Connection Wednesdays - Focus on buckling

แชร์
ฝัง
  • เผยแพร่เมื่อ 30 ม.ค. 2025

ความคิดเห็น • 11

  • @raadhadi5655
    @raadhadi5655 5 ปีที่แล้ว +2

    it's useful presentation about buckling thanks for all team and we need more information about program in future and I hope present free live video about capacity design / seismic resistance

    • @ideastatica_en
      @ideastatica_en  3 ปีที่แล้ว

      Hello, we will make such webinar in the future

  • @stooncol619
    @stooncol619 4 ปีที่แล้ว

    i am using version 10.1 , where there is GNA option does turning this option on is enough to have a satisfactory design ? for thin walled sections

    • @ideastatica_en
      @ideastatica_en  3 ปีที่แล้ว +1

      Hello, all the settings can be found in the Code setup. Ror thin walled section, be aware of our slide in the video: th-cam.com/video/8orM2XWjAgM/w-d-xo.html

  • @guillemmartinez3555
    @guillemmartinez3555 2 ปีที่แล้ว

    Is it possible to download the presentations in pdf format of the webinars?

    • @ideastatica_en
      @ideastatica_en  2 ปีที่แล้ว

      Hello Guillem, usually we do not provide presentations after the webinar, as the recording should be more suitable. But feel free to download specifically this one here: www.slideshare.net/secret/L7Tbvboen7Z8WS

  • @gilARENASbert
    @gilARENASbert 3 ปีที่แล้ว

    When I was attending the IDEA Statica course at Construsoft Spain, they told us that ALPHAcrit should be no more than 4 refering to EN1993-1-5 Annex B.1 and some partial security factor. And that includes main bearing members too

    • @ideastatica_en
      @ideastatica_en  3 ปีที่แล้ว +1

      Please see following: www.ideastatica.com/support-center/buckling-analysis

  • @efcables418
    @efcables418 4 ปีที่แล้ว +2

    Hello,
    When you say that for alphaCrit

    • @ideastatica_en
      @ideastatica_en  3 ปีที่แล้ว

      Hello, you are right, the correct answer is when < 15, you have to do more checks

  • @offshare2033
    @offshare2033 ปีที่แล้ว

    Thanks