Smoke Detector Spacing & Designing Explanation | Area Coverage | Imp Interview Question | Ansari29

แชร์
ฝัง
  • เผยแพร่เมื่อ 12 ก.ย. 2024
  • Smoke Detector Spacing & Designing Explanation | Area Coverage | Imp Interview Question | Ansari29
    In this video, you can learn what is smoke detector spacing in different area & location.This video is important for project & service engineer who is working in fire & safety industry. This video is also useful for those person who are working in facility & operation industry.
    If you are first time watch my channel so I request you to please first visit my channel videos & if you like my videos then only subscribe to my channel & also write comments if you want such valuable information.
    __________________________________________________________________________
    You can also join us on our facebook page, link available below.
    / ansari2991
    ---Interview Question & Answer On Fire Suppression System | Part-3 | FM200 | NOVEC | By Ansari29
    • Interview Question & A...
    ---Interview Question & Answer in Fire Alarm System | Part-2 | By Ansari29
    • Interview Question & A...
    ---Interview Question & Answer in Fire Alarm System | Part-1 | By Ansari29
    • Interview Question & A...
    ---Faults & Troubleshooting in Addressable Fire Alarm System | Types of Faults | In Hindi | By Ansari29
    • Faults & Troubleshooti...
    ___________________________________________________________________________
    fire alarm system design training,fire alarm system design guide,fire alarm system design tutorial,fire alarm system design course,fire alarm installation training,fire alarm installation training as per nfpa,fire system installation,fire alarm installation guide, troubleshooting ground fault fire alarm system,how to troubleshoot fire alarm system,conventional fire alarm system,detector fault troubleshooting,troubleshooting,fire alarm system fault troubleshooting,fire alarm system installation,fire alarm system testing,fire alarm system fault,fire alarm system commissioning,fire alarm system working principle,fire alarm testing,battery fault,open circuit fault,device missing,short circuit fault
    fire alarm panel,conventional fire alarm system,designing of fire alarm system in hindi,conventional fire alarm system in hindi,fault & troubleshooting in fire alarm system,फायर अलार्म सिस्टम में दोष और समस्या निवारण,open circuit fault in fire alarm system,battery fault in fire alarm system,AC supply fault in fire alarm system,fire,smoke detector,MCP,heat detector,troubleshooting,fault,addressable fire alarm system wiring,addressable fire alarm system installation,addressable fire alarm system installation in hindi,addressable fire alarm system tutorial,addressable fire alarm advantages,addressable fire alarm system cabling,addressable fire alarm system diagram,fire alarm addressable system wiring diagram,addressable fire alarm system explained,how addressable fire alarm system works,addressable fire alarm system loop,fire alarm system addressable type,addressable fire alarm system wiring,
    addressable fire alarm system installation,
    addressable fire alarm system installation in hindi,
    addressable fire alarm system programming,
    addressable fire alarm system in tamil,
    addressable fire alarm system tutorial,
    addressable fire alarm system vs conventional,
    addressable fire alarm system manufacturers in india,
    addressable fire alarm system advantages,
    addressable fire alarm system boq,
    bosch addressable fire alarm system,
    addressable fire alarm system communication protocol,
    addressable fire alarm system components,
    addressable fire alarm system cabling,
    conventional and addressable fire alarm system,
    conventional vs addressable fire alarm system,
    addressable fire alarm system diagram,
    addressable fire alarm system design,
    fire alarm addressable system wiring diagram,
    addressable fire alarm panel,
    addressable fire alarm system explained,
    addressable fire alarm system honeywell,
    how addressable fire alarm system works,
    honeywell addressable fire alarm system wiring diagram,
    addressable fire alarm system india,
    addressable fire alarm system installation guide,
    addressable fire alarm system loop,
    addressable fire alarm system manufacturers,
    wiring of addressable fire alarm system,
    addressable fire alarm system ppt,
    addressable fire alarm system protocol,
    addressable panel fire alarm system,
    ravel addressable fire alarm system installation,
    addressable fire alarm system specification,
    addressable fire alarm system siemens,
    semi addressable fire alarm system,
    fire alarm system addressable type,
    addressable fire alarm system working principle,
    addressable fire alarm system wiring diagram,
    addressable fire alarm system zones,
    zeta addressable fire alarm system
    -----------------------------------------------------------------------------------------------------------------------
    #Smokedetectordistance
    #Firealarmsystem
    #Smokedetector designing

ความคิดเห็น • 61

  • @ShohelShaikh92
    @ShohelShaikh92 ปีที่แล้ว +1

    Great video.... but you where refering the BS5839 not NFPA 72. As per NFPA 72 distance between 2 detectors is 9.1mtr, & covergae area will be list space x distance between 2 detectors (0.7 x 9.1)mtr. For heat detector list space will be vary as per the height of the room. The heat detector will be installed from 3mtr to 9mtr.

  • @bharatindia1289
    @bharatindia1289 2 ปีที่แล้ว +1

    Thanks bro for sharing & caring others...Dil se aapka bohath bohath shukriiya 💐💐💐💐👍🙏

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      Most Wellcome brother. This type of comments motivated me... Pls share my videos in your company group

  • @GPGroup449
    @GPGroup449 2 ปีที่แล้ว +1

    Thanks sir Ap Bahut ache se samjhate hai

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      Thanks for your comments😊 pls share my videos in your company group

  • @amirthakannan3845
    @amirthakannan3845 ปีที่แล้ว +2

    Very clear explanation..... thanks sir

  • @abubakarasim9820
    @abubakarasim9820 2 ปีที่แล้ว +1

    Very nice 👍👍👍👍

  • @timjhone1783
    @timjhone1783 2 ปีที่แล้ว +1

    Thanks, pls upload more video

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      Yes Sure.... Pls share my videos in your company group

  • @muhamadasim8673
    @muhamadasim8673 6 หลายเดือนก่อน

    Salam, bro question, ceiling void detector should be on the ceiling or we can install any where under the false ceiling

  • @vaibhavhcst
    @vaibhavhcst ปีที่แล้ว +1

    Great 👍

  • @vaibhavupadhyay4862
    @vaibhavupadhyay4862 2 ปีที่แล้ว +1

    Hello Sir, Kindly make Video on all types Beam detectors his working and connection 🙏🙏

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว +1

      Yes Sure

  • @roshan2940
    @roshan2940 2 ปีที่แล้ว +1

    Thanks Ansari sir... Pls make video on PA system.

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      Yes Sure

    • @roshan2940
      @roshan2940 2 ปีที่แล้ว

      @@Ansari29 yes sir. It would be good if you make videos on PA system. I have understood fire system with your support ❤️❤️❤️

  • @saraz06a0222
    @saraz06a0222 ปีที่แล้ว

    Very Good video.. But i think There is a mistake in no.of detectors for 500Sqmtr room
    for 112 Sqm we need 4 detector then then for 500 Sqm we need 20 Devices
    please tell me if am wrong.

  • @alihusenansari9661
    @alihusenansari9661 2 ปีที่แล้ว +1

    Please make a video riser module..

  • @kaambolo786
    @kaambolo786 6 หลายเดือนก่อน

    You have not mentioned the height in this video. Please also mention the height

  • @muffledvoice94
    @muffledvoice94 ปีที่แล้ว

    Beem k upar detector install kr skte hain kya?

  • @imranmahmood3003
    @imranmahmood3003 2 ปีที่แล้ว +1

    If our roof height is 30ft. Then how we install? Smoke and Heat detector
    Can change the rules or distance between detector? Plz

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      I will make video on different hight

  • @siddharthsvideo
    @siddharthsvideo 2 ปีที่แล้ว +1

    Pls make video on HYDROGEN SENSOR which used in battery room

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      Ok, I will try to make video on said topic

  • @rajvaghela4384
    @rajvaghela4384 ปีที่แล้ว

    how come distance between two detector be 14.1 in case of corridor and in second example it is 15 mtr can you please explain sir

  • @alaminmahmud7788
    @alaminmahmud7788 ปีที่แล้ว +1

    Sir,Does this system apply to bosch detector?

    • @Ansari29
      @Ansari29  ปีที่แล้ว

      It is standard

  • @pradhvivlogs
    @pradhvivlogs 5 หลายเดือนก่อน +1

    Detector continue blinking what solution

    • @Ansari29
      @Ansari29  5 หลายเดือนก่อน

      It's normal. If blinking. If countinue ON then it's an alarm

  • @Itself686
    @Itself686 2 ปีที่แล้ว +1

    when connecting Ac power 220v in notifier 320e panel ,the AC power fuse damaging again and again.
    Tell me what is the exact problem???

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      1. Check proper connection & use lugs instead of direct connecting cable.
      2. Prefer UPS power supply if available.
      3. Check supply cable, it may be damage internally or direct change the cable.
      4. Use 1.5 sq mm cable
      5. Check earthing value it should not be more than 0.5 V

  • @mdabdulla237
    @mdabdulla237 2 ปีที่แล้ว

    Sir,
    ये information किस standard से लिया गया है ??
    इसको भी share करेंगे तो और भी अच्छा होगा इंटरव्यू के लिए ।
    Thank you 🙏🙏🙏
    E.g NFPA or any other ??

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      As per NFPA..

    • @mdabdulla237
      @mdabdulla237 2 ปีที่แล้ว

      @@Ansari29 Thank you Sir.

  • @rbilalahmad
    @rbilalahmad 2 ปีที่แล้ว +1

    Morley las KY mcp addressable or sounder addressable madeul singal loop inputs

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      Pls check my videos list

  • @ajaycapricon5
    @ajaycapricon5 ปีที่แล้ว

    Please share the codal reference for smoke detector installation

  • @suresharigela3703
    @suresharigela3703 2 ปีที่แล้ว

    Preaction dilauge valw barume one vedio karo bay

  • @goswamivijay
    @goswamivijay 2 ปีที่แล้ว +1

    Sir please refer indian standard IS-2189 it's 7.5 MTR not 10.5 myr for smoke detector

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว +1

      Yes, I will make video as per IS

  • @RohitGupta-qi4cy
    @RohitGupta-qi4cy 2 ปีที่แล้ว +1

    Sir,
    1.Mere yaha detector mai 30-33v ki supply aa rahi hai.
    2.or sir detector activate hai,blink nahi kar rahe hai.
    3.sir adress ke hisaab se kese pata Kare detector ki location.
    Thank you.

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว +1

      1. 24 V DC aata hai
      2. Normal condition m blink hota hai..
      3. Address k sath location likha hota hai

    • @RohitGupta-qi4cy
      @RohitGupta-qi4cy 2 ปีที่แล้ว

      Address k saath location ka pta kaise chalega

    • @RohitGupta-qi4cy
      @RohitGupta-qi4cy 2 ปีที่แล้ว

      System/CPU fault kaise thik kare???
      Ispar sir ek video bna do please.
      Thank you

  • @RahulSingh-hn6sn
    @RahulSingh-hn6sn 2 ปีที่แล้ว +1

    5.3×5,3ko jab multiply karoge to 112 kaise aayega,,

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      Apologize for the same.. It's 10.6 x 10.6 become aprox 112 sqmm....
      I will make corrections in next video m

  • @krishna-lr2vk
    @krishna-lr2vk ปีที่แล้ว +2

    5.3x5.3 = ?

    • @Ansari29
      @Ansari29  ปีที่แล้ว

      It's an error I will upload once again. With proper correction.

  • @dawoodsiddiqi2772
    @dawoodsiddiqi2772 ปีที่แล้ว

    the units should be feet not meter

  • @imransaifisaifi3190
    @imransaifisaifi3190 2 ปีที่แล้ว +1

    Please sar aapse baat kar ni he

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      Pls share your doubts on ansari2991@gmail.com

  • @imransaifisaifi3190
    @imransaifisaifi3190 2 ปีที่แล้ว +1

    Sar aapse baat kar ni he

    • @Ansari29
      @Ansari29  2 ปีที่แล้ว

      Send ur query to ansari2991@gmail.com

  • @JitendraKumar-ie8cn
    @JitendraKumar-ie8cn 2 ปีที่แล้ว

    But I am using siplex detector right now that range is five MTR only

  • @frankrobinson2400
    @frankrobinson2400 2 ปีที่แล้ว

    ᑭᖇOᗰOᔕᗰ 👏