Mastering Ansys: Sound absorption coefficient with JCA model

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ธ.ค. 2024

ความคิดเห็น • 25

  • @SumandeepSinghRana
    @SumandeepSinghRana 4 หลายเดือนก่อน +1

    Hi sir, i am learning from this but if i change the material property of my sample, the results are not changing. Both air and sample are part of acoustic region. Should i select sample also when i am creating port. thank you

    • @caewitharminhashemi
      @caewitharminhashemi  4 หลายเดือนก่อน +1

      Hello. The absorption coefficient in the JCA model depends on five parameters. If you adjust any of these parameters, the results will change accordingly.

    • @SumandeepSinghRana
      @SumandeepSinghRana 3 หลายเดือนก่อน +1

      @@caewitharminhashemi Thanks for the reply and this video. I was searching for a tutorial in internet. This video helped me to learn numerical simulation.

    • @caewitharminhashemi
      @caewitharminhashemi  3 หลายเดือนก่อน

      @@SumandeepSinghRana you're welcome.

  • @shantanuvedpathak-e2w
    @shantanuvedpathak-e2w 3 หลายเดือนก่อน

    hello sir, after clicking on solve it is giving me this error "The Program Controlled Far-field Radiation Surface detection option chosen in the Analysis Settings could not find any surfaces that are a part of Absorption Element/Surface, Impedance/Radiation boundaries or Artificially Matched Layers interface. The post processor will not be able to evaluate Far Field results." how to solve this.

    • @caewitharminhashemi
      @caewitharminhashemi  3 หลายเดือนก่อน

      Hello, this is just a warning and is not important. Don't worry, it won't affect your solution.

  • @nurulsyafina1086
    @nurulsyafina1086 6 หลายเดือนก่อน

    Hi sir, you mention that the other cylinder have rigid boundaries. So, do we need to apply rigid wall on its surfaces?

    • @caewitharminhashemi
      @caewitharminhashemi  6 หลายเดือนก่อน +1

      All boundaries are rigid by default in acoustics system. No need to define rigid boundaries

    • @nurulsyafina1086
      @nurulsyafina1086 6 หลายเดือนก่อน

      Another question sir. Is it possible if i apply surface velocity and radiation boundary at the inlet face? Or we can ignore it?

    • @caewitharminhashemi
      @caewitharminhashemi  6 หลายเดือนก่อน +1

      @@nurulsyafina1086 absorption coefficient is independent of inlet. Port boundary is defined to calculate absorption coefficient and no need to other boundaries

  • @gabrielhernandezrozo848
    @gabrielhernandezrozo848 7 หลายเดือนก่อน

    Hi Armin, how are you? I would like to know if it is possible for you to record a video teaching us how to calculate the tortuosity of a porous medium using COMSOL. Thanks!

  • @PriyankaSuryawanshi-if7du
    @PriyankaSuryawanshi-if7du 6 หลายเดือนก่อน

    Hello sir will you please put a video to see the combined effect of a microperforated plate along with porous absorber.?how to combine two physics together to get net effective absorption coefficient?

    • @caewitharminhashemi
      @caewitharminhashemi  6 หลายเดือนก่อน

      Hello. add a interior perforated plate boundary on the poroacoustics domain. it's not complicated.

    • @PriyankaSuryawanshi-if7du
      @PriyankaSuryawanshi-if7du 6 หลายเดือนก่อน

      @@caewitharminhashemi ok sir i will try. Will you pls share your email ?

    • @PriyankaSuryawanshi-if7du
      @PriyankaSuryawanshi-if7du 6 หลายเดือนก่อน

      @@caewitharminhashemi sir so is it possible to implement in 3 D. as well also do I have to use MAA's equation for that.. only this boundary condition is sufficient?

    • @caewitharminhashemi
      @caewitharminhashemi  6 หลายเดือนก่อน

      @@PriyankaSuryawanshi-if7du I suggest that you solve model with the perforated boundary condition first. 3D model is another scenario and needs another physics in comsol. The Maa equation is not available in Comsol

    • @PriyankaSuryawanshi-if7du
      @PriyankaSuryawanshi-if7du 6 หลายเดือนก่อน

      sir do we have to model this as 2D?