Dear sir I have one doubt sir Refrigerant come to outside of condenser to store Recevoir But the same refrigerant come to outside of Evaporater (Recevoir not here .....why ). Because 100 percentage confirm liquid to vapour not done
Hi Jeyaprakash, when the refrigerant leaves the evaporator, as you said it doesn't get converted completely to vapour form. The compressor what we have is a vapour compressor, so it is good if the refrigerant is completely in vapour form. When a portion of the refrigerant is in the exit of evaporator, there are two ways to avoid entering in to the compressor. i) the expansion valve, which is in the form of coil is (stretched and is) made in contact with the vapour tube which exits from evaporator. by this act the liquid refrigerant towards compressor takes the heat from the liquid refrigerant which moves towards the evaporator. So the remaining refrigerant in liquid form gets converted to vapour in addition the refrigerant to evaporator is further cooled it is good as well. ii) There will be an accumulator in the suction line of the compressor to collect the liquid refrigerant. a filter - drier could also be fixed in the suction line of compressor. These are not included in the video to make it short. hope this clarifies the doubt. have great time, take care
Superb anna🎉
Sir ,good explanation about vapour compression system...Thank you
Best explanation sir🎉
Good
Ruskin sir..🔥🔥🔥
Satyam clg😍😍
Subcooling can be measured in condensor side and superheat can be measured in Evaporator side...superheat value is shows that system performance...
Bro awesome explanation please do lot more videos which is related to practical explanation
Very nice sir
Super explanation sir.......
Nice explanation
Dedication level 🤗🤗
Super sir
Refrigeration and air conditioning difference sollunga bro
Waiting for this one sir🥰
Thanks a lot Sir, hope it meets the expectation a bit. Will upgrade Sir.
Nice speaking
Bro backla irukra screen olunga terila
Dear sir I have one doubt sir
Refrigerant come to outside of condenser to store Recevoir
But the same refrigerant come to outside of Evaporater (Recevoir not here .....why ). Because 100 percentage confirm liquid to vapour not done
Hi Jeyaprakash,
when the refrigerant leaves the evaporator, as you said it doesn't get converted completely to vapour form. The compressor what we have is a vapour compressor, so it is good if the refrigerant is completely in vapour form.
When a portion of the refrigerant is in the exit of evaporator, there are two ways to avoid entering in to the compressor.
i) the expansion valve, which is in the form of coil is (stretched and is) made in contact with the vapour tube which exits from evaporator. by this act the liquid refrigerant towards compressor takes the heat from the liquid refrigerant which moves towards the evaporator. So the remaining refrigerant in liquid form gets converted to vapour in addition the refrigerant to evaporator is further cooled it is good as well.
ii) There will be an accumulator in the suction line of the compressor to collect the liquid refrigerant. a filter - drier could also be fixed in the suction line of compressor.
These are not included in the video to make it short.
hope this clarifies the doubt.
have great time, take care
@@engineeringfrombasics1825 yes Sir clarified...Tq
Bro unga number thaanga neenga Kanyakumari ah naanum Kanyakumari bro i need some help regarding hvac
Hi Kevin, Yes I am also from Kanyakumari district, you can reach me at ruskinbruce@gmail.com, shall speak to you, have good time