How to calculate the emergency light design

แชร์
ฝัง
  • เผยแพร่เมื่อ 9 พ.ย. 2024

ความคิดเห็น • 14

  • @godofallsuperpowers2136
    @godofallsuperpowers2136 2 ปีที่แล้ว +3

    Good day Sir! point of note. the luminaires you chose have a 100% Emergency lighting factor. when you look at the specs of the fitting you can see this has been specified. so instead of 10% you can use 100% which will allow you use fewer numbers of luminaire. Also it is advisable to change the Emin to 1 lux as this is the minimum I have come across in most standards and depending on the location and type of work some require 15 lux.
    I enjoy your videos. thanks for your work

    • @catalindesigner
      @catalindesigner  2 ปีที่แล้ว +1

      Good day to you as well. I appreciate your comment and happy to see that you were following all the information from the video.

  • @alriashi7
    @alriashi7 ปีที่แล้ว +1

    that was sooo beneficial for me ..thanks..

    • @catalindesigner
      @catalindesigner  ปีที่แล้ว +1

      Thanks of your feedback. Happy to help :)

  • @manjudileep5477
    @manjudileep5477 ปีที่แล้ว +1

    Hi Catalin, thanks for the video!Can we change the target lux levels on the emergency / escape route calculation

    • @catalindesigner
      @catalindesigner  ปีที่แล้ว

      Hi @manjudileep5477. First of all thanks for your question, to answer to your question I made the following video th-cam.com/video/dHY4tiIh74Q/w-d-xo.html. Please let me know if everything is clear now? Thanks :)

  • @BjornFarber
    @BjornFarber 4 หลายเดือนก่อน +1

    use the "calculate without furniture" button for hidden surfaces. It is to the left of the emergency groups

    • @catalindesigner
      @catalindesigner  4 หลายเดือนก่อน

      Hi Bjorn, thanks for your input!

  • @benhammadiafaf5538
    @benhammadiafaf5538 ปีที่แล้ว +1

    Hi catalin, thank you so much !

  • @marianmarquez7611
    @marianmarquez7611 2 ปีที่แล้ว +1

    Hi, did you change the reflectances of the room for emergency lighting calculation?

    • @catalindesigner
      @catalindesigner  2 ปีที่แล้ว

      Hi, I just watch the video once again to check if I made some changes related to reflectance but is seems that is not the case. Thanks for your question.

  • @zoltanvarga3583
    @zoltanvarga3583 11 หลายเดือนก่อน +2

    Maan, dont feel that I hating you, really not in bad , just simple my good advice - this emergency lighting simulation is wrong as it is possible - the escape route (the side corridor/stairs are part of the escape route too, minimum on the left side because of the upper door opening and the antipanic area where the seats are, where is?- I know that the simulation will without the seats, just the whole area, but it shall be approved too)...I really hope that this is not final version (measurement area/route placement) of the simulation - and really not in bad, peace

    • @catalindesigner
      @catalindesigner  11 หลายเดือนก่อน +1

      thanks Man for your comment. I apreciate you time in checking the video. As you can see in the video I took the antipanic, a flat area as an example how you can define it and not for implementation. If this project had to be implemented then you need to do the correct setup of height for each row of sets. In the case of escape routes, you just need to add the escape signs above the two doors, knowing that the antipanic lighting system will provide a higher light level than the one requested for escape routes.