What i would do in their place is purge it with nitro by brazing on charge ports onto coil.. not that it would be easy coper to aluminum. But if you do, you wont have tp flush the system
Hi I noticed in the video you had a low side leak. Wouldn't the compressor need to be changed out as well due to contamination with non-condensable in the system. Would the oil have moisture/water in it now? Just curious I could be wrong.
This is too professional.. I have a leake in the evaporator coil of big 3 doors commercial freezer. The leak stop liquid l/gas could not seal it. I was told that I have to replace it. But $1500 is too much. 8s there a way to repair it and what the approximate risk percentage pls?
If there is a leakage how come you see the ice built up there? If it leakage means no freon and if there is no freon there is no cool. So I can easily till you that there is a blockage or restriction
you guys didn't replaced drier filter. and you need make sure heater is not touching evap coil. i use metal zip ties from Harbour Freight to secure heater away from heater.
6:39 scratchy moment. I would put a thermal barrier on the plastic wall.
My good fellow Tech, like this repair you did, awesome job; notice your flame is very little , you main to share the type of your using?
What are you using to thaw the ice out?
Good job bro amijo
Thank you so much for your videos brother.
how do you find the leak?
Do you have nitrogen and a brazing torch kit?
What i would do in their place is purge it with nitro by brazing on charge ports onto coil.. not that it would be easy coper to aluminum. But if you do, you wont have tp flush the system
Hi I noticed in the video you had a low side leak. Wouldn't the compressor need to be changed out as well due to contamination with non-condensable in the system. Would the oil have moisture/water in it now? Just curious I could be wrong.
No , compressor is ok , there is no need to replace it, but if you feel more comfortable to replace it you can do that too 👍
Yes it does you had a low side leak you have moisture in the compressor oil. Your going to get more restrictions or the compressor is going to go bad.
This is too professional..
I have a leake in the evaporator coil of big 3 doors commercial freezer. The leak stop liquid l/gas could not seal it. I was told that I have to replace it. But $1500 is too much. 8s there a way to repair it and what the approximate risk percentage pls?
If there is a leakage how come you see the ice built up there?
If it leakage means no freon and if there is no freon there is no cool. So I can easily till you that there is a blockage or restriction
Are you in Houston? I have a refrigerator that isn't cooling. I'm in Spring Branch. I couldn't find your business phone online.
👍
Thank you 🙏🏼
Sir,
How do you price your jobs? Do you have a chart?
Bu dolap en boktan marka olan Samsung marka mı?
put hot water instead of doing this.
you guys didn't replaced drier filter. and you need make sure heater is not touching evap coil. i use metal zip ties from Harbour Freight to secure heater away from heater.