16 3. Manual of PCI - DK crush troubleshooting

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ม.ค. 2025

ความคิดเห็น • 17

  • @MP-co6hp
    @MP-co6hp 4 ปีที่แล้ว +1

    Wow,amazing.Would love to get a few weeks training under you...Great teacher ....

  • @svijaykumarreddy1242
    @svijaykumarreddy1242 3 ปีที่แล้ว

    Lucid presentation of DK CRUSH

  • @zfrost8431
    @zfrost8431 4 ปีที่แล้ว +1

    thanks. I like to rotate the balloon slightly clockwise and counterclockwise a little when inserting through the stent cell. usually works

  • @matheuscsmed
    @matheuscsmed ปีที่แล้ว

    Thank you, Matheus Silva

  • @shangz0216
    @shangz0216 4 ปีที่แล้ว

    Thanks for your educative presentation.

  • @Hshirata
    @Hshirata 4 ปีที่แล้ว +1

    Great explanation! Always easy to understand and to follow in the Cathlab. In a routine non complicated DK-crush, how many GW an balloons you usually use?

  • @georgetouma5430
    @georgetouma5430 4 ปีที่แล้ว

    Dear Manos
    Ultimaster 2.25 to 3.0 mm expands to 4.5 mm. It’s the best stent for size mismatch.
    Also the risk with very small balloons is they travel under struts easily. I would suggest the POT crush step first and avoiding a balloon below 2.0 mm where possible.

    • @manosbrilakis
      @manosbrilakis  4 ปีที่แล้ว

      Thank you - excellent point - Ultimaster is not available currently in the US.

    • @MinorityDoc
      @MinorityDoc ปีที่แล้ว

      Great point 👍🏻

  • @micger
    @micger 4 ปีที่แล้ว

    Thank you for the brilliant video. My only comment is that if it is that hard to cross the balloon into SB then I would consider the possibility of the wire being underneath the stent strut and will rewire it. I don't normally like to push too hard with balloons

  • @mohammadjaber6387
    @mohammadjaber6387 4 ปีที่แล้ว

    Great as always
    Many thanks

  • @bogdanmaslij9704
    @bogdanmaslij9704 4 ปีที่แล้ว

    Thank you for brilliant video lessons! What is your opinion about DK Culotte? I tried it twice and was wery happy with result.

    • @manosbrilakis
      @manosbrilakis  4 ปีที่แล้ว

      I do not have any experience with it, hence cannot comment.

    • @georgetouma5430
      @georgetouma5430 4 ปีที่แล้ว

      @@manosbrilakis DK culotte should be the default strategy when performing modern culotte. It basically involves a POT at each point after stent deployment and a kiss after each stent deployment followed by a final POT.
      It greatly facilitates the procedure and minimises the risk of passage under stents and stent deformation that goes unrecognised angiographically.

  • @ahmedzahran7016
    @ahmedzahran7016 8 หลายเดือนก่อน

    The most dreadful step is deploying the main vessel stent jailing the SB wire between to metal struts,