HOW TO CHANGE THE COMPRESSOR OF A REFRIGERATOR

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ก.ย. 2024
  • Sharp two door ref, frosting type burn out compressor trouble repair.
    We install new 1/8 Matsushita Compressor. Its okay now, Watch the step by step process on changing the compressor and re charging refrigerant of this refrigerator.

ความคิดเห็น • 38

  • @johnpeterveril5823
    @johnpeterveril5823 3 ปีที่แล้ว

    Nice one idol may natutunan na nman ako😊

  • @edz4721
    @edz4721 4 ปีที่แล้ว

    Pa shout out naman dami kong natutunan sa RDC TV,ang galing nyo,keep it up

  • @renanreblinca3618
    @renanreblinca3618 4 ปีที่แล้ว

    Tnx master..next vedio po sana Kung paano mag troubleshoot ng water despenser

  • @liwagon13
    @liwagon13 3 ปีที่แล้ว

    sir pwede po ba magpalit ng compresor galing sa 1 door na ref at ilipat sa 2 door na ref, same naman po sila 1hp?pero magkaiba ang brand.. salamat

  • @irishvillanueva3499
    @irishvillanueva3499 4 ปีที่แล้ว

    gudday sir ask ko lng.po kung pwede po ba ipalit ung compressor ng ref sa ibang ref na kasing laki din nia.

  • @charlescabalteja4362
    @charlescabalteja4362 4 ปีที่แล้ว

    Sir ask ko lang po okey naman ung 2 relay saka thermostat ska compresor umaandar sya at uminit nai check ko napo cla , kaso lang ayaw po talagang lumamig ano po kaya ang dapat gawin pls. reply po

  • @romelcaingat4868
    @romelcaingat4868 4 ปีที่แล้ว

    Sir gud pm. Yung compressor ng ref namin ay on off lang i. Seconds. Dina lumalamig. Nagpalit na kami ng start relay at o erload pero ganun parin. Kung palitan po ba ng compressor kung sira na nga eh advisable kesa palitan na? Salamat po sa sagot and more power.

  • @raphaeljamesyator7203
    @raphaeljamesyator7203 4 ปีที่แล้ว

    Gud morning ka RDC, tanong ko lang Sana.....kapag ang 110v na ref na plug - in sa 220v ano po ang kailangan ayusin/palitan? Salamat

  • @mikelozada500
    @mikelozada500 4 ปีที่แล้ว

    Sir may tanong lang ako chineck ko yung relay at thermostat umiinit lang yung motor. Freon na kaya ang kailangan? Thank you sir.

  • @reymartin6905
    @reymartin6905 4 ปีที่แล้ว

    hi sir rdc tanong ko sana kung ano ang tamang watt ng heater para sa no frost yung nabiliko kc 45 watt nag titrip yung olp ko basag na kc yung dating heater valve dko mkita tung spec.TIA.po

  • @noy6245
    @noy6245 3 ปีที่แล้ว

    Sir ano po ba ginagamit kong rod sa copper to metal? Para sa condenser., Hindi po kasi dimidikit ang silver rod kahit may plax., Slamat sir

  • @marinelcapunoo2422
    @marinelcapunoo2422 4 ปีที่แล้ว

    Gud am po bos. Aq po ung nagtanung sa inyo nung nkaraan. Humihnto po ung compresor ng ref ko kya mtagal mg yelo. Hinawakan kopo ung compresor sobrang init. Sira na po b un. Aus pa nman po ung thermostat. At mga relay.

  • @israelcabiles8238
    @israelcabiles8238 4 ปีที่แล้ว

    Idol kapag grounded na ba ang compressor ng ref ay sira n to at kelangan ng palitan?yun kc ang sabi ng repair man.

  • @Offshore17
    @Offshore17 5 ปีที่แล้ว +1

    Boss regarding sa compressor meron kasi kming sira na ref. Yung compressor nya gagawin ko sanang portable vacuum/air compressor paano ang tamang wiring diagram nya? Anong gamit mga kailangan?
    Yung compressor nakikita na yung 3 pins nya.

    • @RDCTV
      @RDCTV  5 ปีที่แล้ว

      GANUN DIN PO ANG WIRING SA DATI

    • @Offshore17
      @Offshore17 5 ปีที่แล้ว

      @@RDCTV nabaklas na kasi sir dko na alam ibalik, ano ba dapat ko bilhin para mapagana ko sya?

  • @rickytadeodeguzman2972
    @rickytadeodeguzman2972 4 ปีที่แล้ว

    Sir, tanong lang po kung safe bang tanggalin ang compressor ng ref namin. Plano ko kasi lagarihin ung mga tube pipes para tanggalin ang compressor. Any tip po?

  • @mr.k4830
    @mr.k4830 4 ปีที่แล้ว

    Sir rdc tanong q lng po... What if ang compresor ay gumagana.. narutal po b na mainit ung compresor? Then sa loob ng ref ay lumalamig ung freezer pero wlang frost.. anu po kya ang problema? Salamat po at sana masagot nyo ang tanong q..

  • @rosaliolood6194
    @rosaliolood6194 5 ปีที่แล้ว

    Boss rdc tanong ko lng po magka iba ba ang compresor at motor? Salamat sa sagot boss.

  • @shelokasimsiman2288
    @shelokasimsiman2288 4 ปีที่แล้ว

    Tanong ko lang po f magkano magagastos kapag compressor na po ang sira?at magkano po yung sinasabing avr na pang ref?kasi mayat maya ang brownout dto samin,sana po masagot,t.i.a

  • @wendelarcos7849
    @wendelarcos7849 3 ปีที่แล้ว

    Idol mag kakapareho po ba ang serial number ng compresor motor salamat po idol more power po

  • @mercycomawas3946
    @mercycomawas3946 4 ปีที่แล้ว

    Sir ung ref ko na condura inverter ayw lumamig 2 years pa lng.sbi nung technician sira DW Ang board..papalita nlng dw pti compressor..maging ordinary ref na DW un after..4k Ang hingi nya..Tama Po bah?
    Pls .answer Po.. salamat

    • @boybulkivlogs5543
      @boybulkivlogs5543 4 ปีที่แล้ว

      Ganyan dn sa akin samsung naman 1 year p lng mahigit tinanong q mga 4k to 6k daw aabutin parang niloko tayo e

  • @kelbertgarcia8177
    @kelbertgarcia8177 4 ปีที่แล้ว

    pano malalaman yung sira ng inverter na freezer? ska pano yung pagcheck ng compressor nya 230v. po ska R600

  • @rosemariemangaring7020
    @rosemariemangaring7020 3 ปีที่แล้ว

    Sir sabi po ng tumingin ng rrp nmin compressor daw po ang sira ng.ref mga magkano po kaya un

  • @finjie3803
    @finjie3803 4 ปีที่แล้ว +1

    Paano po malalaman sir kung saang linya sa compressor ikabit ang condenser o evaporator po?

    • @RDCTV
      @RDCTV  4 ปีที่แล้ว

      discharge line po puntang condenser, suction line galing evaporator

  • @henjietorres3577
    @henjietorres3577 4 ปีที่แล้ว +1

    Sir rdc, flammable b ang R600a at sn b ito gngmit?

    • @RDCTV
      @RDCTV  4 ปีที่แล้ว

      opo thanks for watching po!

    • @odnamraatsituab9643
      @odnamraatsituab9643 4 ปีที่แล้ว

      sir tanomg ko.lang po bakit umiinit ang sides ng ref at yung compressor model SJ-S170T-SS slamat po

  • @ajnuquejr8188
    @ajnuquejr8188 4 ปีที่แล้ว

    San makkbili sir nang compressor po?

  • @boybulkivlogs5543
    @boybulkivlogs5543 4 ปีที่แล้ว

    Inverter b yan boss

  • @michaelongtawco6289
    @michaelongtawco6289 4 ปีที่แล้ว

    Di na pala kelangan mag flushing?

  • @paomabini8506
    @paomabini8506 5 ปีที่แล้ว

    Sir ask klang
    What is the diff. bet. Frosting & Non frosting ref.??
    Thanks ..

    • @mamagayoRontv9854
      @mamagayoRontv9854 5 ปีที่แล้ว

      pao mabini.. yung sa evaporator ng ref.. yung isa frosting nag yeyelow sa liob ng ref mo.. kc wla yung masyadong heater.. yung non frosting namn masyadong madami ang heater.. malaks dn kumain kurynte ng non frosting kc sa heater nya

    • @pedapsaparece1311
      @pedapsaparece1311 4 ปีที่แล้ว

      Boss my video kaba plate type na evaporator Ng refrigerator convert to coil type evaporator..

  • @israelcabiles8238
    @israelcabiles8238 4 ปีที่แล้ว

    Hindi n kc lumalamig yung ref nmin.

  • @stephaniemangaban3866
    @stephaniemangaban3866 3 ปีที่แล้ว

    Akala ko remove