dear sir please check in your previous videos you have V rms is sqrt of summation all voltages but in video Detuned Filter Detuned filter reactor Harmonic filter you have added all voltages instead of sqrt of square of all summation please check for capacitor voltage is only 455 v and nearest available is 480v thats why in market if we buy any reactor @ 7 % detuned they have combo pack of capacitor @ 480 v please revert thank you for your excellent information and your thought for educating others like me
Hi.. Ihave 3 quations.. 1) how to select reactor percentage to add in series with capacitor? 5% , 6% or why 7%? 2) If there is no VFD or harmonic generating load, say only water supply pums then is it require to add Detune reactor With Power factor corection capacitor panel (APFC)? 3) from where this values are arrieved U1=6% , U3=0.5%, U5=5%, U7=5% arrived *please* clarify. Your videos are very good and informative...All the best for future👌👍
values come from load site meter only if you have any meter to measure it will show directly voltage corresponding to different harmonics make V rms make sqrt of summation of all harmonic voltage you will get final voltage
Very informative Sir, but please tell me one thing. This calculation is for existing Capacitor bank we have without reactor but if I'm Planning to install new Capacitor bank how we will do all such calculation? Please reply
Good morning, my name is Martino Rizzo and I am a student of Electrical Engineering at the UBA. Sorry for the inconvenience, I am writing because I have to carry out an engineering problem that consists of sizing a detuning reactor. I wanted to know if you could offer me any help for this job. Thank you very much in advance and again I apologize for the inconvenience.
The assumed value of installed kavar is 50 kvar in an harmonic enviroment. You have to put an 80 kvar 525 V capacitor in series with 6% detuned reactor to get 50kVAR reactive power compensation.
Bro can you make this video in English so it would be more helpful.. please
Soon you will get it's subtitle in English and hindi😊
Sir ji what is detuned reactor linearity please explained
dear sir please check in your previous videos you have V rms is sqrt of summation all voltages but in video Detuned Filter Detuned filter reactor Harmonic filter you have added all voltages instead of sqrt of square of all summation please check for capacitor voltage is only 455 v and nearest available is 480v thats why in market if we buy any reactor @ 7 % detuned they have combo pack of capacitor @ 480 v please revert thank you for your excellent information and your thought for educating others like me
Great
Excellent....sir ji
Hi..
Ihave 3 quations..
1) how to select reactor percentage to add in series with capacitor? 5% , 6% or why 7%?
2) If there is no VFD or harmonic generating load, say only water supply pums then is it require to add Detune reactor With Power factor corection capacitor panel (APFC)?
3) from where this values are arrieved U1=6% , U3=0.5%, U5=5%, U7=5% arrived *please* clarify.
Your videos are very good and informative...All the best for future👌👍
values come from load site meter only if you have any meter to measure it will show directly voltage corresponding to different harmonics make V rms make sqrt of summation of all harmonic voltage you will get final voltage
Excellent explanation.Thsnks
Very informative Sir, but please tell me one thing. This calculation is for existing Capacitor bank we have without reactor but if I'm Planning to install new Capacitor bank how we will do all such calculation? Please reply
Can you please explain me about harmonic limit level indicated value calculated? Thank you
Excellent information. Only one question for series reactor is 3 phase or single phase.
Good morning, my name is Martino Rizzo and I am a student of Electrical Engineering at the UBA. Sorry for the inconvenience, I am writing because I have to carry out an engineering problem that consists of sizing a detuning reactor. I wanted to know if you could offer me any help for this job. Thank you very much in advance and again I apologize for the inconvenience.
Tnx
Good
Where did reactive power 50 kvar came from?
Same Doubt here
The assumed value of installed kavar is 50 kvar in an harmonic enviroment. You have to put an 80 kvar 525 V capacitor in series with 6% detuned reactor to get 50kVAR reactive power compensation.
Why You Consider U3=.5%, ? & U7=5%
Same question
Type of reactor like 5% 6% 7%
@@educationwithcareers2880thats not valid answer. Then why 0.5% for U3? And same for rest?
If you look at reactor manufacturer data it is standard for 7% detuned reactor for voltage harmonics handling in percentage @@syedahmed144