Thanks for sharing this type of technical knowledge. Please guide how M40 grade can be achieved, with permissible value in Compressive strength parameters
Sir I am a manufacturer of concrete pipes. Please suggest a admixture product for pipes. Also suggest a product which can be used to join two different concrete parts together with a leak proof joint. I require a admixture which can reduce or eliminate the long curing process, quick demolding and very early strength. I use huge water tank for completely immersing the pipes for curing for 20 days. Also suggest a mix design.
Hello sir, nice video. Can you also make one video on what are the government and other permission needed for starting the business and what are the things needs to consider as an quality check? Please
Dear Jaitley sir, Thankyou so much for your support and guidance through your TH-cam videos. We are using Set and Shine chemical to make 40MPa paver blocks of 90mm thickness of size 8*4(inches). We are following 1:2:4 ratio as suggested in your video. Issue is test result is not more than 26MPa after 14days. Please kindly guide us to improve as we are in production presently and can cause financial loss in business.
My understanding to get 40 mpa was to run a mix of 4 gravel, 3 washed concrete sand, 2 cement and 1 water. The gravel needs to be 1.6 mm to 5 - 7 mm, with all of the fines removed. At this time, you are using a 1 cement to 6 other parts ratio; this is why you are getting lower strength. The ratio that I am using is 2 cement to 7 other parts ratio; which equals a 3.5 sand / gravel to 1 cement. Oh, I am also using sun dried sand in my mix, and weighing down to 10 grams per mix. By using dried sand, this reduces the amount of moisture in the mix, as excess moisture is a destroyer of concrete strength. This applies to the gravel, sand, cement and water. I have not gotten around to using admixtures as yet, but am looking at alternatives for waterproofing and elasticity. My mixes are being done as dry mix, strip the mould and reuse immediately. You can do wet mix, but this means that you need a heap of moulds to make your products. There are channels on TH-cam that show the means of dry mix; look for egg block machines as an idea. Compressed Stabilised Earth Brick (CSEB) also use a dry mix for production; they are pressed then watered for 14 to 35 days, depending on who is making them and where they are. My aim for the strength test is to achieve 40 mpa after 7 days, and another 15 or 20% at 28 days. Strength test also depends on how the test is performed! Don't do what one "expert" done - Jack with pressure gauge, 50 mm wide steel U beam, and brick hanging out each end! The test is meant to be done with the load fully spread across the whole item being tested, and to be done on flat surfaces on both sides!!! This will give a true indication of the strength of the item being tested. According to "Men At Work", I come from a land Down Under! Go the boxing kangaroo!!!
Sir please help with knowledge of below mentioned points. 1. If you use Pond ash then what will be the ratio 2. Will using pond ash reduce cost 3. As per My knowledge strength of 60 mm paver should be 35N/mm^3 and is marked as M35 and strength of 80 mm paver should be 40N/mm^3 and marked as M-40. How we can achieve this using pond ash 4. Can we use a mixture of both set&shine and Rapidash. If yes then in what quantity
Paver bolck industries ke godfather sashtang pranam Eastern check karne mein dikkat hai a rahi bar bar engineering college jaane per check nahin karte plant per check karna hai to kaise cube testing machine nahin abhi tak kisi ne manga nahin hai apni jankari ke liye daily Vespa quality control check karne ke ek quality control form banaya Jo hamara ek aadami daily check karta hai quality ko
Tiles banane ke liye 300*300*25/30 mm thickness suggest
Superb .. very valuable information possible only with vast experience and knowledge of the precast industry ..
Thank you vinay ji
Bahot badhiya sir 🙏 aise hi naye naye knowledge bhare video share karte rahiye sir 👍😊
Thank you
Thanks for sharing this type of technical knowledge.
Please guide how M40 grade can be achieved, with permissible value in Compressive strength parameters
Compressive strength 400/CM.SQ ka Strength ke liye mix Design bataiye (interlocking bricks ke liye)
sir M15 grade ke paver me water kitna dalne ha
Sir I am a manufacturer of concrete pipes. Please suggest a admixture product for pipes.
Also suggest a product which can be used to join two different concrete parts together with a leak proof joint.
I require a admixture which can reduce or eliminate the long curing process, quick demolding and very early strength.
I use huge water tank for completely immersing the pipes for curing for 20 days.
Also suggest a mix design.
Very good informative talk. Keep it up. Jay hind
सर,
आप तो प्रोफेसर ही होना चाहिए था 👏👏
😀😀😀
please provide your previous video
Sir hydraulic pressure machine k paver block m same formula lagy ga kya
Sir 100mm ka paver ka m50 keise aayega please batao
Best sir
Well explained with experience
Please explain about vibro pressed pavers.
Sir yahi ratio hum press machine me banaye to w/c ratio kya hoga
Jetly ji how to achieve 50mpa strength for paver block, kindly can you tell about mix designe, swastik tile.
hydrolic tiles me kaise banta hai sir m 40 ka tiles
Hello sir, nice video. Can you also make one video on what are the government and other permission needed for starting the business and what are the things needs to consider as an quality check? Please
mujhe epoxy risen k baare me jaan n na ha
or uska rate k baare me agar aap help kar sakte ha to please kijiyega
Sir me west Bengal se hu.me 1 liter setnshine chemical chak kerna chaha ta hu.west bengal me milega ea.
Sir Is mein Pani ka bhi Koi fark padta hai kya hamare yahan khara pani hai
haan khara pani ke liye electronic water conditioner use karen
Very much informative
What is the admixture name what u indicate...plzz mentioned the name
Sir.. 1" paver ke liye keya ratio honge.? For 40 mpa
Dear Jaitley sir, Thankyou so much for your support and guidance through your TH-cam videos. We are using Set and Shine chemical to make 40MPa paver blocks of 90mm thickness of size 8*4(inches). We are following 1:2:4 ratio as suggested in your video. Issue is test result is not more than 26MPa after 14days. Please kindly guide us to improve as we are in production presently and can cause financial loss in business.
Please WATSAPP 8435803967
My understanding to get 40 mpa was to run a mix of 4 gravel, 3 washed concrete sand, 2 cement and 1 water. The gravel needs to be 1.6 mm to 5 - 7 mm, with all of the fines removed. At this time, you are using a 1 cement to 6 other parts ratio; this is why you are getting lower strength. The ratio that I am using is 2 cement to 7 other parts ratio; which equals a 3.5 sand / gravel to 1 cement. Oh, I am also using sun dried sand in my mix, and weighing down to 10 grams per mix. By using dried sand, this reduces the amount of moisture in the mix, as excess moisture is a destroyer of concrete strength. This applies to the gravel, sand, cement and water. I have not gotten around to using admixtures as yet, but am looking at alternatives for waterproofing and elasticity.
My mixes are being done as dry mix, strip the mould and reuse immediately. You can do wet mix, but this means that you need a heap of moulds to make your products. There are channels on TH-cam that show the means of dry mix; look for egg block machines as an idea. Compressed Stabilised Earth Brick (CSEB) also use a dry mix for production; they are pressed then watered for 14 to 35 days, depending on who is making them and where they are.
My aim for the strength test is to achieve 40 mpa after 7 days, and another 15 or 20% at 28 days. Strength test also depends on how the test is performed! Don't do what one "expert" done - Jack with pressure gauge, 50 mm wide steel U beam, and brick hanging out each end! The test is meant to be done with the load fully spread across the whole item being tested, and to be done on flat surfaces on both sides!!! This will give a true indication of the strength of the item being tested.
According to "Men At Work", I come from a land Down Under! Go the boxing kangaroo!!!
Many many thanks always for sharing your knowledge 👍
Sir Thanks for useful knowledge sharing, pls give some ideas mix design for concrit , I will thankful to you
What's the price of your bonding agent
Good
How to buy set n shine product... in faridabad haryana and how much cost of one drum of set n shine
I am from Bangladesh and would like to contact you as I wished to make pavor and parking tiles.
Sir ji
Clay brick and usse related channels ke bate me video banso
Opcor ppc kon cement use karna hoga
thank you very much
Sir kuch colers kai bare mai bataiye ke kon saa le or kon saa accha hota hai...kyoki market mai bhut sy available hai..
Tata ,Dcw
Dcw
Apne vada kiya tha achche paver banane ka tarika
Very good
Useful information 👌
Mould ke liye kanha sampark karu.?
Sir 50 mpa vedio banaie
Mera Bhagwati hydraulic paver block machine hai usme strenght nahi aah raha mujhe 40 mpa grade chahiye strenght 925-1080 hona chahiye kindly ratio dijiye
70:20:10 ratio for flyash: stone dust: OPC cement
I would like to purchase set and shine. Do you have any dealers,/sellers in Bangladesh.
+918435803967 WATSAPP
Very knowledgeable
Wah sir ji kya baath hai..,👍 mujhe "set and shine " trail pack Lena hai..
My aap se kaise contact karu?
Please watsapp me on
8435803967
Putty ka formula share kar sakte hain
Sir wall Puty banane ka vedio
Kya price h set and shine
Sir iron oxides kha se le kuch links dijiye tata ya dcw ka
Kon se State se ho sir aap
@@ashishgarhwal176 rajasthan
Dear sir,
Please guide regarding requirement of curing for paver block
+91 6363416038
Sir aap see baat krni hai, phone pr contact nahe ho paa Raha hai..
M 35 ka bataye sir
Pavour ki kohni bahut tut jati hai kya kare bataye
Sir pls give me a idea to start making paver by manually. Coz I don't have lacs to invest
DEFINETLY , +91 6363416038
Kitne kitne mm ke Aate Hain favour block
Thanks Sir 🙏🙏🙏🙏
Best information
Video start at 7.00
Tiles banane ka tarika 300*300*25 mm or 30 mm
Good suggestion
How about a cover block mix ratio ?
Kishanganj district, Bihar
Sir
you are great. Always prayfull for u.😍
Thanks brother
Jammu mai available hai aap ka chemical
Rs 9900 tax and transport inlcuding 250L drum watsapp 9717280820 to order MOQ 4-5 drum
Thank you sir
Dear sir tell me about ciment to you's paver products
Opc
Ppc
Psc
Any cement can be used
Thank you for information
Supr sir
Set and sine ka price kya he
Rs 9900 tax and transport inlcuding 250L drum watsapp 9717280820 to order MOQ 4-5 drum
M 40 kya hota h
Sir please help with knowledge of below mentioned points.
1. If you use Pond ash then what will be the ratio
2. Will using pond ash reduce cost
3. As per My knowledge strength of 60 mm paver should be 35N/mm^3 and is marked as M35 and strength of 80 mm paver should be 40N/mm^3 and marked as M-40. How we can achieve this using pond ash
4. Can we use a mixture of both set&shine and Rapidash. If yes then in what quantity
Please watsapp me
@@hardandshinechemicalspvtlt2839 sure sir
Hard and Shine dealer near me
I am at Chandigarh
Aap k contact no bataye sir🙏
Send your no sir
Rs 9900 tax and transport including 250L drum for pavers watsapp 9717280820 to order MOQ 4-5 drum
Sir m aap se training lana chahta hu
Nice ....
I want to buy set and shine
Sir
Please watsapp me on 8435803967
Rs 9900 tax and transport inlcuding 250L drum watsapp 9717280820 to order MOQ 4-5 drum
Setnshine price
178
@@abhinay4932 178/ litre ?
Rs 9900 tax and transport inlcuding 250L drum watsapp 9717280820 to order MOQ 4-5 drum
Sir... aapki awaz or face actor nana patekar se milta hai.😁
50 mpa 80mm ka mix dizene
SIR GUIDE US SHORTLY TIME INTEVALS WE ALSO START PAVER I MAKING BUSINESS IN PUNJAB(FATEHGARH SAHIB) SHORTLY MASTER CHHATARPAL SINGH
for more details and technial support whatsapp / call - +91 6363416038
💯👌👌🙏🙏
50 kg cement. 1-2-4 ratio men kitini zig jug paver blocks Banti hain sir. please mention me sir.
One of the biggest mystery solved, why engineers failed from businessman in market.
🤣🤣🤣🤣🤣
जय भीम । जय भारत ।।
Ye chemical slab me Dal sakate hai kya ?
@@kishanbaichimanani7073 ji sir whatsapp me 7878014938
आप तो अपने प्रोडक्ट को बेच रहे हो।
product aacha hai inka humne use kiya 😊
Paver bolck industries ke godfather sashtang pranam Eastern check karne mein dikkat hai a rahi bar bar engineering college jaane per check nahin karte plant per check karna hai to kaise cube testing machine nahin abhi tak kisi ne manga nahin hai apni jankari ke liye daily Vespa quality control check karne ke ek quality control form banaya Jo hamara ek aadami daily check karta hai quality ko
Without ctm machine not possible
आयुष्मान भव
Very knowledgeable