Yo bro . What is happening is when selfclean/freeze wash/crystal clean ( names given by ac companies to this frost clean feature for idu's evaporator coil cleaning ) is selected by the user initially for some minutes AC's idu(indoor unit) is instructing odu to keep the compressor running to keep flowing the refrigerant liquid through evaporator coils while at the same time idu stops the blower fan to work . Result is stationary surrounding air with moisture starts to condense on top of evaporator coil and ice/frost starts to form in & on top of evaporator coil in idu as idu's blower fan is not working hence not sucking air through ac filter so no air is flowing through evaporator coil hence transfer of the cold temperature to hot air is not happening which happens when ac works in normal cool mode . To defrost those ice/frost from idu's evaporator coil idu after some preset time sends command to odu 2 stop the compressor .which naturally will lead to stopping of refrigerant liquid movement hence loss of cooling to evaporator coil which in turn leads to gradual warming of the evaporator coil due to which ice/frost , which is nearly rock like now , starts to melt & crack inside idu . After that melted water drains After some more frost-defrost cycle the idu's blower fan starts to dry the evaporator coil in idu. Search this cleaning feature on TH-cam where some guys open their idu's air filter to see what's happening and inside it is all white like snow ❄️ LoL It's only available in 5star models that's a shame
Sir ji Mera Haier Ac 1.6ton ka h jabse vgourd ka stablizer lagaya hun tab se input 150 k niche aur output 220 ki niche rehne se Ac bahut acha cooling deta h aur agar input 160 170 se upar aur output 230 ya 240 k upar rehne se cooling dena band kar deta hai So isme Ac ka problem h ya stablizer ka
Pehle Ac ke input voltage check karo kitna hain..agar 230 volt hain to uske andar e rakkho… Jitna recommended voltage hain ac ke utna hi rakkho.. jada voltage se AC main problem aa sakta hain..
Yo bro .
What is happening is when selfclean/freeze wash/crystal clean ( names given by ac companies to this frost clean feature for idu's evaporator coil cleaning ) is selected by the user initially for some minutes AC's idu(indoor unit) is instructing odu to keep the compressor running to keep flowing the refrigerant liquid through evaporator coils while at the same time idu stops the blower fan to work .
Result is stationary surrounding air with moisture starts to condense on top of evaporator coil and ice/frost starts to form in & on top of evaporator coil in idu as idu's blower fan is not working hence not sucking air through ac filter so no air is flowing through evaporator coil hence transfer of the cold temperature to hot air is not happening which happens when ac works in normal cool mode .
To defrost those ice/frost from idu's evaporator coil idu after some preset time sends command to odu 2 stop the compressor .which naturally will lead to stopping of refrigerant liquid movement hence loss of cooling to evaporator coil which in turn leads to gradual warming of the evaporator coil due to which ice/frost , which is nearly rock like now , starts to melt & crack inside idu . After that melted water drains
After some more frost-defrost cycle the idu's blower fan starts to dry the evaporator coil in idu.
Search this cleaning feature on TH-cam where some guys open their idu's air filter to see what's happening and inside it is all white like snow ❄️ LoL
It's only available in 5star models that's a shame
Good information mem ji.age bhi video dalte rahe
Okay
Clean hone ke baad automatically wo apne temperature pe aa jayega...?
Yes…Firse normally start ho jayega…
Self clean per kitni der rakhna h? Or kya us k baad cool ka button press krna h?
15-20 min lagta hain…kuch nehi karna hain..automatic normal mode pe aa jayega
@@dominicrajib thanks
bro self clean feature kitne time mein use krna hai?
@@kartik.bindra 1 month ke dohran
Bhai self cleaning on karne ke bad kya ye clear hone ka bad apne ap band ho jata hai kya ye
@@niteshkr72 no…Clean honey bad Normally on ho jayega
Haier ki HS24HD model kaisa hai pls btaiye
Sir ji Mera Haier Ac 1.6ton ka h jabse vgourd ka stablizer lagaya hun tab se input 150 k niche aur output 220 ki niche rehne se Ac bahut acha cooling deta h aur agar input 160 170 se upar aur output 230 ya 240 k upar rehne se cooling dena band kar deta hai So isme Ac ka problem h ya stablizer ka
Pehle Ac ke input voltage check karo kitna hain..agar 230 volt hain to uske andar e rakkho…
Jitna recommended voltage hain ac ke utna hi rakkho.. jada voltage se AC main problem aa sakta hain..
@@dominicrajib power suply 1PH.230V-50Hz Likha hai Sir Ac mei
Aur stablizer hai 90VAC - 280VAC 50Hz hai
Tmhra steplizer me fault hoga bro. Mai v same ac use kr rha hu bina steplizer k.
Thanks bro...!
Welcome bro
Sir jb AC cooling na kare to self clean ka use kr sakte h bata do
Yes kar sakte hoo
Sir kitni bar karna chahiya month mai
@@SandeepSingh-sf5gh 1 to 2 times
Agar galti say self clean on ho gay hmm nay ac band kar diya kay koi problem hoga
@@gudiyadevi7003 nope
Very good information
@@vishalkashyap1496 Thank you..
Bhaiya self cleaning mode pr jakr ac off kr diya toh koi problem toh nhi hogi
Problem nehi hoga but Cleaning to nehi hoga..firse apko self clean karna parega..
Kitne din baad ye self cleaning karna chahiye ac
Agar apke Environment main jada moisture hain to atleast 7 din main 1 bar to jarur karna hain…nehi to after 20 to 30 days main kar sakte ho…
Kitna time lagega
20-30 min
Ye jo awaj h wo snow ka awaj h snow break hote h uska cracking sound hai
Yes
Normal small aati h,,,,hair 1.5 to kyea karun
Self clean karo
Mera remote to self clean option nehi hai ... Kayse kare
Haier Ke remote hain??
Yes
Utha ke bahar fhenk de😂😂
Bhaiya kitne kitne mahine mai karna hai self clean aur mechanic ko bula kar clean karne ki jurt nhi hai kya
Self clean moisture or germs co clean kar ne keliye use kiya jata hain…
Servicing alag chis hain…
Maine bhi band kr diya tha
No problem
Self cleaning effective nhi he dust coil me chipak jata he.