sir agar hame drive me keypad aur potential meter dono se frequency kam ya jyada karna hai to kya karege. dono para meter set karege ek sath ya alaga alag. please bataye.
B1-02 me 1 Karne se push button se start stop hogi H1-05 Me 0 set karo Agr new drive install kar rahe ho to sbse pahle parameter A1-03 me 3330 Karna hai or A1-06 me zero nhi hona chahiye..
Bhai apne jo start stop ka connection batya waise connection kiya hu drive start hota hai par hold nahi hota push karta hu to start ho jata hai par push botton chhod deta hu to stop ho jata jab ki usko hold hona chahiye pls help me
sir frecon fr200 vfd programming speed up down push button seting plz send Sir jo parameter ap n send ky hy wo kam ne kerthy jab tak ref selection na ho
Very nice teaching Sir 👍
Apaka batane ka tarika bahut hi acha hai . thanks sir
Thanks
Looking good 👍👍👍❤
Thanks
Very nice sir..bohut helpful he
Super 👌🙏🙏🚩
Very very interesting, your all video's are very informative & very useful but let me know in detail explain about what is sink/source
Thanks sir ❤
Thanks for watching
Good knowledge...👌👌👌
Thanks
Good job
G5 ki port wiring batao na ac derive yeskawa ka hai
Hi,
How to parameter yaskawa v1000 for 3 motors with the same current
Thanks
Good
Thanks
L1000 Gearless auto door tunning ke bare me bataye
very helpful vedio sir,
sir agar HC-H1 ka loop wire open kar dege to kya hoga.
Stop ho jayega
Hbb ka error aayega
Hello sir .
Kya a j and v series ki program same hai?
F7 Yaskava VFD analog out kw can take instead of speed... If can take which parameter can be set
sir agar hame drive me keypad aur potential meter dono se frequency kam ya jyada karna hai to kya karege. dono para meter set karege ek sath ya alaga alag.
please bataye.
Alag alag set karna hoga
Sir 4 to 20 ma ka reference dcs800 se denfoss ke speed control karana hai
1)4 no ke DIP switch ko on kar do
2) + ko drive ke 60 terminal se or - ko 55 terminal se connect kar do
3) parameter 3-15 me 2 select kar do
@@Electrical-Automation sir reference pe ek video banaeye
how to set up if you want a pressure transducer to run the vfd (on off)?
help please!!
b1-02 I turn on 02, writes Call
what to do ?
the joystick doesn't work
Sir v1000 inverter when I changing frequency busy message coming, what's the problems
Sir denfoss vfd ko other vfd ke reference se kaise wiring kare
Reference kya hai 0 to 10 volt ya 4-20mA
Please explain what is 2 wire mode & 3 wire mode
Thanks
Sirji b1.02me 3 enter Karen se for.Rev.Aur Stop be hogi push Bottom we high ji
B1-02 me 1 Karne se push button se start stop hogi
H1-05 Me 0 set karo
Agr new drive install kar rahe ho to sbse pahle parameter A1-03 me 3330
Karna hai or A1-06 me zero nhi hona chahiye..
Bhai apne jo start stop ka connection batya waise connection kiya hu drive start hota hai par hold nahi hota push karta hu to start ho jata hai par push botton chhod deta hu to stop ho jata jab ki usko hold hona chahiye pls help me
Parameter H1-05=0
@@Electrical-Automation bhi thoda detail me samjha na pls aaj do din se set kar raha hu nahi ho raha hai pls help me
Bhai apna whatapp no de do pls
@@shamsansari1446 Sir Mai aap muje training de sakte ho
@@MDSaleem-iq5iy kis chiz ki tarining chahiye
Konse Perameter se lo/Re button lock hota hai
sir, we did wiring like on pot 1=AC 2=A1 3=+V
Thank you so much sir
Modbus connection kya hota hai??
Local remote keypad se kya hota hai phir
Local remote selection ka button drive ki keypad me hota h
Buenas tardes Me puede enviar diagrama y hojas de programacion de lo mas basico en español grcias
bb base block problem ko kese door kare
Question nahi samjh aaya
Sir अलार्म बन्द नहीं हो रहा था । बार बार बेस ब्लॉक डिसप्ले पर आ रहा था। bb और अलार्म
Kyun sa model hai drive ka
Base block ka parameter active hai H1-01 Se H1-07 ke kisi ek parameter me. Use change karo
V 1000
What is optional card ?
Extra digital input if required
Cómo podría programar para un control con PID con una entrada A2 de un traductor de presión de 4-20mA te lo agradecería mucho?
Nice
Thanks
Sir pls pdf send karie drive ka
sir frecon fr200 vfd programming speed up down push button seting plz send Sir jo parameter ap n send ky hy wo kam ne kerthy jab tak ref selection na ho
Up down push button connect DI5 DI6
AND
parameter
F04.04 =10
F04.05 =11
Sir please or rule batana
Please have a engine that works on your machines that are not interested in your wates but for responding only on the playback of the hands
How to control torque between two ac drive yaskawa v1000
thank u
Hi
J1000 yeskawa VFD on,off push button , potential control parameters send me plz
Plz tell me anybody
Ma mb mc kya hai
Wrwww