Victron Multiplus Wiring Options Part 1

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ส.ค. 2024

ความคิดเห็น • 162

  • @LambySRI
    @LambySRI 2 ปีที่แล้ว +46

    45 seconds in and you'd answered the biggest question I had!!!! Input is bidirectional!! Thank the lord. You my fella, deserve a pint 🍺

    • @SanderStolk
      @SanderStolk 2 ปีที่แล้ว +3

      Indeed! The reason that I tuned in was this simple question! It get rid of all my schematics that I've drawn.

    • @HobbyFinn2
      @HobbyFinn2 ปีที่แล้ว +1

      I did not recognise that instantly but read the manual and there it was. There was something about passwords and regulations so that one can not just start messing the network.

    • @mw-tg4tf
      @mw-tg4tf ปีที่แล้ว

      Can someone point me to where in the manual is states or explains the input is bidirectional, looking at the wiring schematic it makes sense but for peace of mind would just want to clarify. Great video though!!

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว +1

      @@mw-tg4tf you just need to trust me - it’s bidirectional. It’s been installed 9 months.

    • @DTech101
      @DTech101 ปีที่แล้ว

      @@eliotmansfield lol bi directional had a talk with someone and I said could I feed PV back the AC output and I was told no looked at the schematics and it’s a big relay, AC in its makeup is bidirectional Alternating Current.
      Great mock-up just seeing the easiest way I could add one with PV backup as well

  • @asturias5153
    @asturias5153 หลายเดือนก่อน +2

    been like looking for two weeks and this guy answered them in a couple of minutes, thanks a lot

  • @MH-ie1sg
    @MH-ie1sg 9 หลายเดือนก่อน +1

    Finally someone who can explain it in a way that even I can understand it! Thank you so much!

  • @incognitowarrior
    @incognitowarrior 2 ปีที่แล้ว +7

    Days of searching and you’ve really answered so many questions and explained things so clearly. Thank you!!

    • @incognitowarrior
      @incognitowarrior 2 ปีที่แล้ว

      Now I just need to figure out how to configure the unit in “single legged” mode to stop it feeding back into the grid on grid failure!

    • @michaelstott8847
      @michaelstott8847 2 ปีที่แล้ว

      @@incognitowarrior my understanding was that this is automatic to protect the grid. I may have this wrong of course

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว +3

      @@incognitowarrior The multiplus wont feed back into the grid on failure there's dual contactors inside the unit (in series - so double redundancy) which drops the "output" on grid loss. This is a certified requirement for G98/G99 in the UK and elsewhere.

  • @MarkPotterdjbluemark
    @MarkPotterdjbluemark ปีที่แล้ว

    THIS IS A FABULOUS VIDEO - great work and well explained WELL DONE Eliot - I just wish I could have found this sooner !

  • @HobbyFinn2
    @HobbyFinn2 ปีที่แล้ว

    This was really great. I have an apartment with 3 phases and only light loads. I start with a simple solution, just using multiplus ii as a ups. Just plugging the input to normal wall outlet. What i did not realise was that I need rcd on the output.

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว +1

      the rcd is required in grid failure because the victron becomes it’s own power station

  • @TobotronPrime
    @TobotronPrime ปีที่แล้ว +2

    this video pretty much covered off the last hurdle I was stuck on - a lot of the diagrams online totally skip over the single leg mode and what that means in simple terms
    thank you for this!
    also another person into track cars and ham radio, top man! M7TJF

  • @Brian-ug3cy
    @Brian-ug3cy ปีที่แล้ว +3

    Thanks for the clear explanation, I'm early days for solar etc so in need of good info. Will you please consider a video to explain your whole system with your rational for the choices you made?

  • @rafm8942
    @rafm8942 ปีที่แล้ว

    Good, simple explanation, I just wanted to know where exactly to install the energy meter, thanks.

  • @mapryan
    @mapryan ปีที่แล้ว

    Fantastic video. So simply explained

  • @jimbosun2
    @jimbosun2 4 หลายเดือนก่อน

    Excellent upload. So clear. I wonder if you could do a video of a 10000kva multi plus 2 totally off grid with a generator 15kwh battery and solar panels. How to safely connect and include the consumer unit and how much power you can get.

    • @eliotmansfield
      @eliotmansfield  4 หลายเดือนก่อน +1

      i don’t want to make videos on something i don’t have first hand knowledge of unfortunately

  • @eliotmansfield
    @eliotmansfield  2 ปีที่แล้ว +1

    So as ever with this stuff we are getting into scope creep. As we head into winter I know that 13kw of batteries wont support my loads, so i've ordered another two pylons to take me up to 20kw and i'm adding a second multiplus in parallel which will give me more charging current to get that pack charged in the four hour GO window, this also means each unit is working less hard during charge and discharge and I also get more inverting capacity. The 5000va unit covers most of my daily loads, including a large induction hob - but two big loads would exceed the capacity.

    • @hillebert
      @hillebert ปีที่แล้ว

      Hi Eliot and thank you for your video. Is it possible to only let the grid feed into your installation and not the other way when using the energy meter together with the multiplus? I have a small 6Kw wind turbine that the power company no longer wants connected to their grid because the inverters are outdated regarding the quality of the electricity produced by the inverters. The turbine´s controllerunit is equipped with two 3Kw SMA windyboy inverters with one phase each, so 400V between phases measured. I intend to install two hot water tanks with heating elements in them. The turbine will primarily heat the tanks, but if possible also help feed the air/water heatpump if possible. I need to make som kind of priority controller with a plc or something for that. Do you think the multiplus II GX can balance the loads for that?
      I am thinking of 15 Kw of battery storage for some of the loads on my property. TIA, Palle

  • @tonybond8344
    @tonybond8344 ปีที่แล้ว +1

    Thanks for the excellent video

  • @wazza33racer
    @wazza33racer 3 หลายเดือนก่อน

    Victron inverters (pulling off batteries) have a continual rating and a surge rating. They are not limited to the continual rating. So for example a Multiplus 2 - 48/5000 has a continual and a peak power rating. Might be a good idea to clearly explain what the numbers on the spec sheet actually mean, power assist etc.

  • @9111logic
    @9111logic ปีที่แล้ว

    Excellent description thanks🙏 However, I am still not fully confident about using this in my application which is going to be an "off-grid" annexe with only the potential option of grid-recharging. The complete Victron system is ready for installation, Links Distr. & Shunt, Gerbo & 250/100 chrger. Without knowing the internal design of this inverter, I find it difficult to create my ideal setup. I hope it will all be explained in the Multiplus user manual.

  • @michaelstott8847
    @michaelstott8847 2 ปีที่แล้ว +5

    Thanks Eliot great video the diagrams make the explanation really simple and you have probably answered 100 of my questions in that video.
    I'm on a quest to build my initial setup with what I think will be The Multiplus II 48v 5000
    With a small capacity of Pylontech Batteries initially then growing overtime.
    The house doesn't have big loads at present no car charger (yet) and still Gas Heating (for now) Hot water is a clever mix of immersion fed by excess AC solar PV and divert to combi if not enough etc.
    Will the Multiplus work with 5kwh of battery initially or am going to be needing more to get started?
    Also any thoughts on the Diverted excess PV to immersion using the Solic 200 for this and it's been great just wondering if it's going to then conflict with the Multiplus.
    Thanks again

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว +2

      I’m running 4 x pylon 3000’s (~13kw) which seems to be a good match for the 5000 multiplus which can recharge the pack in 4 hours overnight - that’s the maximum it can do in four hours. I’ve got 3.5kw of solar as well, which seems well matched. I run a hot tub which pulls about 6kwh daytime. Without solar the batteries would be flat by 4pm, with solar they will last all night. Yesterday which was very sunny, did an hour of immersion too and pack was only down to 40% by midnight.
      There’s victron compatible immersion diverter which is on my to do list:
      www.victronenergy.com/blog/2019/06/11/hot-water-on-the-skeleton-coast/

    • @michaelstott8847
      @michaelstott8847 2 ปีที่แล้ว

      @@eliotmansfield Interesting I may have to double up my batteries from day 1. Was thinking of starting small and growing the setup. I guess I should reach out to Victron and see what the minimum they suggest. There doesn't seem to be anything obvious in the documentation.
      Nice work on your setup! I look forward to if you do anymore videos on it! Thanks again

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว +2

      @@michaelstott8847 I would say 3 x USC3000 is the minimum because you should only pull 25A from each pack. Have a read of this: www.victronenergy.com/live/battery_compatibility:pylontech_phantom

    • @michaelstott8847
      @michaelstott8847 2 ปีที่แล้ว

      @@eliotmansfield amazing thanks for that guide that's really helped. I think I'm nearly ready to push the button and order 2x US5000 now.
      If you were adding additional solar PV what factors would you look at to decide if they should be connected via MPPT or via a PV inverter?
      My thinking is anything that is mainly going to charge the batteries is better on a MPPT and anything for current demand is better on an AC inverter. But actually is it better to just use the MPPT and let the victron multiplus do the work inverting anyway. interested to hear your thoughts on this. Thank you

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว +1

      yes thats right.

  • @bm97ppc
    @bm97ppc ปีที่แล้ว

    FYI, I would use the CT option for the Multiplus it reacts to the grid significantly quicker then the energy meter and it is cheaper. The energy meters have to go Modbus > GX device > VE Bus this adds delay and means you pull and push more to the grid then with the CT.

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      Yes I’ve become aware of that option now - my meter is 20 meters away from the multiplus which i think i might get away with.

  • @5rgs17
    @5rgs17 7 หลายเดือนก่อน +1

    Hi Eliot - great video. Helped me no end. I am drawing up my wiring diagram for my Multiplus II at the moment. I am using Visio. I would like to use your Visio drawing as a start point. Would it be possible for me to upload a copy of your one for me to then modify for my needs?

  • @panospapadimitriou3498
    @panospapadimitriou3498 3 หลายเดือนก่อน

    i guess you wont need the meter when mppt only charges the battery but what is the state of earth and neutral in off grid situation .. ? because i saw a parameter inside system and left it as it is... not yet installed .. will work as mobile station but alway s propper earthed when operated . nice video helped a lot..

  • @JohanHouwaard
    @JohanHouwaard 3 หลายเดือนก่อน

    Hi Eliot you are the champ in keeping things simple. I am planning a home batterie and have a three fase grid connection. Is it possible to take one phase and just add a multiplus 2 (with a 10000 Kva 48 battery hooked up to it).

  • @lyn1337
    @lyn1337 7 หลายเดือนก่อน +1

    2:02 would I need a meter still, if my multiplus was the first thing between the main meter and the fuse panel, if the main meter also has a second fuse panel branching off to another part of the house? my goal is not to export. tyvm

    • @eliotmansfield
      @eliotmansfield  7 หลายเดือนก่อน

      all consumption needs to be cross the victron (so it can use its internal energy meter) for it to work correctly. If that’s not the case then you need an external meter.
      You can also fit an external current clamp on the victron as others have suggested , but I have run into a different issue with that which ive not determined the problem yet.(there’s a thread on victron named slow ess response)

  • @mfr58
    @mfr58 ปีที่แล้ว +1

    Thanks for that. Regarding the earth/neutral bonding relay in the Victron, does it bond when it loses grid earth reference or when grid power is not detected?

  • @mutantthegreat7963
    @mutantthegreat7963 2 ปีที่แล้ว +2

    Hi Eliot, thanks it's getting clearer. In the last diagram, "single leg mode", how does the Multiplus connect to the consumer unit without blowing up? Does it detect the phase of the grid and somehow match it? I'm worried about spending all this dough and wiring it like this..
    Cheers

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว +3

      Yes - it synchronises to your grid before actually fully coming online - typically 20 seconds for g98/g99 compliancy in the uk

  • @mfr58
    @mfr58 ปีที่แล้ว +1

    Hi Eliot, when the Multiplus 2 is in UPS mode presumably it isolates the input/output from back feeding the grid, so is in anti-islanding mode? Also I intend using a laptop to programme the unit, do you know if there is a UPS setting on this interface?

    • @rolandashdown4903
      @rolandashdown4903 ปีที่แล้ว

      Would like to know that, too. Hope it doesn;t need full ATS stuff!?

  • @wrandyarmstrong8527
    @wrandyarmstrong8527 ปีที่แล้ว +2

    Hi Eliot, Can the Multiplus II be connected in single leg mode to my consumer unit in my garage on a 20 amp mcb, rather than directly to the main consumer unit in the house. I'lm intending installing the energy meter straight after the utility meter and running it to the Multiplus II in the garage
    The reason for this is that, I want to limit the noise from the inverter in the house.
    Great video, and your DJ'ing aint bad either :)

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว +1

      yes that will work. Just make sure the cable to the garage is thick enough - it may only be 2.5mm which may not be enough depending on distance

    • @wrandyarmstrong8527
      @wrandyarmstrong8527 ปีที่แล้ว

      Thank you so much for your reply 👍

  • @NukeFPV
    @NukeFPV 5 หลายเดือนก่อน

    Thanks for a great video Eliot :) What would happen in a LOM event to the loads on the AC in/out of the MPII.... i.e. the house loads on the left hand side of your diagram ? Would the MPII go into island mode and effecively supply nothing except the essential loads on AC Out 1 ? Or could it be configured with the right grid code to keep supplying those loads on AC in/out ?
    Secondly.... if a backup generator using an ATS was installed between the grid meter and the rest of the house, would it enable the MPII to keep operating normally ? Thanks ;)

    • @eliotmansfield
      @eliotmansfield  5 หลายเดือนก่อน +1

      ac out 1 is the only output that keeps going on lom - so arrange your loads accordingly - see the other two videos

  • @TheRealAnthony_real
    @TheRealAnthony_real 10 หลายเดือนก่อน

    How would this change on a 3 phase setup ? Surely 3 multiplus II cand then handle all your loads .. on output 1 .. or 1 & 2 in an event of grid failure ..

    • @eliotmansfield
      @eliotmansfield  10 หลายเดือนก่อน

      just use three phase consumers afaic - the main thing is to try and draw similar amounts on all three phases. I have a friend with what i call single legged 3ph setup - so doesn’t benefit from the protected output

  • @LambySRI
    @LambySRI 2 ปีที่แล้ว +1

    The part I don't like..... If the 1 leg is RCBO protected, and I use UPS feature via another consumer with a radial, there would be 2x RCBO on one circuit. 🤔 what's your thoughts on this?
    I'm thinking a time delayed 50ma rcd, and the usual 30ma RCBO from ac1 on the circuit its self.

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว

      yes i believe that’s the answer - which ive not implemented yet. (have two standard rcbo’s inline - so could cause nuisance tripping)

  • @QualityStockFootage
    @QualityStockFootage 2 หลายเดือนก่อน

    So the AC-OUT1 loads of "20A" you are calculating from 4000W / 230V = 17.4A.

  • @roversberg
    @roversberg 6 หลายเดือนก่อน

    at the moment i have it installed like the last option (bi-direktional) but my energy meter is placed after the consumers and before the multiplus 2 500..is this still gonna work though..?

    • @eliotmansfield
      @eliotmansfield  6 หลายเดือนก่อน

      no - because you have the loads drawn on your consumer unit that the energy meter can’t “see”. The other option is to use a victron current clamp around your meter tails plugged directly into the victron instead - you also benefit from faster reaction time

  • @MrCarlRobinson
    @MrCarlRobinson 9 หลายเดือนก่อน

    I have the same Victron as you. The mains has a 50A RCBO after the main breaker. Can the AC input to the victron be supplied via this or does it need to be straight off the main breaker? I’ve already rewired the MCB to give two rows, Essential supplies (AC1 out) and Non-Essential supplies (AC 2 out). I’m going to put the AC grid tied solar on the AC in 1500w. Thanks for the helpful video. 👍

    • @eliotmansfield
      @eliotmansfield  9 หลายเดือนก่อน

      depends if you have an upstream energy meter. if not, all your loads need to be downstream of the victron on ac1/2 as required not exceeding 50a total. If you do have an upstream energy meter (such as et112) then you don’t need ac2 out, because those loads can live upstream of the victron which will still benefit from the ess feature

    • @MrCarlRobinson
      @MrCarlRobinson 9 หลายเดือนก่อน

      @@eliotmansfield I dont have an energy meter. I watched your second video and I think I’ll need to change the AC in breaker for the type B and maybe replace the service breakers with individual RCBOs like you have. Thanks for the quick reply.

  • @amacmedia3221
    @amacmedia3221 ปีที่แล้ว

    If this was in a camper van setup, and I was using the 12/2000 80 multiplus, what size of 3 core cable would be needed to run the m+ input to the hookup and then the m+ output to the consumer unit, 16mm2?

  • @bobsmith9051
    @bobsmith9051 ปีที่แล้ว

    Can I ask if I was to use a multiplus 2 in what you call single legged does it gave to come from / to the consumer like your explanation or can it just be conected via henley block so I'm visualising parallel.

  • @metroelectrical3215
    @metroelectrical3215 ปีที่แล้ว +2

    Amazing information. Currently in the process of installing a few of these systems. But trying to find the correct information is like pulling teeth.
    Is the unit bidirectional at default or would it need to be configured to work that way?

  • @5minwatchreviews
    @5minwatchreviews 2 ปีที่แล้ว +1

    This is really useful.
    For a Van conversion, would you recommend going straight from AC inlet to the Multiplus with a inline breaker in place, then from the Multiplus to the CU?

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว

      Something like that. My video is more around energy storage systems (ess) on domestic properties

    • @5minwatchreviews
      @5minwatchreviews 2 ปีที่แล้ว

      @@eliotmansfield Thank you, looking to accumulate as much info as I can

    • @HobbyFinn2
      @HobbyFinn2 ปีที่แล้ว

      A lot of van + victron videos on TH-cam. 👍

  • @EddieGittins
    @EddieGittins ปีที่แล้ว

    thanks for this video. i’ve already learnt so much from watching it. yet i still have one question. in the single leg mode, the bi directional gds in and out from a spar in the consumer unit. it can supply approximately 20Amp and would use this first, then if need can take extra power from the grid. How is this workload managed. i can’t help but think it’s 2 separate supplies to the consumer unit which isn’t capable of prioritising which input to use first. ? i ask because if i spend lots of money on batteries i wanna make sure i use them/it first.

  • @andrewspicer3493
    @andrewspicer3493 ปีที่แล้ว

    Great video, please could you advise what diagram best fits a multiplus 2 and pylon battery system ac coupled to an existing 2kw array and sunnyboy inverter on a feed in tariff?

  • @timcx
    @timcx ปีที่แล้ว

    Excellent and very helpful video thanks for posting it. I would like to convert my system to Victron ESS but I have an existing Growatt hybrid inverter with 4.5kw of pv and 17kwh of pylontech. I have a victron Multiplus II and an additional Seplos Mason battery but I am not sure how best to set them up preferably using ESS if that is possible. Any thought?

  • @rjsmith26
    @rjsmith26 ปีที่แล้ว

    Brilliant video -very helpful. Do you happen to know - if you have a solar install using a FIT meter which you do not wish to disturb, can The multi II if you use another ET112 on the 230v output from the solar panel invertor - after the FIT meter - can This be used inteligentally to ensure all the solar sourced power (thats now 230v from the solar invertor) to use to charge your batteries or be used for daytime demand? Hope this question makes sense. Thanks again

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว +2

      Not sure I’m afraid - my solar is DC connected directly to the battery bus bar using a victron mppt charge controller. I consume everything I produce.

  • @stephenharrisson9442
    @stephenharrisson9442 2 ปีที่แล้ว +1

    Excellent video thanks Eliot, just what I needed. I wonder could your answer a question for me. I've seen some where that you can connect a pv system to the protected side of the multiple which would be great for long grid failures. Under normal circumstances is that pv input available to the rest of the system? Is that protected circuit input also bidirectional through the multiplus?
    Many thanks Steve

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว

      I suspect yes - but don’t know for sure. I went for DC connected PV - seemed less hassle and it’s more efficient.

    • @stephenharrisson9442
      @stephenharrisson9442 2 ปีที่แล้ว +1

      Thanks for that Eliot. Yeah you would imagine it must be really. Both my of systems are already grid connected so that would be great for me 👍

    • @L81ker
      @L81ker 2 ปีที่แล้ว

      @@stephenharrisson9442 I'm looking at the same issue. I think the issue to be considered with putting PV only on ACout1 is that the PV current is then also passing through the inverter. When batteries are full, that PV output is then fed to the grid through ACin, and any critical loads on ACout2. In the event of grid failure, the Victron MP2 creates a local grid so the PV inverter still runs, and the MP2 can be set to increase frequency to control that PV inverter as long as the PV inverter supports it (change the PV inverter if not). The PV inverter output should come PV inverter - AC isolator - Generation meter - MCB breaker - MP2 ACout1 and gets to the grid via MP2 ACin - Consumer board RCD - Meter - Grid.
      ​ @Eliot Mansfield ,what drawing software is that? - really useful video, thanks.

    • @stephenharrisson9442
      @stephenharrisson9442 ปีที่แล้ว

      @@L81ker hi Clive, I have one solar grid tied inverter connected to the meter tails of my main consumer unit - after an et 112 meter . My question is do I need to change any settings within the multiplus 2 if I feed another grid tied solar inverter into the ups side - ac output 1

  • @MrStraightdart
    @MrStraightdart 2 ปีที่แล้ว

    My understanding was you can connect a clamp from the Multiplus to the incoming just after the meter and before any loads so the unit can monitor the supply ? Or is that with the GX model ?

  • @simontredwell991
    @simontredwell991 2 ปีที่แล้ว

    Can you show us very simply where the et112 usb is connected to an easy Solar and also the three wires that go to the et112 for single phase grid power meter use

  • @ant8241
    @ant8241 ปีที่แล้ว

    Thank you so much for this extremely helpful info.
    Im in the process of purchasing a Multiplus 2 and a 48v 4.8Kwh battery unit purely to support vital kit like the combi boiler, home alarm, CCTV, security lights, modem and maybe the freezer on a UPS back up basis.
    I have a few questions additional to your brilliant advice, and would like to drop you a line for some more info if ok with you....(not sure how to do that as a direct message or mail).
    Thanks again.

  • @daviddorsey8754
    @daviddorsey8754 ปีที่แล้ว

    I have MultiplusII 12v 3000[120 50] 120v. How do you access bidirectional function on AC input( 3 write)

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      Assuming you are using it as an energy storage system (ess) - there’s nothing further to do - it will push against the grid supply to balance out. A 12v system sounds like it might be off-grid rv/boat?

    • @daviddorsey8754
      @daviddorsey8754 ปีที่แล้ว

      @@eliotmansfield Correct.

    • @daviddorsey8754
      @daviddorsey8754 ปีที่แล้ว

      Thanks.

  • @chriswykes2319
    @chriswykes2319 ปีที่แล้ว

    Great video Eliot thank you.quick question. When the inverter is taking power from the batteries and powering the house what happens if the draw is higher than the inverter can give i.e over 3kw?? Does it then pull the extra power from the grid to power the load or would the inverter switch off ?

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว +1

      if the grid is present then the inverter works up to its maximum and pulls the balance from the grid.
      If there’s no grid - then I assume it shuts down - because that’s really all it can do, not sure if it self recovers - i’ve not tried it to be fair

  • @rikdehaas6398
    @rikdehaas6398 ปีที่แล้ว

    Hello Eliot, thanks for this nice video. May I ask what software you use for these drawings? Ciao, Rik

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      Visio - the actual icons are just cuts of the pictures. Victron wont release the icons for visio

  • @MrRichhole
    @MrRichhole ปีที่แล้ว

    Hi, I am planning a single leg mode ESS but grid connection point is 30m from MP. Will ET112 work OK over that distance? Also, could I just use ct clamp which would be simpler to install. Thanks

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      The ET112 uses modbus (rs485) which is a fairly robust serial protocol which is good for hundreds of meters in theory. Although not officially supported, it is possible to extend the connection. Mine is at least 20 meters away extended over genuine cat6 cable (not crappy cheap ebay copper coated aluminium CCA ‘cat’ cable which is fake rubbish - i’ve done a video about it). A friend had extended his rs485 connection via ethernet extenders and it’s also possible to get ethernet versions of the energy meters. You do need to enable the terminator resistor for it to work, look in the pamphlet - it shows how to enable it

  • @nannygrandpaandbertie1357
    @nannygrandpaandbertie1357 ปีที่แล้ว

    Thanks for a great video it’s answered questions I had. You fitted a Zappi? Do you have a circuit diagram for that install?
    Are you a UK distribution for Victron?
    Thanks John

  • @rolandashdown4903
    @rolandashdown4903 ปีที่แล้ว

    Great video Elliot. Can I ask about the scenario of connecting AC-IN to existing CU (including the ET122 up front) and critical loads connected to AC OUT-1. In the event of grid failure, would one need to require ATS circuits included (any discharge to the grid from batteries and/or PV)? I'm in the UK, by the way. And what RCBO rating would you suggest for the AC-IN on the Normal Load CU (40A?) and AC OUT-1 in the Critical Load CU (20A/32A)? Thanks again for the video - like everyone else said below, has answered a gazillion and one questions in 10mins. But now posing a gazillion more! :)

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว +2

      I feed my (two) multiplus 5000 with 2.5mm2 cable protected by a 20A mcb - which is close to the limit of that breaker/cable size. You might ask why not 4mm2 and a 32A Breaker, well it's because I have two 5000's in parallel and Victron state not to over-specify the AC feed wiring. Critical loads are protected by a 20A breaker. Things get complicated, because you should be using type "B" RCD/RCBO's which provide the best protection against induced DC fault currents over AC (old school type "AC" RCD's wont trip if there's a DC current overlaid onto the AC - there's a number of video's about this issue and i didn't mention it in this video). Type A's should be used everywhere as minimum in the 18th regs.

  • @beanso4865
    @beanso4865 ปีที่แล้ว

    Great video - keep 'em coming!
    One question - in the simplest mode, are you saying that a supply from a 16 amp mcb in the main consumer unit (cu) could be used to enable the battery storage? Wouldn't this potentially hook through to the other loads on the cu bus in the house above 16amp if they were close by and trip the mcb? It just seems too easy!

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว +1

      5000va unit needs a 20A mcb. The unit cannot produce more than 5000va (about 4.4kw) so regardless of the house draw it wont exceed that - if you total house draw exceeds that then it takes the balance from the grid.

    • @beanso4865
      @beanso4865 ปีที่แล้ว

      @@eliotmansfield Self-limiting - get it thanks.

  • @joechurch5578
    @joechurch5578 2 ปีที่แล้ว

    Can I just use a CT clamp rather than a hard wired ET112. Will make installation easier. Not bothered about essential loads vs non essential

  • @lukemaxwell3954
    @lukemaxwell3954 2 ปีที่แล้ว

    Great explanation. Question, if I have an existing Solar 3.9kw system could I replace my inverter with the Victron too?

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว +2

      The Multiplus is just the inverter, you can add a blue solar mppt charge controller which does dc to dc direct charging of your battery

  • @user-dr2pg8fk2i
    @user-dr2pg8fk2i ปีที่แล้ว

    Is this diagram made using Microsoft Visio?

  • @leapnlarry
    @leapnlarry ปีที่แล้ว

    Hey Elliot, what program are you using for your diagram? Larry

  • @DreadCentre
    @DreadCentre ปีที่แล้ว

    Does multiplus grid tie? It doesn't seem to have a CT clamp or a CT clamp connector

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      Watch the video again. The victron has an internal one - but if all the energy doesn't cross the Victron (what i referred to as single legged) then you need an et112 as shown in the presentation.

  • @WiSeNhEiMeR-1369
    @WiSeNhEiMeR-1369 ปีที่แล้ว

    thanks
    coop
    ...

  • @MrRichhole
    @MrRichhole ปีที่แล้ว

    Great video, thanks. I have a question about the 50A pass-through limit. In the Victon manual for the MP-II 5000 it says that it is 100A. Below is an extract from the manual for the 48 | 5000 | 70 - 100 | 230/240V, page 11. I'd be grateful if you can help clarify:
    AC-out-1 (see appendix A)
    The AC output cable can be connected directly to the terminal block "AC-out". Maximum torque: 6 Nm.
    With its PowerAssist feature the MultiPlus can add up to 5kVA (that is 5000 / 230 = 22A) to the output during periods of peak power
    requirement. Together with a maximum input current of 100A this means that the output can supply up to 100 + 22 = 122A.
    An earth leakage circuit breaker and a fuse or circuit breaker rated to support the expected load must be included in series
    with the output, and cable cross-section must be sized accordingly. The maximum rating of the fuse or circuit breaker is 122A

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      Multiplus II 48/5000/240v. There's a transfer relay (well two in series for safety) that are rated to 50A only. So either output will support a combined load up to 50A only. Output 1 is the protected loads output, which will support up to 5000Va (which is actually about 4.4kw - VA is NOT kw) when the grid is lost (or 50a when it's present). Output 2 drops if the grid drops. Not sure where you are seeing 100a - the specs are here: www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN.pdf
      edit - the 8000 upwards models support 100A changeover.

    • @davidsteele3037
      @davidsteele3037 ปีที่แล้ว

      The MultiPlus II 48/5000/70-50 has a maximum feed through current of 50A. the 48/800/110-100 has a maximum feed through current of 100A. I wonder if you have a MultiPlus and not a MultiPlus II?

    • @MrRichhole
      @MrRichhole ปีที่แล้ว

      @@davidsteele3037 Well spotted! Yes, I was looking at the MP manual. The MP-II manual does say 50A. Thanks for helping straigten this out for me

  • @SanderStolk
    @SanderStolk ปีที่แล้ว

    Is it also true that you can use single legged mode to connect a PV Inverter onto AC-out2 or Ac-out1? I heard / understood that this is possible but in case of an power outtage the PV inverter has to switch off when the batteries are full during the outage otherwise it will damage the Multiplus.

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว +1

      Not exactly sure so would rather not comment. But if you have on ac1 (protected) the PV will continue to work because it doesn’t know the grid has been lost and the contactors inside the multiplus maintains grid isolation and compliance.

    • @SanderStolk
      @SanderStolk ปีที่แล้ว

      @@eliotmansfield exactly! So you can script or program the inverter to shutdown or DRM the PV inverter by closing a contact. That way you can still charge the batteries.

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว +1

      @@SanderStolk Probably. I went for DC connected solar panels - nice and simple

    • @SanderStolk
      @SanderStolk ปีที่แล้ว

      @@eliotmansfield True! Less loss from DC to AC and back. A MPTT from Victron is a better solution.

  • @STRUTZKOFF
    @STRUTZKOFF ปีที่แล้ว

    Ac out 2 is programable

  • @miguelv431
    @miguelv431 2 ปีที่แล้ว

    It is very disappointed to know that you can only pull 20ah from This multi plus when you are using the ups mode I wonder if can I pull at least 50 ah from a Quattro when connecting to the battery?

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว

      It’s all down to the size of the inverter. A 5000va inverter can only deliver about 20 amps AC.

  • @stevefowler7210
    @stevefowler7210 ปีที่แล้ว

    Hi Eliot Fantastic video.
    I want to use my inverter in what you call single leg mode.
    Just a question.
    How does it monitor for grid failure?

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      No power enters the unit - so it powers down. In single leg mode you only use the input(output) and you must have an et112 energy monitor. You don’t get any off-grid/grid failure support - it only works when the grid is present

    • @stevefowler7210
      @stevefowler7210 ปีที่แล้ว

      Thank you.
      I want to supply mine from a Henley block taken before the consumer unit however after the ET112. Hopfully there’s no use with this.

    • @stevefowler7210
      @stevefowler7210 ปีที่แล้ว

      Of course into a small consumer unit with a rcd and mcb.

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      @@stevefowler7210 why not fit a 20a mcb spur from consumer unit and run it from there?

    • @stevefowler7210
      @stevefowler7210 ปีที่แล้ว

      Few reasons.
      One I have messed up after watching your video it’s clear mine has not been wired correctly and I have now turned it off!
      I had ac in fed from garage consumer unit and then the AC out feeding it back to its own comsumer unit protected then back into the Henley block.
      I found your video after seeing some other comments that if mains shut off my inverter wouldn’t and would power the grid.
      Now I am in a position of how to put it right. I am thinking do away with the feed from the garage and use what was the power out to become the bidirectional supply feed as you mentioned.
      Seems very wrong that this is not spoke about at all in the victron manual or wiring unlimited book.

  • @hunter7181
    @hunter7181 2 ปีที่แล้ว

    Is this using the ESS system and connected to L1 (time 5:30 and 9:40 in video) or not?

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว

      Yes I’m using it in ESS mode

    • @hunter7181
      @hunter7181 2 ปีที่แล้ว

      @@eliotmansfield
      Thanks!

    • @hunter7181
      @hunter7181 2 ปีที่แล้ว

      @@eliotmansfield
      In (5:40 in video) is the L1 powerd by ess and the battery?, and will it work if you have a 3 fase 16 amp cee in the main consumer unit for car charging that the multiplus just power L1?
      I forgot to mention I don't wont to feed any to the grid.

    • @eliotmansfield
      @eliotmansfield  2 ปีที่แล้ว +1

      @@hunter7181 If you have three phase electrics you need three multiplus units (or two units if you are split phase like the US has)

  • @davidpattinson5091
    @davidpattinson5091 ปีที่แล้ว

    I've bought a Multi II 5000/48 with Cerbo GX and Lifepo4 battery pack. Will apply for G99 as in the UK. But looking for an electrician (part P qualified I think) who can install this. Anyone in the UK South East (Berkshire) been through this and have a recommendation? Ideally want someone who has knowledge of the Victron stuff. Cheers

    • @TobotronPrime
      @TobotronPrime ปีที่แล้ว

      you’re going to struggle to find anyone that will touch it
      however it’s not too hard to DIY
      have you got panels up etc?

    • @davidpattinson5091
      @davidpattinson5091 ปีที่แล้ว

      @@TobotronPrime got panels from my original pv system. Not certain it's worth more with this set up as I'm looking to charge the battery up on a cheap electric tariff. This is really only to add an AC coupled battery into my setup

    • @TobotronPrime
      @TobotronPrime ปีที่แล้ว

      @@davidpattinson5091 ahh gotcha I thought you were starting from scratch
      I’ve done mine (6 panels on garage roof) and 4.8kwh battery Victron system myself
      Just got a local spark to install the consumer unit meter and wire the inverter into the garage circuit (which is also connected to the consumer unit)
      Once I get it working I’ll post a link to details here, if that helps…
      I’m self taught, no experience of doing anything like this before, just learnt from YT and applying some basic DIY skills; also from YT lol

  • @masterswish3355
    @masterswish3355 ปีที่แล้ว

    Last method doesn't work with feed-in disabled in ESS remember my guys! :D

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      can you explain more

    • @masterswish3355
      @masterswish3355 ปีที่แล้ว +1

      @@eliotmansfield With my system set up for ESS, i have disabled Grid feed-in and have no meter installed. This stops any power flow towards the grid at all times however the multi's and quattro both follow regions regulations and disconnect Grid when power fails.
      Wouldn't this stop the last example working in this case? I could be wrong though, don't hold me too it. :D

    • @TobotronPrime
      @TobotronPrime ปีที่แล้ว

      @@masterswish3355 if you're referring to the last method as the "single legged mode" without a meter install at the distribution box talking back to the victron inverter, then pretty sure you will be feeding into the grid regardless of grid feed-in or not being set on the victron inverter

    • @masterswish3355
      @masterswish3355 ปีที่แล้ว

      @@TobotronPrime Feed-in disables feeding to the grid, it's an option mainly for places like SA where grid feed-in is disallowed in it's entirety. so no power feeds back via AC-in 1 or AC-in 2.

    • @TobotronPrime
      @TobotronPrime ปีที่แล้ว

      @@masterswish3355 I’m doing the same with mine in the UK (we have the same rule if you install your own equipment)
      But I’m pretty sure you still need either a meter feeding information back if you’re trying to achieve that in single leg mode.
      If your inverter is upstream of everything and AC in runs into it before anything else on the house circuit then probably yes grid feed in setting will work.
      It’s a shame Victron don’t make this sort of thing crystal clear, they skip over the details in almost all their documentation.

  • @MartinVanselow
    @MartinVanselow ปีที่แล้ว

    I tried to get in contact with you concerning a P6066. Any e-mail address?

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      my details are on my channel page

    • @MartinVanselow
      @MartinVanselow ปีที่แล้ว

      @@eliotmansfield Sorry, but I cannot find an e-mail address.

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      @@MartinVanselow I got your email, but my reply bounced. But I dont know anything about P6066’s

  • @StartledPancake
    @StartledPancake ปีที่แล้ว

    Thank you, the documentation from Victron is very unclear for what is a complex product. In the end, you are paying 1500 euros for a 960w inverter (48v, 20 amps) which is just awful value for money.

    • @eliotmansfield
      @eliotmansfield  ปีที่แล้ว

      the multiplus 5000 is a 5000 va, which is close to 20amps at 240v. It will draw around 100A from a 48v battery to achieve that.

    • @StartledPancake
      @StartledPancake ปีที่แล้ว

      @@eliotmansfield ​ @Eliot Mansfield Thank you Elliot for the correction and the excellent videos. Im looking into creating an off grid system with grid forming, using GTI inverters and the multiplus, so have placed the focus too much on the battery amps instead of AC:).
      Our house currently has around 20a connection from the grid, and since we have both electric water heating and an electric car, it can be sufficient. A bunch of smart plugs, plus a large a hot water tank and heavy old french furniture which make for the cheapest thermal batteries outside of filling your living room with rocks. It's also far more comfortable to sit on.