how to wire up a 3 phase unit and disconnect

แชร์
ฝัง
  • เผยแพร่เมื่อ 12 ก.ย. 2024
  • How to wire 3 phase unit and disconnect on a roof

ความคิดเห็น • 71

  • @6popgod845
    @6popgod845 9 หลายเดือนก่อน

    Possibly one of the best videos ever. Great explanation you nailed it. “To teach is to learn again”

  • @ledepart.design
    @ledepart.design ปีที่แล้ว +1

    Wonderful clean job!
    Greetings from eastern Arabia

  • @Soldier_4_Christ
    @Soldier_4_Christ 4 ปีที่แล้ว +6

    This dude is an animal he’s over here promoting dewalt while humbly admitting Milwaukee is good as he drinks a body armor and throws it on the ground this dude is a savage.

  • @joedmillermiller
    @joedmillermiller 4 ปีที่แล้ว +3

    I was sitting here eating my sugarless gummy bears. The flavor was a tad off but I thought maybe I was losing my tastebuds because of the 'Rona. Suddenly, I had a massive case of BG's. For you that don't know. Thats the bubble guts. I rushed to the closest restroom to relieve myself, unable to make it in time. With liquid doo-doo oozing out of my pant legs I finished the last 40 yards to the restroom, at a speed that I could qualify for the NFL. As I sat here crying internally in quite shame and pain, I suddenly came across this video. Thank you. Thank you for making me forget that I dont have a change of underwear and am no where close to my house.

  • @jhoney2346
    @jhoney2346 2 ปีที่แล้ว +2

    Good work dude thanks for the refresher course

  • @inquisitive980
    @inquisitive980 8 หลายเดือนก่อน +1

    I always use plastic bushings on connectors.

  • @leegordon8034
    @leegordon8034 3 ปีที่แล้ว +2

    I like your work man keep it up 🖒hope one day I can be among u guys working

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว +2

      Thank you man I appreciate that, if your ever in tn we hire green and train you up so you can turn that hope into a goal and make it happen!

  • @bsahale
    @bsahale 3 ปีที่แล้ว +4

    Love your work.

  • @robertmartin5167
    @robertmartin5167 ปีที่แล้ว

    I like your video every much , it is very informative to me .where the disconnect is install on strut ,do you bolt it to the roof .
    Can you make more video like this

    • @rippleaffect1698
      @rippleaffect1698  ปีที่แล้ว

      It's sitting on roof boots so it doesn't damage the roof membrane.

  • @adriansangerman3491
    @adriansangerman3491 2 ปีที่แล้ว +2

    Is a grounding bushing required?

  • @anthonyesparsen9453
    @anthonyesparsen9453 ปีที่แล้ว +1

    Guys don't cut towards yourself because if you slip you get cut, better to cut away from yourself

  • @AlexMartinez-dc4pe
    @AlexMartinez-dc4pe 3 ปีที่แล้ว +5

    Plastci bushings missing at connectors, everything else good.

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว +1

      Nec. Section 300.4(f) only needs bushings for wire 4 awg and larger but it doesn't hurt to put them on all the time good catch but my wire size is in the parameters to not require one.

    • @WeMe83
      @WeMe83 ปีที่แล้ว

      Must’ve missed the 1” and larger pipe.

  • @joedmillermiller
    @joedmillermiller 4 ปีที่แล้ว +2

    Electricians are always so handsome and manly

  • @mingliao4312
    @mingliao4312 3 ปีที่แล้ว +1

    Cool dude done a excellent job!

  • @tebbink
    @tebbink 3 ปีที่แล้ว +1

    Becarefull Boss...
    👍👍

  • @SuperGurumoorthy
    @SuperGurumoorthy 4 ปีที่แล้ว +1

    Cool video, thanks for sharing

    • @rippleaffect1698
      @rippleaffect1698  4 ปีที่แล้ว

      Hope it was useful and thanks for watching

  • @matthewellis3004
    @matthewellis3004 7 หลายเดือนก่อน

    Nice work

  • @wuukaa9079
    @wuukaa9079 3 ปีที่แล้ว +1

    This is so interresting!

  • @mv8771
    @mv8771 ปีที่แล้ว

    If the source wiring is coming from the panel with a breaker, then the disconnect would be non-fused for a 220v, single phase system for an HVAC unit?

  • @henryhenry271
    @henryhenry271 5 หลายเดือนก่อน

    no torquing?

  • @JoseOPerezRuiz
    @JoseOPerezRuiz 2 ปีที่แล้ว

    Did you have any Problem connecting a 480 WYE Hi to a 208 WYE Lo color code?

  • @Doughboyz412
    @Doughboyz412 2 ปีที่แล้ว

    great video

  • @tonyn7168
    @tonyn7168 3 ปีที่แล้ว +1

    im from Canada and its exactly the same way we do it, except our colours for the 3 phases are different

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว

      Thanks for the comment! Is your voltage the same 277..480

    • @tonyn7168
      @tonyn7168 3 ปีที่แล้ว +1

      Nope, it’s typically 347/600 and 120/208

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว

      So 120 208 is common here but I'm interested on how your working with 347/600 is that considered your industrial type panels for factories and plants?

    • @tonyn7168
      @tonyn7168 3 ปีที่แล้ว +1

      @@rippleaffect1698 yep our warehouses, factories, oil refineries, even some office towers are all 347/600. I have yet to seen 277/480

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว

      So can you explain it a little like from the transformer to the panel you dont have to but I'm curious

  • @nathanbecker2222
    @nathanbecker2222 11 หลายเดือนก่อน

    Shout out to Body Armor! 💯

  • @sylvesterstewart868
    @sylvesterstewart868 3 ปีที่แล้ว +1

    How is your Unislut racking secured to the roof?
    Would love to see the transformer.

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว

      Its built on roof boots..
      Heavy rubber with strut bolted to the top

    • @sylvesterstewart868
      @sylvesterstewart868 3 ปีที่แล้ว +1

      @@rippleaffect1698 Interesting, I really enjoyed watching you wire that AC unit.
      You remind me of a dude I did solar with.

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว

      Thank you

  • @Flipping_Assets
    @Flipping_Assets ปีที่แล้ว

    How do I ground a wire on a 3 phase 3 fuse electrical disconnect box if I'm hooking up a 3 wire welder outlet?

  • @Gamer-Family76
    @Gamer-Family76 3 ปีที่แล้ว

    Hi there I was wondering if you could give me some info How can you take a 3 phase meter Box remove it and replace it with a single phase meter Box

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว

      Need some more info are you replacing a panel from 3 phase to single phase? Or just replacing a meter but keeping the 3 phase panel

  • @nomadismileseeker6611
    @nomadismileseeker6611 3 ปีที่แล้ว

    Could you adapt this to interrupt for a 240v 4 wire plug? Like from a generator?

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว

      Not for this application because it is 480v

  • @ehongrobles9159
    @ehongrobles9159 ปีที่แล้ว +1

    DeWalt baby

  • @errinwright
    @errinwright 11 หลายเดือนก่อน

    Berry Lemonade Bodyarmor

  • @anthonypicozzi4414
    @anthonypicozzi4414 ปีที่แล้ว

    You don't need to pull a neutral ??

    • @rippleaffect1698
      @rippleaffect1698  ปีที่แล้ว

      No sir, it's not required for this air unit.

  • @nicholasaguilar6285
    @nicholasaguilar6285 4 ปีที่แล้ว

    FOUND YOU BOI

  • @robanderson4137
    @robanderson4137 3 ปีที่แล้ว

    I don't understand why there's no neutral white wire? Ya I'm a newb, just tryin to understand 3 phase

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว

      It's a 480v motor that is being powered so it doesn't require a neutral..
      Also if a 277v 480v system did need a neutral it would be grey, white is standard in the u.s. for low voltage systems such as 120v 208v

    • @robanderson4137
      @robanderson4137 3 ปีที่แล้ว +2

      @@rippleaffect1698 Thanks for the info...I work in an office building with three phase 277 and 120 possibly 480...not sure. I'm just working with LED lights and stuff but it's all different from residential.

    • @lisamallery5063
      @lisamallery5063 3 ปีที่แล้ว

      @@robanderson4137 yeah he is the best if you ever need anything or have questions he is the one i would ask great guy.

  • @mylestaylor9877
    @mylestaylor9877 5 หลายเดือนก่อน

    👀👀9:40 ” I’ll stick it in”

  • @nobodydummy12345
    @nobodydummy12345 3 ปีที่แล้ว +2

    Of your using reducing washers you need bonding bushings on your seal tight connections yo!

    • @rippleaffect1698
      @rippleaffect1698  3 ปีที่แล้ว +2

      Hey David thanks for your response,
      You have a great point but in this instance in this location I am code compliant the reducing washers we used were ul listed and we had no concentric rings.
      250.97 EX. 4
      From UL GROUNDING
      Metal reducing washers are considered suitable for grounding for use in circuits over and under 250 V and where installed in accordance with ANSI/NFPA 70, "National Electrical Code." Reducing washers are intended for use with metal enclosures having a minimum thickness of 0.053 in. for non-service conductors only. Reducing washers may be installed in enclosures provided with concentric or eccentric knockouts, only after all of the concentric and eccentric rings have been removed. However, those enclosures containing concentric and eccentric knockouts that have been Listed for bonding purposes may be used with reducing washers without all knockouts being removed.
      But it is a good practice to put them on everything when dealing with 480V especially when outdoors.

    • @magito646gaming9
      @magito646gaming9 2 หลายเดือนก่อน

      But it needs plastic bushing 4awg or larger ?