Gas Furnace Spark Ignition Control Troubleshooting!

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ธ.ค. 2024

ความคิดเห็น • 267

  • @acservicetechchannel
    @acservicetechchannel  7 ปีที่แล้ว +4

    Tool List- www.amazon.com/shop/acservicetech
    Support- www.patreon.com/acservicetech
    For those that are looking for the tools used in the videos: (Linked Below)
    Here is a link to the UEI DL389 Multimeter used in the videos- amzn.to/2av8s3q
    Here is the link to the Fieldpiece SDMN6 Dual Pressure Testing Manometer with Pump-amzn.to/2jyK5Ka
    Here is a link for the Supco Magnet Jumpers amzn.to/2gS4h6z
    Here is the link for the Irwin Wire Stripper/Cutter/Crimper amzn.to/2dGTj2V
    Other tool links can be found in the video description section.
    ACSERVICETECH is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.

    • @fredfred7361
      @fredfred7361 3 ปีที่แล้ว

      Wwzx

    • @jimv3352
      @jimv3352 ปีที่แล้ว

      Mine will ignite but as soon as the pilot light is lit, I hear a click in the control board and everything shuts off.
      Then it clicks again and the whole process starts over. But as soon as I have a pilot flame, everything shuts off again.

  • @jessec7821
    @jessec7821 ปีที่แล้ว +12

    I am by no means an HVAC guy but am mechanical and this is how every video should be.. straight to the point, all setup, and no shaking camera. 12/10, I wish every video followed this format

    • @gdmedic4346
      @gdmedic4346 ปีที่แล้ว +1

      i am not a math professor by trade, but 12/10 is not good math.

  • @Bilmor1982
    @Bilmor1982 ปีที่แล้ว +4

    Sir you are extremely gifted at teaching! You make everything so clear and practical I’m sure you are a walking encyclopedia but you watered everything down so good but yet very substantial! God bless you sir!!!

  • @jotermoter
    @jotermoter ปีที่แล้ว +1

    Thanks. 6 years later and you are still helping people! Used this for my Raypak pool heater troubleshooting.

  • @bawlout9367
    @bawlout9367 2 ปีที่แล้ว +1

    ran into one of these in the field , before seeing this video your trouble shooting and refresher videos helped me isolate this part as the issue. thanks again for the extra insight

  • @petebacher
    @petebacher 5 ปีที่แล้ว

    THANK YOU! My Raypak pool heater has this setup and none of the Raypak manuals provide any details on how it works. Your video was EXACTLY what I needed to understand this setup so I can effectively troubleshoot it. Thanks for taking the time to make and post this great tutorial!
    -Pete

  • @lupine617
    @lupine617 2 ปีที่แล้ว +2

    Truly splendid explanation and awesome demonstration on trouble shooting this system, and all the units involved...

  • @Rezcat-y6r
    @Rezcat-y6r 7 ปีที่แล้ว

    Thank you,again. It's Blaze. I cleaned up my ground to my unit chassis and replaced the flame sensing rod. When I energized the unit I had the same problem. One thing that I didn't notice was that the burner that had the sensing rod going to it was not lit. I removed the burner and pulled out the orfice and there was spider webbing inside the back of it and plugging up the opening. I cleaned it out with my tip cleaner for my oxyacetylene rig and returned it back to service. The unit is heating properly at this time. Thank you for your videos
    Blaze

  • @solweiss554
    @solweiss554 6 ปีที่แล้ว +2

    Very simple and thorough to the point. Practical without a lot of chatter.

  • @jmead6121
    @jmead6121 2 ปีที่แล้ว

    Thanks Great explanation on Spark Ignition 25 yr in & ive always struggled bc i rarely run into thees type ignitions 7 i seem to forget & have to start over almost ... but Now its so crystal clear & with my notes taken on phone i soon Not forget again lol Thanks Again for this & all uR Videos for ive been watching You for many years Now Tks xxx jerry

  • @johnrutkowski5929
    @johnrutkowski5929 3 ปีที่แล้ว

    I'm going to grab my multi-meter and start testing for spark. Thx for explaining how the system works.

  • @mdwilliams3824
    @mdwilliams3824 8 ปีที่แล้ว +2

    I agree another good video. Had this happen just last month, after verifying continuity through the safety loop I determined that the spark ignition bracket had heavy corrosion between it and the main chassis. Just a little sanding of both matting areas was all it took to get it going. Looking forward to your next video.

  • @INLANDEMPIREKING
    @INLANDEMPIREKING 8 ปีที่แล้ว +22

    incredible explanation. You sir are a great teacher

    • @acservicetechchannel
      @acservicetechchannel  8 ปีที่แล้ว +3

      Thank you very much caliguy909!

    • @emiliosanjim5874
      @emiliosanjim5874 6 ปีที่แล้ว +1

      Yo estoy bien triste , tengo un horno de panadería y creo y supongo está dañado l módulo de ignición es un
      RAM4 de robertshaw y no logro encontrarlo PR muy interesante tu video

  • @jasonley1529
    @jasonley1529 4 ปีที่แล้ว +2

    Great video! Curious how long the pilot should stay lit while it’s proving the flame. pilot lights, but goes out within a second... sometimes the main burner will light, but sometimes it doesn’t and then the pilot just cycles every few seconds... your video is the best explanation of the controller I’ve seen, but haven’t seen anywhere how long PV is supposed to stay open to prove the flame

  • @retiredguyworking8057
    @retiredguyworking8057 2 ปีที่แล้ว

    Excellent description of the operation. Having a second try turn on at times. Checking ground first. Thank you for giving me a place to start. Hopefully not the module!

  • @hvacguy11
    @hvacguy11 4 ปีที่แล้ว

    Thee absolute best HVAC instructional videos on the internet. Hands down!!

  • @mikeeames8463
    @mikeeames8463 7 ปีที่แล้ว +4

    The best tutorial I have seen on this subject. Thank you!

  • @robgullett9379
    @robgullett9379 6 ปีที่แล้ว +3

    Very good to-the-point, clear and concise explanation... great job!

  • @bassir2002
    @bassir2002 5 ปีที่แล้ว +3

    Just don't know how to thank you enough for this very informative video.

    • @acservicetechchannel
      @acservicetechchannel  5 ปีที่แล้ว

      Thanks Bassir2002 for any support- patreon.com/acservicetech

  • @liberaltearsaredrowningme7049
    @liberaltearsaredrowningme7049 8 ปีที่แล้ว +3

    Thorough, concise explanation. Very much appreciated.

  • @fastxsam
    @fastxsam 2 ปีที่แล้ว

    Thank you for this video very informative. I used this information to diagnose a faulty igniting module for a customer.

  • @phillipwoods5874
    @phillipwoods5874 8 ปีที่แล้ว +1

    Great job, iv'e learned more about the subject of furnace flame rectification from your three videos than i did in class. The grounding was never explained.I guess that's what you get from mostly book learning vs visual or hands on.

    • @acservicetechchannel
      @acservicetechchannel  8 ปีที่แล้ว

      Thanks Phillip Woods, yeah you need to teach in front of live equipment while explaining the subject with maybe a study guide to help. Thanks and nice image!

  • @guitarhvac
    @guitarhvac 4 ปีที่แล้ว +2

    Excellent explanation. Great refresher going from cooling back to heating season!

  • @ThomasWalker-m2y
    @ThomasWalker-m2y ปีที่แล้ว

    Very good explanation with actually seeing how it works.

  • @rocker8692
    @rocker8692 6 ปีที่แล้ว +1

    You are my new teacher now lol.I didn't pay attention in AC school.Excellent vid.

  • @dustinthewind5538
    @dustinthewind5538 8 ปีที่แล้ว

    Thank you for this video. Just had a no heat call on a lennox whisper heat with very similar set up this morning. Makes much more sense to me now after watching this.

  • @michaelcostello6991
    @michaelcostello6991 3 ปีที่แล้ว +1

    This was amazing video. Thank you. One of the best videos out there. You really nailed it.

  • @albotiger7268
    @albotiger7268 4 ปีที่แล้ว +1

    You are a great teacher! God bless you!

  • @jasona9231
    @jasona9231 6 ปีที่แล้ว +1

    What a great video and thank you for the clear, easy to understand explanation and demonstration. Excellent!

    • @acservicetechchannel
      @acservicetechchannel  6 ปีที่แล้ว

      Thanks Jason!

    • @jasona9231
      @jasona9231 6 ปีที่แล้ว +1

      Another thing I find impressive is that you courteously take the time to thank people for their comments...perhaps each and every one, that is great!
      I am working on my Dunkirk natural gas boiler from 1987 and I noticed the last season or two that it would frequently keep sparking the igniter even after the pilot and the main burners were lit. This year I decided to look into now that winter is on the way. This system uses "one wire" for detecting the pilot, not a separate flame sensor like on most modern models. The igniter rod (mostly wrapped in enamel like a spark plug just to be clear) appears that it may be a little dirty and so I would like clean it with some emery cloth but it is very difficult to reach while still attached to the center burner (3 burners total).
      My question is this... If I unscrew the two screws holding the iginiter assembly to the burner and bend the aluminum pilot gas tube a little toward me so I can clean the rod am I creating a safety hazard in the form of a leaky pilot gas supply tube? Will cleaning that rod even help me out, or is it likely a failing Honeywell control box?
      Thank you in advance! Keep up the great work.
      @@acservicetechchannel

    • @acservicetechchannel
      @acservicetechchannel  6 ปีที่แล้ว +1

      Cleaning the rod should help but it may be a weak signal on the ground coming back. If it has a separate rod for the ground then yeah cleaning that too will help. We uses steel wool and not emery cloth though due to silicone residue. We usually disconnect the pilot tube and spark assembly at the gas valve and just pull the whole assembly out. Try to not move the pilot tube around too much due to a possible kink. You could also just leak test the tube with non corrosive bubble leak detector like I have at amazon.com/shop/acservicetech thanks for the note and yeah it is a lot answering everyones questions but I try, thanks

    • @jasona9231
      @jasona9231 6 ปีที่แล้ว

      @@acservicetechchannel Thanks for the quick reply, very good advice, and professionalism. I had not thought of that point regarding emery cloth, glad you said something. I might just have to order that leak detector you recommended. Thanks again, take care!

  • @1adams1
    @1adams1 4 ปีที่แล้ว

    Great video and troubleshooting. Saved me a pile of money.

  • @chuckjones5987
    @chuckjones5987 6 ปีที่แล้ว

    Excellent breakdown of how this system works. Well done Sir!

  • @lancerudy6584
    @lancerudy6584 3 ปีที่แล้ว

    Thanks for great video. Helps 100,000 BTU.

  • @al52269
    @al52269 6 ปีที่แล้ว

    Great video.
    Great teacher.
    The issue I'm having is no spark or flame. I replace everything but the ignition wire.
    I replace gas valve,
    Ignition Control module, pilot burner,
    Still not getting a flame or Ignition clicking.
    I believe is my ground. Will try it.
    Thanks for sharing your knowledge

    • @acservicetechchannel
      @acservicetechchannel  6 ปีที่แล้ว +1

      Thanks, let me know how you make out. Do you have a strong 120v coming in while under a load and then a strong 24-28.5v?

    • @al52269
      @al52269 6 ปีที่แล้ว

      I did everything you did on your video. Still won't start. I noticed bad ignition wire. I'm going to order one as soon as I get a chance. Been working 7 days a week since February no days off unless a holiday and then I sleep during day due to I work 3rd shift. I think the Honeywell module may be bad even though it's new. After ignition wire is replace I will recheck everything again. I will let you know what my findings are. Thanks again for your help

    • @acservicetechchannel
      @acservicetechchannel  6 ปีที่แล้ว

      Oh nice, ok thanks

  • @DrManhattan7
    @DrManhattan7 5 ปีที่แล้ว

    First of all, EXCELLENT explanation, just wat I was looking for. Now, I still can't determine what's wrong with mine, slightly different model, but same basic functionality I have the S8610F. When the unit receives the call for heat, I get a spark, the pilot ignites, the spark stops once the pilot ignites, but no voltage passes to the MV, then pilot turns off. Then sparks starts again, turns the pilot on again and the cycle repeats. The fact that the spark stops, makes me think it's getting signal that there is flame, (why keep sparking if the pilot is already on, right?) but it's failing to pass voltage to the MV. For the grounding, I tested two things, continuity from the spark rod at te pilot to the spark terminal at the module (to test the spark wire) and it was ok. Then I tested continuity from the pilot assembly to the ground terminal at the control module, and it was good too. Any thoughts?

    • @acservicetechchannel
      @acservicetechchannel  5 ปีที่แล้ว

      Sounds like it is a bad spark control module if you are getting a flame rectification signal verifying the flame, thanks

    • @DrManhattan7
      @DrManhattan7 5 ปีที่แล้ว

      AC Service Tech LLC. Thank you for the fast reply. I ordered the module, let’s see how it goes.

  • @vernroach3413
    @vernroach3413 5 ปีที่แล้ว

    Always worth watching your videos...Thanks again.

  • @dukerob1973
    @dukerob1973 2 ปีที่แล้ว

    I hope you teach at your local jr college or tech school. You were made to teach man.👍🏻👍🏻

  • @Rezcat-y6r
    @Rezcat-y6r 8 ปีที่แล้ว

    Thank you for your videos. I just looked at the video regarding flame rectification and I think that I should look at my flame sensing rod along with my burner and the ground.
    Thank you again
    Blaze

  • @guillermomartin2185
    @guillermomartin2185 6 ปีที่แล้ว

    Great video. I have the same ignition setup as here, spark lasts up to 5 minutes before pilot is lit. If I move the pilot assembly away from the mounting point and pilot will light and 24 v is sent to main valve. It has a good ground.

    • @acservicetechchannel
      @acservicetechchannel  6 ปีที่แล้ว

      Is the pilot tube loose, is the flame good height after ignition? If the pilot head bent out of shape and gas not staying in the right area? thanks

    • @guillermomartin2185
      @guillermomartin2185 6 ปีที่แล้ว

      AC Service Tech LLC pilot tube is indeed bent. I tried to bend it back to center with a pair of channel locks but i don’t want to break the head. Do I have to tap it out of the housing it’s in to re center it?

    • @acservicetechchannel
      @acservicetechchannel  6 ปีที่แล้ว

      @@guillermomartin2185 It has a compression ring so once you undo the brass nut, the tube with compression ring would come out of the head. You would reround it with an adjustable wrench which has a flat surface turning back and forth on the outside diameter, thanks

    • @guillermomartin2185
      @guillermomartin2185 6 ปีที่แล้ว

      AC Service Tech LLC done. I reinstalled it and it does the same thing. It Seems like the inducer motor draft prevents the pilot from kicking on.

    • @101Parkside
      @101Parkside 2 ปีที่แล้ว

      @@guillermomartin2185 Hi, this is old news to you now since your question was 3 years ago. I'm having an issue with my furnace as well and while going through this thread I noticed you were talking about bending the head of your pilot burner to center it. In researching my issue, it seems to me that they make these pilot assemblies with a left of center or a right of center (and perhaps centered) pilot burner. I think that is, so the pilot flame burns toward the spark and sensor rod as well as angled toward the burner in order to ignite the flame. Whether left or right would depend on which side of a burner the pilot assembly was attached to. I'm not a tech but I think that seems to be the way they are. How did you make out?

  • @TheRealDegen100
    @TheRealDegen100 11 หลายเดือนก่อน

    This is exactly what I needed

  • @sirsmart1
    @sirsmart1 4 ปีที่แล้ว +1

    very good explanation ,,, step by step

  • @jamesrockford5145
    @jamesrockford5145 7 ปีที่แล้ว

    Great instructor! my instructor has students intimidated to ask questions.

    • @acservicetechchannel
      @acservicetechchannel  7 ปีที่แล้ว

      Ha ha that's weird. When people ask questions, it only makes the instructor better. We realize we have a limited knowledge and we need to think deeper or get ourselves into different experiences to eventually be confidant in answering that segment of questioning, thanks

    • @jamesrockford5145
      @jamesrockford5145 7 ปีที่แล้ว

      Can't wait to leave that class!!! Keep up the excellent productions.

    • @acservicetechchannel
      @acservicetechchannel  7 ปีที่แล้ว

      Thanks James!

  • @jorgeortega1413
    @jorgeortega1413 6 ปีที่แล้ว +1

    excellent explanation ,so clear ,so easy to understand great job ,great pro

  • @tommulcrone182
    @tommulcrone182 ปีที่แล้ว

    Once again thank you very much. You're the best

  • @xenghuong
    @xenghuong 4 ปีที่แล้ว +1

    Really informative! Thanks for the video.

  • @backho12
    @backho12 6 ปีที่แล้ว

    This guy is a genius! Thanks for the explanation!!!!

  • @jredbokie1247
    @jredbokie1247 10 หลายเดือนก่อน

    Thank you so much this helped me tremendously.

  • @whitesheatingairappliancer7101
    @whitesheatingairappliancer7101 4 ปีที่แล้ว +1

    Great video. I have tried in the pass to run a continuity test on the high voltage wire unplugged from everything else. I could never get a reading?

  • @jaysingh-ho7eb
    @jaysingh-ho7eb 3 ปีที่แล้ว

    Excellent explanation. Thank you

  • @michaeldower4335
    @michaeldower4335 6 ปีที่แล้ว

    Great explanation and demonstration.

  • @szcz546
    @szcz546 3 ปีที่แล้ว +1

    Thank you for this video

  • @spartan5106
    @spartan5106 10 หลายเดือนก่อน

    That was a very technical video

  • @GeminiSeven43
    @GeminiSeven43 2 ปีที่แล้ว

    Could you show the milliamp testing like you did for the dual rod flame and show what the milliamp reading should be for this Honeywell unit?

  • @leejagin7979
    @leejagin7979 4 ปีที่แล้ว +1

    Very helpful

  • @Realrhod
    @Realrhod 11 หลายเดือนก่อน

    Really good useful video. Thanks

  • @TheStudpop
    @TheStudpop 2 ปีที่แล้ว

    Just wanted to correct you on something you say here and in other videos. While it is true that the module detects the presence of a flame by passing a current through the flame-it is not detected by measuring current through the ground wire. Since all grounds are tied together, both with wires and by the metal chassis, there’s no way to measure ground current since there are multiple paths. It can only be measured on the “hot” side, meaning the current that’s flowing through the sensor wire. There’s probably an internal resistor in series with the sensor wire and the voltage drop across the resistor is directly proportional to the current.

  • @ChrisV-
    @ChrisV- 7 ปีที่แล้ว

    Good video, definitely will help when troubleshooting.

  • @Protek1
    @Protek1 7 ปีที่แล้ว

    Excellent presentation.

  • @chandarasena
    @chandarasena 7 ปีที่แล้ว

    Thank you very much, the explanation is very good.

  • @thesteveprichard
    @thesteveprichard 4 ปีที่แล้ว

    you the best I've ever heard!

  • @paulp757
    @paulp757 4 ปีที่แล้ว

    Outstanding. Very informative and well done!

  • @jasonjokiel7188
    @jasonjokiel7188 ปีที่แล้ว

    Awesome video

  • @Juegosdecartas101
    @Juegosdecartas101 8 ปีที่แล้ว +1

    Very good explanation I'm learning 👍

  • @franciscoflores2718
    @franciscoflores2718 3 ปีที่แล้ว

    Can you make a video on how to install the pilot silver tube.. or on what tool you use to straighten the pilot silver tube? I always have trouble getting the pilot silver tube straight enough

  • @TheRealDegen100
    @TheRealDegen100 11 หลายเดือนก่อน

    Great video. Only thing I think would have helped is if you added the gas valve into the sequence

  • @justinbayne4915
    @justinbayne4915 5 ปีที่แล้ว +1

    I am having a problem with the newer model of this board the s8610u . I am getting spark and pilot but no 24v to mv .we have checked all of the grounds. In this particular unit, the only way to prove the flame is on the ignition board, with this ignition board it has a jumper that you disconnect and hook a flame sensor to. We have tried cleaning the flame sensor and still nothing. Also we will replace the board and it will work for a week or two and then for some reason will not sense flame again. Need your help guru !!

  • @alacran1986
    @alacran1986 2 ปีที่แล้ว

    Can you explain lockout? I get 24V to the board but nothing to the gas valve PV and MV. After a reset everything works fine.

  • @saeedhameed9148
    @saeedhameed9148 7 ปีที่แล้ว

    Another great video very informative 👍👍👍👍👍👍👍🏻👍👍👍👍👍

    • @acservicetechchannel
      @acservicetechchannel  7 ปีที่แล้ว

      Thanks Saeed, here is the gas furnace ignition playlist- th-cam.com/video/qjrrXmLlLRc/w-d-xo.html

  • @zhenjiang4776
    @zhenjiang4776 6 ปีที่แล้ว

    Great video, I have the same issue, the pilot is on, but no main output, I check the ground is ok, the main output is always 0v.

    • @acservicetechchannel
      @acservicetechchannel  6 ปีที่แล้ว

      Disconnect the power and disconnect the ground then take a resistance reading from the pilot head to the end of the ground to see if the resistance reading is high, thanks

  • @101Parkside
    @101Parkside 2 ปีที่แล้ว

    Great video and explanation of steps and stages. I hope you can help me. I have this same setup, but the only difference is that I have a Honeywell S8600M Module that has all the terminals on one side as opposed to yours which has them on both. All the steps have been satisfied just as you have explained. I have spark, I have pilot light, I have 26.4 volts from the transformer to the module, I have 26.4 volts from PV to MV/PV and I have 26.4 volts from MV to MV/PV going to the gas valve. As soon as I turn the furnace on, I get spark and the pilot lights, I hear the gas valve click open but here's the PROBLEM ... the burners will not ignite. What are the next steps to try and diagnose? What is preventing gas from going to the burners to get ignited by the pilot light that is on and seems to have good coverage across the sensor rod? I live in Vancouver, so the furnace sits for 8 months unused and of course when a guy needs heat, that's when we end up with a problem. Hope you can help! (Edit: I should have mentioned that I also cleaned the spark/sensor rod with steel wool even though it looked good beforehand). Thank you!

    • @BuffaloFranimal
      @BuffaloFranimal 2 ปีที่แล้ว

      If you have 26 volts from my to mv/pv at the gas valve terminals it should open. After sitting for 8 months sometimes the valve sticks. If you give it a lil rap with a back [f a screwdriver it may open and work normally. If not check the resistance of the gas valve coil. It should be between 8-12 ohms otherwise it is likely open or shorted.

    • @101Parkside
      @101Parkside 2 ปีที่แล้ว

      @@BuffaloFranimal Thank you for your reply. I did try lightly tapping the gas valve but other vids also discourage that. As I mentioned, you can hear the valve click in sequence as though it's opening but as you say perhaps something isn't opening as it should. I will check out the ohms as well. I appreciate you taking the time to help. Cheers!

  • @JEFFREYHVAC12
    @JEFFREYHVAC12 7 ปีที่แล้ว

    very good info thanks for taking time for us youtubers

  • @aifrisyad7491
    @aifrisyad7491 ปีที่แล้ว

    how about the flame censor, do you have a video about the whole system (gas valve, module control, blower fan, flame censor and burner with ground wiring), thanks anyway

  • @EnjoyCalculus
    @EnjoyCalculus 3 ปีที่แล้ว

    During the flame rectification process in this setup, what part is the flame rod that is sending AC voltage to be rectified? How do you test its getting voltage

  • @nybiggs
    @nybiggs ปีที่แล้ว

    My 4 year old Weil Mclain boiler started exhibiting intermittent problems which first started in Christmas but seems to be happening more often. After the call for heat, I hear the pilot light, but the gas doesn't open and the burner never ignites. After a little while, the pilot will shut itself off, and the boiler is then locked out for good until I completely cycle power to the boiler.
    The issue is that this doesn't happen very often. Boiler runs fine for a week or two and then I get a call that there's no heat in the building. Calling a professional over, they see the boiler running and say they can't do anything.

  • @lijoima
    @lijoima 4 ปีที่แล้ว

    Great video as always. Having an issue with my single rod honeywell system. New pilot assy installed. Pilot not igniting by occuring spark however will ignite with a lighter. When pilot lit spark continues and no opening of MV. I'm unsure what could be causing both!

  • @MrMultitool
    @MrMultitool 8 ปีที่แล้ว +1

    Great Demonstration!

  • @gpsperez5193
    @gpsperez5193 2 ปีที่แล้ว

    Thank you for the video im having the same problem my module is a ruud rheem 780-715 u no spark no pilot it has only 24 volts is that enough volts?thanks

  • @EurekaRecycler
    @EurekaRecycler 3 ปีที่แล้ว

    Hi, can you do a video on where all the wires on this module go and what each wire does? Are most of these modules interchangeable? Thank you

  • @mikepotter3802
    @mikepotter3802 2 ปีที่แล้ว

    If there is a spark, but no flame what is likely the problem? I am editing this to include that I also would like to know when checking for 24V on the MV/PV to PV does it have to be during the spark attempt? Will there be a voltage after it gives up for about 5 minutes?

  • @melvin292
    @melvin292 7 ปีที่แล้ว

    excellent, excellent video!

  • @gyver471
    @gyver471 3 ปีที่แล้ว

    Damn what a great explanation

  • @litesp
    @litesp ปีที่แล้ว

    I have a mid-90s Carrier 58GSC upflow furnace. Last year, I had to cycle the power several times to turn the furnace. These last 2 months power cycling doesn't do anything. I changed out the control board without any success. I get 28V going to the Ignition control, but nothing happens. I don't get any spark or pilot gas flow. Should I clean the electrode first or just replace the Ignition control?

  • @SteveBowers-h5p
    @SteveBowers-h5p 11 วันที่ผ่านมา

    My radiant tube heater has a problem. When I set the thermostat to call for heat, the blower comes on, the igniter fires and it fires up. The thing is: the igniter keeps firing and then the gas valve seems to rapidly open and close after a minute or so. It does continue to run but, this can't be good. It's a 125k unit. I have a 150' run to the shop of 1" and about 8' of 3/4 to the heater.

  • @RC-Heli835
    @RC-Heli835 9 หลายเดือนก่อน

    i have that same model in my furnace. Does this thing shut the pilot back off in a certain amount of time if the main gas valve does not come on?
    A family AC tech was telling me that if it did not shut the pilot off when the main valve fails to light the burner that the pilot sensor is the problem. I tried a new one and it still does not work.
    I checked ground and all that with a continuity test and all checked out fine.
    Mine was not shutting off the pilot by the way after any amount of time.

  • @CrazyCHikcin
    @CrazyCHikcin 4 ปีที่แล้ว

    I think u just taught me how to fix my furnace

  • @yroncekenold878
    @yroncekenold878 3 ปีที่แล้ว

    You're so good

  • @jeeperguy4290
    @jeeperguy4290 ปีที่แล้ว

    Awesome video. I had a job today where the spark wasn’t occurring all the time, I was turning off and on the power to the unit until it sparked, pilot gas was lit & rectified. Burner came on followed by the blower. I’m not a hvac tech but a gas utility worker who does safety checks. Didn’t think to check the ground but sounds like that might have been the issue? What do you think? I would toggle the switch back and forth until the spark occurred and it was fine after that. I could hear the hum of the xfrmr so I don’t think it was service disconnect switch.

  • @1weirddoe571
    @1weirddoe571 4 ปีที่แล้ว

    The sparker is also a sensor? Have a video on this "flame rectifier"? Also, why have a pilot since power-vent water heaters don't or do they?

  • @playmusic972
    @playmusic972 ปีที่แล้ว

    well explained

  • @realuniversechannel1
    @realuniversechannel1 7 ปีที่แล้ว

    Good job explaining how it works. I have a Utica boiler model PEG150BIDE with a VR8204A gas valve and a S8600M Honeywell control. I have a spark and a flame that lasts for a second and turns off and again a spark followed by a flame that lasts like a second, and it goes on and on, but no steady flame, is it a bad gas valve?

    • @acservicetechchannel
      @acservicetechchannel  7 ปีที่แล้ว

      Make sure to check your gnd wire, clean the ground where the flame touches the metal and brings the voltage from the rod to the metal nearby. Check to make sure that your pilot tube is tight as this also may be part of the ground. In reference to the gas valve, you can check if you are getting and then loosing the 24v signal from the ignition control thanks. It is likely a ground problem not proving the flame, thanks

    • @realuniversechannel1
      @realuniversechannel1 7 ปีที่แล้ว

      That's not necessary, I bought a new S86, as you suggested, and it works, you know what you are talking about, you are good at that man, thanks a lot and have a nice and happy thanksgiving with your family!

    • @realuniversechannel1
      @realuniversechannel1 7 ปีที่แล้ว

      One more question: that unit has a Safgard model VXT-24 automatic feeder with two wires coming from it (one white and the other orange), where those two wires are connected?

  • @keats182
    @keats182 6 ปีที่แล้ว +1

    Should I always get power to the pilot control? My furnace will not ignite. This control module seems like the most likely culprit but I'm not registering any power. Could it be something else?

    • @acservicetechchannel
      @acservicetechchannel  6 ปีที่แล้ว

      You would only get power to the pilot control once the safeties are connected such as the inducer motor or flame roll out, high heat sensor, thanks

  • @alanhelm2413
    @alanhelm2413 4 ปีที่แล้ว

    with excellent info from you i was able to get the boiler working but now the pilot lights -mv does not open and reads 14 volts any idea?

  • @analysispros
    @analysispros ปีที่แล้ว

    Thanks for your video - very good! I have an old Lennox G12 Furnace with a G60QHL interment ignition - I get a spark from the controller but its only for 35 seconds. I think you mentioned it should go for 90 or so. After 35 Seconds I hear a click and I think the controller shuts the pilot gas. I do smell gas so I know there is flow to the pilot during that time. My first question is - do you think the G60 controller went bad (its the original I think from 1980). My second question is - can that controller be replaces with a more modern one - if so which one to get? Thanks in Advance!

  • @KB-wq5bb
    @KB-wq5bb 4 ปีที่แล้ว

    Question? I was told by a plumber on the tankless hot water heaters to not use anything but a dollar bill to sand. Have you heard this or know if true. Thanks.

  • @bryandellinger2263
    @bryandellinger2263 7 ปีที่แล้ว

    Excellent explanation, I was working on a high voltage furnace ignition module 120 volts. the furnace would stay on for about 1 or 2 hours then the ignition module would fail and would work as you tapped it with screw driver is there something wrong with ignitor module ?

    • @acservicetechchannel
      @acservicetechchannel  7 ปีที่แล้ว

      Possibly, did you check the ground wire and connection, as well as take the connectors off, crimp them down and put them back on? Is the flame sensor steel wooled for a good signal strength?

    • @dennismphotographer
      @dennismphotographer 7 ปีที่แล้ว

      How do you determine if the spark rod is good or bad? New box but no spark....

  • @wolfofworldsan9988
    @wolfofworldsan9988 7 ปีที่แล้ว

    Your the best.

  • @GuillermoGarcia-on3yu
    @GuillermoGarcia-on3yu 7 ปีที่แล้ว +1

    Thank you for the video very good

  • @georgeEPC
    @georgeEPC 6 ปีที่แล้ว

    What happens if the rectification occurs directly through the HSI and NOT a separate flame sensor? Do you also test on at the ground of the control module and the unit on will be in warm-up?

    • @acservicetechchannel
      @acservicetechchannel  6 ปีที่แล้ว

      That is a tricky one on those old Rhuud rheem units. If you are having an intermittent problem then you could put a retrofit flame rod in place.

  • @phillipjoy8191
    @phillipjoy8191 8 ปีที่แล้ว

    Great videos

  • @ronlamb-strategy2execution110
    @ronlamb-strategy2execution110 3 ปีที่แล้ว

    This is by far the best explanation I've seen. Many thanks. I'd ask if there is a way to differentiate the problem, if you do get pilot flame going, but the main gas valve doesn't turn on. That is, since I don't get an MV voltage after pilot. Can I jump temporarily, 24 V to the MV line or disconnect the wires going to the MV connector, and give those wires 24v to see if the main valve will open and provide gas? Otherwise, I don't know if I have to order the Controller alone (no MV problem), or whether I also need to replace the main gas valve. It would be good to have a way to prove the value good / bad separate from the controller. Any procedure for this would be appreciated.

    • @101Parkside
      @101Parkside 2 ปีที่แล้ว

      Hi Ron, did you happen to fix your problem on your own or did you end up getting a furnace repair person in? What was the problem? If you see my question at or near the top of the comment section, it looks as though we both have the same issue? Look forward to hearing what it was. Cheers

    • @ronaldlamb9766
      @ronaldlamb9766 2 ปีที่แล้ว

      @@101Parkside funny to get this, as I did replace the controller and got it working myself, but shocked to find yesterday, that nothing working again. Blower yes, but no pilot, not attempt at starting, and no lights on the little LED's that are now standard on these controllers. I wish I remembered everything that I learned. Feels like I'm starting over :(

  • @rogerdelvenne1990
    @rogerdelvenne1990 ปีที่แล้ว

    Can some explain what he means by common for mv/pv