    Amazon Prime 30 Day Free Trial: amzn.to/3mqTcdq
    Fluke -A1-II Volt-Alert AC Non-Contact Voltage Tester: Amazon.com: amzn.to/13Tw7CY
    Fluke 117 Electricians True RMS Multimeter: Amazon.com: amzn.to/2s0aa70
    Leviton CS115-2W 15 Amp, 120/277 Volt, Toggle Single-Pole Ac Quiet Switch, Commercial Grade, Grounding, White: Amazon: amzn.to/2Xseiz8
    Installed in the video: Leviton 1221-2W 20-Amp, 120/277-Volt, Toggle Single-Pole AC Quiet Switch, Extra Heavy Duty Spec Grade, Self Grounding, White: Amazon: amzn.to/2K3SMKU
    Used in the video: Knipex Tools 13 88 8 US Electrical Installation Pliers: Amazon: amzn.to/2H2rxxm
    IDEAL 61-534 Digital Circuit Breaker Finder with Digital Receiver and GFCI Circuit Tester: Amazon.com: amzn.to/2ql9yYz
    Leviton 5621-2W 20-Amp 120/277-Volt Decora Plus Rocker Single-Pole AC Quiet Switch, Spec Grade, White: Amazon: amzn.to/2WUxu8r
    Leviton 1221-2W 2A, 120/277V Toggle Single-Pole AC Quiet Switch Spec Grade, White (10 Pack): Amazon: amzn.to/2WRP8tr
    IDEAL Combination Drill Tap Kit with SmoothStart Tips : Amazon: amzn.to/2pLDuyn
    DEWALT DCK278C2 ATOMIC 20-Volt MAX Lithium-Ion Brushless Cordless Compact Drill/Impact Combo Kit: Amazon: amzn.to/2ZJeHf9
    IDEAL Grounding Pigtails with Ground Screws (Pack of 50): Amazon: amzn.to/2REz8pa
    Wiha 30747 Insulated SlimLine Xeno Driver #2, 6.0mm Blade Diameter: Amazon: amzn.to/2ILWlUn
    EATON PJS1W Arrow Hart Pjs1 Mid Size Screw Less Wall Plate, 1 Gang, 4-7/8 In L X 3-1/8 In W X 0.08 In T, White: Amazon: amzn.to/2MwxAiv
    ENERLITES Screwless Decorator Wall Plates Child Safe Outlet Covers, Size 1-Gang 4.68" H x 2.93" L, Polycarbonate Thermoplastic, SI8831-W-10PCS, White (10 Pack: Amazon: amzn.to/2EZpZTr
    IDEAL Industries 61-164 SureTest Circuit Analyzer: Amazon: amzn.to/2Da3TwM
    Ideal 35-9305 Insulated Screwdriver Kit, 2 Piece: Amazon: amzn.to/2VIu2Nx
    Klein Tools 33532-INS Electrical Insulated Screwdriver Set of 2, 4-Inch Phillips andCabinet Set, Made in USA: Amazon: amzn.to/2H2fyjp
    Veto TECH OT-MC Veto COMPACT Open Top Tool Bag: Amazon.com: amzn.to/2rgC00e
    Klein Tools 935AB4V ACCU-BEND Level: Amazon.com: amzn.to/2ql7I9M
    DEWALT 65 ft Laser Distance Measurer DW065E: Amazon.com: amzn.to/2kKU8cv
    MagnoGrip 002-405 3-Pocket Magnetic Nail Pouch, Black: Amazon: amzn.to/2H3Wa4G
    Wiha 32092 Slotted And Phillips Insulated Screwdriver Set, 1000 Volt, 6 Piece: Amazon: amzn.to/2GRRfF7
    Circuit Breaker Finder Accessory Kit, Circuit Breaker Leads, Circuit Breaker Adapters Klein Tools 69411: Amazon: amzn.to/2XP7qsb
    VOLTCLAW-12 Nonconductive Electrical Wire Pliers: Amazon: amzn.to/2WzJF6J
    DEWALT DCF887B 20V MAX XR Li-Ion Brushless 0.25" 3-Speed Impact Driver: Amazon: amzn.to/2HOkWbs
    DEWALT DCV581H 18/20-Volt MAX Cordless/Corded Wet-Dry Vacuum: Amazon: amzn.to/2IiCJrz
    Amazon Prime 30-day Free Trial: amzn.to/2y8LjWo
    Create Amazon Business Account: amzn.to/2ShmuOW
    Try Prime Discounted Monthly Offering: amzn.to/3cZUaZw
    Try Twitch Prime “the world’s leading social video platform and community for gamers, video game culture, and the creative arts”: amzn.to/2WelD2C
    Try Amazon Home Services “quality pros and backed by Amazon's Happiness Guarantee”: amzn.to/3eZ1TsF
    Kindle Unlimited Membership Plans: amzn.to/3cZLQsB
    Amazon Prime Gift Membership: amzn.to/2Shs2ce
    Create an Amazon Wedding Registry: amzn.to/2WcnyVk
    Audible Gift Membership: amzn.to/3cWJ5s3
    Prime Video Channels Free Trials: amzn.to/2VNjY5d
    Amazon Family 30-day Free Trials: amzn.to/3cZFrO0
    Amazon Prime Music 30-day Free Trials. Our membership program offers special benefits including: *Unlimited, ad-free streaming of over a million songs *Instant streaming of thousands of movies and TV shows *FREE two-day shipping (no minimum order size) *Borrow Kindle books: amzn.to/2YfBwbJ
    Prime Student 6 month free trial: amzn.to/35eZoO8
    Baby Registry at Amazon: amzn.to/3f220Dv
    Saramonic UwMic9 96-Channel Omnidirectional UHF Wireless Lavalier Microphone System: Amazon: amzn.to/2Kc5qWe
    This video was edited with: Cyberlink PowerDirector 18 and PhotoDirector 11 Ultra: Amazon: amzn.to/2Qz2w1t
    To make this video I used the ZoMei Z818 Light Weight Heavy Duty Portable Magnesium Aluminium Travel Tripod: Amazon.com: amzn.to/1XOgA5T
    This video was made using the: Transcend 64GB Class 10 SDXC Flash Memory Card (TS64GSDXC10E): amzn.to/1w02Oxn
    Bill and sparkychannel.com are participants in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com

ความคิดเห็น • 372

  • @wolverine82nd
    @wolverine82nd 2 ปีที่แล้ว +14

    Bill I am a retired GC and EC from Calif. I built homes for over 40 years. I have watched many of the Electrical videos on You Tube and I have to say that your emphasis on safety is the best out there. Keep up the good work and keep the videos coming. People especially DIY'rs need to be aware of the danger when working with electricity. God bless you.

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว

      Thanks Jack! Yes, safety first! God bless you as well.

  • @rubbermallet3873
    @rubbermallet3873 3 ปีที่แล้ว +1

    👌thank you sir for this clear demonstration of skills and proficiency that i've been looking for all over the internet and is very confusing - to tellya the true - vs. the highly simple but concise technical explanation with all details involved that you offered in one shoot 👍👀🤠

  • @HoosierRallyMaster
    @HoosierRallyMaster 3 ปีที่แล้ว +2

    You edited out the part I really wanted to see - how to keep tension on the tape while trying to get under the screws. In most of your other videos you completely remove the screws, but in this one you left them in like us normal people :)

  • @johnstancliff7328
    @johnstancliff7328 3 ปีที่แล้ว +1

    I remember doing this on the same age home in California. Thankfully all the boxes were metal and grounded so, adding newer grounded outlets was easy. the wierd part about it is that back then, the ground was always #14. wire.... but the good thing was that at least we were able to update the outlets for modern use............and this was back in the late 1980's.... at least the electrician was thinking right!

  • @WalterKnox
    @WalterKnox 3 ปีที่แล้ว +35

    i love those old switches that give a nice solid click. i have no plans on changing them in my house.

    • @zarinacinemawala6296
      @zarinacinemawala6296 2 ปีที่แล้ว +2

      It is a heat tought memory

    • @trankt54155
      @trankt54155 2 ปีที่แล้ว +6

      Yes, and those switches are made of ceramic and thick brass (after daily use for 1/2 century and they are still working like a charm)---not some cheap plastic and thin metal strips, BUT when it comes time to sell your house and the young buyers (as clueless as they are) prefer new, "updated" switches because they don't care about functions and longevity but only cosmetics.....you know the usual with the new generations, forms are more important than substance..

    • @WalterKnox
      @WalterKnox 2 ปีที่แล้ว +5

      @@trankt54155 well, I am 18 so I won’t be selling it for a long time, the house was built in 1959 and has pretty much all original stuff and I have no plans on replacing anything that is not broken or causing issues. Even my fridge is from 1987

    • @trankt54155
      @trankt54155 2 ปีที่แล้ว +4

      @@WalterKnox My house was built in 1945 and everything was solidly made in the USA. The walls are all cement plastered....

    • @WalterKnox
      @WalterKnox 2 ปีที่แล้ว +5

      @@trankt54155 nice, keep it that way. It always makes me really sad to see some old house completely gutted and all cheap materials put in so someone would buy it. I wish more people would appreciate things like that. You can always build new cheap houses, but you can never make a vintage one again. Once they have all been ripped apart that is it.

  • @mikejean8957
    @mikejean8957 2 ปีที่แล้ว +1

    I was wondering why I was seeing neutral wires used as hots. 1979 build and now I'm feeling more confident taking on the switch change project. Thanks!

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว

      Excellent!

    • @Sparky-ww5re
      @Sparky-ww5re ปีที่แล้ว

      And that's why anytime a white wire is used as a hot it is supposed to be re-identified as a hot, by wrapping the end with black or red tape, heat shrink, or similar means. And a lot of 70s houses will have power run to a light fixture, with a single 14/2 cable dropped down to the switch, using the white as a hot, and the black as a switched hot.

  • @willhoward9190
    @willhoward9190 ปีที่แล้ว

    I enjoyed your video. Excelent job of explaining what you were doing. Keep it up!

  • @williamspiller5032
    @williamspiller5032 ปีที่แล้ว +1

    GREAT LESSON. THANKS FOR SHARING!

  • @DarkKnight-lq9cw
    @DarkKnight-lq9cw 3 ปีที่แล้ว +2

    Love your channel. Keep up the great work sir.

  • @37gcona65
    @37gcona65 3 ปีที่แล้ว +1

    You are a fantastic teacher. I moved into an 80 year old house. I cannot afford to pay for an electrician. So you are helping me immensely. I am trying to find a video where the old knob and tube insulated wires that are thick in diameter due to the corded wrapping wire insulation and are short in length and long so it is difficult to fit the outlet into the old boxes. It is difficult to fit the GFCI outlets into the box after attaching the wires to the outlets. Have you made a video that instructs how to handle these very old wires. Some wires are so short that I feel they need to be spliced to extend them. You are a very good electrician. I wish I had all the testing tools you use. Thank you, Gina

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +2

      Hi Gina! Bless you, it sounds like you have a wonderful house. From the sound of it I really think that your house needs to be re-wired. Or perhaps if that isn't possible perhaps one circuit could be re-wired at a time. Knob and tube wiring has reached the end of its useful life and needs to be replaced as soon as practical. Until then be as gentle as you can be with that old wiring. Best wishes!

    • @MarkLawry
      @MarkLawry 3 ปีที่แล้ว +3

      @@SparkyChannel That is exactly what I have. After living in this house 110 year-old house for 35 years, I am finally reworking the questionable circuits one at a time, like you have recommended here, and room-by-room. When a new service panel was installed well before I bought the home, they rewired all the visible wire in the basement with 3-conductor NM-B up to junction boxes where some K&T, and some 2-conductor wire went up the walls. My first step was to map the circuits and label the junction boxes. In many cases , it is easy to use the old wire to pull a new 3-conductor wire through the wall. Often it was just a 4 foot length of wire to replace. I am also replacing the small outlet boxes with fiberglass old-work boxes. My goal is to at least make each circuit safer with dual AFCI/GFCI breakers or AFCI breakers and GFCI receptacles, and to replace as much 2-conductor wire with 3-conductor with an equipment ground as I can. There are only a few circuits that will be beyond my ability to replace, and I will either hire an electrician to finish those, or use my map to disclose to the next owner. I am learning where I can be confident in the old wire, and where not. The old K&T is mostly in good shape. The problem is the 1950's wire which seems to have a much poorer quality of insulation.

  • @tkjazzer
    @tkjazzer 2 ปีที่แล้ว +2

    I'm going to add heat shrink around my cloth BX cables in the box where there is fraying and damage in the air exposed switch box. What color should I buy for the Line and Load wires in the switch loop to be 2021 compliant?

  • @msantana1502
    @msantana1502 10 หลายเดือนก่อน

    Excellent breakdown. Great video. Thank you.

    • @SparkyChannel
      @SparkyChannel  10 หลายเดือนก่อน

      Glad it was helpful!

  • @txikitofandango
    @txikitofandango 2 ปีที่แล้ว +2

    What if the box doesn't show close to 120 V when you compare it to the live wire? Then how could you ground the switch?

  • @ajducey1868
    @ajducey1868 ปีที่แล้ว +2

    I don't have metal boxes to screw the pigtail into. I'm trying to wire a lutron diva dimmer it comes with two red, one black and one ground. It's working with just the solid red and black wires connected. Do I really need the ground?

  • @kellenmadagan3712
    @kellenmadagan3712 4 หลายเดือนก่อน

    Great tutorial!

  • @ederflores2234
    @ederflores2234 2 ปีที่แล้ว +2

    I have a switch that requires a neutral, and I have the same wiring as you. What can I do?

  • @Carrollavirus
    @Carrollavirus 4 ปีที่แล้ว +5

    Hey Bill I’m glad you’re back!!!

    • @SparkyChannel
      @SparkyChannel  4 ปีที่แล้ว +1

      Great to hear from you!!! How are your Seahawks going to do this year?

    • @Carrollavirus
      @Carrollavirus 4 ปีที่แล้ว

      Sparky Channel
      Hi Bill In my opinion I don’t think the Seahawks are going to be that good at all this upcoming season, too many problems to list here lol
      Hope everything is going good for you!

  • @electriciantv5174
    @electriciantv5174 ปีที่แล้ว +2

    That’s one hell of a switch for just 1 light

  • @jenjones3035
    @jenjones3035 2 ปีที่แล้ว

    Nice job. Very professional. Thanks.

  • @tkjazzer
    @tkjazzer 2 ปีที่แล้ว +1

    I bought this exact switch. I couldn't fit the switch in the box without bending the tab that goes to the grounding screw on the switch. Is this common? What would you do? I have BX cable with grounded box. 1929. I am relying on the screws to metal box for ground. Is bending that tab ok?

  • @mdmyer
    @mdmyer 3 ปีที่แล้ว

    So the way you tell if the box provides a good ground is that multimeter test? Can outlets be grounded the same way with pigtails? I have an older house built in 1966 and it has those annoying 2 prong outlets in the older parts of the house.

  • @ronaldoleksy8264
    @ronaldoleksy8264 3 ปีที่แล้ว +2

    I have also run into Mercury switches. Not often. They show up once in a while

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +1

      Yes, they were very quiet.

  • @ayazkerimov3743
    @ayazkerimov3743 2 ปีที่แล้ว +1

    Trying to change 2 light switches to 1 power box. The power coming in from the breakers has 2 wires only (black & white, no ground). However, the wires going out to 2 switches have 3 wires each (black, white, red). How do I go about this? Thanks

  • @stefankyrytow4683
    @stefankyrytow4683 3 ปีที่แล้ว +1

    Can you do a series of videos on how to connect newer switches, lights and receptacles to older aluminum wiring?

  • @tyroneshoelace4872
    @tyroneshoelace4872 7 หลายเดือนก่อน

    Bill, I wonder if you can help me. I'm trying to replace a single pole switch, but I can't identify the "ground" wire. It's not clearly marked on the old switch. What can I do? I have photos...

  • @GregSr
    @GregSr 3 ปีที่แล้ว +3

    Yesterday I intended to install a dimming smart switch in the master bathroom. This house was built in 1990. Well, the new switch requires a neutral line to work. All I found in the box was ground, the hot (white) and the load (black) wires. NO neutral to be found. I know that is backwards of how it is done in newer houses. Apparently, back in the day, the electrician tried to save a few bucks and used only one Romex to the switch box. Therefore, no neutral was in the box. Luckily for me, there was a regular outlet about 18 inches away. I knew it would have a neutral. So, I ran a white 14 gage wire through the wall to bring a neutral to the smart switch. Bingo! The smart switch is working perfectly!

    • @godfreyappliance5585
      @godfreyappliance5585 3 ปีที่แล้ว +1

      Well there is really no need for a return (white-neutral) in a switch box. He or she should have put black tape or used a black marker to mark the white wire. Glad you got it done. The way it was done is how I have done it for 40 +years

    • @lordgarth1
      @lordgarth1 3 ปีที่แล้ว

      @@godfreyappliance5585 it’s been code since 2011 nec for exactly the reason above. An electronic control device.

    • @mook528
      @mook528 3 ปีที่แล้ว +2

      Just be sure that the neutral you tapped was on the same circuit.

    • @godfreyappliance5585
      @godfreyappliance5585 3 ปีที่แล้ว +1

      @@mook528 always do. 40+ years

  • @trankt54155
    @trankt54155 2 ปีที่แล้ว +9

    The switch that you are putting is actually self-grounding with the ground connecting to the metal strip that you screw into the metal housing box.......on top of that there is a brass on the lower screw to indicate that it is self ground.......you do not need to go through all the trouble of drilling the box to establish the grounding, etc......you could short cut the video to two minutes by informing the audience that there is already self grounding of the box (which you showed with you multimeter and that is VERY USEFUL piece of info. and I salute that) and the new switch you are putting in is a self grounding switch.......but if the viewers chose to get a non self-grounding then they can go through all the trouble you did....but you still do not have to drill the hole in the box but just screw the ground wire onto one of the existing screws already in there since it is attaching to the metal box... Hope this comment did not offend you. You DID provide an informational video though. Thanks and have a good day.

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว +1

      Thanks!

    • @mattd5719
      @mattd5719 2 ปีที่แล้ว +4

      True but still when it comes to electricity, redundancy are good. Say someone removes the switch without the turning the correct breaker off. Its still grounded. 2 minutes extra might just save a life.

    • @maxheadroom8857
      @maxheadroom8857 ปีที่แล้ว

      I have a couple of older boxes grounded from behind. My home is grounded under NEC code in 1955. On those boxes, is it legal to use a grounding clip to the metal box and jump a ground wire to the grounding screw on the switch?

    • @shieldcracker
      @shieldcracker ปีที่แล้ว

      ​@@maxheadroom8857 Yes. The clips are used whenever a tapped grounding point is not available in the box.

    • @grantcivyt
      @grantcivyt 7 หลายเดือนก่อน

      Using an existing screw would work electrically but would fail inspection. Ground screws must be exclusively for grounding. At least that's my understanding.

  • @Eddy63
    @Eddy63 4 ปีที่แล้ว

    Great vid Bill ... Gotta love those flathead screws ... Lol ...

    • @SparkyChannel
      @SparkyChannel  4 ปีที่แล้ว +1

      I saved them for you. LOL!

  • @cherrysdiy5005
    @cherrysdiy5005 4 ปีที่แล้ว

    Very professional :3
    But I'll show some love for the flathead screws. Especially if they sit flush. Easier for flush cover plates.

  • @GeometryWars
    @GeometryWars 3 ปีที่แล้ว +3

    This video really helped me out! We have a house built in 1961 that has grounding in the wiring itself, but the previous owners bonded it to a screw inside the box. Can I run the pig tail from the copper bond or should I still drill a tap into the box?

    • @maxheadroom8857
      @maxheadroom8857 ปีที่แล้ว

      You have a second alternative because your electrical is grandfathered: you can run a ground wire by attaching a grounding clip to the metal box edge and run a ground wire from the clip to the switch ground screw.

  • @jonhansen4745
    @jonhansen4745 2 ปีที่แล้ว +2

    Nice video. You forgot to add a link for the Scotch 33 black electrical tape...

  • @mgogmaj14
    @mgogmaj14 2 หลายเดือนก่อน

    I have a triple light box wired with the 2 wires and no ground. But my box is some kind of old plastic not metal. Do I need to ground? I am changing to rocker switches..Thanks

  • @brookepellechia7764
    @brookepellechia7764 2 ปีที่แล้ว +2

    Hi, Im replacing mine as well. can i leave the ground in the wall or since the new light switch has the ground screw, do i have to get grounding pigtails? (i believe i have a ground to the wall since theres open copper wire in the back of the box)

    • @grantcivyt
      @grantcivyt 7 หลายเดือนก่อน

      Same question. 🙂

  • @maxlaurent628
    @maxlaurent628 ปีที่แล้ว +7

    If the box is grounded, wouldn't the device still be grounded when the switch is screwed to the metal box or a ground wire is still needed?

    • @bsanchez3563
      @bsanchez3563 ปีที่แล้ว

      Not for a light switch/switch because with the metal type of wiring if its metal type meaning armoured cable that is enough if it is uninterupted between the ground whatever you decide to use for goround such as any metal continuoues with grounding/earth contact either a metal NOT gas/fuel type of pipe nor steam but only water cold water prefferably... pipe or else the rebar of enougj surface area within some concrete for the ground what is called a ufer ground if making a new install etc... however this is not what you should do if you ever are going to sell because if you try to sell then it may need to be certofied that it is built with the techniqies of a specific way or method for just about anything so if it is then you need to be careful more so with how you build.

    • @grantcivyt
      @grantcivyt 7 หลายเดือนก่อน

      I have the same question. I thought about adding a pigtail just to make things obvious, but I decided against it for no strong reasons.
      I'd like to understand the pros of the pigtail addition and whether it's a code requirement.

  • @MrBmoll5858
    @MrBmoll5858 3 ปีที่แล้ว +1

    Excellent job 👍👍very helpful Thank

  • @ccadama
    @ccadama 4 ปีที่แล้ว +2

    @Sparky Channel. Thanks for reposting the information.
    Question: If I have back stabbing receptacles and have a stock of back stabbing receptacles, should I only use the terminal screws in the future? And I take it the existing receptacles can remain in the wall until they really need to be replaced (the sockets are loose)?
    Hope you and your family stay safe and well.

    • @SparkyChannel
      @SparkyChannel  4 ปีที่แล้ว +1

      Yes, you inspired me to make a video to answer your question. :)

  • @Jimddddd1981
    @Jimddddd1981 3 ปีที่แล้ว +2

    I know it technically doesn’t matter which wire goes where on a single pole switch, but I was taught that the line side goes to the bottom terminal and the load side goes to the top so that’s the way I always wire it.

    • @prozay6856
      @prozay6856 3 ปีที่แล้ว

      That’s how I do it, even though not required. It’s good to have a method when installing devices.
      I hook the conductors onto the terminal, and keep line in the bottom, load on top for switches.
      Old school wiring can be confusing. Modern wiring makes installations better.

  • @terrydpierce2191
    @terrydpierce2191 ปีที่แล้ว

    Great video !!!

  • @BlockCylinder
    @BlockCylinder 2 ปีที่แล้ว

    I definitely learned a few things from this video. Thank you.
    I'm in a 30's or 40's 6-story building in Brooklyn, NY. I have a light switch in the bathroom that looks very similar to this. There are two wires, both with black fabric jackets, and one has some white paint on it. I'm hoping to get some kind of combination rocker switch / single outlet in there because there are currently no outlets in the bathroom at all.
    I can't access the area behind or around the switch box, and I'm not sure if it's grounded. Is there an easy way to check?

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว +1

      Please see about 2:30
      That is a test to see if your old metal box is grounded.

  • @arkie87
    @arkie87 ปีที่แล้ว +3

    IF your multimeter has a continuity check, couldnt you just check continuity between the case and the neutral wire, instead of turning the power back on?

  • @wim0104
    @wim0104 4 ปีที่แล้ว +1

    Yep, stripping old wire is a PAIN, compared to fresh new stuff. Thanks for showing the Knipex hybrid pliers in use: they are very fancy, but I'm worried about the length & "height" of the nose.

    • @wim0104
      @wim0104 4 ปีที่แล้ว

      my master would kill me if I used sharpie for black labeling?

    • @SparkyChannel
      @SparkyChannel  4 ปีที่แล้ว +1

      Yes,, wires from the 1960's don't strip like the new wires. The Knipex is the best that I've found for the job.

    • @SparkyChannel
      @SparkyChannel  4 ปีที่แล้ว +1

      You could look it up in the old 2008 NEC. Those wire wires had to be indelibly color coded. Red would work too, or black or red electrical tape.

  • @carolhu6590
    @carolhu6590 ปีที่แล้ว +2

    I have the same wiring in my house, I want to upgrade to a smart switch, which requires hot in, hot out, neutral and ground. Is there a way to make it work?

  • @Jram1292
    @Jram1292 3 ปีที่แล้ว

    So it won’t work if it’s not grounded? I changed out my switch but it didn’t have a ground wire or the green screw. But on the new one I put in it does . So would I have to do what u did n ground it?

    • @armdelgado
      @armdelgado 3 ปีที่แล้ว

      Now with the new LEDs, some iluminaries need fisical ground to work property, meaning nos flasing when they are turn off.

  • @garydudgeon
    @garydudgeon 4 ปีที่แล้ว +1

    Good video Sparky.

  • @roul3688
    @roul3688 2 ปีที่แล้ว +2

    My switch recently broke. When I removed it, the ground wire was just floating in the box. My new switch has a ground screw. Can I just attach the ground to the switch?

  • @Vanilla_Icecream1231
    @Vanilla_Icecream1231 2 ปีที่แล้ว +2

    house bulit in the 70 almost always got power from the light jumction box

  • @MarioRodriguez-en1qv
    @MarioRodriguez-en1qv 4 ปีที่แล้ว

    Thanks Bill!!!!

  • @stevebuchanan5773
    @stevebuchanan5773 4 ปีที่แล้ว +3

    What do you do if the box isnt grounded while doing a device change out

    • @SparkyChannel
      @SparkyChannel  4 ปีที่แล้ว

      This box wasn't grounded: How to Replace 2 Switches: 3-Way and Single Pole When You Have No Ground per NEC 2020: th-cam.com/video/go6ri_CHmac/w-d-xo.html

  • @Aepek
    @Aepek 4 ปีที่แล้ว

    Glad to see ya again; for some reason you were deleted from my subscriptions after I updated TH-cam few weeks back. Not sure what happened, but glad I got you back👍🏻
    Hope doing well as “can be”....
    Catcha L8R ✌🏼

    • @SparkyChannel
      @SparkyChannel  4 ปีที่แล้ว

      Aepek! Great to hear from you! My channel got hacked and I lost 934 videos, 182K subscribers and 65 million total views. Easy come easy go huh? Anyway, so glad to hear from you and thanks for re-subbing. Catcha L8R ✌🏼

    • @Aepek
      @Aepek 4 ปีที่แล้ว

      Sparky Channel that’s horrible, but does explain why I “lost” you.....
      Ppl can be horrible some times; but than.....surprise ya & be “great” the next....
      Sorry to hear this happened; it glad your back in my feed again😊

    • @user-lq5oj5zb4k
      @user-lq5oj5zb4k 3 ปีที่แล้ว

      ''أnMj

  • @robertbrown7466
    @robertbrown7466 3 ปีที่แล้ว +1

    My house was built in the 50s and has a lot of these switches for exterior lights. How do you tell how many amps the new switch should be?

    • @armdelgado
      @armdelgado 3 ปีที่แล้ว +2

      the switch that sparky used, was for 15-20 amps, remember if your cables are 14 awg use 15amps, if you have 12awg wire use 20amps switch, but also you can see the breaker panel of that circuit and you will see.

    • @b.n.c.v5792
      @b.n.c.v5792 2 ปีที่แล้ว

      My apartment was built in 1962

    • @TechHowden
      @TechHowden 2 ปีที่แล้ว

      Any normal light switch will work

  • @seattlebest79
    @seattlebest79 2 ปีที่แล้ว +3

    Is that necessary all the time to install a grounding wire? Thank you

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว +1

      Not if you use a switch with a self-grounding clip. Redundant grounds are a good thing though.

    • @dannybrazil3986
      @dannybrazil3986 2 ปีที่แล้ว

      @@SparkyChannel I have the vintage 2 wire electrical system when replacing the light switch say the metal box isn't bonded , do I add a pig tail ground from the switch to the metal box ? Or will that create a short?

  • @jessm1638
    @jessm1638 3 ปีที่แล้ว +1

    I was trying to change the 2 prong outlet to a 3 prong, but realized it didn’t have a ground wire. It had a metal box, and when I did the test with the multimeter(one lead to the hot, and the other to the box…I only got like 60). Does that mean it’s not grounded? The box was also coated in paint and plaster…could that affect my reading??

    • @robinsymonds5353
      @robinsymonds5353 3 ปีที่แล้ว

      That's a back feed through the neutral correct?

    • @shieldcracker
      @shieldcracker ปีที่แล้ว +1

      Paint and plaster can affect your readings. Scratch the box with a screwdriver and measure again, values less than line voltage means the box is not grounded.

  • @apackwestbound5946
    @apackwestbound5946 ปีที่แล้ว

    Thank you again.

  • @callmepolmz
    @callmepolmz 3 ปีที่แล้ว

    We dont have grounding pigtails here in ph, can i buy an solid awg cable and screw?

    • @armdelgado
      @armdelgado 3 ปีที่แล้ว

      yes, green wire not cable

  • @trankt54155
    @trankt54155 2 ปีที่แล้ว +1

    Good video. One question, you have two metal screws there attaching to the metal box , why don;t you remove one and screw the ground onto it? Why do you need to drill a new hole on the metal box?

    • @SparkyChannel
      @SparkyChannel  2 ปีที่แล้ว +1

      Those screws should never be touched as they connect a ground wire to the back of the metal box. This is the old style 50's 60's grounding system.

  • @roccomiller2647
    @roccomiller2647 11 หลายเดือนก่อน

    I love your videos! My family just painted rhe house and now i am replacing all the ugly yellowish light switches from the 1950s/60s… i just found one that has wires fitted on the TOP of the little box instead of the sides. Do you know what style that is??

  • @cantweallgetalong
    @cantweallgetalong 2 ปีที่แล้ว

    My boxes were all that old resin black boxes and the only ground was a red wire strapped to the cold water pipe at the kitchen sink and laundry. Naturally when the house was re-piped from galvanized to copped, those grounds were suddenly missing.

    • @tkjazzer
      @tkjazzer 2 ปีที่แล้ว

      Copper would ground. So they didn't reattach the grounding wire?

    • @cantweallgetalong
      @cantweallgetalong 2 ปีที่แล้ว

      @@tkjazzer No, they were apparently not concerned about reattaching the ground wire, because the connection was a pipe clamp located in the attic, in a very small confined area that the new copper pipe was not close to. And I found the only three prong outlets were the garbage disposal and the washer and dryer outlet. These two had a #12 red wire ground attached to the adjacent galvanized old pipe inside the inaccessible wall cavity.
      But, it would have been nice if the plumbers had notified me of the abandoned ground attachments for these two outlets before they closed the wall they had opened up for the new pipes. Because I had to cut holes to fish new romex to ground them. I initially ran a single #10 ground wire from the panel into a junction box in the attic to ground those two outlets and left all the other outlets and wire alone. But after a kitchen remodel, it made sense to rewire all the kitchen outlets when the walls were opened up and then it snow balled, because I had to open the drywall to get access to the back of the panel. And then since that was open......

    • @cantweallgetalong
      @cantweallgetalong 2 ปีที่แล้ว

      @@tkjazzer I always thought that the way they would ground the panel was with a # 6 wire to the water service where it first hits the house, providing they used a galvanized pipe in the ground and not pvc, but my house had the panel grounded to the galvanized cold water pipe in the very confined attic area. It was probably easy to get to when they did it, before the drywall was installed in the ceiling.

  • @whadat2000
    @whadat2000 2 ปีที่แล้ว

    I have an old switch box just like that which I want to change to a newer box...is it nailed to a stud?..how would I go about replacing it.

    • @normferguson2769
      @normferguson2769 2 ปีที่แล้ว

      If installed during original construction it is likely nailed on the outside. You can run an oscillating saw blade between the 2x4 and the box to cut the nails (instead of breaking up the drywall).

    • @ronzek3207
      @ronzek3207 ปีที่แล้ว

      Why change it if it works?

  • @origamiandcats6873
    @origamiandcats6873 ปีที่แล้ว

    How could you make a combo switch and outlet with something like this?

    • @SparkyChannel
      @SparkyChannel  ปีที่แล้ว

      Yes. Check out this video: Read Plans and Add Devices to a Circuit: How to Add a Combo Switch/Receptacle and Light: th-cam.com/video/JS-tWq10-Yo/w-d-xo.html

  • @JGillis__
    @JGillis__ 4 ปีที่แล้ว +1

    I just bought a house built in 1955, and it appears the wiring is from around then too. How can you tell if the box is grounded or not? I have mostly 2 "prong" outlets, and would like to replace those with new grounded ones

    • @Nick-bh1fy
      @Nick-bh1fy 4 ปีที่แล้ว

      Chances are if your house is that old without any EGC the box itself won’t be grounded but if you want to check you can use a multimeter and set it to measure continuity (resistance) of the box

    • @yankkesrule
      @yankkesrule 3 ปีที่แล้ว

      He just showed you in this video how to check for a grounded box

    • @Sparkchaser1
      @Sparkchaser1 3 ปีที่แล้ว +1

      Replace with GFCI receps.

  • @SaratogaJerry
    @SaratogaJerry 4 ปีที่แล้ว +1

    Yay! House Renovation Time returns! BTW, I was also a victim of (silent/secret/evil) subscription deletion. I've been replacing some switches and receptacles lately. Any hints for dealing with old and super stiff wires? Also, I love that you use the industrial-strength version of the switch - I do the same (Leviton Decora line). Again, any hints for getting these bulkier devices in small boxes?

    • @SparkyChannel
      @SparkyChannel  4 ปีที่แล้ว +1

      Hi Jerry! Great to have you back!!! I think it's awful the way all the subscribers got deleted with no notice! I've tried many times to get through to TH-cam but they just ignore me. Oh well, it is what it is and it's time to just move forward and celebrate the good things like your finding Sparky Channel again. Yeay!!

    • @tkjazzer
      @tkjazzer 2 ปีที่แล้ว

      I had to bend the ground screw tab while screwing it in and it bent the switch. Can't really notice but plate is slightly off now. Would love to hear his tips on this issue

  • @josianrodriguez1249
    @josianrodriguez1249 4 ปีที่แล้ว

    NICE JOB WELL DONE.

  • @psingone
    @psingone หลายเดือนก่อน

    interesting and thanks for sharing. I ran into this on my grandparents house but the switch box is black and plastic

  • @hondaland_
    @hondaland_ 3 ปีที่แล้ว

    Thank you

  • @hammerridecycling7630
    @hammerridecycling7630 2 ปีที่แล้ว +1

    hi,im planning on replacing my switch on my 1960 house but the wires are both hot.why is it?

    • @anhtuanb
      @anhtuanb 2 ปีที่แล้ว

      Sounds like you may have a short in the system. You need to trace it where the true Hot wire from and check all those receptacle and switches that leading up to the switch you're replacing.

    • @emmettturner9452
      @emmettturner9452 2 ปีที่แล้ว

      Maybe it is switching 240v?

  • @captainteamcarry3
    @captainteamcarry3 3 ปีที่แล้ว

    Those switches from the 60s just sound better.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +2

      LOL! Yes they do. Except at night when you're trying to sleep. :)

  • @apagan65
    @apagan65 19 วันที่ผ่านมา

    Hi Mr. Sparky. I have an old style, single pole light switch, but it has the screws on the top of the receptacle instead of the sides. It has a metal box with only two wires.This house is very old. I turned off the power, but it still lit up my electric detector. What can I do? I don't want to get shocked! Thanks so much!

  • @skunkbri
    @skunkbri 3 ปีที่แล้ว +1

    Love your videos but if the box is flush and if you have self grounding yoke and you have both than article 250.146B contact device or yokes designed and listed as self grounding shall be permitted in conjunction with supporting screws to establish equipment bonding between device yoke and flush type boxes

  • @dougstopera4820
    @dougstopera4820 7 หลายเดือนก่อน

    I have an old switch that is not working. it has 4 wires. 2 are hot and 2 are not. Took the switch off to expose the wires to confirm I had 2 hots. I flipped the breaker and both hots went of so they are the same circuit. Why would I have 2 hots on 1 switch? Any ideas?

    • @morethanblackandwhite
      @morethanblackandwhite 7 หลายเดือนก่อน +1

      Sounds like a 4-way switch. Many diagrams can be found through your favorite search engine. "Four-way switches are used to control lighting from three or more locations."

  • @luvnepal7434
    @luvnepal7434 7 หลายเดือนก่อน

    How can i install dimmer switches with black and white wires?

    • @warriormanmaxx8991
      @warriormanmaxx8991 6 หลายเดือนก่อน

      Look up a tutorial here on TH-cam - there are plenty of choices.

  • @susanhurst3292
    @susanhurst3292 ปีที่แล้ว

    How about how much is the charge for just this change out and how long did it take you?

    • @SparkyChannel
      @SparkyChannel  ปีที่แล้ว +1

      Depending on your electrician, a simple light switch replacement can cost between $50 and $150. It takes about 5 minutes.

    • @ronzek3207
      @ronzek3207 ปีที่แล้ว +1

      Do it your self, In this case It was not necessary to add the green ground wire, switch is grounded to the metal grounded box with the switch mounting screws, He over did it.

  • @peterscozzafava1253
    @peterscozzafava1253 ปีที่แล้ว +2

    when replacing ro new swirch,do you have to add new ground even though there wasn't one before?

    • @ronzek3207
      @ronzek3207 ปีที่แล้ว

      No, box in video was already grounded, switch mounting screws will ground switch to box.

  • @MrSilvervw
    @MrSilvervw 2 ปีที่แล้ว +1

    Great content 👌 👏 👍

  • @martindriver6026
    @martindriver6026 3 ปีที่แล้ว +1

    Changed out switches in my inlaws house because there kitchen light would strobe. The switch was a ceramic type. Changed out problem fixed.

    • @armdelgado
      @armdelgado 3 ปีที่แล้ว

      Now with the new LEDs, some iluminaries need fisical ground to work property, meaning nos flashing when they are turn off.

    • @tkjazzer
      @tkjazzer 2 ปีที่แล้ว

      @@armdelgado what is fisical ground?

    • @armdelgado
      @armdelgado 2 ปีที่แล้ว +1

      @@tkjazzer physical ground

  • @mts7274
    @mts7274 ปีที่แล้ว +3

    So how would you ground it when there is no ground attached to the metal box?

    • @YourEyesTheyLie
      @YourEyesTheyLie ปีที่แล้ว

      Did you not watch this video where he adds a ground wire?

    • @mts7274
      @mts7274 ปีที่แล้ว +9

      @@YourEyesTheyLie Did you not read my comment? I asked how to ground it when there is NO GROUND attached to the metal box.

    • @YourEyesTheyLie
      @YourEyesTheyLie ปีที่แล้ว

      @@mts7274 Exactly, he adds a ground wire to the metal box. Is that not what you want?

    • @mts7274
      @mts7274 ปีที่แล้ว +11

      @@YourEyesTheyLie Good lordy... what if there was never a ground wire run to the back of the metal box? Older homes don't always have grounded receptacles. The box has to already be grounded, if you intend to ground a new switch or a new outlet.

    • @YourEyesTheyLie
      @YourEyesTheyLie ปีที่แล้ว

      @@mts7274 Your original question wasn't detailed like your last response. Check the box for grounding by using a voltage meter. Touch one end of the tester to the hot (black wire) and the other to the inside of the box. If you have voltage, then it's grounded - that's when you can add a ground wire. If not, you'll have to replace the box.

  • @aaron74
    @aaron74 3 ปีที่แล้ว +2

    How come you replaced this snap switch with a spec switch instead of just a cheap resi switch? Also, instead of tapping a new hole for a ground screw, you can remove the bottom clamp that wasn't being used for anything. It uses a 10-32 screw, just like ground. Removing that unneeded clamp also gives you more wire-fill, also a good thing!

    • @mook528
      @mook528 3 ปีที่แล้ว

      Was also wondering why he used an industrial spec switch.

    • @jrbay1
      @jrbay1 3 ปีที่แล้ว

      Was wondering why he bothered to run the ground when it’s self grounding switch And the box was already grounded

  • @AssemblerGuy
    @AssemblerGuy 3 ปีที่แล้ว

    Curious question from an electronics ("I don't like fiddling with anything above 50 volts") guy: What's the difference between an electrician's meter and the kind of digital multimeters used for low-voltage electronics? The one you're showing in this video looks very much like what we use in an electronics workshop, but does it have special functions pertaining specifically to an electrician's work?

    • @TheHoss4145
      @TheHoss4145 3 ปีที่แล้ว

      Lol, you really have no clue, don't you? Can not be even much of an electronics guy if you asks these questions.

    • @jrbay1
      @jrbay1 3 ปีที่แล้ว +3

      Generally Electrician’s meters are normally rated for higher voltage and safety classes ; also true rms voltage measurements since we deal with AC on polyphase systems which will tend to give you strange ghost voltage readings with a non-RMS meter, and my higher end fluke meters have higher resolution to measure pulse modulated DC voltage and frequency something that a electronics guy really wouldn’t need to do unless he’s doing engineering or very high level bench work.

    • @AssemblerGuy
      @AssemblerGuy 3 ปีที่แล้ว

      @@jrbay1 Thanks for your useful answer ☺

  • @DeeDee-rr3sn
    @DeeDee-rr3sn 4 หลายเดือนก่อน

    Hi, how can you tell that, that metal box is actually grounded?

    • @JoeDiTrapani
      @JoeDiTrapani 4 หลายเดือนก่อน +3

      The voltage test at 2:20. An ungrounded box will not have a return path for the current so the voltage reads 0 (or close to it).

  • @ghostridergale
    @ghostridergale 3 ปีที่แล้ว

    I can never find these links you refer to, where the hiding at? Anyone know?

    • @The_10th_Man
      @The_10th_Man 3 ปีที่แล้ว +1

      In the video description

  • @G-Ovalle
    @G-Ovalle ปีที่แล้ว

    Can those switches be used in residential homes ?

  • @peglegthered
    @peglegthered ปีที่แล้ว

    That door trim and stucco looks like just the 1960's Escondido home I just bought. Planning to swap out all the outlets and switches to decora.

    • @SparkyChannel
      @SparkyChannel  ปีที่แล้ว +1

      I wouldn't doubt it because I live in San Diego. Excellent idea!

  • @samsen3965
    @samsen3965 2 ปีที่แล้ว

    3:33 Is that tiny gauge silver wire (Aluminum) that you call "Grounding wire"? and aren't they supposed to be "Cupper" and larger caliber, say 18, possibly 16, or better gauge to comply with the code and pass inspection?

    • @joshhudson5560
      @joshhudson5560 2 ปีที่แล้ว +1

      Codes very per state per county the I.R.C. is a guide line then towns set there codes

    • @emmettturner9452
      @emmettturner9452 2 ปีที่แล้ว +1

      This is old. There was a time when they weren’t “supposed to be” anything. ;)

  • @ryanemerson7
    @ryanemerson7 2 ปีที่แล้ว

    I need to ground a light switch from a plastic box. Is there a hack instead of rewiring back to the panel? 🤷🏻‍♂️

    • @lhotse8615
      @lhotse8615 2 ปีที่แล้ว

      This is the easiest way to ground a light switch. It doesn't mater ifnits metal or plastic at least not to my knowledge.

    • @Minion0ne
      @Minion0ne 2 ปีที่แล้ว +1

      @@lhotse8615 the metal box will conduct the electricity to the grounding wire. the plastic box will act as an insulator and connecting a ground wire directly to it will do nothing.

    • @jeanmcallister961
      @jeanmcallister961 2 ปีที่แล้ว +1

      I dont know how old this thread is but in old houses don’t bother.

  • @claudiaoctavia6340
    @claudiaoctavia6340 3 ปีที่แล้ว +5

    but what if the boxes arent grounded?

    • @TechHowden
      @TechHowden 2 ปีที่แล้ว +1

      Then just don’t connect to the ground wire but since it’s not grounded you have to use a cover plate it does not have any metal on it

  • @armdelgado
    @armdelgado 3 ปีที่แล้ว +1

    @Sparky Channel
    Im electrician in texas, and I have seen electrician in Austin that they use the electrical screwdriver "bosch go2", what do you think about that tool for electricians?

  • @MrTooTechnical
    @MrTooTechnical 4 ปีที่แล้ว

    Great vid. Why did u put the federal spec not the decora plus?

    • @SparkyChannel
      @SparkyChannel  4 ปีที่แล้ว

      I thought it might be less confusing for the tenants.

    • @MrTooTechnical
      @MrTooTechnical 4 ปีที่แล้ว

      @@SparkyChannel this your rental property to make money for the apocalypse. damn!

    • @MOETHANKS
      @MOETHANKS 3 ปีที่แล้ว

      @@SparkyChannel opq

  • @njwags95
    @njwags95 3 ปีที่แล้ว

    Does a ground wire have to be the same gauge as wire?

  • @odie77301
    @odie77301 2 ปีที่แล้ว +5

    Why do you need a ground?

    • @barrelsdean6004
      @barrelsdean6004 ปีที่แล้ว +2

      To avoid getting electrocuted

    • @wigletron2846
      @wigletron2846 ปีที่แล้ว +3

      You don't need one, it just helps prevent shorts

  • @derrickbonsell
    @derrickbonsell 2 ปีที่แล้ว

    I prefer the "screwed" look on switch and outlet covers myself.

  • @Leeproeun
    @Leeproeun 3 ปีที่แล้ว

    Thanks

  • @helenkiflu5292
    @helenkiflu5292 3 ปีที่แล้ว

    Hi! Do you work on homes? And if so what state?

  • @theredrover3217
    @theredrover3217 3 ปีที่แล้ว +1

    I wish you mentioned the red flashes when checking the wires - what does that mean? I get that sometimes and freaks me out. I have watched countless videos it never seems to happen to anyone else or anyone mention it could. I do feel better now seeing it didn't faze you one bit. 😏
    I got a Fluke by the way and that helps too but I wish I could find somewhere explaining why that didn't seem to bother you any and what exactly does it mean.

    • @VinierrhinoGaming
      @VinierrhinoGaming 3 ปีที่แล้ว +2

      Red blink every few seconds is to let you know the tester is on.

    • @sickbassdrop
      @sickbassdrop 2 ปีที่แล้ว

      If you bump the testers hard enough they will give you a false indication. You're looking for sustained indication. That lets you know that it is hot.

  • @theflash9040
    @theflash9040 4 ปีที่แล้ว +1

    how do you change a stove outlet

    • @chasefouse684
      @chasefouse684 4 ปีที่แล้ว +2

      Pretty similar to this. Buy the right one, turn off power, test to make sure it's off, take out the old switch, read the paper that comes with the new switch which will tell you how to wire it. Then turn the power back on and test it with your meter.

    • @mook528
      @mook528 3 ปีที่แล้ว

      The same way you change any other outlet. hot to hot, neutral to neutral, ground to ground.

  • @kvdgadj
    @kvdgadj 4 ปีที่แล้ว +1

    The white wire is the live line and the black is the negative line?

    • @cherrysdiy5005
      @cherrysdiy5005 4 ปีที่แล้ว

      Because the conduit (Romex type wiring) is bundled. Both wires are used as hot. It's code nowadays to mark the neutral wire as Hot for use with single pole switches.

    • @Nick-bh1fy
      @Nick-bh1fy 3 ปีที่แล้ว +1

      There’s no positive and negative in ac electricity

    • @armymobilityofficer9099
      @armymobilityofficer9099 3 ปีที่แล้ว +2

      The white line (marked black) is the line wire. The black wire is the load wire.

    • @mook528
      @mook528 3 ปีที่แล้ว

      With switches yes, but it's supposed to be marked as hot.

    • @illestofdemall13
      @illestofdemall13 3 ปีที่แล้ว +1

      No, the white in this case is the line, and the black is the load, also called the switch leg. The switch is just internally shorting the 2 wires together in order to close the circuit. There is no such thing as a negative in AC wiring. You are getting confused with neutral, which would be a white wire that will be needed in the box for a receptacle. Switches don't "need" a neutral in order to operate, but the new code requires switch boxes to contain the neutral.

  • @omegawolf6982
    @omegawolf6982 3 ปีที่แล้ว

    Would ordinary copper wire work for grounding?

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +1

      Yes but I prefer using the green ground wire.

    • @mook528
      @mook528 3 ปีที่แล้ว

      That's usually what you see in the box unless you are adding a pigtail.

  • @bigbranch1
    @bigbranch1 ปีที่แล้ว

    So if your wires are short...can you pull the pushin wires out??????

    • @SparkyChannel
      @SparkyChannel  ปีที่แล้ว

      Yes, if there is some play in the wires behind the box you may be able to pull some more out to solve the problem.

    • @tonywagner4836
      @tonywagner4836 ปีที่แล้ว

      If you are talking about pulling the wires out of the back of the receptacle the answer is yes. There is normally a second hole adjacent to the one the wire is in. Push a wire or fine screwdriver blade in that hole and the wire will release. One thing to look out for is deep nicks in the exposed copper wire.
      It is also ok to put a pigtail extension on the wires.

  • @willking9721
    @willking9721 3 ปีที่แล้ว +1

    Isn’t that a self grounding switch ?, I’ve watched other videos you posted and believe you don’t need the ground pig tail. Please correct me if I’m wrong.

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว

      I like to use both the EGC and the self grounding clip. Then you have redundant grounding methods.

    • @pcar5
      @pcar5 3 ปีที่แล้ว

      @@SparkyChannel Which makes no sense.

    • @ronaldarchibald2506
      @ronaldarchibald2506 3 ปีที่แล้ว +2

      @@pcar5 if you removed the switch while energized the redundant ground provides a path of equal potential to ground should a fault occur. If the device has a provision for ground use it.

    • @tkjazzer
      @tkjazzer 2 ปีที่แล้ว

      @@ronaldarchibald2506 thank you, I finally understand why he is doing it.

  • @sirenfan97
    @sirenfan97 3 ปีที่แล้ว +10

    Doubt the new stuff will last 60 years

    • @SparkyChannel
      @SparkyChannel  3 ปีที่แล้ว +7

      Oh, believe me, the cheap switches we have today don't make it to 5 years sometimes. You can still buy quality switches that will last a lifetime though.

  • @utopia2112
    @utopia2112 3 ปีที่แล้ว +1

    Sparky, you didn't exactly explain WHY you used the meter - you said "to make some important tests". It seems like your test verifies that the box IS grounded so adding a pigtail to the back of the box to ground the switch is OK to do. What would the meter have shown if the box WASN'T grounded and what should one do about that? Should they just install a switch without a ground wire/pigtail?
    I love your vids, I just need you to go a little bit farther in your explanation on this. Thx!

    • @utopia2112
      @utopia2112 3 ปีที่แล้ว

      I think the answer is supplied - but the point not really driven home - in this other Sparky video: th-cam.com/video/H-2ETtDBu9s/w-d-xo.html

    • @ghostridergale
      @ghostridergale 3 ปีที่แล้ว +2

      If the box not grounded or the box isn’t metal! Then you need to run a ground to like a metal plumbing pipe. They have ground connectors for hooking to plumbing pipes you can buy.. but normally you don’t need a ground on a light switch and many don’t have one either! Where the problem comes in not having the ground on your light switch is many of these new smart plugs or light switches do require a ground wire and they won’t work without a proper ground! If your box is plastic and there’s only the power and load wires connected. I don’t even worry about shutting the power off. You can’t get shocked unless there’s a ground or return wire in the box too or maybe if your standing in a tub of water? LOL Worse thing that happens if those two wires touch with the power on is your light turns on! LOL This older home with the metal box being grounded more understandable turning the power off first though, especially working with old wiring you never know where the wire insulation might be wore off?

    • @mook528
      @mook528 3 ปีที่แล้ว +1

      @@ghostridergale right, I only worry about grounding a switch if there is an available ground, if not then whatever. It's just one leg of a hot wire.

  • @moonglow1158
    @moonglow1158 2 ปีที่แล้ว +1

    Where did you get the new switch?