KONGSBERG Simulator I Synchronizing of Generator

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ธ.ค. 2024

ความคิดเห็น • 20

  • @zarpfudeyenski5376
    @zarpfudeyenski5376 2 ปีที่แล้ว

    Maayos ang tutorial. Clear at Madaling makuha. Thank you sir

  • @JicoSUy
    @JicoSUy 3 ปีที่แล้ว

    MARAMING SALAMAT PO SIR.
    GANDA NG PAG EXPLAIN MO PO
    MISAMIS INSTITUTE OF TECHNOLOGY UNDER CAPT. RENE MAGLASANG OZAMIZ CITY 7200 MINDANAO PHILIPPINES!

  • @jadealquisola3283
    @jadealquisola3283 2 ปีที่แล้ว

    Salamat sa tutorial madali makuha at maintindihan

  • @yakitaki26
    @yakitaki26 3 ปีที่แล้ว

    Grabe naman tong barkong to. Automatic mag rerun yung generator 2 at reconnect kapag kailangan. High tech

  • @dhomzbon6979
    @dhomzbon6979 4 ปีที่แล้ว +1

    salamat sa video sir .very informative

  • @jadealquisola3283
    @jadealquisola3283 2 ปีที่แล้ว

    Sana po sir is M/E nanaman

  • @raphaelserviano198
    @raphaelserviano198 4 ปีที่แล้ว

    engine preparation naman sir! thank you dito

  • @spanasia317
    @spanasia317 3 ปีที่แล้ว

    paano po e reset ang connected low load in auxiliary generator sa kongsberg?

  • @rbeligano2668
    @rbeligano2668 ปีที่แล้ว

    Sir pano po mag create or mag download ng initial condition o mga scenario po sana mapansin🙏🙏😊😊😊😊

  • @paulkevin4407
    @paulkevin4407 2 ปีที่แล้ว

    Wala ka na operator ah boss. Ok yan

  • @jamesjames3760
    @jamesjames3760 4 ปีที่แล้ว +1

    Thanks po. Auto synchronising naman po kung pwede. Salamat po. God Bless

    • @kongsbergsimulatorphilippi611
      @kongsbergsimulatorphilippi611  4 ปีที่แล้ว

      Sa auto synchronizing, gamitin mo lang ang conn sa diagram 70. Pero dapat nakailaw ang ready kapag napindot mo ang DG2.

  • @soundcompathy7042
    @soundcompathy7042 4 ปีที่แล้ว +1

    More vids po sir pls. Godbless po

  • @tedjairusdegamo6448
    @tedjairusdegamo6448 2 ปีที่แล้ว

    tanong ko lang sir. paano po ba pataasan ang voltage ng diesel engine 2? yung sa akin V 347.44 ang starting voltage ng DG2 ko sir kaya ayaw mag ready ang semi auto synch.

    • @kongsbergsimulatorphilippi611
      @kongsbergsimulatorphilippi611  2 ปีที่แล้ว

      Punta ka sa MD70, hanapin mo ang governor RAISE at LOWER, adjust mo ang frequency ng Gen 2 para maging slightly higher kumpara sa Gen 1.

  • @PAULJOHNGBRIOL
    @PAULJOHNGBRIOL 4 ปีที่แล้ว

    Good job sir. 👍

  • @escartinjegyb.7462
    @escartinjegyb.7462 3 ปีที่แล้ว

    Good day po sir! Ask ko lang po bakit po ayaw mag automatic connect po yung DG2 pagka po nag ooperate na po ng Boiler namamatay po kasi then kelangan po ulit isynchonize para gumana.. Ano po pwedeng gawin.. thanks po

    • @kongsbergsimulatorphilippi611
      @kongsbergsimulatorphilippi611  2 ปีที่แล้ว

      Kapag na Auto mo na ang DG2, kusang madisconnect yan kung mababa ang load na kayang supplayan ng DG1. Mamatay makina nya pero mag Auto start din sya at auto connect kapag tumaas ang load na di na kaya ng DG1.

  • @happykitchen8106
    @happykitchen8106 3 ปีที่แล้ว

    Daddy si yona to

  • @tedjairusdegamo6448
    @tedjairusdegamo6448 2 ปีที่แล้ว

    very informative idol. Salamat ng marami