Sirji compressor kharab hai ye kaisae pata chalega? Sirji ye amp meter keya zeyada reading nahi bata raha hai. It should have to be 0.02, but it's showing 6 why?
Bhai suction se kaise aapne kyun check Kara k mashin block hai ya nahi chock nahi hota hoga to ho jayega bahar ki air ander chali jayegi is condition m to
Aap compressor ko air me 2 3 minut tak chala sakte hain uss men koyee problem nahi hai But agar suxan line pe ye nahi check karte aur Brazilian nge karte samai pipe kahi block ho gayee hogi to choke to 100% ho jayega iss liye ye check karna jaroori hota hai
@@kareemtechnicalmind8172 bhai fridge ke compressor me gass bharne ke baad bhi cooling kam ho rahi h jese new fridge me cooling hoti thi wesi nahi ho rahi h solution bataiye
Sir hame nahi samajh me aata hai ki kon secksen paip aur kon discharge paip aur secksen paip ko kaha par lagate hai aur discharge paip ko kaha par lagayenge sir
Compressor jiss pipe se hawa kheech raha hai wah suxan line hai Aur jidhar se fek raha hai wah dischage line hai Discharge line pe condensor juda hota hai Suxan line pe evaporator juda hota hai
Bhai aapka work professional h ❤
Arie Bhai Aise kaam mai flashing bohat zaroori hota hai 💯
Accha ji
Right sister
Nhi
Right flasing krne pipe ka rasta clear hota hai
Bahut badiya
A good idea is to fill the compressor with water before regassing. Then there is no need to vacuum
Agar compresor discharge se presor oil nikale to kya compresor ko change krde
No
Sestem k ander compresor ne bhot jyada oil bej rakha tha sir
Mere senier ne kha compresor khrb hai🤔
Good sir
Kitna paisa lagega agar naya compressor hai mere paßs bs badlna hai
Compressor kitne ka pada
Sir sel bhaikamp nhi kijiyega sir
New compressor me gas bhar ke ati h ke bharbani padti h
Bharni padti h
Sir ji. Mera LG ka compressor hai full shot Bata Raha hai Naya kitne me aayega
3000/ tak aiga😂
Kahan se ho
Udaipur से
Price kitna hai
Sirji compressor kharab hai ye kaisae pata chalega?
Sirji ye amp meter keya zeyada reading nahi bata raha hai. It should have to be 0.02, but it's showing 6 why?
Jan hamare fridge me poori gas hoti hai to fridge lagbhag 6 amp hi leti hai
Compressor ko kaise check kiya jata hai neeche link hai
m.th-cam.com/video/mH5esBCfhJQ/w-d-xo.html
सर आपने कैपसिटर कितने mfd का लगाया?
और मेरे पास 43 नंबर कंप्रेशर है बिल्कुल न्यू क्या वो लगा सकते हैं?
6 mfd laga hai to laga do nahi to jane do agar nahi laga hai
Great Sir G
Sir pipe zyada heat krege to pipe pighle ka to nhi
Bahut jada heat bhi nahi karenge
Agar compressor me gas ho to kese kare
Bhai fridge compressor price kitna hai 🙏🙏🙏🙏🙏
2600
Bhai suction se kaise aapne kyun check Kara k mashin block hai ya nahi chock nahi hota hoga to ho jayega bahar ki air ander chali jayegi is condition m to
Aap compressor ko air me 2 3 minut tak chala sakte hain uss men koyee problem nahi hai
But agar suxan line pe ye nahi check karte aur Brazilian nge karte samai pipe kahi block ho gayee hogi to choke to 100% ho jayega iss liye ye check karna jaroori hota hai
Good bhi
lock to h nhi bolt h lage huye
Sir online courses karate hai
Nahi
@@kareemtechnicalmind8172 bhai fridge ke compressor me gass bharne ke baad bhi cooling kam ho rahi h jese new fridge me cooling hoti thi wesi nahi ho rahi h solution bataiye
@@tourofuniverse7890 gas kam dale honge
Ya compressor ka pressur down hoga
Sir hame nahi samajh me aata hai ki kon secksen paip aur kon discharge paip aur secksen paip ko kaha par lagate hai aur discharge paip ko kaha par lagayenge sir
Compressor jiss pipe se hawa kheech raha hai wah suxan line hai
Aur jidhar se fek raha hai wah dischage line hai
Discharge line pe condensor juda hota hai
Suxan line pe evaporator juda hota hai
@@kareemtechnicalmind8172 थैंक्स सर ma be jahi सोच रहा था
Kampareshar ka 10 saal ka geranti rahta hai
Dimag he ya nahi bhai Iran paie par tiub katar nahi lagate 🤦
Iron paper pe tube cutter laga rahe hain ya pipe pe iron paper pipe pe thodi laga rahega
hi
Hi