MITSUBISHI FX5U PLC MODBUS TCP IP COMMUNICATION

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 ม.ค. 2023
  • MITSUBISHI FX5U PLC MODBUS TCP IP COMMUNICATION
    PREVIOUS VIDEO LINK
    • FX5U PLC BUILT IN RS-...
    • MITSUBISHI PLC R-SERIE...
    • HOW TO USE LDP(RISING ...
    • HOW TO USE MATHMATICAL...
    • HOW TO USE COMPARE INS...
    • CC-LINK IEF BASIC COMM...
    • HEADER MODULE (M-CCB-H...

ความคิดเห็น • 17

  • @nishantkaushik3047
    @nishantkaushik3047 ปีที่แล้ว +1

    Very informative video bhai ji

  • @prashantdixit4427
    @prashantdixit4427 3 วันที่ผ่านมา

    How to print barcode please share plc programming and ethernet configuration of zebra printer

  • @surajgoswami3138
    @surajgoswami3138 ปีที่แล้ว +1

    Bahut aacha laga

  • @monuatkan5129
    @monuatkan5129 ปีที่แล้ว

    Thank you sir

  • @kamalmunjal6380
    @kamalmunjal6380 ปีที่แล้ว

    sir hamri company me ak sath 12 PLC fX CPU vali CCL m se connected h please uspe ak tutorial bnaye configuration ka sbki ip kha se assign hogi and I/O

  • @lovey6632
    @lovey6632 6 หลายเดือนก่อน +1

    I have FX-5U PLC, Can we read or write data from other brand VFD over Modbus TCP IP protocol

    • @automationwithdeepak4628
      @automationwithdeepak4628  6 หลายเดือนก่อน

      Yes

    • @lovey6632
      @lovey6632 6 หลายเดือนก่อน

      Then in that case, what should be the steps, how should I need to put the data register
      Should I start it with D..... OR DIRECTLY add data register number

    • @lovey6632
      @lovey6632 6 หลายเดือนก่อน

      I would recommend you to please make vedio on schneider vfd communication with FX-5U plc

  • @inshaengineering9679
    @inshaengineering9679 ปีที่แล้ว

    You have to Improve with Hardware

  • @bjbalaji9103
    @bjbalaji9103 ปีที่แล้ว +1

    This is master or slave ji

  • @trolingmaster23
    @trolingmaster23 7 หลายเดือนก่อน

    Hello, can you please help me? I can't select tcp communication because it is not showing up

    • @automationwithdeepak4628
      @automationwithdeepak4628  7 หลายเดือนก่อน

      Follow the video I am sure you make communication easily.

    • @trolingmaster23
      @trolingmaster23 7 หลายเดือนก่อน

      @@automationwithdeepak4628 when I try to download the program to the PLC it says that it won't download because my PLC (FX5U-32M) is not compatible with simple communication. I have seen in other tutorials that I must select active communication instead of Modbus tcp in module configuration. After that, supposedly I need to add TCP protocol in online>predefined protocol
      When that is added, the TCP asks me to add the specific read or write command number for communication (1,3,6,16 etc)
      When that is done, I need to configure which devices (D#) are going to be read for the Modbus TCP communication (Id number, head register, number of registers to read)
      Finally, the ladder logic, I think the command is sccom or something like that
      I can't try all of this because until Monday I go back to the office, but if you have the PLCs at hand and if you can try it, please tell me if it worked

    • @trolingmaster23
      @trolingmaster23 7 หลายเดือนก่อน

      I don't understand why, but it seems some people configure just the protocol, others use simple communication, others configure the protocol AND choose the active module.
      I must be doing something wrong because it should not be that difficult
      I mostly use Siemens, my Mitsubishi PLC is brand new out of the box, but as I told before, the list of connection does not display Modbus TCP, only "melsec/ iQ communication" and when downloading an error occurs that says that my PLC does not support simple communication, and if I force it the PLC shows error Status
      Please see attached video th-cam.com/video/urEttsQ_k8c/w-d-xo.htmlsi=JU9m7QqqXaygAQEm