جتنی انفارمیشن اسامہ بھائی دیتے ہیں اتنی انفارمیشن کوئی بھی نہیں دیتا ماشاء اللہ اللہ پاک سلامت رکھے آپ کو آن لائن بہت سے لوگ فراڈ کرتے ہیں لیکن اسامہ بھائی ایسا نہیں کرتے جو دکھاتے ہیں وہی دیتے ہیں ان کی پروڈکٹس سو فیصد اوریجنل ہوتی ہیں میں ان کا کسٹمر ہو مجھے آج تک کوئی چیز غلط نہیں ملی
Mein ny osama bhai sy boht kuch liya or letaa rhy taa ho 1 No product boht zabrdast working online ye 1 banda hai jo froad ni kartaa mein qasim kha kar khy ta ho anky band kat ky kuch be ly sakty osama bhai sy u are great osama bhai
Function and working of earth leakage explained very nicely. I also had to install a parallel breaker. It's a good and safe device and we should install it in our homes .
Mairay ghar mein 4 pole Rccb laga hua hay aur woh aksar trip ho jata tha. Raat ko leakage trace kerna mushkil ho jata tha. Ap ki video daikh ker mein nay Rccb kay sath aik 4 pole Mcb parallel connect ker dia. Jsisay ap nay explain kia exactly waisay. Yeh dono breakers ikhatay on kerain to short circuit kyn hota aur main Mcb trip ho jata.
Great video, but your website is missing 10A RCBO units. I am redoing my home DB with main MCCB, each phase MCB/OP and then each room getting individual RCBO of 10A each (makes it better for fault isolation).
A.o.a Bahe ghr mn aik fridge or aik lal pani wali motor h. Plz koi achi sy company k breaker to bata o. Jis sy current kisi ko b ni lagy. Ghr mn meri wala hoti h phly un ko laga h current. Plz reply me
I have RCBO on one room circuit, but it keeps tripping. Room circuit has 4 switch panels (for lights), 3 sockets. 1 Fan and a couple of lights are on UPS. There is a single neutral for the circuit that is common for all light switches, sockets and UPS.. UPS is on another circuit which i closed to test. Can someone explain what needs to be fixed for the RCBO to not trip?
If UPS is single wired, then RCBO won't let that happen. It's in the functionality of earth breaker that it only keeps working if both neutral and phase are being used.
यदि गलती से फैज न्यूट्रल वायर अपने बॉडी पर टच हो जाएगा तो यह RCBO ट्रिप होगा या नहीं होगा,... मेरे घर में अर्थिंग नहीं है तो,मैं इसे मेरे घर पर आने वाली मीटर से सप्लाई के बाद लगाऊं तो सही रहेगा ना..पूरे घर में एक RCBO ?
السلام و علیکم ورحمتہ اللہ وبرکاتہ ۔ اچھا بھائی یہ بتائیں کہ مثال کے طور پر ہم نے 6 ایمپئیر کا بریکر لگایا تو کیا لوڈ 6 ایمپئیر سے کم کا ڈالنا چاہیے یا 6 ایمپئیر تک کا لوڈ ڈال سکتے ہیں ؟ تاکہ اور کرنٹ ہونے کی صورت میں بریکر ٹرپ کر جائے۔
yes we didnt mind apko zyada better pta hoga hum to ghr bethy bna rahy han kher ap ali express per ja k wahan dekh skty han or tomzn official store se pooch bhi skty han k hum unse buy krty han ya nahi wo khuyd apko bta denge
ماشاء اللہ بھائی آپ کا بات سمجھانے کا انداز بہت اچھا اور آسان ہے۔شکریہ بھائی
JazakAllah boht boht shukeria bhai
اپ اچھے انسان ہیں خود اپنی سیفٹی کے لئیے گلوز بھی پہن کر الیکٹرک سرکٹ پر کام کیا کریں اللہ اپ کو اور اس فیلڈ کے سب ھنر مندوں کی حفاظت فرمائے امین
جتنی انفارمیشن اسامہ بھائی دیتے ہیں اتنی انفارمیشن کوئی بھی نہیں دیتا ماشاء اللہ اللہ پاک سلامت رکھے آپ کو آن لائن بہت سے لوگ فراڈ کرتے ہیں لیکن اسامہ بھائی ایسا نہیں کرتے جو دکھاتے ہیں وہی دیتے ہیں ان کی پروڈکٹس سو فیصد اوریجنل ہوتی ہیں میں ان کا کسٹمر ہو مجھے آج تک کوئی چیز غلط نہیں ملی
JazakAllah imran bhai
Apki mohabbaton ka shukeria mere bhai
Agree
Bilkul sahi
100$ agreed
ایم۔سی۔بی۔ MCB اور آر۔سی۔بی۔او۔ RCBO میں موازنہ اور آر۔سی۔بی۔او۔ کے فوائد پہ اچھا ویلاگ کیا ھے اسامہ منصور نے۔
اسامہ بھائی اس دفع بھی بہت کچھ سیکھنے کو ملا ، جزاک اللہ
ماشاءاللہ بہت ہی زبر دست ہے
Masha Allah bahut mehanat ki hy ap ny hamaray liyay itni achi video bna k
jazakALLAH bhai
sir without earthing wiring k yeah kam karega properly matlab agar kise ko current lage tou trip ho jaega?
Mein ny osama bhai sy boht kuch liya or letaa rhy taa ho 1 No product boht zabrdast working online ye 1 banda hai jo froad ni kartaa mein qasim kha kar khy ta ho anky band kat ky kuch be ly sakty osama bhai sy u are great osama bhai
Function and working of earth leakage explained very nicely. I also had to install a parallel breaker. It's a good and safe device and we should install it in our homes .
ماشاءاللہ اللہ رزق میں برکت دے
Sir Tomzn Ki 63A 15 Satting wal protector lagaya hy lekin lin garam hojath hy ?
Mash Allah bahi bht A6a btaya aap NY Allah aap ko kush rakhy
Ur effort to describe is good. Even though we see it lately but it's informative . Keep it up
jazakALLAH bhai
Very informative video,
Bilal bhai JazakAllah ap kafi help krty han chezen smjhny main
Dill se boht shuker guzar hun apka
Mairay ghar mein 4 pole Rccb laga hua hay aur woh aksar trip ho jata tha. Raat ko leakage trace kerna mushkil ho jata tha.
Ap ki video daikh ker mein nay Rccb kay sath aik 4 pole Mcb parallel connect ker dia. Jsisay ap nay explain kia exactly waisay. Yeh dono breakers ikhatay on kerain to short circuit kyn hota aur main Mcb trip ho jata.
Sir bht acha se samjhta h 👌
ASSALAMUALAIKUM sir RCCB ko solar Db box main kha pr lagana hai mean input pr lagana hai ya output pr
WAPDA per alag inverter out per alag
@@BijliWalaBhai aor agar srif wapda input pr lgaya ho to work kry ga k nhi
God work usama bahi
Great video, but your website is missing 10A RCBO units. I am redoing my home DB with main MCCB, each phase MCB/OP and then each room getting individual RCBO of 10A each (makes it better for fault isolation).
min 16A available
actually no one buy 10A
90% people buy 63A
Very nice brother best video
Nice app ny boath achi tarha guide kya
Agr transformer sai leakage phase mtlb double phase a raha ho to earth breaker kaam krai ga ya ni?
yes
Mery pas soler setup hy with reverse metering this earth leakage breaker started tripping even foung no earthing. Koi solution hy aap ky pas
bhai ap input per q lga rahy han obviously trip krega
output per lgaen bs
Koi bhai batye jb m dewar sy ..lgye sariye sy earth lye rh ho to dewar grm kyu ho rhi ha kia waja hai? Bhai help
bijli chori na kren bhai
Koi bhai batye jb m dewar sy ..lgye sariye sy earth lye rh ho to dewar grm kyu ho rhi ha kia waja hai
dewwar se earth leke bijli chori kr rahy han?
Agr directly socket se kisi ko current lgta hy to kia ye trip hoga
yes bhai
kahin se b lagy to trip hoga
Masha Allah bhai zabar dus
What's the difference between the 3 RCBOs you showed.
A.o.a
Bahe ghr mn aik fridge or aik lal pani wali motor h. Plz koi achi sy company k breaker to bata o. Jis sy current kisi ko b ni lagy. Ghr mn meri wala hoti h phly un ko laga h current. Plz reply me
wslam bhai is kaam k liye installer se rabta krna hota hai apko
Sir,without earthing ka Rcbo ghar mai laga sakta ha kyA?
yes
Zabardast
sari baten thek hen par ap ny yeh nai bataya k 32 aur 63 amper kahan pe lagana chahye kindly yeh clear kar den
Aj march. 2022 is ki price kia hy
1300 for 20 and 25 and 32 A
1400 for 40 and 63A
Best information
Very informative
MaShaAllah
very nice continue dear
👍👍👍
I have RCBO on one room circuit, but it keeps tripping. Room circuit has 4 switch panels (for lights), 3 sockets. 1 Fan and a couple of lights are on UPS. There is a single neutral for the circuit that is common for all light switches, sockets and UPS.. UPS is on another circuit which i closed to test.
Can someone explain what needs to be fixed for the RCBO to not trip?
consult with senior electrician to solve your issue
your wirings having problem with common neutral
If UPS is single wired, then RCBO won't let that happen. It's in the functionality of earth breaker that it only keeps working if both neutral and phase are being used.
Thanks brother
nice work bhai
کیا پانی گرا کر ہی ارتھ لیکیج چیک کی جاسکتی ہے؟اگر آپ ڈائریکٹ فرش کے ساتھ کنیکٹ کرتے فیز کو تو کیا پھر بھی بریکر ٹرپ کرتا؟
Yes
company ne test button isi liye dia hota hai bhai breaker per
or tarikon se testing ki zarort nahi
Good gob ❤️
Thanks
Mera bhai ek video bano Earth rod ka install
Transformar ki traf say agr earth na hoyi ho to kya krna chayee us pr video banayain uska hall btayain jo banda ghar kr lay😊
Koi bhai batye jb m dewar sy ..lgye sariye sy earth lye rh ho to dewar grm kyu ho rhi ha kia waja hai???
Wel explained
यदि गलती से फैज न्यूट्रल वायर अपने बॉडी पर टच हो जाएगा तो यह RCBO ट्रिप होगा या नहीं होगा,... मेरे घर में अर्थिंग नहीं है तो,मैं इसे मेरे घर पर आने वाली मीटर से सप्लाई के बाद लगाऊं तो सही रहेगा ना..पूरे घर में एक RCBO ?
Mare pas ek single pole rcbo ha. Earthing nehi dea, phir bhi chal raha hay!
O earth wire dana ka matlab kya hay?? 😇
May socha tha earth fault hoga to trip hoga!!! 😟
earth dena zarori nahi hota
❤❤❤❤❤
Br make one video on afdd I am from kashmir
Nice
Great 👍
گھر میں پانی کی 1HP موٹر ایجکٹر میں 10A کا بریکر سپارک کر کے جل جاتا ہے کیا وجہ ہے
Exellent
Good
السلام و علیکم ورحمتہ اللہ وبرکاتہ ۔ اچھا بھائی یہ بتائیں کہ مثال کے طور پر ہم نے 6 ایمپئیر کا بریکر لگایا تو کیا لوڈ 6 ایمپئیر سے کم کا ڈالنا چاہیے یا 6 ایمپئیر تک کا لوڈ ڈال سکتے ہیں ؟
تاکہ اور کرنٹ ہونے کی صورت میں بریکر ٹرپ کر جائے۔
good brother ansar Mehmood dubai pakistan election
Dear Dont mind your rcbo is not original from tomzn.
yes we didnt mind
apko zyada better pta hoga hum to ghr bethy bna rahy han
kher ap ali express per ja k wahan dekh skty han or tomzn official store se pooch bhi skty han k hum unse buy krty han ya nahi
wo khuyd apko bta denge
V good
most of ur latest items short most of time
Alhamdulilah
is se andaza lgaen hamari sales ka
Gooooooooooda 👍
Sr g aap 👌
Aap ka contact no ya watsup no to show nhen h
Apun ko 3 breaker chahey
K Sy order kron😊
Very informative video
Good
Good