How to adjust the hydraulic load sensing pump : training course

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 พ.ย. 2024

ความคิดเห็น • 10

  • @charlesmac4356
    @charlesmac4356 2 ปีที่แล้ว +2

    Hi sir when you set pressure on loadsensing pump with one you set first between system relief valve and loadsensing

    • @sebhydroformation2732
      @sebhydroformation2732  2 ปีที่แล้ว

      Thank you for your interest
      First the pressure limiter is adjusted, then the standby pressure and finally the constant pressure.

    • @charlesmac4356
      @charlesmac4356 2 ปีที่แล้ว

      Relief valve is set first sir

    • @charlesmac4356
      @charlesmac4356 2 ปีที่แล้ว

      System relief valve should be 200bar

    • @sebhydroformation2732
      @sebhydroformation2732  2 ปีที่แล้ว +2

      - 1: Read the hydraulic diagram and install a pressure gauge (0-400 bars) between the pump and the directional valve.
      - 2: Completely loosen the pressure relief valve (LP).
      - 3: Completely loosen the LS valve (Item 21) and constant pressure valve (Item 17) settings. (Be careful, there is often no stop on the adjustment screws).
      - 4: Start the pump.
      - 5: Gradually tighten the LS valve (Item 21) and the constant pressure valve (Item 17). The pump is transformed into a fixed displacement pump. The pump starts in displacement, all of its flow returns to the tank via the pressure relief valve (LP) at a low pressure observed in M1.
      - 6: Gradually tighten the pressure limiter (LP), the pressure must gradually rise on the M1 pressure gauge until it reaches 280 bars. The pressure relief valve is set.
      - 7: Loosen the LS valve until reaching 25 bars on the M1 pressure gauge, the pump cancels its displacement and don't give flow. Change the pressure gauge by taking a smaller caliber (0-60 bars to adjust the stand-by pressure to 25 bars). The LS valve is adjusted. Replace the 0-400 bar pressure gauge.
      - 8: Actuate the directional valve (D1), wait for the cylinder (V1) to reach the mechanical stop.
      - 9: When the cylinder reaches the mechanical stop, gradually loosen the constant pressure valve (Item 17) until reaching 250 bars read on the M1 manometer. The constant pressure valve is set.

  • @sajitheeshwara5070
    @sajitheeshwara5070 3 ปีที่แล้ว +1

    Good knowledge... thank u

  • @sebhydroformation2732
    @sebhydroformation2732  3 ปีที่แล้ว +1

    La vidéo en francais : th-cam.com/video/WdJFeUSG01Q/w-d-xo.html

  • @sanjaywade5126
    @sanjaywade5126 2 ปีที่แล้ว +1

    More disturbance created to your summary word ..not to good seen it