SAP QM Sampling Procedure , Sampling scheme

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ส.ค. 2024
  • SAP QM Sampling Procedure ,Fixed sample, 100% inspection, Percentage sample, Sampling scheme, QDV1, Sample size determination in sap

ความคิดเห็น • 45

  • @alastormoody86
    @alastormoody86 3 ปีที่แล้ว +1

    thanks so much.. You are not a friend, but a guru.. :D

  • @BegumSonmezturk
    @BegumSonmezturk ปีที่แล้ว +1

    Very helpful and clearly explained. Thank you so much.

  • @anugoyal9539
    @anugoyal9539 3 ปีที่แล้ว +1

    Very well presented. Love this channel.

  • @luigiaurilio4786
    @luigiaurilio4786 9 หลายเดือนก่อน +1

    Hi. Thanks fotrthe video.
    From yout video I see that the sample size that we see on the lot is taken from the first characteristic. May I ask what happens when I have more characteristics with dufferenr sampling schemes (example first one fixed 100%, second one fixed 90%).
    Thanks.

    • @YASHTOUCH
      @YASHTOUCH  9 หลายเดือนก่อน

      Hi, could you please mail me your exact requirement, I will provide you the solution.

  • @nomanhafeez3211
    @nomanhafeez3211 11 หลายเดือนก่อน

    Nice Video. Can you please provide me inspection type excel sheet.

  • @df5895
    @df5895 4 ปีที่แล้ว +1

    You are doing really good work

    • @YASHTOUCH
      @YASHTOUCH  4 ปีที่แล้ว

      Thank you so much......

    • @df5895
      @df5895 4 ปีที่แล้ว

      Valuation mode is grey out

    • @df5895
      @df5895 4 ปีที่แล้ว

      @@YASHTOUCH can I get your number

    • @df5895
      @df5895 4 ปีที่แล้ว

      7892125862

  • @SumitKumar-jb2vk
    @SumitKumar-jb2vk 4 ปีที่แล้ว +1

    Reduced and tightened severity only work with DMR??
    What if only normal severity is used and we are not using DMR

  • @men.nguyen
    @men.nguyen ปีที่แล้ว +1

    Hi, is there any which way that i can re assign inspection plan to an inspection lot type 01 which already made Usage Udecision?, hence i dont want created a new lot. As my research, there is no way to cancel sample (QAC3) of inspection lot with UD status.

    • @YASHTOUCH
      @YASHTOUCH  ปีที่แล้ว

      Hello,
      Could you plz send me your exact requirement with proper screenshot if possible , accordingly i will provide you solution.

  • @deepakdmanjila9969
    @deepakdmanjila9969 ปีที่แล้ว +1

    very informative

    • @YASHTOUCH
      @YASHTOUCH  ปีที่แล้ว

      Glad you think so!

  • @ALOKKUMAR880
    @ALOKKUMAR880 3 ปีที่แล้ว +1

    Thanks for the video...could you please make a video on Dynamic modification rule???

  • @dayangsofea5895
    @dayangsofea5895 3 ปีที่แล้ว +2

    I followed your steps and during the creation of inspection lot, after pressing calculate, its still inspects 100% required.

    • @YASHTOUCH
      @YASHTOUCH  3 ปีที่แล้ว

      i am not getting ur point. plz explain clearly.

    • @dayangsofea5895
      @dayangsofea5895 3 ปีที่แล้ว +1

      @@YASHTOUCH I have created the sampling scheme and also sampling procedure. However, when i try to calculate the sampling size by clicking the calculator, the sample size automatically calculate 100% inspection instead of the sample size.

    • @wanderlust26192
      @wanderlust26192 3 ปีที่แล้ว +1

      @@dayangsofea5895 I think you should check your inspection plan was assigned to Inspection lot, may be the previous Inspection plan was assigned it has sample procedure use sample type 100% inspection. You also use Tcode QAC3 for cancel sample determination has assigned to inspection lot then you can assignment new inspection plan with new sampling procedure. :)

    • @YASHTOUCH
      @YASHTOUCH  3 ปีที่แล้ว

      Thanks

  • @ravidagar3285
    @ravidagar3285 3 ปีที่แล้ว +1

    Hi, I have subscribed and liked because its really helpful. Please upload a video for calibration process
    and sample drawing.

  • @faisalhabib3794
    @faisalhabib3794 2 ปีที่แล้ว +1

    Hi very informative videos. Do you give one on one training as was interested in SAP QM ? Urgent reply will be highly appreciated

    • @YASHTOUCH
      @YASHTOUCH  2 ปีที่แล้ว

      Kindly mail me your requirement on Email id - yashrajinamdar90@gmail.com

  • @rohitnagdeve2690
    @rohitnagdeve2690 4 ปีที่แล้ว

    Nice Video. Can you elaborate more on Sampling Scheme and how C1-D1; C2-D2; ... ; Cn-Dn values work in result recording.

    • @YASHTOUCH
      @YASHTOUCH  4 ปีที่แล้ว +1

      Sure...

    • @delibatan
      @delibatan 4 ปีที่แล้ว

      Yes please!!! can you create separate video for that! :)

    • @YASHTOUCH
      @YASHTOUCH  4 ปีที่แล้ว +1

      Sure...
      Meanwhile u like ,subscribe the channel and share with your friends

  • @abcchannel2358
    @abcchannel2358 4 ปีที่แล้ว +1

    Pls share videos for Dynamic Modification rule and Sampling Drawing Procedure

    • @YASHTOUCH
      @YASHTOUCH  4 ปีที่แล้ว

      Will upload soon. Thank you

  • @mahendran8888
    @mahendran8888 4 ปีที่แล้ว +1

    I have subscribed your channel, please make video on Dynamic modification rule

    • @YASHTOUCH
      @YASHTOUCH  4 ปีที่แล้ว

      Thanks .sure I will make videos on all QM topics .

  • @VGTECHTRICKS
    @VGTECHTRICKS 3 ปีที่แล้ว +1

    please make video on dynamic modification rule

  • @SumitKumar-jb2vk
    @SumitKumar-jb2vk 4 ปีที่แล้ว +1

    Can you please explain , Dynamic modification rule???

    • @YASHTOUCH
      @YASHTOUCH  4 ปีที่แล้ว

      Sure,I will upload all PP QM videos periodically .meanwhile you like,subscribe the channel and share with friends.