Salam bhai bhai ac check kia or us ka back pressure 90psi tha ,or ac cooling bohat kam thandi hawa through kar raha tha,pehlay jab ma nay is ko teyaar kia tha us waqat back pressure 60psi tha. (4 ton acson 3 phase zr61 Copeland compressor)
Lg ka split AC r22 1.5 ton usme problem hai ki pahle to ac 7-8 minut chal raha hai running pressure 40 lekar aur ampire 6-7 fir uske baad compressor 12-16 ampire tak chala ja raha hai aur pressure bhi 170-180 tak jakar outdoor trip kara Raha hai 2-3 second me baar baar chalu band ho raha hai outdoor kya problem ho sakta hai
Sir ek Mitsubishi havey duty ki r32 gas hai usme suction pressure 200+ bata rha or discharge bhi 200+ hai 15 minutes chalata hai or outdoor band ho jata fir thodi der baad chalta hai Fir 15 minutes to chlata hai Fir band ho jata hai aise hi do baar band ho ke tisri baar me timer wali light blinking krne lgti hai continue blinking krti thi hai Isme kya foult ho skta hai plz bata do
Compressor ka pump less ho jae kaise check krenge koun koun sa mathod hota hai
Salam bhai
bhai ac check kia or us ka back pressure 90psi tha ,or ac cooling bohat kam thandi hawa through kar raha tha,pehlay jab ma nay is ko teyaar kia tha us waqat back pressure 60psi tha.
(4 ton acson 3 phase zr61 Copeland compressor)
Mind blowing sir ji 🌹♥️💕
Lg ka split AC r22 1.5 ton usme problem hai ki pahle to ac 7-8 minut chal raha hai running pressure 40 lekar aur ampire 6-7 fir uske baad compressor 12-16 ampire tak chala ja raha hai aur pressure bhi 170-180 tak jakar outdoor trip kara Raha hai 2-3 second me baar baar chalu band ho raha hai outdoor kya problem ho sakta hai
Sir r32 gas hai 1tan ki a.c back periser bhi chek kar liya 120se140 tak karliya lekin kuling nhai kar rha hai
Short video bana do sir 19 /4/2023 mai AC thik karne aya tha likin kuling nahi kar rha hai to
Great thanks sir 👍👍👍
Stating peresar 350 hai ky probal
Sir ek Mitsubishi havey duty ki r32 gas hai usme suction pressure 200+ bata rha or discharge bhi 200+ hai
15 minutes chalata hai or outdoor band ho jata fir thodi der baad chalta hai
Fir 15 minutes to chlata hai
Fir band ho jata hai aise hi do baar band ho ke tisri baar me timer wali light blinking krne lgti hai continue blinking krti thi hai
Isme kya foult ho skta hai plz bata do
विंडो एसी का कोई पेप आगर बीच से लीकेज हो तो उसका कनेक्शन काटकर उसे वाईपास कर सकते हैं
Thanks for telling you sir
R22 gas,6400w ac ,standing 120 psi,back 0 psi ,ac not cooling ,what is the matter?
Dada mera voltas ka inverter 1.5 tn ac rat me chalta he 1 ye 2 ghanta lekin din me ac compresser on hote hi mcp trip down ho ja ta he plz help me
❤❤. super n1
Suction line per ice aayega na Sir ji 🌹🌹♥️
Ha
Bhai mera ek sval hai ac thechnitian aur electrician dono me se kon kam sikhna chaye coment me hi jvab degiya ga plese bhai
Ac ka
Ac warking but dire hite no collinge saction pesor 200 Regine
Sir split ac kaa full waring bta dejiya plzz suru see last tak