This is Cummins HMI 211 Controller in a diesel generator
Watch how to find fault by code
and reset how to give power command
6 wire star delta motor connection
👉 • how to make 6 wire sta...
DOL starter Panel wiring in hindi
• Pump control automatic...
star delta Panel making
• Star Delta starter con...
#rajeshelectrical #cummins #rajeshelectricalsgurgaon
welcome to Rajesh Electricals Gurgaon
contact us for any types of electrical work
www.indiamart.com/rajeshelect...
email rajeshelectricalggn@gmail.com - วิทยาศาสตร์และเทคโนโลยี
Am new in hotel building doing night shift no knowledge of genset
hotel mai guest aisi tasi kr rhe tge light ki wahaj se.. aapki video ko dekh kr genset on kiya thank you.
Smaal video but asardar video👍
very good information dear keep it up
Hello sir, after running manually how to keep this in auto mode.????
HELLO SIR, WE HAVE SAME GENERATOR HERE KINSHASA CONGO..I AM LOOKING THIS PART..PLEASE SEND ME LINK TO PURCHASE FROM INDIA..THANKS FOR THE INFORMATION
Good day Sir. We have the same controller. How can I set the time to switch off shorter... It takes about 6 mins to switch off.
Sir meri bhi company me yehi DG or yehi hmi hai,usme warning light jal Rahi hai,jis karan hmi display humesha on rehti hai.use reset kaise kare ya band
sir please ek or video banao jisme external auto or manual connection
Sir pls update dg full parts operation and functions,sir ..
Aapka adress kha pr h gurgao me
Diegel ka parsant kaise dhak sakte hai sir
Dg sarvasing karana hay gangtak pay
Sir auto changer ke setting kaise check karte hai
Hi
Iam suffering of demo mode of generator its appear on screen
I want solution for this problem to clear demo mode
Señores buen día como ago para con seguir el manual en español de Generadores cummins en Colombia
Sir hours ko edit kr skte hai kisi treele se , g.k liye puch rha hu , manually hours reading ko , increase -decrease kr skte hai
No hrs. ko edit nhi kr skte or esa krna gairkanooni h
Sir Power command HMI 211 ka 1845 fault reset nahi ho rha hai kya kare
Sir agar same DG me HMI me koi problem aa Jaye to manually kaise start Kar sakte hai
ESR k no pr jumper wire se start ho jayega wire start hone k bad hta deni h
My command power hmi220 in demo mod, how to change it to normal mod
Sir thank for guidance. Our 250 kva genset showing V12 error code and stoping. Please advise.
Kon si company ka DG h or controller h model kya h controller ka
How do I clear the faults?
Sir hamar Gen set ko start karty Hay to self operations hot Hay butt fuel on Nahi ho raha
Fuel nozzle ko bhar nikal kr tb self on fuel sprey hota h ya nhi lakin us se phle fuel filter ko jroor check kro
Sir mere yahan ats panel laga hai usmein ats controller laga hai usme no point hai dg ko start command bhejne ke liye auto mein ,kya aap bata sakte hai ki wo do cable kahan lagega.
Controller kon si company ka h dekhna pdega
@@RajeshElectrical socomec ka laga hai sir ats c20
Bhai Google me type kro atys c20 manual wha se pdf file download kr lo usme sare connection h
Sir remote start kase hoga
como se hace para entrar a la programaciom
Sir rpm kasy set kasa kary
❤❤❤
Sudhir gensets cummins 180 kva
Sir, we have the same HMI unit. It goes to Auto to " Not in Auto" mode by itself. Once it is auto after 20-22 hrs it goes to "Not in Auto" mode. Could you give some feed back
Remove battery + wire from battery terminal wait 5 minutes then reconnect
Reading kaise badhaye
sir in 250kva dg when start the engine running only two minutes then automatically stop what problem there.
Display me kya show hota h
DG error code 1246 ka matalab Kia hai sir
Do you know the pass code to be able to disable AVR ?
Sir apna DG me charger lagaya aur Auto mode me dala kuch din pehle abhi powerCommand HMI211ka display fade hone laga hai. Thik se dikhta nhi hai hours wagera. Kya ho sakta hai
Hmi ki internal display change hogi ya fir pura hmi controller change hoga charger ki output voltage limit se jyada nhi honi chahiye
27 volt hai
@@RajeshElectrical Aur Display sleep mode pe nhi jaa rahi ab. Anytime on rehti hai. Sleep pe kaise daale?
Shutdown ka error aa raha he to kya karna hoga
Hello sir, how we can reset the engine hour reading in HMI 211
Not possible bro
BRAZIL ,ELETRICIAN MESHIAH
Hello sir, I am a great fan of your content, so knowledgeable. I have a question sir- I have purchased a second hand 125kva Cummins DG and I wanted to reset the working hours, please help me in this. Thanks in advance sir🙏
Jb aap HMI me total hrs. Me phuchoge tab options me jana vha pr reset hrs. pr click krna tb apse enter password bolega
Ager app shi password enter kroge to definitely hrs. Reset ho jayege
@@RajeshElectrical
Jackson H/office Address
sir ji dg ko manual kar ke or fir se aouto start kense karen
Panel ka photograph send kro
Sir j 180kva ka sit down hatane ke liye Kya Karen
Kya shut down display me dikha rha h ?
Yes sir
125KVA ka DG set ka panel me establishing communication with control dikhata hai, kya kare
Dg ki jo wiring dg k control Panel yani jo display se connect h unki proper connectivity nhi h
Sar DG per warning Kyon deta hai
Sir can you please tell me reset emergency stop
Bhai emergency Push button ko release kr do or ecp se reset press kro ho jyrga
Sir warning light kab jalti hai
Jb koi internl problam aati h
CRC error in seriel flash q aata h
Sir RS485 PORT HAI KYA
Nhi h bro mera sorry
Band Kane ka tarika
Hello sir reading kaise badhaye
Kon sa DG h
Shutdown problem kaise hatai
Emergency switch k wire aps me short kr k check kro
Hello Sir I have an query
Yes
How reset fault code 1845
PCC 1301 controller
Shut down, not in auto display, start ho raha hai but off after start
Rajesh ji = Apa ki Phone Number? 750 KVA Cummins ki power command chahiye. Namaste.
Sir mere fb page pr mera no mil jayega
320 kva ka dg kitna load leta hai 80%
Or full load kitna leta hai
Plz riplay
Kva ×1.39 = full load amp. -- 80%
@@RajeshElectrical 80% load kitna leta hai
220 tak leta hai kya
320 kva ka dg
Remort start kese hatega sir
Yes pls help
What help
What help
O fore Ji Kya Karen sar display बार-बार off Ho Rahi hai Kya Karen
Loos connection ho skte h
Start hone par lood aage nahi jata to ky kare lood kese chack kare
Engine ko check kro sab kuch ok h alternator ko bina load k chla kr voltage check kro
Cummins CS 250D5P
Controller kon sa h power start ya power command
@@RajeshElectrical power command. 1301 HMI control
Sir please help me ..it's very urgent ....
HMI 211 controller sleep mode ho jane k bad auto start kam nehi kar raha hai.....
Kaise iska problem solve kare please suggest...
Software ki problem h ek baar battery ka + wala wire hta kr 2 min baad lgana ho skta h ho jaye nhi to change hi hoga
@@RajeshElectrical Sir aisa kuch nehi ho sakta ki display ko sleep mode me nehi jane denga tooo
Display all time on rakh na chahte hai
Sir 180 kva me 121n.falt hai help me
Kon si company ka h DG or uska controller
@@RajeshElectrical powarica 180kva
Sir 180 kVA me 1317 fault code aa Raha hai
Sudheer sar 180 me121 no ka halt hai please help me
What is password for AVR disable setting..
Yah controller mere ko chahie milega
38000 + gst + transport
Generator display on hone ka bad aapne bataya hai hat ka nishaan ko press kiya hai lekin generator start nahi horahai
Self pr clamp Meter lga kr rkho hath ka nisan aane pr button dbao or clamp Meter me voltage check kro ager aa rhi h to self or uski coil ko check kro
@@RajeshElectrical sir kal aapne bataya self starter Direct karnese start horahai (South Sudan) msg kiya sir
DG start ho jata h 10 se 15 second me power command me installing aata h or DG band ho jata h
Stop solenoid ka lever hta do or check kro
Sir millage kitni deti hai
10.2 LPH on 25% load and 36.4 LPH on 100% load
@@RajeshElectrical sir 50hp ka load hai to kaunsa genretor le pls reply kitna kva ka Mai confused hun
1845 error
2545 error
Error V12
सर, hz 1448 आ रहा है स्क्रीन पर क्या दिक्कत हो सकती है, ओर इसे कैसे सही करें ।
DG ki fuel line nozzle ko check kro
Bhai engine k fuel line ko check kro
@@RajeshElectrical धन्यवाद जी🙏🏻
197 fault aarhe h
English please
Solined valve on nahin ho rhaa
Solenoid ki coil pr voltage check kro
@@RajeshElectrical 9voltage atty hain phir hold nain hote hath se chaloo to 12 poray ho jatyy hain
Valve ki coil change kr k dekho
@@RajeshElectricaldosray generator se coil khol kar lagie hai phir bhe hold Nahi ho rehee
Dg manual not start
Same problem
Как на русский перевести?
Only Hindi n English
I HAVE SENT YOU AN E-MAIL. PLS. CHECK AND REPLY
Ok sir
सर ढाई सौ केवीए का जनरेटर जो स्टार्ट ही नहीं हो रहा है
डायरेक्ट स्टार्ट करना पड़ रहा है सर
@@manoharlalbansiwal7969 display Panel se nhi ho rha kya ek choti relay hogi wo check kro aap
Sir ji aapka phone No, mil skta h
Kya puchna h
@@RajeshElectrical 250kva dj h sflai km aa rhi h
Rpm check kro
Exiting voltage check kro
Fuel pump check kro
@@RajeshElectrical rpm 1800tk jata h sir
HMI 211 sleep mode mai nahi ja rha