R-404a gas charging || Cone Ice cream machine gas charging -32 ⁰C

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ส.ค. 2024
  • #icecream
    #r404a
    #icecreammaker
    R-404a gas charging || Cone Ice cream machine gas charging -32 ⁰C
    Hello Dear friends I hope you all will be fine and very well. Today in this video I have to tell you about the,
    R-404a Gas charging || Ice Cream Storage machine.
    Cone Ice cream machine || R-404a gas charging
    How to charge r-404a refrigerant in ice cream storage machine.
    ice cream storage machine,
    ice cream machine,
    machine for ice cream,
    ice cream,
    how to gas charge,
    how to gas charge R-404a,
    R-404a gas charging,
    R-404a gas charging in ice cream storage machine,
    Refrigerant R-404a charging complete information,
    R-404a,
    Some Important video Links...
    Compressor Voltage and Speed relationship || Effect of voltage on RPM.
    • Video
    R-32 || R-32 complete information || R-32 Safety Precautions
    • R-32 || R-32 complete...
    R-410A || R-410A Properties || Safety Precautions and Complete information.
    • R-410A || R-410A Prop...
    Introduction to R-22 || R-22 complete information || क्या है आर-22 गैस
    • Introduction to R-22 ...
    How to test short in Water Coolor || How do you test water cooler || Troubleshoot in Water cooler.
    • Video
    How to repair old refrigerator || How to check compressor pressure || Flushing condenser with R-12
    • Video
    Thermostat adjustment for water cooler
    • Thermostat adjustment ...
    R-32 and R-410a Blasting reasons || Safety for R-32
    • R-32 and R-410a Blasti...
    How to Check Air Conditioning Unit Performance
    • How to Test split AC P...
    R-600a refrigerator leakage repair
    • R-600 Refrigerator Lea...
    Cone Ice cream machine || R-404a gas charging
    • R-404a gas charging ||...
    R-134a replaced by R-600a || Replacing capillary tube for R-600a || Capillary pressure adjustment
    • R-134a replaced by R-6...
    Freon Refrigerant Identifier or Analyzer || How to identify unknown refrigerant cylinder.
    • Freon Refrigerant Iden...
    Freon Electronic charging scale || Refrigerant charging by weight.
    • Refrigerant charging s...
    Gree AC wiring problem || Gree non inverter AC display not ON problem
    • Gree AC wiring problem...
    HVAC PCB Training, Free HVAC PCB Training course, (FK mech official)
    • Video
    R-600a gas charging || Inverter Refrigerator gas charging
    • R-600a gas charging ||...
    R-600a || How to choose genuine R-600a ? || How to select original R-600a in market.
    • R-600a || How to choos...
    R-600a gas complete information || Safe usage of R-600a || Steps to repair, maintenance R-600 unit
    • R-600a gas complete in...
    How to Know AC, Fridge gas genuine or bad quality. Good and Bad refrigerant
    • How to Know AC, Fridge...
    FK mech official,
    FK,
    FK mech,
    FK mach,
    FK mech official TH-cam channel,
    B-Tech in mechanical,
    All about the mechanical engineering,
    Refrigeration and Air Conditioning,
    Refrigeration and Air Conditioning course,
    Hvac related course,
    Refrigeration Theory,
    Thermodynamics,
    Engineering mechanics,
    Mechanical engineering course,
    Instructor Farman Khan,
    basics of refrigeration,
    FK mech official
    Thanks Dear for watching this video, please don't forget to subscribe my TH-cam channel
    'FK mech official'.

ความคิดเห็น • 114

  • @leftychang
    @leftychang ปีที่แล้ว +3

    Great video thanks! I was searching all over TH-cam and basically you answered / there is a pressure/temperature correlation - makes sense!

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      Thanks Dear Dave Chang for appreciation ❤️

  • @sanjaysharma8306
    @sanjaysharma8306 2 ปีที่แล้ว +2

    Thanks you sir I am very happy
    I am Frome Nepal so not use r404agass in Nepal but corrente time I work in Kuwait and confused so thank you ......

    • @FKmechofficial
      @FKmechofficial  2 ปีที่แล้ว +1

      How are you confused Dear ?

    • @sanjaysharma8306
      @sanjaysharma8306 2 ปีที่แล้ว +1

      I repair sopty ice cream machine and r404agass charging time problem sir
      How is suction presser80_90 not work

    • @FKmechofficial
      @FKmechofficial  2 ปีที่แล้ว

      @@sanjaysharma8306 are you Indian ??

    • @FKmechofficial
      @FKmechofficial  2 ปีที่แล้ว +2

      @@sanjaysharma8306 Dear for ice cream making the suction pressure of R-404a should be 10 to 12 PSIg

    • @sanjaysharma8306
      @sanjaysharma8306 2 ปีที่แล้ว +1

      No sir. I am Frome Nepal and only 2month come in Kuwait so that's region tkanku ..........

  • @italudin
    @italudin ปีที่แล้ว +4

    Liquid refrigerant must be fill at the discharge line sir, cause not good for the compressor if you fill at the suction line.filling the liquid first time when unit is off.
    Good if you put another charging line at the discharge line and use double scale LP+HP that is for better measuring pressure.
    Adding refrigerant to suction line when compressor ON with gas.
    Sorry if im wrong.
    Salam from Indonesia

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว +3

      Dear thanks for your valuable comments...❤️
      Dear sir, during charging the Refrigerant from discharge line is very difficult because the pressure at discharge line is higher than the pressure in Refrigerant cylinder...if we will connect cylinder with discharge line of the unit, the Refrigerant will flow from the discharge line towards the cylinder....

    • @italudin
      @italudin ปีที่แล้ว +1

      @@FKmechofficial is that corect sir, mostly im doing at compressor off, than adding and or reduce refrigerant at the compressor running. Thanks for sharing good video succes for you sir 👍

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      You are welcome Dear Sir ❤️

    • @ruzainirosli4940
      @ruzainirosli4940 ปีที่แล้ว

      @@italudin salam..bang saya dari malaysia,, boleh ajarkan saya masukan gas r404a untuk reefer tak,, kalau boleh bang tinggalkan nombor handfon saya akan wasap bang..🙏🙏

  • @zahidullah9627
    @zahidullah9627 10 หลายเดือนก่อน +1

    Very good job

  • @uttamjha7569
    @uttamjha7569 ปีที่แล้ว +1

    Ok sir, best performance for students.

  • @AyanMechanical
    @AyanMechanical ปีที่แล้ว

    Masha Allah nice information 👍

  • @ImranTech-hx4fu
    @ImranTech-hx4fu 10 หลายเดือนก่อน +1

    Good information brother

  • @azmathussain8232
    @azmathussain8232 2 ปีที่แล้ว +1

    Aoa bht achi video ha

  • @sandeepxaxa9330
    @sandeepxaxa9330 ปีที่แล้ว +1

    Ek no

  • @wasimedoo7994
    @wasimedoo7994 10 หลายเดือนก่อน +1

    Very good information bro god bless 👍

    • @FKmechofficial
      @FKmechofficial  10 หลายเดือนก่อน

      Thanks Dear brother ❤️

  • @HarisAhmad-zw3pi
    @HarisAhmad-zw3pi 10 หลายเดือนก่อน +1

    Very good

  • @TariqButt-y8u
    @TariqButt-y8u 12 วันที่ผ่านมา +1

    Aslaam o Alaikum
    Kaplarie tubes sizeee plzzz btaa dyyy

    • @FKmechofficial
      @FKmechofficial  12 วันที่ผ่านมา

      Wa Alaikumussalam,
      Bhai neeche video me details hain...
      th-cam.com/video/wnk4X64IrEM/w-d-xo.html

  • @muhammadmajid2931
    @muhammadmajid2931 10 หลายเดือนก่อน +1

    Thanks good information ❤❤❤

    • @FKmechofficial
      @FKmechofficial  10 หลายเดือนก่อน

      Thanks Dear brother ❤️

  • @udayuday7768
    @udayuday7768 ปีที่แล้ว +1

    Nice video sir thanks

  • @atifbukhari1505
    @atifbukhari1505 ปีที่แล้ว +1

    Good sir 👍

  • @usmanzaferlohar4960
    @usmanzaferlohar4960 ปีที่แล้ว +1

    Thanks sir for a great work

  • @nitinsawant5881
    @nitinsawant5881 7 หลายเดือนก่อน +2

    cooling coil flushing not done capillary and filter drier not replaced new one ok .

    • @FKmechofficial
      @FKmechofficial  7 หลายเดือนก่อน +1

      Ya, Sorry Dear
      It was just video about R404a gas charging.

  • @msaeed8031
    @msaeed8031 ปีที่แล้ว +1

    ❤ So nice

  • @nitinsawant5881
    @nitinsawant5881 7 หลายเดือนก่อน +2

    do the work with complete prosijor .

    • @FKmechofficial
      @FKmechofficial  7 หลายเดือนก่อน

      Sorry Dear brother,
      What's wrong in the video.
      Please highlight

    • @nitinsawant5881
      @nitinsawant5881 7 หลายเดือนก่อน +1

      this is wrong no shortcut for success remember that very well ok thanks 👍

  • @whathowwhy4629
    @whathowwhy4629 8 หลายเดือนก่อน +1

    Glass top deep freezer gas 404a but we replaced condencer with small one now. Condenser may be 5 to 6 ft only Is that effect the cooling propertyS? Pleas replay

    • @FKmechofficial
      @FKmechofficial  8 หลายเดือนก่อน

      Yes, it effects,
      If you will decrease condenser size then refrigerant can't be subcooled well,
      And cooling effect will be decrease

  • @qureshi1866
    @qureshi1866 ปีที่แล้ว +1

    For -40 temp only liquid refrigerant has to be charged or vapor will also have to be charged??

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      It should be charged in liquid state for best results

  • @ZahidKhan-jh9ul
    @ZahidKhan-jh9ul 2 ปีที่แล้ว +1

    R404 is best gas

  • @TheAkash2818
    @TheAkash2818 6 หลายเดือนก่อน +1

    Sir ji Compressor Kcm 475LALC310H 2 ton ac outdoor main laga sakte hai kulfi machine ke liye please sir data de dijiye

    • @FKmechofficial
      @FKmechofficial  6 หลายเดือนก่อน

      Brother Laga sakte hain,,, but ye 3 TR kelie design hoti hai

  • @MrMohsin226
    @MrMohsin226 8 หลายเดือนก่อน +1

    Dear if use 1 ton compressor and r404 refrigerant. Sir what will the capillary size and length also mention condenser and evaporater pipe

    • @FKmechofficial
      @FKmechofficial  8 หลายเดือนก่อน +1

      Condenser tube:
      Dia: 3/8
      Length : 48ft
      Condenser fan type
      Capillary Tube:
      Dia : 042
      Length : 4ft, 4ft ( Two Capillary Tubes)
      Evaporator:
      Dia : 3/8
      Length : 44ft
      Without fan evaporator

    • @mohdvasi8850
      @mohdvasi8850 4 หลายเดือนก่อน

      Sir dranfoss Sc21cl Compressor R404a gas Sir what will the capillary size And lenght

  • @muhammadwaqas2566
    @muhammadwaqas2566 ปีที่แล้ว +1

    Assalam-0-Alaikum Brother, Sir R404 minus 30 tak temperature lay jati ha....
    Kia is ko A.C may charge kar saktay hain...???

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      No,
      It's using for extra low freezing,
      In AC we don't need extra low freezing.
      Thank you for your valuable comments 🙏

  • @ASHISHKUMAR-cpr
    @ASHISHKUMAR-cpr 8 หลายเดือนก่อน +1

    Kcm475lal compressor me kitne no ka orifice lagega 30 kg ka 15 block ka plant hai kitna kg gas dalega

    • @FKmechofficial
      @FKmechofficial  8 หลายเดือนก่อน

      Expansion valve orifice TX2 lagega,
      Awr refrigerant capacity ke hisab se charge hoga brother ❤️

  • @arisdionela9755
    @arisdionela9755 3 หลายเดือนก่อน +1

    I Don, t know why liquid charging some refrigerant but liquid is danger to compressor parts 😅

    • @FKmechofficial
      @FKmechofficial  3 หลายเดือนก่อน

      Dear, all the blends refrigerants which are the mixture of two or more than two refrigerants should be charged in liquid for accurate ratio of each particular refrigerant.
      Yes liquid can be dangerous, but should be charged slowly.

  • @hape66666
    @hape66666 ปีที่แล้ว +1

    Sir makeline system r404 gas suction line ice problem i want to know the system how many gas required and back pressure if you know so please reply

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      What is your required temp in evaporator coil,
      Suction pressure depends upon the evaporating required temp.
      Also depends on application type.

  • @user-in5ki4tx9y
    @user-in5ki4tx9y ปีที่แล้ว +1

    sir, what is the suction pressure of this 404 gas for this type of refrigerator, I have measured a suction pressure of about 50psi, working current 2.5a, snow is half closed

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว +2

      If you have required temp: -30 ⁰C then you should have the suction pressure 10 Psig for R404,
      If suction pressure increases then your required temp: will also increase

  • @ziainfotv2576
    @ziainfotv2576 ปีที่แล้ว +1

    sir from which REFRIGERANT to get -70c temperature inside the cabinet i have a blood storage cabinet

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      In r404,
      But you should have a special system which has the blast type evaporator coil,

  • @sarfrazahmadfraz2983
    @sarfrazahmadfraz2983 ปีที่แล้ว

    great

  • @ruzainirosli4940
    @ruzainirosli4940 ปีที่แล้ว +1

    Hi sir.. how many charge for reefer r404a compressor 1.5hp -18©

  • @irfanhaider7115
    @irfanhaider7115 ปีที่แล้ว +2

    Sir I want to maintain -18 lequiid what should psig be?

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว +1

      Refrigerator or chiller, Cold Storage ???

    • @irfanhaider7115
      @irfanhaider7115 ปีที่แล้ว +1

      @@FKmechofficial Kulfi plant. Air cool.
      Can I get your WhatsApp no. For details.

  • @nidaassociates7441
    @nidaassociates7441 2 หลายเดือนก่อน +1

    Is softy machine lbp or mbp

    • @FKmechofficial
      @FKmechofficial  2 หลายเดือนก่อน

      LBP brother

    • @nidaassociates7441
      @nidaassociates7441 2 หลายเดือนก่อน

      @@FKmechofficial but in india it's consider MBP
      SOFTY MACHINE.

    • @FKmechofficial
      @FKmechofficial  2 หลายเดือนก่อน

      @@nidaassociates7441 No Dear,
      It is LBP, because the evaporator temp: is almost -30⁰C as you can watch in video

    • @nidaassociates7441
      @nidaassociates7441 2 หลายเดือนก่อน +1

      @@FKmechofficial sir maine apki machine ki nahin BLKI softy machine ki baat ko

    • @FKmechofficial
      @FKmechofficial  2 หลายเดือนก่อน

      @@nidaassociates7441 G ok

  • @ImranTech-hx4fu
    @ImranTech-hx4fu 10 หลายเดือนก่อน +1

    Can we charge r404 in refrigerator ?

  • @javedkasam8138
    @javedkasam8138 ปีที่แล้ว +1

    Use expansion valve or capalery?

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      Capillary tube

    • @javedkasam8138
      @javedkasam8138 ปีที่แล้ว +1

      Cold storage freezer for kcm475 compressor which size of capalery use

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      @@javedkasam8138 required temperature ???

  • @ShahzadKhan-hy8mt
    @ShahzadKhan-hy8mt ปีที่แล้ว +1

    And what is pressure r 600 if filled in ac split??

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      Dear Shahzad thanks to touch with us...
      The Refrigerant R-600 is not practically applicable in split AC, because it's heat bearing capacity is very low.
      ❤️❤️

  • @ninarohayati8286
    @ninarohayati8286 ปีที่แล้ว +1

    Tekanan berbagai macam freon

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      Dear brother,,, which language is this ❤️ ?

  • @nitinsawant5881
    @nitinsawant5881 7 หลายเดือนก่อน +1

    who will change the filter drier and capillary and flushing of the cabinet.

    • @FKmechofficial
      @FKmechofficial  7 หลายเดือนก่อน

      What do you mean brother ?
      Who or How ??

  • @babarshairbabar693
    @babarshairbabar693 ปีที่แล้ว +1

    پاکستانی ہیں بھائی جی۔خدارا اردو بولیں

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      صحیح بات ہے بھائ۔
      انشاء اللہ

  • @hamidnawaz6982
    @hamidnawaz6982 ปีที่แล้ว

    R404 is good gas

  • @tanvirulislam957
    @tanvirulislam957 ปีที่แล้ว +1

    R404 high pressure?

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      No.....not so much high pressure,
      It's suction pressure should be from 10 Psig to 25 Psig according to the application type

    • @tanvirulislam957
      @tanvirulislam957 ปีที่แล้ว +1

      @@FKmechofficial tell me, condenser temp+ pressure.

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      @@tanvirulislam957 condenser pressure is from 220 to 260 Psig

  • @omhri853
    @omhri853 7 หลายเดือนก่อน +1

    This unit diagram

    • @FKmechofficial
      @FKmechofficial  7 หลายเดือนก่อน

      Wiring ??

    • @omhri853
      @omhri853 7 หลายเดือนก่อน +1

      Nhi evaporation and condenser and capillary

    • @FKmechofficial
      @FKmechofficial  7 หลายเดือนก่อน

      @@omhri853 ok

  • @rehanrana2224
    @rehanrana2224 ปีที่แล้ว +1

    یہ فریزر کہاں سے ملے گا؟

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว +1

      Ye Local Bana hwa hai....Kisi mechanic ne banaya hai...

    • @rehanrana2224
      @rehanrana2224 ปีที่แล้ว +1

      @@FKmechofficial karachi main kae jaga poocha ha koe info ya detail nahe mile

    • @FKmechofficial
      @FKmechofficial  ปีที่แล้ว

      @@rehanrana2224 pyare bhai local Ka MATLAB ye aap khud se bhi Bana sakte ho...

    • @rehanrana2224
      @rehanrana2224 ปีที่แล้ว

      @@FKmechofficial guide pls karegar ko ja ker kia bolna ha kia mechine lagae kia compreser lagae kia gas bhare kia boloon? Pls guide

  • @malikt113
    @malikt113 ปีที่แล้ว +1

    Yar urdu bola karo