    Position Register mode or PR Mode is ideal for those times when you just need the servo system to repeat the exact same sequence of events over and over again. You just setup a path from point 1 to point 2, then to point 3 then to point 4, etc. And the SureSServo2 Servo System has tons of options that make it super flexible. In this video we'll use the SureSerrvo2 Pro software quickly to setup and configure Position Register mode and show you all the various options.
    To learn more visit www.automationdirect.com/servo
    All SureServo2 Videos: • SureServo2 - All videos
    Check out all of our videos at www.AutomationDirect.com/Videos
    or at www.automationdirect.com/cook...
    To subscribe: th-cam.com/users/automati...
    Facebook: / automationdirect
    Twitter: / automationdirec
    LinkedIn: / automationdirect
    **Prices were valid at the time the video was released and are subject to change.
    Related AutomationDirect.com part numbers: SV2A-2040, SV2A-2075, SV2A-2150, SV2A-2200, SV2A-2300, SV2A-2550, SV2A-2750, SV2A-2F00, SV2L-201N, SV2L-201B, SV2L-202N, SV2L-202B, SV2L-204N, SV2L-204B, SV2L-207N, SV2L-207B, SV2L-210N, SV2L-210B, SV2M-210N, SV2M-210B, SV2M-215N, SV2M-215B, SV2M-220N, SV2M-220B, SV2M-230N, SV2M-230B, SV2H-245N, SV2H-245B, SV2H-255N, SV2H-255B, SV2H-275N, SV2H-275B, SV2H-2B0N, SV2H-2B0B, SV2H-2F0N, SV2H-2F0B, SV2-PRO, SVA-2040, SVA-2100, SVA-2300, SVL-201, SVL-201B, SVL-202, SVL-202B, SVL-204, SVL-204B, SVL-207, SVL-207B, SVL-210, SVL-210B, SVM-210, SVM-210B, SVM-220, SVM-220B, SVM-230, SVM-230B, SV-PRO
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 8

  • @joshuawhitelaw3826
    @joshuawhitelaw3826 2 ปีที่แล้ว +2

    The Position CMD Data(PUU) field in the PR Mode, Data portion, is there a parameter you can set the value of this field and then run the path by setting the P5.007 parameter which would look at this register to go to this position?

    • @automationdirect.comdrives1506
      @automationdirect.comdrives1506  2 ปีที่แล้ว

      Hi Joshua,
      I think you want to write a position to a PR Path and then run that path - is that right? If so, that's easy.
      Example:
      Write 50000 to P6.00 which is the position register for path 2.
      Trigger the execution of path 2 by writing decimal 2 into P5.007.
      As long as the drive is enabled and ready, then Path 2 should execute with the new position data (50000).

  • @ammarsalim2424
    @ammarsalim2424 2 ปีที่แล้ว +4

    Thank you
    Is there a pr mode triggering vedio?

    • @automationdirect.comdrives1506
      @automationdirect.comdrives1506  2 ปีที่แล้ว +3

      Not yet, but it is on our list ...

    • @ammarsalim2424
      @ammarsalim2424 2 ปีที่แล้ว +1

      Thank you
      I hope that will be soon

    • @bryanludgate5673
      @bryanludgate5673 5 หลายเดือนก่อน

      @@automationdirect.comdrives1506 Did it make it to the top of the list yet? Thanks, B

    • @bryanludgate5673
      @bryanludgate5673 5 หลายเดือนก่อน

      Disregard, th-cam.com/video/YO5OzRL60ro/w-d-xo.html has enough information to do so.

    • @automationdirect.comdrives1506
      @automationdirect.comdrives1506  5 หลายเดือนก่อน

      @@ammarsalim2424 the video is here! Thank you for your patience!
      www.automationdirect.com/videos/video?videoToPlay=OvMKSDX_4PY&cat1=50&cat2=81&cat3=200?WDYGoWQYzw&VideoTeamDescription