Thank you sir, Mera ye heat convector bachpan se fault tha isme, double coil pe chalao to trip hojata tha jaldi se aur fir patanahi kab tak hum sardi me thithurte rehte the jab tak wapis coil connect hoke on nahi hota tha heater. mere same model lagbhag 20 years purana tha, rust wagera saaf kia, paint kia wires badli and chaka chak hogaya mera heater. Thank you so much sir.
Dear Ashoka ji, mere pass same model hai Usha fan heater ka, lekin bahut saal use karne ke baad ab uski wiring kharab ho gayi hai aur iske thromostate & on off switch bhi kaharab ho gaye hain, meine local electrician ko dikhaya tha but sabhi ne isko repair karne se mana kar diya, plz help in this urgently
Sir aagar rotary thermostat aur elements ke uppar wala Dono thermostat badal deya hai phir bhi cut off nahi ho raaha hai to kya kare phele bahut jaldi jaldi cut off ho raaha tha aab kitne deer mei cuttoff hoga single elements pe batyee
Bhai ji ye heater bar bar trip kr rha h jab 2000 Watt pe chalate hai to. N new aya tha tab nahi ho rha tha aisa. So kya aap bta sakte h ki aisa kyu ho rha h
Accidentally setting disturbed. It stops after a few seconds automatically and restarts. I followed people's guidance but in vain. Nobody guide correctly. Please reply à d help
Mere usha heater ki thermal switch kharab ho gai hai. Kya ise repair kiya ja sakta hai. Yadi badalna ho tab kahna se mil payegi. Heater kam kar raha hai.
Vaise to aap sabhi conection ko check kijiye ki koi body ko tuch to nahi kar raha hai, iske alava aap heter ke samne se heating elemant ko dekhiye ki vo kahi se latak to nahi raha hai, kai case me elemant heat hokar thoda dhila hokar latak jata hai or metal fram tuch kar jata hai,
You have not shown the main thing.... How to change the heating element? You have only shown how to identify the problem. Identifying the problem anyone can do ......
Jab ham heater ko double element(2000 watt) pe chalate hai to bar bar ye thermostat cut ho jata hai iska kya solution hai PLZZ jaldi reply de bahut thand hai 🥶🥶
Sir Iske blade to spair Milne mushkil hai... Ak option ye hai ki aap usha care par call Karo to vo shayad provide Kara de..care ka no. Aap Google par search kar sakte hain Vaise mere paas ye hai. 01244205466.
Sir jab double heater chalte hai to heater 1minute bad hi band ho Jata hai for 5 minute ke band start hota hai fir 1 minutes ke band ho Jata single heater me ko problem Nahi hai
@@ashokatech Kya iski plastic body mil sakti hai ? mera heater girne se break ho gaya hai. metal part aur internal part sab sahi hai. bas plastic break ho gaya hai.
Mera heater two setting pr 30 second me off ho jata hai fr ek do mnt bad chalta hai fan bhi acha chal rah hai koi problm ni hia kaise aolve kre ye issue
Switch me problem hai.. Ak wire ka tukada leke.. Ak sira switch ke comman point par tauch Karo Dusra sira heater ya fan ke connection par tuch Kare or dekhe ki vo chala ya nahi.. Agr chalta hai to switch Change Kare...
@@ashokatech chal raha hai bas maine cleaning ke liye fan khola uske bad blade kuch disturb hui sayed uske baad se air to badiya de raha hai but heater ke uper jo cutout hai wo 1 minut me cut kar de raha hai
आप एक बार हिट चेक कीजिए कट होने से पहले ही बहुत ज्यादा देता है यह नॉर्मल हिट पर भी वह कट हो जाता है अगर वह नॉर्मल हीट पर भी कट हो जाता है तो थर्मिस्टर की पत्ती को आप थोड़ा सा मोड़ के हार्ड कर सकते हैं
लेकिन हीटर बहुत ज्यादा हिट दे रहा है और उससे अगर धर्म मित्र काट होता है तो उसके इसमें आप मत मोड़ना फिर आप एयर फ्लो चेक करो फिर एयर फ्लो कम होने की वजह से भी ऐसा कई बार होता है अगर पंखे की ब्लड अगर डिस्टर्ब हो गई है तो पूरी हवा नहीं आ रही होगी जिसकी वजह से ऐसा हो रहा है
Thankyou bhaiyya. Aapne bhadiya video banaya. Yetho first aid jaisa kaam ayega.😊
बहुत बहुत धन्यवाद आपका वीडियो देख कर मै अपना रूम हीटर रिपेरिंग खुद से कर लिया ❤
Thanks bro
Itna hi kafi h mere liye mai sb samajh gya or mera 10 second me on off jo hota tha wo v maine thik kr lia
Good
sr, mra heater k spring hot ho jata h bhut jisse thermostate hr kuch sec.m usko cut kr deta h heatng isko kese kre
Kaise thik kiya ??
bhai bahut shukriya.
mene bhi yahi steps follow kiye hai.
now my heater is working superb
Worked, saved money, thank you
Most welcome Shiraz ji ♥️
Very nice information 👍👍👍
Thank you so much sir 🙂
Thank you sir, Mera ye heat convector bachpan se fault tha isme, double coil pe chalao to trip hojata tha jaldi se aur fir patanahi kab tak hum sardi me thithurte rehte the jab tak wapis coil connect hoke on nahi hota tha heater. mere same model lagbhag 20 years purana tha, rust wagera saaf kia, paint kia wires badli and chaka chak hogaya mera heater. Thank you so much sir.
Good information. Thanks
Thanks Brother for sharing knowledge
🌹🙏🏻🙏🏻🌹
Hame de dijiye
Sir kya iska elements market mai available hai.
spark with tik tik sound in thermistat above heating coil...pl suggest solution
Mere pss v h 24 hrs chalti h ☺️😚
Kya es ko direct kar ke use kar sakte hai.
Thanks 👍👍👍
Thank you so much Monit ji 🙂
For direct chat follow me on instagram..
instagram.com/ashoka.tech
Bhai aap macenik se badhkar ho
Good job
Thank you so much dear 🙂
Sir, मेरे उषा हीटर में कोई current नहीं आ रहा है, कृपया lcoil की wiring ज़मझाएं। धन्यवाद।
❤
Jarur sir
Good job done by you
Thank you anju ji
Bahut hi badhiya
Thank you
The machine getting cut our every 5-6 minutes. Please help.
Because of overvheat don’t cover heater fully
Thermal cutout ko bypass krna btaiye
Sir,
My heater cut off again and again
Sir Kal video daal raha hu is par 👍
@@ashokatech Bhai kya hua meri problem solve nhi ki aapne
@@ashokatech kab dalo ge video bhai ?
Iska heating element kaise replace kar sakte Hain, ye bhi bataiye
Nice work brother.
Thank you Dear 🙂
Sir plz yeh batado ki coil me 3 connections hoti he iss me common koun he
Aur dosra sawal yeh dial switch kese connect karte he
Same question
Thankyou ser imade my heator
good information
Thank you irfan bhai
Double dot setting pr bar bar cut off ho jata hain
Dear kal is par video bana ke dalta hu 👍
@@ashokatech Bhai double dot setting pr bar bar cut off ki problem solve karo please
Fan motor ka type aur kahan milegi. Pl send link.
Thermostat k carbon saaf krne se ho jayega kya ye sahi n bar bar trip nahi karega?
Nahi agar baar baar trip kar raha hai to ye Karbonn ki problam nahi hai
Jab ham heater ko double element pe chalate hai to bar bar ye thermostat cut ho jata hai iska ka solution hai
@@ashokatech jab karbonn ki problem ho too kya hoga matlb kase pta chalta hai ki karbonn ki problem hai please reply
What should do for that
Esme jo motor use kiya h wo AC current prr chlta h ya DC
Ac par
Fan making a lot of sound, what are the things that I should check first?
Dear Ashoka ji, mere pass same model hai Usha fan heater ka, lekin bahut saal use karne ke baad ab uski wiring kharab ho gayi hai aur iske thromostate & on off switch bhi kaharab ho gaye hain, meine local electrician ko dikhaya tha but sabhi ne isko repair karne se mana kar diya, plz help in this urgently
Where I will get side grill
👍🏻 usefull
Iske side ka body parts kaha milega jo plastic ka hai
Thinks bhai
Your most welcome Shahbaz Bhai 🙂
Bhai mera usha 812t heater ka blower work nahi kar raha hai.. New hai amazon se mangaya tha.. Pls help..
Sir aagar rotary thermostat aur elements ke uppar wala Dono thermostat badal deya hai phir bhi cut off nahi ho raaha hai to kya kare phele bahut jaldi jaldi cut off ho raaha tha aab kitne deer mei cuttoff hoga single elements pe batyee
Bhai ji ye heater bar bar trip kr rha h jab 2000 Watt pe chalate hai to. N new aya tha tab nahi ho rha tha aisa. So kya aap bta sakte h ki aisa kyu ho rha h
Sir iska thurmostat set karna padega main is par ak video banata hu 👍
Sir fan nhi chal rha kaise check or theak karen
Mere wala cutoff bhut jaldi marta hai
10 second on rehta hai 10 second off
Is se ye full efficiency pe nahi chal pa rha
mera bi bro koi solution iska?
Change your thermostat
Last yr maine iske heating element change krwaya tha.... But yeh ab pehle jitna heat nhi hota.... Jab se iska heating element change hua tha
Accidentally setting disturbed. It stops after a few seconds automatically and restarts. I followed people's guidance but in vain. Nobody guide correctly. Please reply à d help
Please watch this video.th-cam.com/video/PGW2gqr8hqo/w-d-xo.html
थर्मो स्टेट fit करना हैं sir
Mera room heater har thodi der main auto cutoff ho rha hai bina room garam kiye ...kya mujhe thermal cutoff change karna padega ??
Bhai kal is par ak video bana ke dalta hu 👍
Autocut ho raha hai after every five minutes.. kya solution hai?
भाई 1 पॉइंट पर चला कर देखो
मेरा भी ऐसे ही कर रहा है।
लेकिन 2 पॉइंट पर।
Thanks sir
Bhai double karta hu too jaldi hi off ho jata hai only single mai chalta hai kya problem ho sakti phle theek tha please reply Bhai
Where we can find this coil
www.ashokaelectronics.in.net/Ashokaelectronics/room-heater-heating-element--size-dimension--15---17-hole--for-heaters-/7056714436?friwj3
Gud sir tnxs
Mere usha heater ki thermal switch kharab ho gai hai. Kya ise repair kiya ja sakta hai. Yadi badalna ho tab kahna se mil payegi. Heater kam kar raha hai.
Thermal cutout blue Pris kitna ha
Or market ma miltha ha
Orient room blower kaise repair kare
Sir model no. ?
sir mera blower fan speed slow h
Es k body ko tuch karne p corent lagta hai kyse sahi kare
Vaise to aap sabhi conection ko check kijiye ki koi body ko tuch to nahi kar raha hai, iske alava aap heter ke samne se heating elemant ko dekhiye ki vo kahi se latak to nahi raha hai, kai case me elemant heat hokar thoda dhila hokar latak jata hai or metal fram tuch kar jata hai,
For direct chat follow me on instagram..
instagram.com/ashoka.tech
Thanks sir
How to repair heater moter plzz reply
Bhai Iska motor kaha milega
Motar fan
You have not shown the main thing.... How to change the heating element? You have only shown how to identify the problem. Identifying the problem anyone can do ......
Ok sir i will make the next video element change, thanks for comment
In your opinion bajaj ka hetar best hi ya usha ka
Mere hisab se Usha thik hai
Jab ham heater ko double element(2000 watt) pe chalate hai to bar bar ye thermostat cut ho jata hai iska kya solution hai PLZZ jaldi reply de bahut thand hai 🥶🥶
Spring kaise khole
Sar mere Usha fh812 t company ka heater hai usko chalte chalte fan ruk jata hai Kishor video banaaiye jata hai
hello meray walay blower mein achanak indicator mein blast ho gaya aur phir chalu nahin hua...main swich bhi trip ho jaati hai chalu karnay say...kya yeh repair ho sakta hai?...please tell
Indicator ke dono wire Kat Kar on kariye on ho jayega , fir ak New indicator laga Dena
Good sir
Blower Ka switch lagaye h garam ho Raha h pr jaldi -2 trip ho ja Raha h kya itna jaldi -2 trip Hoga to garam kaise Hoga
हमारा उषा का ब्लोअर में करंट छूने पर मरता है कैसे ठीककरें
Bhai mere heater me bulb on hai aur heater fan nhi chal raha help kar dijiye
Sir maine apna blower same isi tarike se clean kiya but wo abhi bhi same pblm create kr rha hai mujhe ab kya karna chahiye 🙏
Fan blade kanga per mile gain iss heater k
Sir Iske blade to spair Milne mushkil hai... Ak option ye hai ki aap usha care par call Karo to vo shayad provide Kara de..care ka no. Aap Google par search kar sakte hain Vaise mere paas ye hai. 01244205466.
Sir jab double heater chalte hai to heater 1minute bad hi band ho Jata hai for 5 minute ke band start hota hai fir 1 minutes ke band ho Jata single heater me ko problem Nahi hai
Nice video
Mere Wale ki fan moter khrab ho gyi kitne ki miegi
थर्मल कट आउट खराब हो गया है उसकी जगह पे क्या लगाएंगे ??
Ishse acha kon SA heater Lena chaiye Kamra jaldi se garam ho jaye
👌👏👏👏
👌👌👌
Bhai kya ye full plastic body me aata hi
Nahi ye model to nahi aata, esme side jali plastic ki Hain or Baki sab metal hai, Usha Ho ya Bajaj dono same hain
@@ashokatech
Not plastic but heat resistant Bakelite
@@ashokatech Kya iski plastic body mil sakti hai ? mera heater girne se break ho gaya hai. metal part aur internal part sab sahi hai. bas plastic break ho gaya hai.
Sir mere heater me current aa rha hai kya kru
Bhai mera indicator jal rhaa bt heater nahi bt kabhi kabhi achakank chaone lagta h
Sir Iske tharmo State ko clean karo
Har 30 second me yehi wala room heater auto cut ho raha hai… kya kare? Kya problem hai?
Please help me this product 5 scend running automatically stop whate issue please reply
Mera heater two setting pr 30 second me off ho jata hai fr ek do mnt bad chalta hai fan bhi acha chal rah hai koi problm ni hia kaise aolve kre ye issue
सर मेरा हीटर उषा का है बार बार कट मार रहा है 2 मिंट बाद फिर चालू हो जता हे प्लीज हैल्प सर
Coil change karne ka tareeka bataye
How connect wire to fan
Bhai me usha heater khola abb set nhi kr para
How to repair it's fan
I'll make a video and upload it next week, thanks for comment
Bhai mere room heater ka fan ulta chal rha hai kya kru
Kuch bataya bhi h isme ya phir kholna band karna sikhya h
Verma jab technical knowledge na ho to video mat deko ab kitane badhiya se batage
What about fan noise
Mera bhi ak heter band hai bhai, usme indicater chalu hai, fan bhi nahi gumrahi hain ur hit bhi nahi ho raha hai? Q
Switch me problem hai.. Ak wire ka tukada leke.. Ak sira switch ke comman point par tauch Karo Dusra sira heater ya fan ke connection par tuch Kare or dekhe ki vo chala ya nahi.. Agr chalta hai to switch Change Kare...
Also after fitting new elements not work.
Sir 5 minute ke bada fan ki jyada awaj aa rahi hai aur vibration bhi ho raha hai kya problem ho sakti hai
Any response?
On off switch not working how to repair
I have the same heat convector, 5_6 saal ho gye hai, kal isme se burning smell k saath smoke nikla , kya problem hui hai ye
Sir fan setting gadbad ho gayi hai cutt ho ja raha hai bar bar coil heat ho ja raha hai
Ok to Kya fan nahi chal Raha ?
@@ashokatech chal raha hai bas maine cleaning ke liye fan khola uske bad blade kuch disturb hui sayed uske baad se air to badiya de raha hai but heater ke uper jo cutout hai wo 1 minut me cut kar de raha hai
आप एक बार हिट चेक कीजिए कट होने से पहले ही बहुत ज्यादा देता है यह नॉर्मल हिट पर भी वह कट हो जाता है अगर वह नॉर्मल हीट पर भी कट हो जाता है तो थर्मिस्टर की पत्ती को आप थोड़ा सा मोड़ के हार्ड कर सकते हैं
लेकिन हीटर बहुत ज्यादा हिट दे रहा है और उससे अगर धर्म मित्र काट होता है तो उसके इसमें आप मत मोड़ना फिर आप एयर फ्लो चेक करो फिर एयर फ्लो कम होने की वजह से भी ऐसा कई बार होता है अगर पंखे की ब्लड अगर डिस्टर्ब हो गई है तो पूरी हवा नहीं आ रही होगी जिसकी वजह से ऐसा हो रहा है
@@ashokatech phir fan ka blade kaise thik kare
Sir mere room garam nahi karta
Sca circuit diagram
Sorry samajh nahi aaya, please dubara puchhiye kya puchhana chahti hain aap