Intergas Service/fault finding

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ธ.ค. 2024

ความคิดเห็น • 74

  • @protectkravmagawirral6686
    @protectkravmagawirral6686 3 ปีที่แล้ว +4

    Great video and very clear. I love these intergas boilers.

  • @rayc1503
    @rayc1503 5 ปีที่แล้ว +1

    Brilliant Jono I don't have much knowledge on intergas boilers. Serviced 2 changed a faulty fan but never installed any. I know they're expensive when they go wrong. Over £200 for a fan 😳 customer wasn't too happy when I told them what the repair was going to cost. Suppose the good thing is you can leave a customer with hot water if you're working on the central heating side.
    Great stuff as always pal 🤗

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว

      Always for asking g buddy

    • @protectkravmagawirral6686
      @protectkravmagawirral6686 3 ปีที่แล้ว +1

      Most manufacturers charge for the back end. I just fitted a worcester bosch fan costing £225.

  • @gasmanrus
    @gasmanrus 2 หลายเดือนก่อน

    Fantastic video 👌🏻👌🏻👌🏻

  • @paulrossiter9567
    @paulrossiter9567 3 ปีที่แล้ว +1

    Nice explanation Ja 👏🏻👏🏻👏🏻

  • @johnburns4017
    @johnburns4017 7 หลายเดือนก่อน

    Is the burner failure common on Intergas boilers? I know they have a slightly amended design as the burners now have a new part number.

    • @warriorsofwarmth
      @warriorsofwarmth  7 หลายเดือนก่อน +1

      The burner seal has been up graded

    • @johnburns4017
      @johnburns4017 7 หลายเดือนก่อน

      @@warriorsofwarmth
      Thx. I am aware of that from red to black in colour. But the burner now has a new part number. Are you saying there is no change with the burner, being the same old early failure job?

  • @nameless5821
    @nameless5821 4 ปีที่แล้ว +1

    whats the grease youre putting on?
    thanks for the vids

  • @kamilkoscielniak7741
    @kamilkoscielniak7741 4 ปีที่แล้ว +1

    Rapid 25 combi
    Heating working fine
    Hot water on control coming no 3-4 fire up then 7 and no hot water ? Any thoughts?

  • @paulkendrick
    @paulkendrick 4 ปีที่แล้ว

    Hi wonder if you could help me i have a inter gas combi boiler that's making a droning sound when the boiler is not been used i.e. no heating on or hot water drawn it displays a code that reads ( con 7 ) . I've looked on the net and cant find anything would be very grateful for any help or advise thanks

  • @bhataamjad4074
    @bhataamjad4074 4 ปีที่แล้ว

    Hi jay Wht is erorr 6 showing and how is the ringing that erorr plZ

  • @discobiscuits5564
    @discobiscuits5564 5 ปีที่แล้ว +1

    Fitted the hre system a few times and the xclusive combi, seem really good, don’t really like the flue system similar to ideal, anyways great video thanks

    • @warriorsofwarmth
      @warriorsofwarmth  5 ปีที่แล้ว

      DiscoBiscuits thanks for the feedback

    • @johnburns4017
      @johnburns4017 4 ปีที่แล้ว

      I do believe they use the same flue supplier.

  • @johnburns4017
    @johnburns4017 3 ปีที่แล้ว

    What about ignition electrode. These tend to give trouble after a while in all boilers? How is it cleaned?

    • @warriorsofwarmth
      @warriorsofwarmth  3 ปีที่แล้ว +1

      Electrodes can be faulty even when looking like new

  • @johnburns4017
    @johnburns4017 4 ปีที่แล้ว

    1:08 If the burner has gone too badly? What does that mean? Nice vid BTW.

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว +1

      Sorry rushed vid, if the burner stretches or badly worn explosive ignition can happen

  • @motormusic1
    @motormusic1 4 ปีที่แล้ว

    Are these boilers any good?

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว

      Ok, good flow rate, must get them serviced regularly though

  • @konradbidwell8363
    @konradbidwell8363 2 ปีที่แล้ว

    Never seen intergas before Monday had fault code 11 indicating S1 sensor changed this boiler worked. Customer called today to say fault back again. There is no scale reducer on cold supply but does have magnaclean. How likely is it to be a block H E or possibly the HW flow switch? Something simple🤷🏼‍♂️.

    • @warriorsofwarmth
      @warriorsofwarmth  2 ปีที่แล้ว

      Chances are it’s blocked these have copper hex

    • @konradbidwell8363
      @konradbidwell8363 2 ปีที่แล้ว

      @@warriorsofwarmth could it be the aqua sensor?

  • @johnburns4017
    @johnburns4017 4 ปีที่แล้ว

    If the aqua-sensor is not working, put in pre-heat?

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว

      The pre heat, heats the hex ready for demand,

    • @johnburns4017
      @johnburns4017 4 ปีที่แล้ว

      @@warriorsofwarmth
      What will that do, if the aqua sensor is not working?

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว

      John Burns it will constantly heat the hex. How old is ur intergas?

    • @johnburns4017
      @johnburns4017 4 ปีที่แล้ว

      @@warriorsofwarmth
      I know it will heat the heat X. I fail to see how doing that rectifies a faulty aqua sensor.

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว +1

      John Burns it’s doesn’t rectify the problem it only provides a temporary fix

  • @mmack3286
    @mmack3286 5 ปีที่แล้ว

    Hi, installed a Intergas 30 system boiler but fault code 11?

    • @warriorsofwarmth
      @warriorsofwarmth  5 ปีที่แล้ว

      m Mack sensor fault try changing the NTC

    • @mmack3286
      @mmack3286 5 ปีที่แล้ว

      Hi jay, the boiler is brand new.... strange.

    • @mmack3286
      @mmack3286 5 ปีที่แล้ว

      Also it's a heat only boiler so I still need to change the parameters for a system boiler? Or should it be factory set?

    • @warriorsofwarmth
      @warriorsofwarmth  5 ปีที่แล้ว

      m Mack did u buy it as a heat only?

    • @mmack3286
      @mmack3286 5 ปีที่แล้ว

      Bought it as a Intergas 30sb

  • @helenchiu7613
    @helenchiu7613 4 ปีที่แล้ว

    I have 2015 three intergas boilers 24/28, when we used hot water, they show a faulty code 11. ( let’s say Boiler A )
    I checked code 11 means that the aqua censor isn’t working.
    To test it, I swapped this faulty aqua censor with the one on a working boiler ( boiler B) .
    Strange thing is now both boilers stopped working and both showed faulty code of 11.
    To ascertain the problem, I put an aqua censor I bought from eBay in boiler B, it’s working now.
    I am wondering what could be the problem. Please help.

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว

      Yes they get dirty and block

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว

      Also u may have paddle type they r known for seizing,

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว

      I cover Coventry if you ever want to meet

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว

      I also do free training sessions from home

    • @helenchiu7613
      @helenchiu7613 4 ปีที่แล้ว

      Thank you so much. It would be good if we can do the servicing and repair for us. How do we contact you ? What’s your email?

  • @johnburns4017
    @johnburns4017 2 ปีที่แล้ว

    Came across an installer who said he came across an Intergas Rapid 32 that has explosive ignition when igniting on CH, but never on DHW. I can only conclude it is a setting(s) in the parameters. Anyone ever come across this?

    • @warriorsofwarmth
      @warriorsofwarmth  2 ปีที่แล้ว

      The burners mesh needs replaced

    • @johnburns4017
      @johnburns4017 2 ปีที่แล้ว

      @@warriorsofwarmth
      Why only explosive ignition on CH and not DHW? That is the odd part of it. If the mesh has gone it would happen in both modes.
      The ignition is more of a _bumf_ than explosive.

    • @johnburns4017
      @johnburns4017 2 ปีที่แล้ว

      @@warriorsofwarmth
      I am not 100% convinced the burner is the problem, as he says it only gives low audible _bumf_ on CH ignition not DHW. No need to have an expensive needless burner change if not needed if the problem can be solved elsewhere - no need to get into the all too common just change parts until the problem is sorted.
      Parameter *F* is the CH starting speed. You can adjust this to start the burner at a high kW which may immediately modulate down, or start on low kW and immediately modulate up. I suggested he turns parameter *F* up by 10% at a time to see if the _bumf_ on CH ignition is eliminated. DHW starts at a high kW demand as the demand for high kW is there to heat the incoming cold water, while that is not the case on in CH mode most of the time.
      Also in some districts the gas distribution supply pressure at peak times is less than needed, which can at times give ignition problems. I have seen that before, when many parts were needlessly changed. Or the gas mains pressure may have fluctuated for a while as works are being done to it, which again causes temporary ignition problems.
      Intergas boilers want 20 Mbar at the gas valve in working pressure, so this has to be correct as well. I know some guys who will adjust the meter regulator to get that 20 Mbar at the gas valve, saying screw the gas transport provider as they have a customer to satisfy, not having all the time in the world to deal with those people which takes eons.

  • @greenleafheating75
    @greenleafheating75 2 ปีที่แล้ว

    I have install intergas eco rf
    A lot of problems
    Intergas warranty go there 4 times
    Still no problem fixed
    And no hot water
    Really bad repair service
    I have no hot water
    On the tap it is 12l / minute constant flow
    They refuse to repair
    They want an video proof send over after they attempt to repair 4 days ago
    They replace the flow sensor as a good will?

    • @warriorsofwarmth
      @warriorsofwarmth  2 ปีที่แล้ว

      Flow sensor may of been jammed

    • @greenleafheating75
      @greenleafheating75 2 ปีที่แล้ว

      @@warriorsofwarmth we have the same problem 4 days ago
      Engineer from intergas replace the senzor on Monday and on Saturday same problem

  • @RosettaStonerd
    @RosettaStonerd 4 ปีที่แล้ว

    my hr3 shows error code 0.3 - constantly blinking, anyone?

    • @Mm-lt4so
      @Mm-lt4so 4 ปีที่แล้ว

      fill up the system to 1,9-2,0 bleed the air out and it should be fine. when the pressure in the system hits the 1.0 the 0.3 blinking will disappear. turn of your heater/boiler with the on off, the boiler should say if its an intergas. ( 0.3 - ) on the display. dont forget to turn in back on. its on when you see an green light on the left side of the display. goodluck!

  • @dzmalekvali1110
    @dzmalekvali1110 4 ปีที่แล้ว +1

    Good, but talk slower no mumbling pls

  • @johnburns4017
    @johnburns4017 4 ปีที่แล้ว +1

    I am not being nasty. I could hardly understand what you were saying. You speak too fast as well. Even after replaying a number of times I could not understand some of the words. :(

    • @warriorsofwarmth
      @warriorsofwarmth  4 ปีที่แล้ว +1

      John Burns yes please forgive me, I was rushing

  • @petersutton3054
    @petersutton3054 5 ปีที่แล้ว +1

    Don't like them boilers ugly looking and bulky.

    • @warriorsofwarmth
      @warriorsofwarmth  5 ปีที่แล้ว

      Peter sutton heavy

    • @spencerwilton5831
      @spencerwilton5831 4 ปีที่แล้ว +2

      Peter sutton Who cares? Stick it in a garage or a cupboard. Much easier to work on than some tiny shoebox thing which has to be dismantled just to get to basic parts.

    • @johnburns4017
      @johnburns4017 7 หลายเดือนก่อน

      They are built like tanks.