Passive Solar Design - What is thermal mass?

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 พ.ย. 2024

ความคิดเห็น • 11

  • @fatenashour1063
    @fatenashour1063 4 ปีที่แล้ว

    Thank you

  • @Lawiah0
    @Lawiah0 10 ปีที่แล้ว +2

    Insulate the thermal mass on the Outside (cold side).
    see Dry Stacked Concrete Blocks

  • @SvenvandeBergh
    @SvenvandeBergh 9 ปีที่แล้ว +1

    How is this related to IR-heating and solar panels?

  • @dbaggs011
    @dbaggs011 8 ปีที่แล้ว +1

    OK explanation of winter benefits but a missed opportunity to up front clearly explain the benefits and mechanisms of thermal mass cooling (gets there in the end though) and the role of thermal mass in sub-tropical climates when its winter and not humid and in summer when days are still way hotter than the nights and thermal mass will benefit even in SE QLD..

  • @seumas2
    @seumas2 5 ปีที่แล้ว +2

    In the Heart of Vancouver Island BC Canada passive videosth-cam.com/users/seumas2videos
    Material used
    Port
    Alberni's first Passive house (Passivhause) build in the heart of
    Vancouver Island British Columbia Canada.
    Passive
    House(Passivehaus) is considered to be the most rigorous
    voluntary energy-based standard in design and construction industry
    today.
    Passive
    house buildings consume up to 90 percent less heating and cooling
    energy than conventional building.
    The
    use of Passive House design software was used to gain the specs
    required to meet the performance standard for this location.
    House
    was constructed well above the current standards as outlined in
    the B.C. Building Code.
    Footings
    were widen to 36 inches(914 mm) due to low bearing soil conditions
    and additional rebar reinforcement added.
    30
    inch high (762 mm) high reinforced walls . Course sand placed inside
    foundation walls and mechanically compacted.
    Three
    layers of four inch *102 mm) thick Expanded
    polystyrene foam sheets with all joints staggered and tape were
    placed on top of compacted sand.
    The
    three layers of foam have insulation value of approximately R 50.
    A
    20 mil layer of poly was placed over the E.P.S. sheets and taped and
    sealed.
    Four
    inches(102 mm) of 30 m.p.a fiber reinforced concrete was placed to
    form a slab over the foam based.
    Slab
    is isolated from concrete stem wall with four inches (102 mm) of
    E.P.S. to prevent thermal loss.
    All
    cold water lines are buried in the sand to keep them cool, hot water
    lines have been placed in the center layer of foam insulation to
    minimize heat loss.
    Wall
    plates compress to heavy beads of acoustic sealant between layers of
    vapor barrier to prevent air movement.
    The
    walls are double stud configuration set at 24 inches (610 mm) on
    centre and plates are spaced in a manner that yield a 20 inch (508
    mm) thick wall. 1/2 inch (12 mm) standard plywood sheathing with
    Mento 1000 a three layer airtight vapor open house wrap( far superior
    to common house wraps) with 1/2 inch(12 mm) pressured treated plywood
    rain screen battens form the exterior surface.
    Intello
    smart vapour barrier was installed one third in from the inside wall
    to prevent condensation in this climate.
    Triple
    pane argon filled windows meeting passive house standards from
    Euroline were placed mid wall to reduce wind wash heat loss.
    All window openings have been splayed at 45 degrees to give a full
    wide angle view.
    Almost
    all the wiring and plumbing was kept inside of the vapor barrier
    envelope to minimize air leakage.
    Passive
    house standard requires air leakage not to exceed .6 Air
    changes per hour at 50 pascal.
    Zehnder
    comfoair 200 HRV has been installed with a 1000 watt air preheater
    .(92 percent heat recovery rate)
    House
    has been pre- plumbed for a heat pump water heater reducing
    domestic water heating cost significantly.
    Garage
    has been pre-wired for 40 amp/240 volt electric car charging
    station.
    House
    to be equipped with heat pump condensing dryer which
    requires no external venting,only a water waste line. George K
    Builder. © George K 2019
    th-cam.com/users/seumas2videos

  • @sylviayakubu6575
    @sylviayakubu6575 5 ปีที่แล้ว

    Want if there is no sun to absorb ...can then heat be absorbed from the heater rather

  • @seigeengine
    @seigeengine 9 ปีที่แล้ว +25

    So let's spend almost 14 minutes poorly explaining a simple concept. Brilliant.

    • @callmeswivelhips8229
      @callmeswivelhips8229 7 ปีที่แล้ว +1

      Seriously lol

    • @ziabashir
      @ziabashir 2 ปีที่แล้ว +1

      Appreciate someone efforts teaching or learning,

  • @littlemommielikkun
    @littlemommielikkun 4 ปีที่แล้ว +1

    Give a simple answer geez

  • @callmeswivelhips8229
    @callmeswivelhips8229 7 ปีที่แล้ว +3

    That woman really had no idea what she was talking about. Just listen to her first sentence. "WOW, I have no idea how to explain this!" Of course this is followed by her saying the same thing over and over in different ways. Bullshitting doesn't end after high school I guess. The guy was much much better.