Hi, let me check with my local supply store see can get that switch a not. The theory is same with 1gang2way . it just for 20a switch the back wire connection bar had neutral pole. Thanks for the suggestion. I hope i can film this soon😀👍
If accidentally mix up the in/out. The switch can still function as on off. It just the on light indicator will keeps lights up although the button is at the off position.
Hi Andrew, There are 2set of wire at the switches, which is the incoming supply and outgoing to electronic devices. Each sets had 3 wires. Live is (red,blue,yellow) Neutral (normally black) Earth (green) There are 2 type of indicator on the switch First type is Line and Load. 2nd type is 1 and 2 Line indicates incoming Load is outgoing Example: line L ,N which means the supply wire live red connect to line L And the other sets goes to the Load section.. Example 2: L1,L2 N1, N2. L1 is to attach incoming for live wire. L2 is live wire for the outgoing to electronic devices . Same goes with N1/2 . Hope my explanation helps. Or i can make a video with demostration for better explanation 😉
Guys, sorry to mention that for connecting Portable Appliances to Supply Side, we dont use Cable Link which is Permanently Crimped. Also you wont be linking a Flexible Cord to Stranded Wire2.5mm² with any cable link? No we dont.🚫😒 The best way to do it is via PlugTop13a_15a. Alternatively, use approved Wall Termination Unit. If budget is a factor, consider connecting the Flexible Cord DIRECTLY into the DP20a switch Load Side(its allowed if the Flexible Cord is minimum/short length) For extending the 2.5mm² Supply Wires into the DP20a, its better to avoid passing thru ConnectorBlock. Instead buy larger ConnectorBlock and TWIST the 2 wires TOGETHER and insert them into the large ConnectorBlock and tighten it with 2 screws(2 wires all go into 1 same hole). It is strong as bull and last forever...👍👍
老板你好,想请问电炉kitchen hob是可以直接链接跟20A switch的对吗?因为看到的都是电炉15A插头链接到15A插座先(再kitchen cabinet里面),再链接到一个20A double pole switch (kitchen cabinet上面).
如果我的厨房会敲过,是可以省掉一个15A插座,是这样吗?非常谢谢你。
请问可以向你请教20A 2 Way Wire 要怎么连接吗?谢谢
想请问你.L1是不是进电 (line)? L2是不是出电(load)?
是的😀
1马力的冷气插头开关能不能换这个20a开关?因为我想买智能Zigbee20a开关替换这个插头开关?
可以啊,用这个原理链接来弄开关。
@@Handyman2Uchannel 谢谢
helpful and clear explanation. Good effort!
请问20A也是用于热水器开关吗
是的,也是用这个
再请教一个问题 黑色线要怎么确认装对了 因为没有显示灯
黑线incoming 如果进错 Line 去到 Load 也是没大碍。 但是 L ,N 不要放错就可以了。
这20a switch 通常就是不小心进错,然后没有开switch 那个昭示灯就亮。 这个情况你就把那两个 L 倒转放就可以了。
如果你要check 哪一条是incoming 的红线 和 黑线 ,你需要准备test light.
你可以拿downlight 来test.
电线一个插下去红 ,另一个插去黑。 如果那个downlight 亮起来,就是那个电线是incoming. 可以链接去 (Line)
剩下那两条黑红就是 去热水器的电线,那个就链接去 (Load)
谢谢你 解决了 我用Multimeter 调AC240V, 一个点red line L1 和 black L1 - 出来的的结果如果是240V 就是对的 如果少于就是错的。。
有multimeter 哦😀👍👍
bother you a bit, can you make a video of the 4-way water heater reversing switch?
Hi, let me check with my local supply store see can get that switch a not.
The theory is same with 1gang2way . it just for 20a switch the back wire connection bar had neutral pole.
Thanks for the suggestion. I hope i can film this soon😀👍
请问有compressor 的话可以用20a?
可以啊
@@Handyman2Uchannel350v的电器也可以用20 a?
有有,真的很赞,我直接share给我2个朋友,因为他们也是和我一样有兴趣学👍👍👍真的很谢谢你的分享呢,获益不浅
谢谢观看, 难得对这类型的影片有兴趣 😅 在马来西亚看这类型的观众其实并不多, 谢谢你的支持!
0k.非常明白.非常谢谢你..还有一个.就是地線,有2条,是不是2条都不分左右插?没关系的是吗?
啊 对, 青色没分的。 一边一个也可以, 两条绑着进一个入口也可以
想了解 3button switch的种类 还有连接方式,希望有机会学到,谢谢
th-cam.com/video/Kg8sqod5Nrg/w-d-xo.htmlsi=clFCXPHr5xwCRJV9
这个有讲解到,希望你能得到你的答案
@@Handyman2Uchannel 可能我的理解能力有问题,还是不太理解 😥
没关系我再研究看看,谢谢你 🙏
hi Maxiu Wong, 我的20A Switch 可以从 socket 13A 拿电吗?给我抽烟机用的。谢谢你。
可以啊
我同樣有一个這種即熱電熱水炉用的開關制,我的問題是白色那粒按鈕按下時會發覺有按不盡的感覺,好似按得一半,而红橙指示有時全亮,半亮或很暗,根據這樣情况,熱水爐的出水時冷時熱,請教如何修理.謝谢
你好,这种情况的话多数是那粒开关键即将要坏了。
去买一粒新的20a 开关键来更换就可以了。 施工时记得把电源关掉,要注意安全
依照全部做了,但起初on 了时,插头有灯着,但热水器没着灯.后再检查再锁紧下,开时,插头一下有灯,一下就没灯了..没有跳电,没有任何声音.清问是什么原理呢?
Just wonder, what will happen if incoming and outgoing mix up?
If accidentally mix up the in/out. The switch can still function as on off. It just the on light indicator will keeps lights up although the button is at the off position.
Just remember dont mix up with Live and neutral. It will trip ,switch will be damaged and maybe the fuse will need to replace as well.
@@Handyman2Uchannel thanks bro for the information
请问,
1)线是用 2.5mm 吗?(给 Oven, Microwave 甚至 Water Heater 2.5mm 就够了?)
2)厨房的 Wall Plug/Socket 是不是一定要用 4mm 的线?(热水壶、电炉 - 2500-3500w 使用)
3)Switch 有 Fuse 如 20A,那 Socket 呢?有分吗?还是都没有 Fuse?
其实电线一个fuse出一个的话 2.5就够用了, 当然如果可以用4mm 的电线那是最好比较耐热。2.5mm 电线一般都会用20a fuse这条电路供应的电源大约4800 watt 。
4mm 电线可以用32a fuse. 这条电路能供应的电源可以高达 7800watt.
每当使用电源,电线就会发热, 这时就要看电线的大小,当然电线越粗就越耐热。
32a fuse 如果放 2.5mm电线其实也是行得通,可是为什么多数都用4mm 是因为电线如果太幼会发热,融化甚至燃烧起来。 只是担心电线料不足,容易发热而mcb fuse 不会跳闸。 一般上如果电量过载,或有短路才会跳闸。 如果燃烧的电线只是一条,并没有烧到另两条,这样就不会短路了,也就是说不会跳闸。 这样下去会燃烧起来。
如果是1.5mm 放32a 就真的会烧起来😂
烧了都还没跳闸。
至于switch 的20a ,其实是指这个switch 的copper 能承受的电流是 20a 的电量。
如果 TNB meter 来的电压是 255v ,
245v X 20a = 4900watt
这个switch 能承受 4900watt 的电流。 这个就跟 wire connector 一样的原理, 有分6a,10a,15a,20a,32a 的种类/大小。
如果链接oven 用10a connector,这个链接 就会融化。
最后你提到的socket 是否有fuse. 其实在家的每一个电都有fuse. 看到总电箱那里有 6a, 10a, 20a 都是给不同的用处。 6, 10 是灯风扇
20,32 是给电插座,热水器,冷气switch.
🤩@@Handyman2Uchannel 你也太用心了啦!感动啊~ 这里满满的知识啊 👍 多谢多谢!
1)电线的粗细和 Fuse 的配合,讲解得很清楚。终于有点概念了!
a- MCB Fuse 我们需要检查吗?会不会有失灵,不跳闸的情况?
b- 你可以讲解一下 1 Phrase 和 3 Phrase 的分别等吗?
c- 有关 Watts,比方说微波炉的钮最大可到 800watts,是不是表示这电器是 Max 800watts?
d- 所以,我们在安排插座的时候就要先算好要用的电器的总电量 Watts,再决定电线厚度和 Fuse 的大小,对吗?但,如果一般的 standby 插座 2.5mm 电线 + 15A 就很足够了,对吗?
----------
2)谢谢你把 Switch 的承载电量和和计算法解释得如此容易明白。受益了!
a- 最近的 Water Heater 有些毛病 (Switch On 的时候像断断续续接不到点一样,Heater 显示灯也随着一并跳个不停),就上 Plaster Ceiling 看看。天啊,Heater Wire 接到来电的 Connector 竟然溶了、黑黑一团!刚好你回复了这段话,一看,拉电技术人员竟然用了小的 Connector 来连接!😯 这么巧手上有一排大的 Connector,就赶紧换上。读了你的讯息才恍然大悟,就连这个半透明的 Connector 也有大小 Amp 之分 -- 就在背面。要很仔细的看才发觉 -- 晓得 10A,大的 20A!真的太感激你的分享了。再获益,哈哈哈。
a.1- 题外话:有关上述的 Water Heater 毛病,不知 Maxiu 兄有什么想法吗? (* 换了 Switch,从 Wall Socket 供电 Water Heater,Reset 了,结果还是一样)。电路板坏了?
b- 那,如果像厨房墙上插座 4mm 的电线太短 (换 Socket 困难),可以用 20A 的 Connector 延长些吗?
----------
3)总电箱,嗯,这个明白了!
a- 如果 Water Heater 没有 Pump,想外置 Pump (24v),可以直接从 Water Heater 来电 Connector 拿电吗?
非常期待你的指教 🤩
请教下,如果我买的heater switch没有标哪个是L/N的孔, 是不是左右都可以用(只要确保左上和左下同样是L/N就可以了?) 谢谢
一般上都是parallel的, 左上左下是一组,
来电L 上面,拿电L下面
右上右下一组
来电N上面,拿电N下面
你好
我安装好heater switch后 switch 关灯亮着(可是比较暗),ON就正常亮度,这是正常吗?
你好, 很有可能是黑线调转。 试下N1 和 N2 调转看看, 如果还是一样那就是 switch 的昭示灯坏了。 可是如果不要理他也是可以照常使用的,最主要可以开可以关就没为题了。
@@Handyman2Uchannel 谢谢你的回复,
water heater 安装青线比较安全吗?
(我看到有2条没有链接的青色线)
@@tammycheah4329 如果 Earth (青线) 没有接上 Heater,理当 Heater 的 “Line Fault” 会亮红灯!很多施工的是外劳,没有真正拉好点,相当危险。有师父说,可以将 Heater 的 Earth 连到 Downlight 的 Earth 线。 @Handyman 2 U 对吗?
你好,如果L1和L2的neutral wire倒转会怎样吗
你好,
如果电线没跟回位置会发生两种事故。
先讲危险的。。
情况1
如果incoming L 和N 分别插入L1,L2 这就会在你面前炸掉,出现火花,DB 跳fuse。
情况2
如果incoming L插入 L2 ,incoming N 插入N2.
无论 Switch是开或者关的状态, 显示灯就会一直亮着, 但是开关可以照常使用。
所以最好要看清楚。 如果电线是倒转,好像情况2那样还好,没什么大碍。
不要好像情况1就可以了😂 注意安全,祝尝试愉快😁💪💪
My 20A switches only have 1 earth pin, can both yellow/ green cable put in together?
青黃線只有一個鎖夾, 可以一起鎖嗎?
Yes Can if is earth u can screw it together, but make sure both wire is earth wire.
what if my 20A switch dont have place to hold earth wire ?
Is OK , the incoming and outgoing earth wire just connect together and then cover with the wire tape
你好,我刚买了一个新的heater switch自己换,换了可是用了几分钟后就闻到有塑胶烧焦的味道,想问问到底是哪里出现了问题。
你好,先检查看看电线是否牢固的链接,如果没锁紧会有这情况。
一般heater 主要是有4条先,
来电 (Line) (L1/N1)
1条L(testpen 插下去有电), 1条N
去heater (Load) (L2/N2)
一条L( testpen插下去没电),1条N
而青先来回的链接在一起就可以。
如果line 和load 不小心参乱了还可以用最多switch 的灯会一直两这吧了。
但最重要是N 和L 不要参乱,因为他会在你面前炸起来出火花,然后家里就跳电。 switch就可能要用新的。
哦哦 那么请问电线没有牢固的链接是指螺丝没有锁紧的意思吗?
对, 如果电线是确定进对动。 就是链接电线时记得关电, 然后电线剥皮弄个小U 型凹回转头所以触摸到的面积较大会比较好。 然后锁紧后轻轻拉下确保他没有脱落就代表紧了
请问我换过新的开关还是一样跳fuse是什么问题呢?
有进对孔吗? L1 L2 倒反没什么大碍。 可是 L 和 N 就不可以倒反。
如果进对孔的话, 那可能那个电器有问题了。 先吧那个电器的电线拆除。 然后再开电。 如果没跳就是电器有问题了。
@@Handyman2Uchannel 请问要怎样分辨线呢?
@@vuittonxxiii1153 你有multimeter 吗? 开机然后打到600v AC 用针来测量如果机器出先 240-255 v 的读数, 那两条就是Live 和Neutral 。 不然的话你用test pen 测试,只能测试到那一个是Live 罢了,neutral 测试不到。
或者可以参考这个,
th-cam.com/video/GKPc0tLRWrI/w-d-xo.html
跳过到 13 .30
@@Handyman2Uchannel 没有哦,我明天再试看能不能😂
@@Handyman2Uchannel我的四条线是两黑两白的
老板你好 如果 插头上面写L1 L2 代表什么 热水器插头里面显示L1 L2&N1
L1 L2 N1&N2
你好
从总电箱来的电线
Live =L1 (这个有电,所以链接时要关fuse)
Neutral = N1
要链接去热水器的电线
Live= L2
Neutral= N2
Hi 你好,我想请问一下。我家里目前外面是有一个3pin插头,里面是用这一种的开关来控制。也是用一样的安装方式吗?
你好, 你是说要用 20A switch 来控制3pin 插头 开关电是吗。
可以, 就当作那个3pin 是output
@@Handyman2Uchannel 一样的安装方式吗?
是的一样方法,来电本来去3pin
就好像这影片样, 6条线拉到新switch 的地方,第一组链接来电,
第二组链接3pin 插头
@@Handyman2Uchannel 好的谢谢你的直到,我做到了。
@@Handyman2Uchannel 抽烟机也一样方式吗?
你好,我有东西请教你,我买了一个墙壁的开关键不过那个开关键只有L1和Com,然后我把我原本墙壁的开关键脱下来我看到的是只有L1和L2罢了,我可不可以把L1接L1然后L2接去Com呢?
你好, 原本墙壁 如果只有两个链接点的话 ,你可以
L1 -}L1
L2 -} com
原装这个是single switch panel (1gang1way) 吗?
补充一下我墙壁总共有4条线,4条都是白色的,有3条是接去L1,一条是接去L2,然后我用testpen试了,当我关灯L1是有电,L2是没电,我开灯后就L1,L2都有电,所以换新的开关要怎样接,麻烦你了。。
@@JCJackChin 可以,那3条白的是来电, L2的1条 是给灯/风扇。
所以现在你把
3条白的链接到 com
剩下的那条链接 L1
那三条白的要链接好,不然其他房间会没电connection.
我也是遇到类似的问题 我现在的灯开不到了 我拆开的时候 是三条黄色接L1 一条白色接com 开关的时候有时L1那边会出电 请问怎样解决吖 谢谢
你拿test pen 插下去那个3条 wire 那边看看有没有电, 如果有就是讲那个是来电(incoming)
然后下一个步骤就是check 这个switch 有没有坏, 你开switch 拿testpen 插下去看这条有没有电。 如果没电就是switch 坏, 换switch.
如果有电就是灯坏
那個延長電綫粗幼有講究嗎?
你好, 其实如果可以的话就用 2.5/3c. 就是我连接热水器哪个视频的电线。这个可以给消耗稍微大量电源的电器使用。
但是一般上 0.7/3c 或 1.5/3c 已经足够用了。
你好,我买的heater switch下面还有链接着两条黑色的wire (应该是forswitch的红灯的),想请问你那两条wire要接去哪个洞呢?😬
Hi~ 如果有两条黑色 wire 就是说那个是LOAD L2 N2(去往 电器的方向)
要注意 L 和 N 的位置 , 没有 黑色 WIRE 的 那个是 来电 (LINE)L1 N1
我的switch的L1, L2, N1, N2跟你video的switch一样位置。可是switch本身来的时候下面还有接着两条黑色的wire (没错的话是链接跟switch自己的灯的)想问你那两条wire要接去哪个洞呢? (Model是Simon E3 20A switch)
那两条黑色是给switch 亮灯用的, 把他链接在 L2. 和 N2.
(如果放在 1 那边,灯会一直亮着)
所以要放在2 那边。 黑色L N 随便放进去没问题。 放在2就对了
@@Handyman2Uchannel 好的好的👍非常感谢你🙏 ☺️
Nice video.
Tq bro
Harap video ni bermanfaat 😄
我家的oven 电流用socket 开关
Socket也是可以,至少可以拔出来,好过 direct😅.
这个情况是direct 链接插座都没有。所以就弄一个20a switch
Handyman 你在哪一区的?
你好我来自KL ,old klang road 区
大佬,如果L和N进的,调转接了会怎样。。。。🤣
如果L 你当N放
N 1,2 都放L 没事。可以的话就跟回指定的位子。
但是,如果 L 1 ,L2 一个放N ,一个放L就危险。 这switch 就在你面前炸起来。
总电闸会跳, 这switch 如果烧焦了可能不能用了。 要小心
@@Handyman2Uchannel 谢谢你,幸好装上去没错,因为拆下来前忘记做记号
请问下 开关OFF的时候指示灯亮 反而ON的时候指示灯就灭 是哪里装反了吗?
你好,你的这款是不是开关键跟指示灯一样小粒? 如果是的话就是这个switch的零件来到有问题。 内部需要拔出来倒反放回去。
通常我直接换别款的 20a switch 再装下去。
因为如果电线装反的话通常就是无论开或关,指示灯都亮着。
方便来一个安装空调教学!
我没有进冷煤的仪器😂 我在看看怎样
我的热水器插座好快坏,今天我们折了来看 ,有6条線.2条黑,2条蓝,2条青.我们发现那2条黑竟插L, 2条蓝插入N 、青插入一一个connecter是不是错了.我的这插座一暂子没灯没来电,一暂子没电了.才不很久,才换一个月那样
如果L ,N 倒转也是可以function 的。 L 1,L2 一定要同颜色,
N 1,N2 是另一组颜色。
但是最好就跟会switch 入口的指示。
现在你的问题首先要check incoming 有没有 supply. 如果有就把电线插入新的20a switch 的( Line)L1,N1..
如果没有就check DB Box 看看有没有fuse 跌下来。
Settle 了incoming ,接下来就是把Load的电线 连接到 L2,N2..
就应该可以了
terima kasih
Harap video bermanfaat. Saya dicadang bicara dlm bm. Nanti ada i upload 😆
i cant see how you really attach / connect with the wire.
Hi Andrew,
There are 2set of wire at the switches, which is the incoming supply and outgoing to electronic devices.
Each sets had 3 wires.
Live is (red,blue,yellow)
Neutral (normally black)
Earth (green)
There are 2 type of indicator on the switch
First type is Line and Load.
2nd type is 1 and 2
Line indicates incoming
Load is outgoing
Example: line L ,N which means the supply wire live red connect to line L
And the other sets goes to the Load section..
Example 2:
L1,L2 N1, N2.
L1 is to attach incoming for live wire.
L2 is live wire for the outgoing to electronic devices .
Same goes with N1/2 .
Hope my explanation helps.
Or i can make a video with demostration for better explanation 😉
视频模糊,也看不清楚电线放哪里哟
下次我再拍过😅那时还不懂拍摄的细节
想看渠道插座
是说好像 track light 的那种插座吗, 好的有机会我拍一集。
有这个方便很多,省很多功夫。 2米长的放一条,插座可以随意移动
@@Handyman2Uchannel 对,安全考虑,厨房电器太多了。拔来拔去。
Socket switch behind oven
那样的话就跟视频的情况差不多。 好处就是至少有socket.
要弄的话就是把原有链接到这socket 的电线拆出来,延长电线拉到switch 放入Line in ..
然后 switch 的Load拉回3条线回到那个socket 那里链接到socket 上。
Oven的插头就插回去就可以了。
链接电线时记得关总电闸。但如果可以找到独立的电闸把它关掉当然最好。
我看见用了两个connector
Connector 确保是15a 或20a 的. 小个的久了就不耐会融化。
一个是跟从墙上的来电链接进入switch.
然后从switch 出来 ,链接另一个connector 到 oven/microwave 电线。
up主的解释有点简化了。电器用高用量,所以必须小心,避免意外,所以补充一下,让你清楚明白。
1)有marking的就是接switch的Line/L1,另一边的marking接墙壁来电的电线,这里用好的connector(15-20a)。
2)没有marking的就是接switch的Load/L2,另一边没有marking的接电器(微波炉),这里也用好的connector(15-20a)。
电流这样走,墙壁-->L1-->Switch on/off --> L2 --> 微波。
up主其实讲很清楚了,对新手比较难而已。
up主认可这个解释吗?
用量20A不应该用connector来接wire,时间久了connector会burn.这不建议。
是的,最好是插头和插座。 可是顾客不要花这个钱。 我唯有用 20A connector 链接😅
@@Handyman2Uchannel 那你应该用cable link接啊!!不是因为屋主不使得花钱就草草这样做。要以安全性为主!
STEVEN CHEW cable link?😲😒
通常,如果要链接16mm cable for rcb 我用cable link 链接因为电线需要 extend. Cable link是一个圆通铁片,电线两边插下去然后夹紧。
Guys, sorry to mention that for connecting Portable Appliances to Supply Side, we dont use Cable Link which is Permanently Crimped.
Also you wont be linking a Flexible Cord to Stranded Wire2.5mm² with any cable link? No we dont.🚫😒
The best way to do it is via PlugTop13a_15a. Alternatively, use approved Wall Termination Unit.
If budget is a factor, consider connecting the Flexible Cord DIRECTLY into the DP20a switch Load Side(its allowed if the Flexible Cord is minimum/short length)
For extending the 2.5mm² Supply Wires into the DP20a, its better to avoid passing thru ConnectorBlock. Instead buy larger ConnectorBlock and TWIST the 2 wires TOGETHER and insert them into the large ConnectorBlock and tighten it with 2 screws(2 wires all go into 1 same hole).
It is strong as bull and last forever...👍👍
Air-Conditioner = Air Cond
😅
Tq for the typo 😂
Good video ..请问这位仁兄这样的线路是否正确 th-cam.com/video/bGnlxlJOUFQ/w-d-xo.html
他的好像不work 吧。。 最后没有试下test run的😅。 20a switch 一边是Live 一边是neutral 都不通电的。
666
🙆