3 tanks means 3 families. You have not shown individual distribution to 3 families. Some of the family members may use other tanks water which may create problems. Inlet pipes should connect to all 3 tanks in top by controlling valves, so that water will be distributed equally to all three tanks. One extra pipe should connect all 3 tanks just 1.5 inch below inlet pipe of 1st tank.Overflow should be in 3rd tank .This is best method .
1st tank to jaldi bhar jainga aur 2nd ko time lagenga bharne jab Tak 2nd tank wale log ko paani nai aayenga 3 rd ka toh aur bura haal honga is method se
Good presentation, however the in let pipe from pump should have long bend instead of short bend you have used otherwise there will be pressure on pump and pump life will reduce
Supar
3 tanks means 3 families. You have not shown individual distribution to 3 families. Some of the family members may use other tanks water which may create problems. Inlet pipes should connect to all 3 tanks in top by controlling valves, so that water will be distributed equally to all three tanks. One extra pipe should connect all 3 tanks just 1.5 inch below inlet pipe of 1st tank.Overflow should be in 3rd tank .This is best method .
Younayan kaha ha waho bahot lazeme ha
3 different different power supply se 1 samarsebal motor ko kese start and stop kare video banao
Ooo Bhai Union to lagaya hi nhi hai agr Tanky kholni hogi to pipe line katni paregi properly kaam kiya kro Bhai
Meray ko 1000 liters Water Tank 4 inch PVC Chaat kay upper .. Lagah saktey hai?
Hanging ka dalo
1st comment sir
2 tanki 500-500 ltr ki or 1tanki 300 ltr ki kaise teeno ko ek saath connect kare? Plz is par ek video jaroor banayiye plz plz
ha bnauga
Is Tarah Ki fitting Mein Kar chuka hu uski video mein banata hun
overflow kaha per
Sir aapne uniyan nahi Dali hai agar uniyan padi hoti to tank ko alag ker skate the hame tank ko saph karna hai to parshani hogi sir
teen tank ka ky fayeda jb teen flour ke tanki ek shath khali bhi hoge
output alag karo
bharne wala ek shath karo?
Bilkul sahi baat hai
In light Mein yah Nrv Laga ki outlet sabke alag ho jayegi alag Hote s
Bhai Sahab Galat hai ye kaam apka...
Bohat galat hai..
Sahi se Sikho pehle kaam phir karo.
Main bhi Ek Plumber hun...
1st tank to jaldi bhar jainga aur 2nd ko time lagenga bharne jab Tak 2nd tank wale log ko paani nai aayenga 3 rd ka toh aur bura haal honga is method se
3 no tenk sath me hi bharege mene pehle bhi bhut tenk isi tarh fit kiye he koi prablm nhi aayegi pani hmesa leval me bharatahe
तीनो टंकी एक साथ ही भराएगी
@@housewiringplumbing9058 Sath mein nhai bharti
Hy
Dosto dosto Kaam ka baat Kam aur dosto jyada
Good presentation, however the in let pipe from pump should have long bend instead of short bend you have used otherwise there will be pressure on pump and pump life will reduce
Nice video 🤗 bijwe in Hindi Aana chahie
Union please set kijia tab jake sahib hoga
Solvent thik se nahi de raha he ye.
Saba.taka ma pane jaaga
Tank connection me union nhi lagay
Went pole ny diya
New Subscribe Sir
Abe union kon lgayega 😭😁😁
Bahut galat fitting hai esa me union nahi laga hai
Oppo A7 Ram 4 64
Kam Sahi nahi kiye hai
Tank me paani ka over flow rokne ka solution nhi diya
Bhai Diya Hai video mein nahin bataya video Kafi bada ho jata hai isliye