Bagfiltter 3hours k bad suction kam kr deta h....timing 30sec se 1min tak kar k dekh liya... Means running me dust paas nhi hota h ..uske lye blower bar bar off Krna padta h.
Aapne bola purging k time suction band ho jata hai kaise actuator ko to operate krna padega duct line bnd krne k liye aur dusri baat agar suction bnd hota hai to kya sirf jis line mein purging hota ussi line mein suction bnd hota hai? Suction bnd hona mtlb y to ID fan bnd krna y fir suction damper k gate bnd krna
Vo band hota hai actuator ki madad se pneumatic Cylinder connected rehta hai damper se Suppose 4 chamber (hopper ) hai apke bagfilter me to at a time 2 me suction hoga aur 2 me do me damper close rahega Jo close hoga us chambers me purging hota hai. Fir kuch samay baad baki k 2 chamber me suction hoga yani uska gate/damper khulega aur jiska khula tha vo band ho jayega . Ye sari settings apko apne hisab se karani hai ki kitne sec Tak konse chambers me gate open hoga kisme close aur usi hisab se purging bhi set Kiya jata hai.
@@superfaststudyexperiment 1-2 doubts aur hai clear kr dijiye sbse pehle bataye k agar koi dedusting system k capacity puchta hai iska mtlb kya ID fan k flow k capacity hota hai? dusra poppet cylinder jo outlet damper hota uska function kya upper chamber se air suction kr k ID fan k duct line k through chimney mein bhejna hota hai?third agar pulsing normal nhi hoti jaise ek time pr simultaneously 2 pulsing valve operate ho jaati hai to iska kya reason hai aur isko kaise correct kiya ja skta hai? kyuki is wajah se compressor k outlet pressure down ho jayega to automatically compressor trip ho skta hai.. aur ek chiz agar ID fan k vertical mein vibration bdta hai iska mtlb mechanical loose fitting higi y fir base structure k issue hoga, horizontal mein bdta hai to balancing y fir bearing k clearance k issue hai aur axial mein bdta hai to alignment k problem hai am i right y fir aur bhi kuch karan hote hai?
is this steady flow or static flow? If steady flow then how resistance increases pressure here (n same in case of blood flow) but in case of porous plug pressure gets reduced there? Im way confused , explain sir
बैग हाउस से dust को अपने आप नही छोड़ रहा है थोड़ा vibration देना पड़ता ऐसा प्रोब्लम exaust fan motor का लोड बढ़ाने के बाद हुआ है mean मोटर का बेल्ट थोड़ा टाइट किया मोटर का लोड़ा बढ़ाने का रीजन डस्ट प्रॉपर तरीके से एडजस्ट नहीं कर रहा था
Sir bag filters me jab solenoid valve k through pressure se air jati hy to us waqt outlet line me clean air k sath dust coal particles mix kyun nahi hoty..?
DP high low ke single reason bataye hai..aur details me batana chahiye. Bag new replace karne ke bad,purging off time kam kiya phir bhi DP kam nahi ho raha hai. Normal means? Bataya nahi hai video me.
Nice illustration
Thankyou
Sir meri industry mein bag filter Hain mere ko bahut fayda mila,ek video or bnaiye bag filter system ke liye
Thanks for provide me good knowledge ❤
Most welcome please like and subscribe
Dp= inlet pr - outlet pr, hota hai
Gas ka flow hmesa high pr se low pr ki or hota h, isliye niche chamber me pr high hoga or upr me low.
Exactly....so DP = Pr in Chamber 1 - Pr in Chamber 2; just opposite the way it has been shown in the video! 🤦♂🤦♂
Right
Mast sir aur videos banaiye sir
By this video I solved bag filter problem of plant
Great job brother
Thanks you sir this video ws very important for me
Most welcome brother please like and subscribe
Good information dear very nice
Thankyou
Very good explanation
Thankyou
thank you sir . just awesome video .. please make more animated and explained videos like these
Very nicely explained .
Thankyou please subscribe
Nice videos...
Thanks
Very good sir
Thanks and welcome
Sir, In our plant DP is above 200mmWC at positive draft +7 or above. What's the problem.
Well explained, thanks bro
Most welcome brother please subscribe there are number of such type of videos in this channel.
Thank you
Thenks for M.m.enginiring Works m.i.a.madri Udaipur Rajasthan India m.s.chohan
👍 great
Plz teach about blower house....its function and all parts/valves roles....
Simple and sober explanation..❤️❤️
Thankyou
good explanation naveed from Pakistan
Thankyou naveed
Thanks for give me,suggestions, nice video good explained about of suction line
Thankyou please like the video
What should be the normal differential pressure sir?
Thanks bro
Most welcome please like and subscribe
Sir ESP ka troublshooting ka Video banaiye...
Ok
Bagfiltter 3hours k bad suction kam kr deta h....timing 30sec se 1min tak kar k dekh liya...
Means running me dust paas nhi hota h ..uske lye blower bar bar off Krna padta h.
Blower thodi der k liye off kar dene se bag acche se clean ho jate hai.
Sir please told details video on water gauge basic and measurement process and can i convert in proper unit of pressure or not?
@@akhileshk.singhrishivanshi1837 ok brother
Hai sir
Dp = Inlet pressure - outlet pressure
= chamber 1-chamber 2
pls correct
Dear Sir, plz make video for I D fan & bag House & correlate between them.
Ok brother I will try
Can be find differential pressure by calculating of differential between pressure of incoming dusty air and outcoming clean air
Bag filter capacity calculation ka ek video bnaye
Ok
Plz explain about PCI...mainly its hydraulic part
Sir how to decided DP for bag filter & bag house
Sir bag filter ki capacity pr bhi ek video bna digiye
Aapne bola purging k time suction band ho jata hai kaise actuator ko to operate krna padega duct line bnd krne k liye aur dusri baat agar suction bnd hota hai to kya sirf jis line mein purging hota ussi line mein suction bnd hota hai? Suction bnd hona mtlb y to ID fan bnd krna y fir suction damper k gate bnd krna
Vo band hota hai actuator ki madad se pneumatic Cylinder connected rehta hai damper se
Suppose 4 chamber (hopper ) hai apke bagfilter me to at a time 2 me suction hoga aur 2 me do me damper close rahega Jo close hoga us chambers me purging hota hai.
Fir kuch samay baad baki k 2 chamber me suction hoga yani uska gate/damper khulega aur jiska khula tha vo band ho jayega .
Ye sari settings apko apne hisab se karani hai ki kitne sec Tak konse chambers me gate open hoga kisme close aur usi hisab se purging bhi set Kiya jata hai.
@@superfaststudyexperiment 1-2 doubts aur hai clear kr dijiye sbse pehle bataye k agar koi dedusting system k capacity puchta hai iska mtlb kya ID fan k flow k capacity hota hai? dusra poppet cylinder jo outlet damper hota uska function kya upper chamber se air suction kr k ID fan k duct line k through chimney mein bhejna hota hai?third agar pulsing normal nhi hoti jaise ek time pr simultaneously 2 pulsing valve operate ho jaati hai to iska kya reason hai aur isko kaise correct kiya ja skta hai? kyuki is wajah se compressor k outlet pressure down ho jayega to automatically compressor trip ho skta hai.. aur ek chiz agar ID fan k vertical mein vibration bdta hai iska mtlb mechanical loose fitting higi y fir base structure k issue hoga, horizontal mein bdta hai to balancing y fir bearing k clearance k issue hai aur axial mein bdta hai to alignment k problem hai am i right y fir aur bhi kuch karan hote hai?
Sir plz baigfilter timerer ,ZSS bss pull cat emagency push button ka connection electrical wairing ka delatls video banao plz
Differential pressure normally Kitna chahiye
KMD gear box k bare me video please
Ok
How to Install a Dust Collector Differential Pressure Sensor in bag filter please make a video and share sir
Please make video for Sr. Engineer level interview questions and answers.
Ok
Waiting
Dear Sir , please make a video on electro tar precipitator(ETP)
Ok brother
Thanks sir , Dp dekhne kie liye konsa equipment use hota hai
Manometers
Manometer
Sir bagfitter me kitna bag lagega calculation karke bataeye
Sir rollerpress ka video chiye
Hello sir..
Transfer chute jam honese control room se kaise operate karenge thoda video banayie..
Ok brother
Kya AFR mai bag filter kaam krega?
Hii sir
How to calculate draft pressure
is this steady flow or static flow? If steady flow then how resistance increases pressure here (n same in case of blood flow) but in case of porous plug pressure gets reduced there? Im way confused , explain sir
Why will DP go negative is there any explanation?
Jab solenoid valve bag filters me air purging karty hy us waqt suction stop hoti hy ya nahi?
Suction stop hoti hai damper close ho jata hai
Normal any Bagfilter how much dp required?
???
बैग हाउस से dust को अपने आप नही छोड़ रहा है थोड़ा vibration देना पड़ता
ऐसा प्रोब्लम exaust fan motor का लोड बढ़ाने के बाद हुआ है mean मोटर का बेल्ट थोड़ा टाइट किया
मोटर का लोड़ा बढ़ाने का रीजन
डस्ट प्रॉपर तरीके से एडजस्ट नहीं कर रहा था
Normal dp kitna rahana chahiye....??
Sir bag filters me jab solenoid valve k through pressure se air jati hy to us waqt outlet line me clean air k sath dust coal particles mix kyun nahi hoty..?
Kyu ki bag filter dust particles ko Ane hi nahi deta hai sirf air hi pass ho pati hai
Sir water gauge ke bare me or detail me video banaiye
Ok
Sir plz discuss about air to cloth Ratio......
Ok
Bag filter on and off time discuss plz
Sar chane ke bare mein video bataiye Kaise major Kiya jata hai
Sir
Please explain about blow down of the boiler...
Ok brother
What is normal range DP bag house
How to calculate the size of Dust collector and Bad size
Dear sir how to convert inch into in mmWG?
I will try to make video on it
DP high low ke single reason bataye hai..aur details me batana chahiye.
Bag new replace karne ke bad,purging off time kam kiya phir bhi DP kam nahi ho raha hai.
Normal means? Bataya nahi hai video me.
If dp not down that means some problem in design or bags is totally chocked.
Sir why RAV needed in bag filter????
For discharge material RAV is used . Just to stop false air to enter chamber from discharge side.
The way you have explained is too good ✌️ .good job keep going.👍
Thankyou please like & subscribe
Nehni app wrong bolreho inlet chamber me jyada pressure rehta he outlet se..
LinkedIn bekar apps hai
Bag house/febric filter ke bare me batao na yr
Very Nice explanation
Thankyou