connected correctly.
      - Then continue to Step 2.
      Step 2: Check for loose coil connections at the pump contactor (P), CA411-8 and CA411-9, and at ACCESS 2 CA409-2 and CA409-8.
      • If:The coil connections are not connected correctly. - Then correct the coil connections as necessary.
      • If:The coil connections are connected correctly. - Then replace Access 2.
      ELECTRICAL SYSTEM
      Event Codes
      - Then correct the power cables as necessary. • If:The power cables are connected correctly.
      - Then continue to Step 2.
      Step 2: Check for loose coil connections at the pump contactor (P), CA411-8 and CA411-9, and at Access 2 CA405-26 and CA405-27.
      • If:The coil connections are not connected correctly. - Then correct the coil connections as necessary.
      • If:The coil connections are connected correctly. - Then replace Access 2.
      Fig. 25 (15997-01)
      Event Code 204
      The pump motor (M3) current is low during opera- tion.
      DC lift trucks only
      Step 1: Make sure that the power cables are con-
      nected correctly between M3 and Access 2.
      • If:The power cables are not connected correctly.