Ap ye tool le lo Is sy bht ache setting hoti ha 160 rupy ma mil jata ha Agar achy wala lo gy to 450 tak ka ha Ye ap ko hardware ki shop sy mil jay ga Online b mil jay ga Feeler gauge Nam ha is tool ga
Allah ap ko aur aap ka ghar walo ko achi sahat ata farmay zia bhai mana jab naya generator liya tha to ma bhut pareshan hua tha chotay chotay kamo par machanic. La ata tha par jab sa apki videos dakhi ha aj aap ki duao sa aj tak machanic ni bolaya thankyou sir
Assalamu alaikum Azhar bhai mashallah se aap ne yaar apna technical hone ka haq Ada kar diya mashallah aur yah bahut achha hum logo ko technical walon ko hai
Bhai jan great video yar hamara generator gas par start nai hota lakin petrol par foran start ho jata hai is ki waja hai aur gas ka pressure b thek hota hai
gas kit ki setting chek karni pary gi gas kit ma prblm ho sakti ha ya ap petrol pe start kr k gas pe change karty ho ?? agar asa karty ho to ap plug ko jalid matlab kuch din bad saaf kr k lagaya karo agar gas pe start karna ha to ap pulg saf kr laga kr try karo gas pe
Asalam o Alikum Zia bhai, meray generator ka self aisay ghomta hai jaisay battery bilkul low ho, phans k ghomta hai, aur battery ki + aur - ki cable b heat up ho jati hai, self k oper b hath nahi lagta wo b heatup ho jata hai. Kia issue ho ga self ka? Main kick sy start krta hon generator, battery bilkul charged hai. Main ny dosray generator pay battery check ki hai.
Asslamo alikum bahi me ny khol k saaf kia grrs b ki hy magr ab wo ulta work karny laga hy Mtlb ÷postive wire ko - negtive py lay or -ko + py to sahi chalta hy
G bhai ap laga sakty ho Wesy ye battery choti ha Jaldi dim ho jay gi Agar generator jaldi start ho jata ha to phr ye theak ha Agar zyada self pr start hota ha tab battery k dim hony k bad self ma power kam hony lg jay ga
W/salam Ap 25 ya 30 amp ki battery lo Wo kafi time nikal de gi Ap bs battery ka pani har 15 sy 25 din ma check kar lena Agar kam ho to us ma pani add kar dena bs
Self ma prbm ho sakti ha Self k andar armature hota ha agar armature heat ki waja sy haf jal jata ha jis sy self ka power km ho jata ha Is ka hal ye he hota ha k self ok open kar k check kia jata ha Zyada acha ye he hota ha k ap armature new he laga do
Bhai ap mujhe b jawab dedain. Off mode pe battery terminal laga rha hn sparking hrhi hai. Aur lagane k bad self start hojata hai. Jub genrtor off krdeta hn tu next day battery he beth jati hai. I checked chargin theek hai. 2nd battery b theek hai. Lekin aisa lag rha hai k koi cheez battery ko pee rhi hai self mei .
ap ki bat sy mje ye lg rha ha k ap k generator ka switch khrab ho gaya ha ya phr koi connection theak sy nhi laga hua ho ga ap agar new switch laga sakty ho to ap new switch laga lo 2nd bat ye b ho sakti ha k battery ma b falt ho sakta ha battery ko ap battery shop pr check karwo pani or battery k cell check ho jay gy
@@ZiaTvgenerator shukria Bhai. Mere generator wale ne bhi yahi kaha hai K switch ka fault lag rha hai. Usse shaq b hua tha. Abb naya swinch dalke dekhainge. Thanks for info.
G g generator ki sab videos upload ho jay to us k bad free hn ga or phr in sab pr video bana kr upload karo ga Switch ki wiring gas kit ki full video banao ga
zia bhai mera 3 kva ka generator hai jaise hi start ho jata hai gas per aur phir thori dair baad tad tad ked ked ki awaazen ati hai is key barey mai kiya ho sakta hai kisi ko dekhaya tu unho ne kaha engine mai se awaz arahi hai bhai iskeye koi hal koi video upload karo
Zia bia.mera generator ka plus wire generator boday say lag nay say sparks nahi karta.baki kabi automatic generator rellay lagaye ha kabi start karta ha kabi nahi.kia vaga ha?
Amjad bhai ap ki bat theak sy samjh nhi paya Ma lead k bary ma bata deta hn Plus lead generator ki body sy touch karny sy spark hota ha Agar spark nhi hota ya achank spark hota ha to hamari leads loss hn gi ya kisi jega sy lead ma cut ya jor etc kamzor ho ga Ya terminal ( battery clip ) loss hn gy Achanak lead k set hony ya helany sy lead ma power aajany sy spark ho jata ha Agar ap is k ilawa koi bat pouch rahay hn to wo mje batao to ap ko reply kr dn ga Thanx for watching my Videos
اسلام وعلیکم بھائی میں نےآپ کے بتائے طریقے کے مطابق آرمیچر پر جو کاربن کی لیئر بن جاتی ہے وہ صاف کر کے چیک کیا لیکن کوئی فرق نہیں پڑا, لہذا میں نے نیا آرمیچر لگا کر برائےراست بیٹری پر چیک کیا تو سیلف نے بہترین کام کیا, لیکن سیلف فٹنگ کرنے کے بعد سوئچ پر انجن کو بہت آہستہ گما رہا ہے, پھر پلس کے تار کو میں نے کپی پر برائےراست لگایاتب بھی انجن آہستہ ہی گھوم رہا ہے, جبکہ میں نے بیٹری بھی نئی لگائی ہے, برائے مہربانی اس مسئلے کا بہتر حل بتائیں . شکریہ
Asslamu alaikum mera generator 2.5 kv loncin ka self kabhe load leta hy jaisy battery down ho aur kabhe normaly generator start hojata hy baaz okaat jab load yanee jaam chalay to 3 ya 4 martba try karny par normal behave karta aur generator start hojata hy aur kick bhe bohat zyada jaam hy main oil time par change karta hoon generator ka ignition switch kharab hogaya tha jis ke waja sy self 1 ghainty tak on raha aur uss ke coil jall gaye thee mainy coil change karde thee 8 9 maheeny sahe chala par abh ye maslay kar raha hy engine seald hy aur 3 hazaar ghainty chal chuka hy
Ap tuning kar lo generator ki Carborter , plug , or tappit ko theak sy saaf karo Ap k generator ki main prblm jo ha wo ha valve ki setting thori out ha Valve ko tappit b bolty hn rocker b bolty hn Ap in rocker ko out kr k petrol sy saaf kr k new setting karo Ap k pass feeler gauge tool ha to us sy valve ki setting perfect hoti ha Agar tool nhi ha to mje batana ma phr setting ap ko WhatsApp sy karwa dn ga
Zia bhai meri problem solve krden please mere generator ko abhi 1 saal hua hai lekin mera generator sirf 8 ya 10 din oil chalata hai, 8 ya 10 din bad generator srf 5 min ya dus min chalta ha aur bund hojata ha phr oil change krdo to sahi chalta ha, maine humesha oil bhi 1 no dala ha Pso ka blaze dalta hn ek bar zic bhi dala ha baqi yahan aur logoun k generator 20 ya 25 din tak aram se chalte hain please jaldi iska solution bata dain 😕
Wesy ye theak ha k 8 sy 10 dil ma oil change kr lena chahye Is sy engine fit or saaf rhta ha Generator ka oil 60 hours sy le kr 80 hours ma chenge krna best hota ha Zyada sy zyada 100 hours sy oper na jay Agar day and night ma 6 hours b generator use ho rha ha to 10 din ma oil change karna parta ha Zyada sy zyada 12 din Ap k generator ki setting theak ha ap isi pr chala sakty ho Phr b agar ap ko theak nhi lagta ha to is ka 1 hal ye ha k ap low oil sensor ki jo lead ha is lead ko disconnect kr do to phr generator off nhi ho ga
Self k pechy sy 1 lead nikal kr aarhe ho gi jo engine k ander sy nikal kr ati ha Is lead ko dhkhny k lye ap ko self k nechy sy dhkhna pary ga to ye lead nazar aajay ga Or is lead ka clr zyada tar yellow hota ha Kuch generator ma chenge ho hota ha clr Ap is lead ko disconnect kr do to phr generator band nhi ho ga Is lead ma 1 joint ho ga ap ne is joint sy lead ka disconnected kr dena ha
Please share your contact number . Meray generator mein problem arahi hai. Jab generator switchoff krty hain tab battery discharge krta hai woh aur kuch hi ghnanto mein battery pori thandi kardyta hai
Armature ko multimeter sy check kia jata ha Or wesy dhkhny sy b pata chal jata ha agar jal gaya ho ga to winding black ho jati ha Ya koi wire jal kr toot jati ha Ye sab dhkhny sy pata chal jata ha Nhi to multimeter sy check kr sakty hn
+92 312 3902109 Ap mje whatsapp pr self ki choti c video bana kar send karo Ma dhkhny k bad ap ko bata sakta hn Ap ne carbon saaf kar k lagay thy ?? Asa b ho sakta ha k ap k self ka rotor jal gaya ho
Ap k generator ki battery theak sy charge nhi ho rhe ho gi Battery dim ho to asa hota ha Agar battery theak ha to phr self ka armature kamzor ho ga Main battery dim ho gi ap battery check karwao
Self kam nhi kar raha ho to main armature khrab hona he waja hoti ha Pr kabi kabi leads ya switch ki khrabi b hoti ha Armature ko out karny k bad armature ki wiring dhkny sy pata chal jata ha k wo jal gay ha Agar theak ho ga to wiring theak ho gi Jis tarhan motor k jal jany sy wiring black ho jati ha isi trhan armature ki wiring b jali hui aram sy nazar aajati ha
Self kam nhi kar raha ho to main armature khrab hona he waja hoti ha Pr kabi kabi leads ya switch ki khrabi b hoti ha Armature ko out karny k bad armature ki wiring dhkny sy pata chal jata ha k wo jal gay ha Agar theak ho ga to wiring theak ho gi Jis tarhan motor k jal jany sy wiring black ho jati ha isi trhan armature ki wiring b jali hui aram sy nazar aajati ha
بھائی جب میں نے جنریٹر کو سیلف دیا تو کُپی ٹک ٹک کی آواز کر رہی تھی لہذا میں نے سیلف کھول کر آرمیچر دیکھا تو اس میں کوئی خاص مسئلہ نظر نہیں آیا مطلب آرمیچر بلکل صاف تھا, مہربانی کرکے اس مسئلے کا حل بتائیں. شکریہ
G asa b hota ha is ki waja hoti ha carbon self k andar 2 carbon lagay huy hn carbon gis kr armature pr 1 Lear c bana deta ha jis sy power armature tak nhi ponch pati ha is waja sy self kam nhi karta ha ap armature ka wo hesa jis pr carbon lagata ha is ko saaf kar lo or carbon ko b saaf kar k lagao or carbon tak aany wali wire b check karna wo b theak ha wire ma b problem ho sakti ha
اَلسَلامُ عَلَيْكُم وَرَحْمَةُ اَللهِ وَبَرَكاتُهُ، ضیا بھاٸ میرا ساڑے 6 کے وی اے کا ھوم ایج کا جرنیٹر نیا لیا تھا ایک سال ھو گیا ۔میی نے نیٸ بیٹری لگاٸ ھے HA 50کی سلف پر اسٹارٹ اور نا ہی سامنے بورڈ پر کوٸ لاٸٹ آتی ھے۔ اگر ڈوری کھنچ کر اسٹارٹ کرو تب اسٹارٹ کرو اسٹارٹ ہو جاتا ھے اور فرنٹ بورڈ پر لاٸٹیں بھی آن ہو جاتی ہیں۔ اسٹاٹر بھی ٹھیک ھے۔ بیٹری بھی چارج کرتاھے۔سلف بھی ٹھیک ھے۔ آپکے بتاۓ طریکوں چیک کر کے دیکھ لیاھے۔بات نہی بنی ۔براۓ مہربانی حل بتاۓ۔ شکریہ۔
Ap valve ki setting karo Exhaust valve ki setting karo Plug ko theak sy saaf kar k lagao Or exhaust valve ko thora sa tight karo IN SHAA ALLAH Set ho jay ga
Ap k self ka rotor garam hony sy kam karna band kar deta ha Ap rotor new laga lo Zyada garam hony ki waja ha self ko had sy zyada der tak self marna Main ye he waja hoti ha Next agar generator jam ha tab b self pr load ata ha Ya self khud jam ho jay tab g garma ho kar jal jata ha
salam bhai ..mere generator me self sirf halka sa spark krta h or batry charge ni kr raha kuch time pehle me ne ignition switch change kiya tha mujhe connection me doubt lag raha he q k jo pehle switch tha us me 5 wire ti or is me 6 fuse wala switch hen dono ya to wiring samjha den ya to fault bata den loncin ka generator h lc-5000 d-a he plz badi mehrbani ho gi...
Switch ap ne khud change kia ha ? Mje lagta ha ap ne jo battery charge karny wali coil ki lead ko thk sy nhi lagay ho ga Ap generator ko start kar k battery ki lead jo( + ) ki lead ha us k cilp ko nikal kar battery sy touch karo or chek karo us ma spark ho raha ha ? Mane 1 video battery pe banai ha us ma mane charge ko chek karny ka bataya ha ap wo video dhkho us tarha chek kar k mje batao phr ma ap ko aagay ka batao ga k kia prbm ho sakti ha
Zia Bhai Bht bht meherbani Apki
Apki waja se mene apna Generator khud Thk Kia poora Engine Khud banaya wall head Ring piston sb khud banaya new Bht Acha chalra Hai Generator Masha Allah kbi kbi Tapet lose hojate hn Abhi mene check Nutt Doosre lagaen hn Thk chalra Hai filhal
Tapet mene andaze se tight kiey they shayd Uska Masla ho mere pass tools ni they jese Ap k pass scale Hai gage wala
Ap ye tool le lo
Is sy bht ache setting hoti ha
160 rupy ma mil jata ha
Agar achy wala lo gy to 450 tak ka ha
Ye ap ko hardware ki shop sy mil jay ga
Online b mil jay ga
Feeler gauge
Nam ha is tool ga
Thank you zia Bhai u r great man
Bhai apki video se bohut help mili
Allah ap ko aur aap ka ghar walo ko achi sahat ata farmay zia bhai mana jab naya generator liya tha to ma bhut pareshan hua tha chotay chotay kamo par machanic. La ata tha par jab sa apki videos dakhi ha aj aap ki duao sa aj tak machanic ni bolaya thankyou sir
آج میں نے تمہاری ساری ویڈیوز دیکھ کر اپنا جنریٹر خود ہی بنا لیا
اللّه کے حکم سے ہاف سلف سٹارٹ بنا ہے
Assalamu alaikum Azhar bhai mashallah se aap ne yaar apna technical hone ka haq Ada kar diya mashallah aur yah bahut achha hum logo ko technical walon ko hai
بہت اعلی ویڈیو اپلوڈ کی ہے۔ ایسی اچھی اچھی ویڈیوز اپلوڈ کرتے رہیۓ۔ شکریہ۔
Thanx
Zia Tv Zia Bhai 2 .5 k governer ki setting out side ki video bana thks.
bht he aala zia bhai
بھا ئی آپ بہت ہی کارآمد ویڈیو بناتے ہیں, آپ کی ویڈیو دیکھ کر انجن کو اسیمبل کرنے میں کافی مدد ملی, شکریہ.
Very informative, nice work. Thank you.
Nice bhi
Boht he achi video
Zia Bhai aid mubark
Kher mubarak
Ap ko b Eid mubarak
Uxtad great yrrr
Jawab Allah Apko Kamyab Kre ameeen
Jazak Allah
Good information thanks
Shandar
Bhai jan great video yar hamara generator gas par start nai hota lakin petrol par foran start ho jata hai is ki waja hai aur gas ka pressure b thek hota hai
gas kit ki setting chek karni pary gi
gas kit ma prblm ho sakti ha
ya ap petrol pe start kr k gas pe change karty ho ??
agar asa karty ho to ap plug ko jalid matlab kuch din bad saaf kr k lagaya karo
agar gas pe start karna ha to ap pulg saf kr laga kr try karo gas pe
Zia Tv yar abhi bas 3 months he howay hein generator leye aur sirf is month mein he ziada generator chala hai aur itny mein kit ko masla ban b gaya
Bhai masla nhi ha
Setting karni parti ha
Mtlab jo generator ko chahye wo generator ko theak sy nhi mil raha ha
Is lye theak kam nhi kar raha ha
Nice sir
Sir G Humara Generator self utha he nh rha battery thek.hai to kya probem hoga 4 kv generator hai aur kitna kharcha hoga
Asalam o Alikum Zia bhai, meray generator ka self aisay ghomta hai jaisay battery bilkul low ho, phans k ghomta hai, aur battery ki + aur - ki cable b heat up ho jati hai, self k oper b hath nahi lagta wo b heatup ho jata hai. Kia issue ho ga self ka? Main kick sy start krta hon generator, battery bilkul charged hai. Main ny dosray generator pay battery check ki hai.
Sir starter KO as a moter use Kar sakty ha kaya
Bhai ap sey request hay ap generator charger replacement ki video banai.
Nice
Zia bhai merepas hondaeu30is he iski self motor kharab hogi he khase melegi ?
Asslamo alikum bahi me ny khol k saaf kia grrs b ki hy magr ab wo ulta work karny laga hy
Mtlb ÷postive wire ko - negtive py lay or -ko + py to sahi chalta hy
Good
Bhai mera 2kva ki mini chinese generator hai kaya mai usme self ki battery 12v 9 ah ki lga sakta hu thora help kare.
G bhai ap laga sakty ho
Wesy ye battery choti ha
Jaldi dim ho jay gi
Agar generator jaldi start ho jata ha to phr ye theak ha
Agar zyada self pr start hota ha tab battery k dim hony k bad self ma power kam hony lg jay ga
Salam bhaijaan self battery achi kitne power wali lenii chaye mere pass pehle 12 volt 7 ampere ki lagi huwi thi lekin 6 month me kharab hojati hai
W/salam
Ap 25 ya 30 amp ki battery lo
Wo kafi time nikal de gi
Ap bs battery ka pani har 15 sy 25 din ma check kar lena
Agar kam ho to us ma pani add kar dena bs
@@ZiaTvgenerator thnx
Or upload karo aese video
Mery full generator pr video upload hn
Zia sahb mere generator ki battery new h lkn self pr start nh ho rha kia wja ho skti h
Self ma prbm ho sakti ha
Self k andar armature hota ha agar armature heat ki waja sy haf jal jata ha jis sy self ka power km ho jata ha
Is ka hal ye he hota ha k self ok open kar k check kia jata ha
Zyada acha ye he hota ha k ap armature new he laga do
Bhai ap mujhe b jawab dedain. Off mode pe battery terminal laga rha hn sparking hrhi hai. Aur lagane k bad self start hojata hai. Jub genrtor off krdeta hn tu next day battery he beth jati hai. I checked chargin theek hai. 2nd battery b theek hai. Lekin aisa lag rha hai k koi cheez battery ko pee rhi hai self mei .
ap ki bat sy mje ye lg rha ha k ap k generator ka switch khrab ho gaya ha
ya phr koi connection theak sy nhi laga hua ho ga
ap agar new switch laga sakty ho to ap new switch laga lo
2nd bat ye b ho sakti ha k battery ma b falt ho sakta ha
battery ko ap battery shop pr check karwo
pani or battery k cell check ho jay gy
@@ZiaTvgenerator shukria Bhai. Mere generator wale ne bhi yahi kaha hai K switch ka fault lag rha hai. Usse shaq b hua tha. Abb naya swinch dalke dekhainge. Thanks for info.
Sir Ye kitny wat ka hy
great ... nice video, can we find armature for 5 KVA generator starter too?
Omar alvi.. ok i will uplaod after ramzan.
zia bhai self,battery,ignation,charging connection ki complete wiring par video banay please..
Self battery charging check karna in pr mane video bana rakhi ha
Mery video ma ap ko mil jay gi
OK thanks you
Zia bhai tora clutch k baray mai sekao
اسلام وعلیکم
بھائی کک تو فری ہے, اور انجن اسٹارٹ بھی کک سے ہی کررہے ہیں
ok theak ha
ap 1 bar self ki jo garariyan hn in ko grees kar lo
ho sakta ha ye jam ho rhe hn
self ki bs ye he prbm hoti hn
splender old self lag sakta hai
G g generator ka har parts mil jata ha
Jo b khrab ho wo nikal kr new laga do to kam ho jay ga
Zia bhai salam
Mera 2.5 generator morning k waqt star hone main prob karta hai aksar patakhe marta hai koi hal bataen.
جنریٹرز میں سیلف فٹ کرنے کی جگہ نظر نہیں آرہی
Plz new videos or banyee zia bhai
G ma try kar rha hn
Zia Bhai, low oil sensor ki wiring karna bhi sikhaen plz. Thanks
G g generator ki sab videos upload ho jay to us k bad free hn ga or phr in sab pr video bana kr upload karo ga
Switch ki wiring gas kit ki full video banao ga
Regards
Hello I know it’s an old video but where do you get the armature from?
Armature generator parts shop sy mil jata ha
where is your old video?
How to take out self starter from generator?
Usama Raza first video ma kuch prbm ho gai thi is lye upload nhi ho pai
upload kr dn ga jaldi
ok
THNX
zia bhai mera 3 kva ka generator hai jaise hi start ho jata hai gas per aur phir thori dair baad tad tad ked ked ki awaazen ati hai is key barey mai kiya ho sakta hai kisi ko dekhaya tu unho ne kaha engine mai se awaz arahi hai bhai iskeye koi hal koi video upload karo
Zia bia.mera generator ka plus wire generator boday say lag nay say sparks nahi karta.baki kabi automatic generator rellay lagaye ha kabi start karta ha kabi nahi.kia vaga ha?
Amjad bhai ap ki bat theak sy samjh nhi paya
Ma lead k bary ma bata deta hn
Plus lead generator ki body sy touch karny sy spark hota ha
Agar spark nhi hota ya achank spark hota ha to hamari leads loss hn gi ya kisi jega sy lead ma cut ya jor etc kamzor ho ga
Ya terminal ( battery clip ) loss hn gy
Achanak lead k set hony ya helany sy lead ma power aajany sy spark ho jata ha
Agar ap is k ilawa koi bat pouch rahay hn to wo mje batao to ap ko reply kr dn ga
Thanx for watching my Videos
what is current require for motor
Sir carpayter gass ki setting kesy hoti hai plz video upload karen
G g last video ha ye upload kr dn us k bad viseo banao ga
My name is Zia
اسلام وعلیکم
بھائی میں نےآپ کے بتائے طریقے کے مطابق آرمیچر پر جو کاربن کی لیئر بن جاتی ہے وہ صاف کر کے چیک کیا لیکن کوئی فرق نہیں پڑا, لہذا میں نے نیا آرمیچر لگا کر برائےراست بیٹری پر چیک کیا تو سیلف نے بہترین کام کیا, لیکن سیلف فٹنگ کرنے کے بعد سوئچ پر انجن کو بہت آہستہ گما رہا ہے, پھر پلس کے تار کو میں نے کپی پر برائےراست لگایاتب بھی انجن آہستہ ہی گھوم رہا ہے, جبکہ میں نے بیٹری بھی نئی لگائی ہے, برائے مہربانی اس مسئلے کا بہتر حل بتائیں . شکریہ
ok ap kick laga kr engine check karo engine jam to nhi ha
agar kick zor lagwa rhe ha to phr ap valve ki setting karna
Asslamu alaikum mera generator 2.5 kv loncin ka self kabhe load leta hy jaisy battery down ho aur kabhe normaly generator start hojata hy baaz okaat jab load yanee jaam chalay to 3 ya 4 martba try karny par normal behave karta aur generator start hojata hy aur kick bhe bohat zyada jaam hy
main oil time par change karta hoon
generator ka ignition switch kharab hogaya tha jis ke waja sy self 1 ghainty tak on raha aur uss ke coil jall gaye thee mainy coil change karde thee 8 9 maheeny sahe chala par abh ye maslay kar raha hy engine seald hy aur 3 hazaar ghainty chal chuka hy
Ap tuning kar lo generator ki
Carborter , plug , or tappit ko theak sy saaf karo
Ap k generator ki main prblm jo ha wo ha valve ki setting thori out ha
Valve ko tappit b bolty hn rocker b bolty hn
Ap in rocker ko out kr k petrol sy saaf kr k new setting karo
Ap k pass feeler gauge tool ha to us sy valve ki setting perfect hoti ha
Agar tool nhi ha to mje batana ma phr setting ap ko WhatsApp sy karwa dn ga
Zia Tv thanks feeler gage hy mery pas aap gap bata dain kitna rakhon gas par chalany k leye
Ok ap 0.15mm pr 2no set kr lo
Roter Bari hi muskil sa bahr ata ha?
Magnet ki waja sy asa hota ha
Sir hamku hona armature
bhai 125 kva genrator ka self altinertor or battery ki wiring b tao
125 kv k generator ka kam mje nhi ata
Zia bhai meri problem solve krden please mere generator ko abhi 1 saal hua hai lekin mera generator sirf 8 ya 10 din oil chalata hai, 8 ya 10 din bad generator srf 5 min ya dus min chalta ha aur bund hojata ha phr oil change krdo to sahi chalta ha, maine humesha oil bhi 1 no dala ha Pso ka blaze dalta hn ek bar zic bhi dala ha baqi yahan aur logoun k generator 20 ya 25 din tak aram se chalte hain please jaldi iska solution bata dain 😕
Wesy ye theak ha k 8 sy 10 dil ma oil change kr lena chahye
Is sy engine fit or saaf rhta ha
Generator ka oil 60 hours sy le kr 80 hours ma chenge krna best hota ha
Zyada sy zyada 100 hours sy oper na jay
Agar day and night ma 6 hours b generator use ho rha ha to 10 din ma oil change karna parta ha
Zyada sy zyada 12 din
Ap k generator ki setting theak ha ap isi pr chala sakty ho
Phr b agar ap ko theak nhi lagta ha to is ka 1 hal ye ha k ap low oil sensor ki jo lead ha is lead ko disconnect kr do to phr generator off nhi ho ga
Zia Tv bhai main chahta hn k atleast 15 days bad oil change karun to ap mujhe bata dengay wo lead kise hoti ha aur kidhar hoti ha ???
Self k pechy sy 1 lead nikal kr aarhe ho gi jo engine k ander sy nikal kr ati ha
Is lead ko dhkhny k lye ap ko self k nechy sy dhkhna pary ga to ye lead nazar aajay ga
Or is lead ka clr zyada tar yellow hota ha
Kuch generator ma chenge ho hota ha clr
Ap is lead ko disconnect kr do to phr generator band nhi ho ga
Is lead ma 1 joint ho ga ap ne is joint sy lead ka disconnected kr dena ha
thank you zia bhai mujhe apka whatsapp no chaiye takay main apko pic send karsakun us se zara asani hojaye gi
2 yellow lead hain generator main us jaga kaun se wali disconnect karni hai main apko pic send kardeta hn kindly whatsapp no day de ap apna.
New motor ka part link m share kardo name aur price amount
Mjhe chye urgent
Please share your contact number . Meray generator mein problem arahi hai. Jab generator switchoff krty hain tab battery discharge krta hai woh aur kuch hi ghnanto mein battery pori thandi kardyta hai
اپ ہیڈ پر اور وال پر ویڈیو بنائی
Armature kase check karte ?
Armature ko multimeter sy check kia jata ha
Or wesy dhkhny sy b pata chal jata ha agar jal gaya ho ga to winding black ho jati ha
Ya koi wire jal kr toot jati ha
Ye sab dhkhny sy pata chal jata ha
Nhi to multimeter sy check kr sakty hn
Hamku armature hona
Battery connect karne par self khat khat awaz karta hai ghumta nahi kya Karun??
Reply soon
+92 312 3902109
Ap mje whatsapp pr self ki choti c video bana kar send karo
Ma dhkhny k bad ap ko bata sakta hn
Ap ne carbon saaf kar k lagay thy ??
Asa b ho sakta ha k ap k self ka rotor jal gaya ho
sir mene ap se gas kit ki setting ka kaha tha
G g bhai video banao ga is pr
Bs time kam milta ha
Ma job karta ha is lye time ki kami ha
Rozi karni parti ha peet k lye
Sir plz app gas per generated chlane wale video zaror up lode ke ja ga
sir jb mai self marta hun generator mai toi ajeeb sa sound ata hai like kharrrrrrrrrrr or genetor b start nai hota ... kindly tell me solution?????
Ap k generator ki battery theak sy charge nhi ho rhe ho gi
Battery dim ho to asa hota ha
Agar battery theak ha to phr self ka armature kamzor ho ga
Main battery dim ho gi ap battery check karwao
Bhai Yeh pata kesay chalay ga armature kharab hai ya ho gaya hai
Self kam nhi kar raha ho to main armature khrab hona he waja hoti ha
Pr kabi kabi leads ya switch ki khrabi b hoti ha
Armature ko out karny k bad armature ki wiring dhkny sy pata chal jata ha k wo jal gay ha
Agar theak ho ga to wiring theak ho gi
Jis tarhan motor k jal jany sy wiring black ho jati ha isi trhan armature ki wiring b jali hui aram sy nazar aajati ha
Self kam nhi kar raha ho to main armature khrab hona he waja hoti ha
Pr kabi kabi leads ya switch ki khrabi b hoti ha
Armature ko out karny k bad armature ki wiring dhkny sy pata chal jata ha k wo jal gay ha
Agar theak ho ga to wiring theak ho gi
Jis tarhan motor k jal jany sy wiring black ho jati ha isi trhan armature ki wiring b jali hui aram sy nazar aajati ha
Zia Tv mai us ko start kar raha ho per ho nahi raha leken awaz bhi kar raha armature mai
Per kick se start le raha hai
Ap ka generator kick pr start ho raha ha self pr nhi ho raha ha ye bol rahy ho ya koi or bat ha ??
Ma theak sy samja nhi ap ki bat
بھائی جب میں نے جنریٹر کو سیلف دیا تو کُپی ٹک ٹک کی آواز کر رہی تھی لہذا میں نے سیلف کھول کر آرمیچر دیکھا تو اس میں کوئی خاص مسئلہ نظر نہیں آیا مطلب آرمیچر بلکل صاف تھا, مہربانی کرکے اس مسئلے کا حل بتائیں. شکریہ
G asa b hota ha
is ki waja hoti ha carbon
self k andar 2 carbon lagay huy hn
carbon gis kr armature pr 1 Lear c bana deta ha jis sy power armature tak nhi ponch pati ha
is waja sy self kam nhi karta ha
ap armature ka wo hesa jis pr carbon lagata ha is ko saaf kar lo
or carbon ko b saaf kar k lagao
or carbon tak aany wali wire b check karna wo b theak ha
wire ma b problem ho sakti ha
اَلسَلامُ عَلَيْكُم وَرَحْمَةُ اَللهِ وَبَرَكاتُهُ، ضیا بھاٸ
میرا ساڑے 6 کے وی اے کا ھوم ایج کا جرنیٹر نیا لیا تھا ایک سال ھو گیا ۔میی نے نیٸ بیٹری لگاٸ ھے HA 50کی سلف پر اسٹارٹ اور نا ہی سامنے بورڈ پر کوٸ لاٸٹ آتی ھے۔ اگر ڈوری کھنچ کر اسٹارٹ کرو تب اسٹارٹ کرو اسٹارٹ ہو جاتا ھے اور فرنٹ بورڈ پر لاٸٹیں بھی آن ہو جاتی ہیں۔ اسٹاٹر بھی ٹھیک ھے۔ بیٹری بھی چارج کرتاھے۔سلف بھی ٹھیک ھے۔ آپکے بتاۓ طریکوں چیک کر کے دیکھ لیاھے۔بات نہی بنی ۔براۓ مہربانی حل بتاۓ۔ شکریہ۔
Waalakumsalam
Ap mje whatsapp pr self ki pics send karo
Ma dhkhta hn us k bad ap ko kuch bata sakta ha
@@ZiaTvgenerator please send me watsap contaic.
sir iske parst ke nam btao
Address plz
۔ اَلسَلامُ عَلَيْكُم وَرَحْمَةُ اَللهِ وَبَرَكاتُهُ۔ضیا بھا ٸ اپنا واٹس ایپ بتا دییں تاکہ آپکو سلف اور اسٹار کی ویڈیو سینڈ کی جا سکے ۔ شکریہ۔
+92 312 3902109
Whatsapp num
Bhai Jan mera generator start nai ho raha pataka Mar raha ha plzzzzzz mujhe bata de Kiya masla ha plzplzplzplZ.
Ap valve ki setting karo
Exhaust valve ki setting karo
Plug ko theak sy saaf kar k lagao
Or exhaust valve ko thora sa tight karo
IN SHAA ALLAH
Set ho jay ga
Thanks Bhai Jan Allah ap ko khus rakhe
Bhai Mera self garam hony k bad start Ni krta Kia problem hoskti h ??
Ap k self ka rotor garam hony sy kam karna band kar deta ha
Ap rotor new laga lo
Zyada garam hony ki waja ha self ko had sy zyada der tak self marna
Main ye he waja hoti ha
Next agar generator jam ha tab b self pr load ata ha
Ya self khud jam ho jay tab g garma ho kar jal jata ha
Zia Tv armature new lgaya hai self Jala wa Ni hai thandy engine pr start krta hai but garam hony k bad Kam krna chor deta h, Generator b new hai
Mtlab k agar engine garam ho to self kam nhi karta
Engine thanda ho to self theak kam kar rha ha ???
Zia Tv jee bilkul
Zia Tv thndi gari foran start hojati hai but garm hny k bad ni,1month phly self banwaya Tha ab wo bol rha hai new lga lo
how to recharge generator battery
Cut out ke bari me btaea
Meri khayal me hamare genretor ka cut out kharab
Genretor strt nehi hora ha ... pleassss
G bhai whats App per imags sand kya ..pleas reply me shukrya
salam bhai ..mere generator me self sirf halka sa spark krta h or batry charge ni kr raha kuch time pehle me ne ignition switch change kiya tha mujhe connection me doubt lag raha he q k jo pehle switch tha us me 5 wire ti or is me 6 fuse wala switch hen dono ya to wiring samjha den ya to fault bata den loncin ka generator h lc-5000 d-a he plz badi mehrbani ho gi...
Switch ap ne khud change kia ha ?
Mje lagta ha ap ne jo battery charge karny wali coil ki lead ko thk sy nhi lagay ho ga
Ap generator ko start kar k battery ki lead jo( + ) ki lead ha us k cilp ko nikal kar battery sy touch karo or chek karo us ma spark ho raha ha ?
Mane 1 video battery pe banai ha us ma mane charge ko chek karny ka bataya ha ap wo video dhkho us tarha chek kar k mje batao phr ma ap ko aagay ka batao ga k kia prbm ho sakti ha
1 wire h earth wali wo chor di Ti fit krna aap tarika bta den video k zariye 6 wire wale switch ka ....mehrbani ho g
Ok ma video banao ga
Pr yar kuch time lg jay ga
Ok ma video banao ga
Pr yar kuch time lg jay ga
Eid k bad banao ga
Ok ma video banao ga
Pr yar kuch time lg jay ga
Eid k bad banao ga