  • Accumulator is a pressure vessel for storing hydraulic pressure in it utilizing compressible and decompressible nature of nitrogen gas. So, it can be said that the accumulator has a similar function to the rechargeable electrical battery. In electricity, electrical energy is stored to the battery.
    Function of Hydraulic Meter-In Flow Control Valve/How to work Flow Control Valve
    • Function of Hydraulic ...
    Function of Hydraulic Meter-out Flow Control Valve/How to work Flow Control Valve
    • Function of Hydraulic ...
    Function of Hydraulic Pressure Unloading/Offloading Valve
    • Function of Hydraulic ...
    Working principal of Compound Unloading Valve / Pilot Relief Valve
    • Working principal of C...
    DISCLAIMER
    Please read this disclaimer carefully before using this channel "UIS"(UTKRANTI INDUSTRIAL SOLUTION") operated by UIS
    The content displayed on the channel is the intellectual property of the "UIS". You may not reuse, republish, or reprint such content without our written consent.
    All information posted is merely for educational and informational purposes. It is not intended as a substitute for professional advice. Should you decide to act upon any information on this channel, you do so at your own risk.
    While the information on this website has been verified to the best of our abilities, we cannot guarantee that there are no mistakes or errors.
    We reserve the right to change this policy at any given time, of which you will be promptly updated. If you want to make sure that you are up to date with the latest changes, we advise you to frequently visit this page.
    Function of Hydraulic Meter-In Flow Control Valve/How to work Flow Control Valve
    • Function of Hydraulic ...
    Function of Hydraulic Pressure Unloading/Offloading Valve
    • Function of Hydraulic ...
    Working principal of Compound Unloading Valve / Pilot Relief Valve
    • Working principal of C...
    DISCLAIMER
    Please read this disclaimer carefully before using this channel "UIS"(UTKRANTI INDUSTRIAL SOLUTION") operated by UIS
    The content displayed on the channel is the intellectual property of the "UIS". You may not reuse, republish, or reprint such content without our written consent.
    All information posted is merely for educational and informational purposes. It is not intended as a substitute for professional advice. Should you decide to act upon any information on this channel, you do so at your own risk.
    While the information on this website has been verified to the best of our abilities, we cannot guarantee that there are no mistakes or errors.
    We reserve the right to change this policy at any given time, of which you will be promptly updated. If you want to make sure that you are up to date with the latest changes, we advise you to frequently visit this page.

ความคิดเห็น • 33

  • @ganeshmishra3437
    @ganeshmishra3437 2 วันที่ผ่านมา

    Very nice sir ji

  • @ankitsaini7407
    @ankitsaini7407 ปีที่แล้ว +1

    बहुत अच्छा समझाया sir ji

  • @amitkaushal9607
    @amitkaushal9607 2 หลายเดือนก่อน

    Very nice

  • @chotendorji5838
    @chotendorji5838 2 หลายเดือนก่อน

    In our system, there is leakages from the accumulator pipe line, so how can i change the O ring

  • @ravindrkumar5740
    @ravindrkumar5740 ปีที่แล้ว

    Very nice explained
    Thanks a lot🙏

  • @sureshmath3220
    @sureshmath3220 ปีที่แล้ว

    Much helpful thank you

  • @mechtech4881
    @mechtech4881 ปีที่แล้ว

    Very nice excellent

  • @hmdyoutubechannel8796
    @hmdyoutubechannel8796 ปีที่แล้ว

    good explenation and subscribe

  • @EC550EL
    @EC550EL ปีที่แล้ว

    TQ dear

  • @bhubanbag6840
    @bhubanbag6840 7 หลายเดือนก่อน

    Nitrogen pre charge ke upar ek video banaie gaa sir...

  • @james37090
    @james37090 2 ปีที่แล้ว +2

    Excellent bro

  • @Av-vi5vs
    @Av-vi5vs 2 ปีที่แล้ว

    Grt

  • @ehansaudinawab1138
    @ehansaudinawab1138 2 ปีที่แล้ว +1

    AND SIR IF HAVE 15GALLON ACCUMULATOR WHAT WILL MAX PRECHARGE OF N2 IS ANY MAX LIMIT????

    • @utkrantiindustrialsolution1416
      @utkrantiindustrialsolution1416  2 ปีที่แล้ว

      Dear sir,
      We are glad for your support and response,
      Actually N2 precharge pressure not only depends on accumulator volume, this is dependent much more factor to know the exact N2 precharge pressure we need some more information like design pressure of accumulator,
      Maximum & minimum operating pressure of hydraulic system which in installed bladder accumulator,
      Volume of bladder accumulator ( already you given 15 gallon),
      Hydraulic Pump flow,
      System temperature,
      Please give these above mentioned details we are full try to support to know exact filling N2 precharge pressure,
      But,
      Generally thumb rule of N2 precharge pressure 45% - 55% of maximum operating pressure,
      I hope you are this information helping for you,
      Please give some more information ( above mentioned) and we will helps to you know exact filling N2 precharge pressure.
      Thanks for visit our channel, and I hope we will getting your support in future and always support and encourage to our team.

  • @agusrahmat414
    @agusrahmat414 ปีที่แล้ว

    what is the standard for refilling nitrogen in a 6 liter 330 bar accumulator bladder ?

    • @utkrantiindustrialsolution1416
      @utkrantiindustrialsolution1416  ปีที่แล้ว

      Thankyou for Watching our channel
      Generally precharge N2 pressure 45-50% of maximum operating pressure,
      But know about exact precharge N2 pressure some other additional information to be needed
      1- oil pump low
      2- type of operation for hydraulic
      3- minimum and maximum operating pressure
      4- volume of accumulator (already you given- 6liters)
      5- maximum oil temperature.

    • @agusrahmat414
      @agusrahmat414 ปีที่แล้ว

      1. Pressure oil pump
      2. up and down the nozle and open the nozle lid.
      3. maximum oil pressure 200psi minimum 180psi
      4. The temperature of the oil is not known because it is always running with chiller water
      5. Additional information on machines for making foam for motorbikes and cars.
      Thank you very much

  • @rajnikanttandel8526
    @rajnikanttandel8526 4 หลายเดือนก่อน

    ecumletar lagane na purpose kya hai sir

  • @surenderkumar3852
    @surenderkumar3852 3 หลายเดือนก่อน

    Accumlator me kitne % Nitrogen gas hoti h ?

    • @utkrantiindustrialsolution1416
      @utkrantiindustrialsolution1416  3 หลายเดือนก่อน

      Thankyou for watching our channel..
      Generally Accumulator me 45 to 55% of Max operation pressure hota hai but kuch special case me OEM load and operational function ke hisab se special requirements set kerte hai

  • @ehansaudinawab1138
    @ehansaudinawab1138 2 ปีที่แล้ว +1

    SIR RUBBER TYPE NAHI NBR RUBBER HI HONNA CHAYEAH

    • @utkrantiindustrialsolution1416
      @utkrantiindustrialsolution1416  2 ปีที่แล้ว

      Dear sir,
      Thanks for supporting and visit our channel,
      You are absolutely right mostly bladder made from NBR elastomers,
      But some times use for bladder different types of elastomers like ECO, IIR, FKM.
      These all are types of elastomers for making bladder and these materials selection factor depends upon maximum temperature limit of hydraulic fluid,
      If you are know detail description of material selection according to temperature we will share with you material and its temperature chart,
      I hope we will help you,
      Please support us in future.

    • @rajeevchauhan1879
      @rajeevchauhan1879 10 หลายเดือนก่อน

      Very nice explanation sir
      For high temp we can use fkm and vmq. NBR eco good for 125°c

  • @asfakelectrician0786
    @asfakelectrician0786 7 หลายเดือนก่อน

    Apna no dijiye na sir

  • @abhimanyusingh6290
    @abhimanyusingh6290 7 หลายเดือนก่อน +1

    N2 is not inert gas

  • @faiyazahmad7815
    @faiyazahmad7815 4 หลายเดือนก่อน

    Send ou nambar

  • @surajlalsurajlal1819
    @surajlalsurajlal1819 ปีที่แล้ว

    Very nice

  • @MuhammadNaeem-jc9dt
    @MuhammadNaeem-jc9dt ปีที่แล้ว

    Sir apna nmbr bhej