  • @zodosbowling9947
    @zodosbowling9947 5 ปีที่แล้ว

    What is the operating RPM range of the cleaner pump motor? We've had to boost the RPMs more than usual the past couple of weeks to maintain proper cleaner output (we calibrate weekly), yet we are still about 3 1/2 months away from the 1-year norprene tubing replacement interval. I'm curious if I have enough RPMs left to delay tubing replacement til the end of the winter season in a few weeks. Kegel IKON, 24 lane house.

    • @KegelBowling
      @KegelBowling  5 ปีที่แล้ว

      The cleaner pump motor is controlled by changing the voltage to the motor through the analog controls on the touchscreen. The maximum value that can be entered is 4000. It is possible that you have enough range left to prolong the changing of the tube, however what you are experiencing is typically a key indicator that replacement is needed.