SOLARKIT - Deye inverter installation - a STEP-BY-STEP guide

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ม.ค. 2025

ความคิดเห็น • 13

  • @SiBex_ovh
    @SiBex_ovh 6 หลายเดือนก่อน

    6:25 best way is say it's a order of 3 phase like proper L1+L2+L3 or L1+L3+L2 what have impact on rotate direction of electric 3phase motors and everyone say... ohh Now I see, nice to have that.

  • @gerardortezajr.1824
    @gerardortezajr.1824 3 หลายเดือนก่อน

    Hello, will my inverter be in operation if i only connect the inverter’s grid terminals to the building main circuit breaker and connect lifePO4 batteries? Please take note that we will not use the LOAD TERMINALS of the inverter. Will it be operational?

  • @AYODELENAJEEMDEEN
    @AYODELENAJEEMDEEN 5 หลายเดือนก่อน

    I connect panels to Dye hybrid not connected to Dye hybrid inverst system

  • @LanderNzube
    @LanderNzube 4 หลายเดือนก่อน

    Please I'm yet to understand what is the smart load and it's functions,also the aspect of Gen port

    • @pertz7843
      @pertz7843 4 หลายเดือนก่อน

      Smart load works when you have surplus production. This means when your batteries are fully charged, no load, and still have sun, you can use the gen port to power things.

  • @nt4hx
    @nt4hx 11 หลายเดือนก่อน

    System work mode > zero-export power: 20. What is this actually? I'm a little bit confuse but from my understanding it will use the grid (build in CT) power to sense the voltage, current and frequency to match with generated AC power by the inverter. However, my meter still detect I'm using about 1.2 A from grid all the time. I've battery connected everything should run by the battery but not sure why. There's people also reported this on the forum. I've set this zero-export power to 0 but still my enerygy meter is showing I'm using about 1.x A all the time to power the inverter (mine is 8kw and grid is 240VAC) so means I'm using about 300w from grid all the time. All my house power connected to smart load. In deye app it showing 1A but on graph it showing I'm importing 0.

    • @SolarKitEurope
      @SolarKitEurope  10 หลายเดือนก่อน +2

      As load amount changes quickly when a device is shut down, the inverter cannot reduce the power at the same rate. So, to avoid injecting electricity back to the grid when it is not allowed, there is a given consumption that is always drawn from the grid first before the inverter starts up. Depending on the amount and type of electrical appliances, this number could differ. If the meter shows that the system is injecting back to the grid when it should not, then this number needs to be increased. We suggest starting with 20 W, as it is usually sufficient for many households and won't significantly affect performance. This adjustment serves regulatory purposes only.

    • @nt4hx
      @nt4hx 10 หลายเดือนก่อน +1

      @SolarKitEurope Let me rephrase again - here is the scenario: during the day, My PV is generating enough power to charge my battery bank and to supply house consumption (connected to inverter smartload output). the rest of excess power generated by PV are being sell to the grid. This is good. When turns evening, night or PV not generating enough power to supply, battery will supply power to smart load. Grid should remains idle as there's are not enough power to sell, however grid consumption is at 1A I'm importing 1A all the - not sure why? The inverter should be powered by the battery as well. I've set this configuration. If it's using maybe 0.2 A i don't mind but, 1A is about 300W (depending on pf) for standby.. x24 hrs x30 days that's about 200kwh which is quite substantial.

    • @odoohub5010
      @odoohub5010 8 หลายเดือนก่อน

      ​@@nt4hxyou can turn off grid charge, if that does not work, then do it manually by installing an isolator between your grid and inverter grid input, then switch the grid off.

    • @محمودمغاري-خ8ف
      @محمودمغاري-خ8ف 2 หลายเดือนก่อน

      Hello, I want to ask you about the inverter. It gives an alarm outside the manual. Alarm.comm. ​@@SolarKitEurope

  • @وسيماحمدعبدالجليلالكهربائي
    @وسيماحمدعبدالجليلالكهربائي 4 หลายเดือนก่อน

    Please write a book.

  • @Chris-hw4mq
    @Chris-hw4mq 5 หลายเดือนก่อน

    Why would I let you give me access to my equipment. I am the admin not you.

  • @junaidahmed8966
    @junaidahmed8966 หลายเดือนก่อน

    I have never seen a worse inverter than Deye