1.5 hp ka submersible okay Par kitna stage ka hai ?? Or kitne feet niche lga rakhe hai ?? Submersible on karne ke bad voltage kitna rehta hai or on karne se pehle kitna tha ?? Submersible on karne ke bad AMP kitna rehta hai ??
Bhai mera borewell (8")700 5:06 ft ka hai...bore karne samai 60 ft mai pani aya tha..fir last tak nhi aya..bad me dekhe to 10 ft niche pani hai....ismi kon sa pump lagane se sahi rahega jisme minimum 1hr pani milega for cultivation 🙏
पम्प से वोल्टेज ड्रॉप नही होते बल्कि सिस्टम से वोल्टेज आते ही कम है,, बाकी लोड़ पर कुछ वोल्टेज ड्राप होना तो आम बात है,, जो कोई बड़ी समस्या नही है। बड़ी समस्या है ट्रांसफॉर्मर से वोल्टेज कम आना।
Hamara bore 350 feet hai or motor 300 foot pr hai 1 HP ki motor hai or pani sirf 20-25 min aata hai pani kam aata hai or pressure low rehta hai thoda bhut or voltage on krne se phle 220 rehta hai or on krne ke baad 200 ho jata hai Ap kuch solution batao is cheez ka
720 feet borewell.. Water level.. 20feet.. Motor level 380feet 3hp.. 23stage.. Water output 1hour pressure After 1hour pressure slow Motor 1minute off-on.. Water comes in good pressure.. What is the reason.. Solution please...
total 600 ft gaya haie summer toda kama hata hai now meter mai starting 13.6 13.4 and 13.2 and 10.6 hoa gaya already 4 years hoa gaya hai what problem hai please tell me sir.
सर जी पूरा बोरवेल 680 फीट और पानी 580 पे लगा हुआ हा बोरवेल में 7.5 (20) स्टेज 6 नोजल ही फेक रेहा हा पानी पूरा 24 घंटे चलता हा पानी में कोई टूट नहीं हा कोई उपाय बताए काहा या कितने फीट पर मोटर होनी चाहिए
Video achha he miri pump me 2 sall se 34vminit lagta he tanke bharne me 750 ltr ka he. Pehle 12 minit me bhar jata tha. Kala kal Pani bhi ata he keya problem ho sakta he
Sir hamara 10 hp motar 10 stage ka pump hai or 650 fit par hai jab start karte he to adha khanata full pani deta hai fir kam ho jata eksa kya problem hoga please reply
@@niteshrathva34 yeah submersible ki problem nahi hai 100% Problem hai borewell ke water source ki 30 min ke bad pani borewell dry hone lag rahi hai Esliye pressure down hota chala jayega Kyuki submersible ki pani nikalne ki speed jyda hai borewell pe pani recover karne ki tulna me
Bhai mera 0.5 hp openwell submersible pump main 20mfd capacitor laga hua hai voltage thoda kam reheta hai or pump late main pani uthata hai kya main 20 mfd ko change karke 25 mfd ka laga sakta hoon
@@ravinderchoudhary1976 aapke pass jitne feet ka borewell hai usme normally 40-50 feet chor ke submersible install kijiye Or kuch kuch special case me dekhna padhta hai tab tay ho pata hai ki kitne feet me submersible ko hona chahiye
Hamare yaha isi mahine bore hua hai usme abhi water level down hai kam pani aata hai 20 min mushkil se chalti aur phir bore dry ho jata hai or recharge hone me bhi bohot time lagta hai kya uska water level increase ho ga baad mai
Bhai jindal 1.5 hp single phase submersible 350ft paani puush nahi kar pa rahi hai, voltage 180 aa raha hai, kaunsa stabilizer sahi raha?? Aur kitne kva ka, aur prce kya hogi??
@@Easy_fit stage ka pata nahin lekin 1 month se voltage drop hua hai jab se problem hai. Submersible on condition me 220 volt aata hai tab theek se kaam karta hai
Hamara bore to thik hai par jab pani ko pahar pe chadana hai to nhi hota pani wapis aata hai.... ////// Motar 2hp.ka hai and bore410 Bore me pani 80 fit pe hai or motar 300 pe autara hai ... Reply me
Hamara borewell approx 90 feet hai aur submersible pump 0.75 Hp ka hai aur building over tank height approx 60 feet hai with pipe line , pahele suruaat me barabar Pani ata tha abhi 15 din se pressure nahi milta usi karan se tank bharta nahi hai capasitor bhi change Kiya mechanic ne aakar pump khoolkar check bhi Kiya lekin problem solve nahi ho raha hai aap suggetion dijiye
Bhai , 590 pe pani laga tha , and 630 tak drill kiya tha , because red matti ayi thi .,summer mein ,kiya tha , now borewell is at 585 ,texmo , 2 hp 30 stages ki , starting mein pani force se aya but after 3-4 days , speed reduced , and now low speed k sath sath , motor is getting dry after half an hour , kindly guide , wat to do ..? Motor problem or water is dry . Borewell k pass 10 feet side me 8 feet ka , khada hai waha continue water jama ho raha hai continuously ,, may be because of rainy season ,, but still water is continuously coming for 3 months ,, waha bore well dala chahiye ??
Bhai humne 120 foot mare the boring Pani nahin nikala tha bad mein usmein Pani nikala hai to ham bada wala samarsebal lagaye Hain to unlimited mujhe Pani nahin mila hai thoda mila hai tum mujhe Ruk Ruk kar chalana padta hai uske liye koi aapke pass hai to solution bataiye please 🥺
Hamari society me ek bor hai 3hp ki wo 200 se 300 ft niche hai. Wo kabhi kaam pani deti hai aur bhut bar trip hojati hai. Kya reason hai ?? Aur 3hp ki motor ko kitna voltage lagta hai.
sir ji ek dikaat aa rhi hai jab hum apna tank bhar dete hai fir summersable band kar dete hai thodi der baad pura tank khali ho jata hai na hi kahi se pani out ho reha mtlb summersabable pani wapad kich reha hai any solution
Sir mera 250 par samarshebul hai 4 se 5 chalne ke baad pressure kam ho jata hai aur samarshebul chalu karne ke baad thoda sa balu deta hai please help sir
Bhai phele 10-12min full pressure ate hai fir pani ka pressure kam Hoo jate hai ..pr kabhi pani borewell mai khatam nhi hota kya karen hai? Low pressure hone ka
Pehle 12 min full pressure se Esliye aata hai kyu ki us time pani upper rehta or submersible ka niyam hi hai jitna pani upper hoga utna speed se pani aayega Or jab pani dhire dhire niche jayega to speed kum hote jayega Submersible ke yeah chiz Common hoti don’t worry aapka motor sahi 👍 hai
मेरा बीर 55 फिट हे..लोहे की 4"इंच की पाइप हे..v4 का सबमर्सिबल पंप जाता नहीं हे..v-3 का पंप डालना पड़ता हे..9' फिट पर पानी हे..ओर टैंक पहले मजले पर 23 फूट पर 1000 लीटर की टैंक हे..सबमर्सिबल पंप को छोड़ कर कौनसा पंप लगाना चाहिए..आप सलाह दे......
Koi bhi mono block pump use kijiye ga 28 feet jyda neeche se pani utha sakega Aise aapke borewell me 9 feet ke bad pani Mtlb 19 feet ka pani se 1000L pani kaha se bhar sakega
1 hp का 10 steg मोटर है 100 feet पर डाला है नया बोरिंग किया है 170 volte कंरंट पर पानी बहुत कम दै रहा है। क्या स्टैपलाइजर लगायै। या मोटर मै खराबी है 60 feet water level है यहां 100 feet पर मोटर डाला है। प्रैशर बिल्कुल कम है।
Bhai hamare pass jindal ka 1hp ka submersible pump hai or boring ki motor 110 foot par hai lekin aab kuch time se paani ka pressure fluctuate kar rha hai even jab voltage constant hai( normally hamare yahan voltage 180 se 200 ke bich hota hai) iss problem ka reason kya hai or solution kya hai
Motor ampere kitna le rhi hai sath me kitne der tak pressure sahi aata hai Pressure down hone ke bad ampere kya le raha Motor kitne feet pe install hai
Motor 110 ft par hai, motor start karne ke sath hi pressure kabhi kam or kabhi jayada hone lagta hai, submersible board mei normally jo ampere reading aati hai abhi bhi vohi aa rhi hai. Ampere fluactuate nahi kar rha
Voltage too constant hi hai show ho rha lekin voltage 180 se 200 ke bicha rehta hai , or subah pani sahi pressure se aata hai lekin sham ke waqt pressure kam jyada ho rha hai
Bhai maine kal new summersable daali hai lekin usme 10 sec hi aata hai paani fir nahi aata summer chalu rahi hai tirupati ki summer hai 3000 ka liya tha borring 60 foot hai aur 55 foot par maine summer dalwaya hai
Bhai meri submersible mai kareeb10 minutes mai Pani uthar hai fir kareeb 10-15 minute bahut kam pani ata h fir use baad pura pani hota h maine startor dekha tha to uska jo starting wala capacitor tha vo bilkul damage ho gya tha to mai market se naya starter hi le aya usme sirf ek capacitor hai ,startor change karne ke baad bhi wahi problem hai
Bhai humne 660 ft borewell karwaya hai 20-25 ft ke baad se bas ek hi safed pathar pura 660ft tak puraa nikklaa ... Par ek bund bhi pani nahin niklaa ... Toh udaas ho ke drilling band karwadi ... Or 10 din bad dekha toh 20-25 ft niche pani hai toh sawal ab- Kitna HP kaa motor or Kitna stage ka or kounsi compny ka lagaye or kitne ft par lagaye motor ... Or motor ka price lag bhag kitna aayegaa ....? Plz rply .......
2 hp 30 stage submersible texmo ko 600 feet me laga dijiye dheere dheere ekdum pani 💧 mil jayega agar 4 inch se upper ka borewell hai to 600 feet texmo ko lagaye hai waha bhi pani nahi nahi mila tha uska video channel me hai
Bhai mere ghr ka summersible m rait aati h or ab dheere dheere pani deta h kabhi bohot tez to kabhi bohot dheere dheere beech beech m pani deta hi nhi h isko kaise theek kr skte h
Bhaiya meri boring 380ft ho rakhi hai or motor 310 ft per hai, jb motor chalu karo to amp meter 14-15 jaa rha tb pani ata hai phir 10-15 sec baad amp meter 10 pe aa jata hai or phir pani nhi ata, phir 5 min k baad phirse se 10-15 sec k liye paani ata hai phir chala jata hai Motor 1.5hp ki hai
Humari motor 5 -6 sec chalte hai pani upper aana ka sound bhi aata hai fir motor work karna stop kar dati hai jab chalti hai tab 5amp par hoti hai band hona par 10 ho jati h or voltage toh sahi h
Kuch din phale he Chapacitor change kiya tha, subha tak achi chal rahi thi achank sa hui, borewall mai pani bhi bhut jada nhi hai par aata hai, subha ek bucket dirty pani bhi aaya tha fir thik aaya tha
सर जी पूरा बोरवेल 680 फीट और पानी 580 पे लगा हुआ हा बोरवेल में 7.5 (20) स्टेज 6 नोजल ही फेक रेहा हा पानी पूरा 24 घंटे चलता हा पानी में कोई टूट नहीं हा कोई उपाय बताए काहा या कितने फीट पर मोटर होनी चाहिए
भाई साहब, मन में एक सवाल आया है यदि 1 एचपी समोटर को 5 कॉलम पाइप में जोड़ कर लटकाया जाए मतलब 15 मीटर नीचे लटकाया जाए और पानी को जमीन से 15 मीटर ऊपर रखे 1000 लीटर के टैंक में चढ़ाया जाए तो टैंक 7 स्टेज वाली मोटर से ज्यादा जल्दी भरेगा या 10 स्टेज वाली मोटर से??? किसका डिस्चार्ज रेट ज्यादा होगा?? मोटर को fix 230 वोल्ट की सप्लाई मिल रही है मतलब वोल्टेज का कोई issue नहीं है।
Aapka sawal ekdum sahi hai 7 stage wali motor ka speed jyda hoga kyuki Jitna stage kum hoga utna speed jyda hoga Stage badh jane se speed kam ho jata hai par borewell me jyda se jyda niche se upper pani laane ka power badh jata hai par speed kum rehta hai
Pipe leakage ho ga Borewell se bahar pani aaa bhi raha hai ya nahi Ya sirf ground floor me pani aa raha hai or ground floor se upper nahi jaa raha hai ?
Bro Hamari samarsebal motor pahle pressure se Pani Aata Hai FIR slow hokar pani Band Ho Jaati Hai FIR 3 ghante bad Pani Aata Hai borvel wale Kahate Hain level kam hai Bina check kiye 3 Sal se Yahi problem hai Kitni bhi Barish aaye to 5 minut bhi Pani Nahin badhta kya Karan ho sakta hai bhai
Sir mera 250 par samarshebul hai 4 se 5 chalne ke baad pressure kam ho jata hai aur samarshebul chalu karne ke baad thoda sa balu deta hai please help sir
आपका बहुत बहुत धन्यवाद सर जी.
🙏🙏🙏🙏👍
Sir kya hum vfd ko stabliser ke rup me use kr skte hain. Submersible ke liyeeee
बहुत अच्छा लगा भाई साहब
Bhaiya 5inch bor me 1.50hp ka usa company ka pump lagaya ho bilalul kam ara he to isaka salusan kya he thoda reply kijiye pls bhaiya
1.5 hp ka submersible okay
Par kitna stage ka hai ??
Or kitne feet niche lga rakhe hai ??
Submersible on karne ke bad voltage kitna rehta hai or on karne se pehle kitna tha ??
Submersible on karne ke bad AMP kitna rehta hai ??
Bhai mera borewell (8")700 5:06 ft ka hai...bore karne samai 60 ft mai pani aya tha..fir last tak nhi aya..bad me dekhe to 10 ft niche pani hai....ismi kon sa pump lagane se sahi rahega jisme minimum 1hr pani milega for cultivation 🙏
Ghar ke liye ya kheti ke liye ???
Sir new bor kray texmo motar lgaya pani me matti ara or preshar bhi kam he kya kre
@@manohartalreja8019 submersible ko 10 feet upper kijiye
@@Easy_fit kheti ke liya
Achcha Laga❤❤🎉❤
जय हिन्द जय भारत
पम्प से वोल्टेज ड्रॉप नही होते बल्कि सिस्टम से वोल्टेज आते ही कम है,, बाकी लोड़ पर कुछ वोल्टेज ड्राप होना तो आम बात है,, जो कोई बड़ी समस्या नही है। बड़ी समस्या है ट्रांसफॉर्मर से वोल्टेज कम आना।
Transform se hi low voltage aana ya lord dene se voltage down hona dono se ek hi chiz hota hai pressure me kami 👍
Borwell 550 feet pe pani diya hai , kitne hp ka motor lagana chahiye, aur kitna feet pipe dalna chahiye ❤
Total borewell kitna hai or lagta hai aapke borewell me pani kum hai ???
3hp 40stage
@@Easy_fit 740 feet
@@gulshansahu4608 three phase line use karte hai ya single phase???
@@Easy_fit single
Hamara bore 350 feet hai or motor 300 foot pr hai 1 HP ki motor hai or pani sirf 20-25 min aata hai pani kam aata hai or pressure low rehta hai thoda bhut or voltage on krne se phle 220 rehta hai or on krne ke baad 200 ho jata hai
Ap kuch solution batao is cheez ka
Sab thik to hai aapka 20-25 min ke bad borewell dry ho raha hai Esliye pressure down ho jata hai
Thank you@@Easy_fit
2 hp ki motor lagao
Kya 2 hp ki submersible 1 hp ke sthan par lagane se pressure bath jayega. Kripya batayen maine bhi 1 hp pump lagaya hua hai
Sir. Mere.simersible 1hp ka hai . Aur curent 5 ampere bta rha phir bhi pani bhout slow aata hai to kya kre
720 feet borewell..
Water level.. 20feet..
Motor level 380feet
3hp.. 23stage..
Water output 1hour pressure
After 1hour pressure slow
Motor 1minute off-on.. Water comes in good pressure..
What is the reason..
Solution please...
Any problem of silt.. Mud.. Blocking the filter mesh??
Pump is in the water 200feet below..
But pressure becomes low... Whats the reason
I think Borewell me pani dry ho rha hai
4 inch bore me v4 submersible pump wali video chahiye pls...
humne haal hi me V4 pump dala hain aap usko dekh sakte ho
410ft boarwell hai bhai 4.5 inch kitna stage lagega
2hp 20 stage
2 hp का मोटर सिंगल फेज लाइन चल जायेगा क्या सर @@Easy_fit
@@leshsahu9877 ekdam chal jayega
total 600 ft gaya haie summer toda kama hata hai now meter mai starting 13.6 13.4 and 13.2 and 10.6 hoa gaya already 4 years hoa gaya hai what problem hai please tell me sir.
Submersible kitna feet me install hai ??
सर जी पूरा बोरवेल 680 फीट और पानी 580 पे लगा हुआ हा बोरवेल में 7.5 (20) स्टेज 6 नोजल ही फेक रेहा हा पानी पूरा 24 घंटे चलता हा पानी में कोई टूट नहीं हा कोई उपाय बताए काहा या कितने फीट पर मोटर होनी चाहिए
Hvkgkgjqosgoftfy
Video achha he miri pump me 2 sall se 34vminit lagta he tanke bharne me 750 ltr ka he. Pehle 12 minit me bhar jata tha. Kala kal Pani bhi ata he keya problem ho sakta he
Submersible nikal ke saaf kijiye
Ok kal bulta hun boring vale bhai ko. Baad me aapko bolunga Keya problem huva he
Bhai Hamare Ghar pae Abhi Boring Hua Pani Bahut kam a rha he ruk ruk ke
Kya Boring Me pani Kam he
Please Reply
Kitne der pani sahi ata hai
2 minute
Sir hamara 10 hp motar 10 stage ka pump hai or 650 fit par hai jab start karte he to adha khanata full pani deta hai fir kam ho jata eksa kya problem hoga please reply
Answer
@@niteshrathva34 yeah submersible ki problem nahi hai 100%
Problem hai borewell ke water source ki 30 min ke bad pani borewell dry hone lag rahi hai Esliye pressure down hota chala jayega
Kyuki submersible ki pani nikalne ki speed jyda hai borewell pe pani recover karne ki tulna me
Thank you sir
Ye kitna inch pani he jo chal rha
1 inch
Help me new summersable hai 1 manth hua lagaye pressure nhi aa raha ampear kam aa raha voltage thik hai
Kitna hp or stage submersible pump hai ?
Total borewell kitna feet hai ??
@@Easy_fit 1 hp ka hain start karne par voltas 100 Tak AA ja raha hain
@@toprahulop voltage ko sudhariye
Aapke yaha low voltage problem hai stabiliser use kijiye
Kaisa wire ka use kiye hai channel ke about me whatsApp number ho ga usme video bana k send kijiye pani ka aur penal ka
560 par 12.5 13stage he Kam Pani de rahi he
Bhai mera 0.5 hp openwell submersible pump main 20mfd capacitor laga hua hai voltage thoda kam reheta hai or pump late main pani uthata hai kya main 20 mfd ko change karke 25 mfd ka laga sakta hoon
Bhai hum kog ka bore 350 feet hai pipe 320 feet hai motore 1.5 hp ka lga hai pressure kam aata hau kya karen voltage 12se 13A k bich rahta hai .
Amp jyda hai aapka submersible me
Motor on karne ke bad voltage kitna show karta hai ?
Wire kitna mm use kiye hai ??
Bro 190v hai or amp 14 350feet 1.5hp ki moter he pressure kese badaye@@Easy_fit
Sir motor km se km kitni feet pani m rkhni chaiye
@@ravinderchoudhary1976 aapke pass jitne feet ka borewell hai usme normally 40-50 feet chor ke submersible install kijiye
Or kuch kuch special case me dekhna padhta hai tab tay ho pata hai ki kitne feet me submersible ko hona chahiye
1hp motor ke liye kitane kv ka stabilizer lagega
Max to max 3kv bahut hai
Sir 1.5 hp motor kitne ka capesitor lagna chahiye
Oil wale ka ya water wale ka
@@Easy_fit water vale ka
@@mukesh.baria74 120-150 starting running 72 mfd
Hamare yaha isi mahine bore hua hai usme abhi water level down hai kam pani aata hai 20 min mushkil se chalti aur phir bore dry ho jata hai or recharge hone me bhi bohot time lagta hai kya uska water level increase ho ga baad mai
6 inch se upper ka borewell hai to jarur hoga 6 inch se kum hai chance kum rehta hai
Bhai jindal 1.5 hp single phase submersible 350ft paani puush nahi kar pa rahi hai, voltage 180 aa raha hai, kaunsa stabilizer sahi raha?? Aur kitne kva ka, aur prce kya hogi??
Kitne stage ka hai suru se hi ye problem thi ya abhi suru hua
@@Easy_fit stage ka pata nahin lekin 1 month se voltage drop hua hai jab se problem hai. Submersible on condition me 220 volt aata hai tab theek se kaam karta hai
3kv ka stabilizer le lijiye
@@Easy_fit kaunsa aur kahan se le ??
Copper me lijiye aur auto aur manual dono hona chahiye apne market se le lijiye jo achha rakhta ho
Good advice
Tq
Hamara bore to thik hai par jab pani ko pahar pe chadana hai to nhi hota pani wapis aata hai....
//////
Motar 2hp.ka hai and bore410
Bore me pani 80 fit pe hai or motar 300 pe autara hai
...
Reply me
Pahar jada aucha bhi nhi hai par pata nhi q
Jra clear aasan tarika me bataiye taki ache se samjh sake
Hamara borewell approx 90 feet hai aur submersible pump 0.75 Hp ka hai aur building over tank height approx 60 feet hai with pipe line , pahele suruaat me barabar Pani ata tha abhi 15 din se pressure nahi milta usi karan se tank bharta nahi hai capasitor bhi change Kiya mechanic ne aakar pump khoolkar check bhi Kiya lekin problem solve nahi ho raha hai aap suggetion dijiye
@@vatsabhatt6455 runing capacitor ko check kijiye submersible ke pump ko check kijiye pani cheak kijiye
Sir मेरे घर में 250feet बोरिंग है और 90 feet में पानी आया था और 200फीट नीचे मोटर लगानी है और 1 hp taro texmo moter में कितनी स्टेज का पंप लगाना चाहिए
1 hp 15 stage lga dijiye
Bhai , 590 pe pani laga tha , and 630 tak drill kiya tha , because red matti ayi thi .,summer mein ,kiya tha , now borewell is at 585 ,texmo , 2 hp 30 stages ki , starting mein pani force se aya but after 3-4 days , speed reduced , and now low speed k sath sath , motor is getting dry after half an hour , kindly guide , wat to do ..?
Motor problem or water is dry .
Borewell k pass 10 feet side me 8 feet ka , khada hai waha continue water jama ho raha hai continuously ,, may be because of rainy season ,, but still water is continuously coming for 3 months ,, waha bore well dala chahiye ??
@@tushar44p borewell me pani dry ho jaa raha hai motor sahi hai
Or agatar use karne se 1-2 saal me yeah thik ho jane ka chance hota hai khudh se
Bhai mera bor 40 fit ha or 1hp ki motar ha panni 2 mint shi aata ha baad me paresar bilkul km ho jata ha kya kary
40 feet ke bor me pani jaldi jaldi dry karega tab pressure bhi down hoga
Bhai humne 120 foot mare the boring Pani nahin nikala tha bad mein usmein Pani nikala hai to ham bada wala samarsebal lagaye Hain to unlimited mujhe Pani nahin mila hai thoda mila hai tum mujhe Ruk Ruk kar chalana padta hai uske liye koi aapke pass hai to solution bataiye please 🥺
Kitna hp or stage ka submersible lagaye hai ??
Kitna feet me submersible ko lagaye hai ??
Sir ..360 feet bor hai ...or singal face motor hai ..avi 8 dino se pani bilkul kam ara hai
New submersible laga hai ??
Borewell me kitna inch pani mila tha ??
Kitna hp or kitne stage ka submersible hai ??
1 hp ka motor ha 12 stage ka or volatage v 18 se 19 ka rehta ga 180 feet pe submersible lagaye ha paani kam deta ha ky karan ha
Sorry bhai par Voltage sahi se bataiye 18 se 19 koi voltage nahi hota hai
500 fit pe dalne ke liye kitne stages aor hp ka Samasebul chahiye
kheti ke liye ya gharelu use ke liye
Single phase submersible me kum se kum 2 hp 30 stage
Mera motar hai 4 char tala par pani nahi phuch rahay Keya kre
Kitna hp or kitna stage ka motor hai ???
380 par samar fit hai red wala switch bar bar jal jata motor bhi par par jal rahi koi wajha bataye
Wire garam ho raha hoga change kijiye
Hamari society me ek bor hai 3hp ki wo 200 se 300 ft niche hai. Wo kabhi kaam pani deti hai aur bhut bar trip hojati hai. Kya reason hai ??
Aur 3hp ki motor ko kitna voltage lagta hai.
Single phase hai ?
3 phase ka hai. Aur abhi society walo ne 4hp ki motor Dali hai. Dono ke liye kitna voltages use hoga please rply
380 se 420 me hona chahiye
sir ji ek dikaat aa rhi hai jab hum apna tank bhar dete hai fir summersable band kar dete hai thodi der baad pura tank khali ho jata hai na hi kahi se pani out ho reha mtlb summersabable pani wapad kich reha hai any solution
Submersible me borewell ke bare wale pipe me NRV non return valve lga dijiye
Sir mera 250 par samarshebul hai 4 se 5 chalne ke baad pressure kam ho jata hai aur samarshebul chalu karne ke baad thoda sa balu deta hai please help sir
@@SHIVAM9931KUMAR kitna feet ka borewell hai and kitne feet me install hai submersible
@@Easy_fit 240 fit pr borewell hai 70 fit pr install hai
@@SHIVAM9931KUMAR new borewell hai ?
@@Easy_fit ha
@@Easy_fit 4 months ho gaya
Bhai phele 10-12min full pressure ate hai fir pani ka pressure kam Hoo jate hai ..pr kabhi pani borewell mai khatam nhi hota kya karen hai? Low pressure hone ka
Pehle 12 min full pressure se Esliye aata hai kyu ki us time pani upper rehta or submersible ka niyam hi hai jitna pani upper hoga utna speed se pani aayega
Or jab pani dhire dhire niche jayega to speed kum hote jayega
Submersible ke yeah chiz Common hoti don’t worry aapka motor sahi 👍 hai
@@Easy_fit thankyou bro
Bhai Mera bi same problem...beech beech me slow se aata hai fir speed se ....kya pump ko or niche tak dalne se ye sahi hoga kya ?
@@som9681 nhi hota bro mene kr rha hai😅
मेरा बीर 55 फिट हे..लोहे की 4"इंच की पाइप हे..v4 का सबमर्सिबल पंप जाता नहीं हे..v-3 का पंप डालना पड़ता हे..9' फिट पर पानी हे..ओर टैंक पहले मजले पर 23 फूट पर 1000 लीटर की टैंक हे..सबमर्सिबल पंप को छोड़ कर कौनसा पंप लगाना चाहिए..आप सलाह दे......
Koi bhi mono block pump use kijiye ga 28 feet jyda neeche se pani utha sakega
Aise aapke borewell me 9 feet ke bad pani Mtlb 19 feet ka pani se 1000L pani kaha se bhar sakega
Bhai 175 foot p bor hy or motor 135 foot p lgaya is c motor ko nuksan to nhi hota
Nhi bas bina pani ke on mat rehne dijiye ga
Mere bhai mai problem ko samjhao jo aap bol rahe aisa ni hai falkon ki moter ko satah se 15 fit ki duri se chala sakte hai
Kya ho gya ??
Bhai pressure kam ho gya hai or tanki tak paani chhat par nahi jaa rha hai kya dikkat ho sakta hai
Kitna hp - stage ka submersible hai or kitna feet me install kiye hai ??
1 hp का 10 steg मोटर है 100 feet पर डाला है नया बोरिंग किया है
170 volte कंरंट पर पानी बहुत कम दै रहा है।
क्या स्टैपलाइजर लगायै।
या मोटर मै खराबी है
60 feet water level है यहां 100 feet पर मोटर डाला है।
प्रैशर बिल्कुल कम है।
@@AryashMishra-ps2nb submersible ko or niche kijiye or low voltage hai stabilizer lagana hoga
Painal se jo taar h moter tk usko sahi chune jisme 56 taar ka hona jruri h
Hp ke hisab se !!!
@@Easy_fit hp jo bhi ho asli pechan taar ki h vo droop ni krega bijli ko
@@Easy_fit pani km ana tar kmjor hona bhi ho skta h
Bhai hamare pass jindal ka 1hp ka submersible pump hai or boring ki motor 110 foot par hai lekin aab kuch time se paani ka pressure fluctuate kar rha hai even jab voltage constant hai( normally hamare yahan voltage 180 se 200 ke bich hota hai) iss problem ka reason kya hai or solution kya hai
Motor ampere kitna le rhi hai sath me kitne der tak pressure sahi aata hai
Pressure down hone ke bad ampere kya le raha
Motor kitne feet pe install hai
Motor 110 ft par hai, motor start karne ke sath hi pressure kabhi kam or kabhi jayada hone lagta hai, submersible board mei normally jo ampere reading aati hai abhi bhi vohi aa rhi hai. Ampere fluactuate nahi kar rha
@@ABHISHEKSINGH-yw2jl voltage kaisa reh raha hai ??
Voltage too constant hi hai show ho rha lekin voltage 180 se 200 ke bicha rehta hai , or subah pani sahi pressure se aata hai lekin sham ke waqt pressure kam jyada ho rha hai
Pani niche gya
Bhai maine kal new summersable daali hai lekin usme 10 sec hi aata hai paani fir nahi aata summer chalu rahi hai tirupati ki summer hai 3000 ka liya tha borring 60 foot hai aur 55 foot par maine summer dalwaya hai
Kitna AMP le raha hai
Reply to do
@@Easy_fit please give me your contact no 240
@@Banty-hu8en ampere bataiye kitna le raha hain
@@Easy_fit ampiure to sahi aa raha hai 240 hai shayad
Bhai meri submersible mai kareeb10 minutes mai Pani uthar hai fir kareeb 10-15 minute bahut kam pani ata h fir use baad pura pani hota h maine startor dekha tha to uska jo starting wala capacitor tha vo bilkul damage ho gya tha to mai market se naya starter hi le aya usme sirf ek capacitor hai ,startor change karne ke baad bhi wahi problem hai
10 min speed se chalta hai phir pani ka speed down ho jata hai 10-15 takk
Bhai Mera new bore hai uska safai nhi hua hai abhi phle submersible jyada Pani deta hai aab Kam de rha hai
Kitna time takk pressure me deta hai ? Kitna din huwa hai lagaye huwe ?
Kitna inch pani mila tha ?
Bhai humne 660 ft borewell karwaya hai 20-25 ft ke baad se bas ek hi safed pathar pura 660ft tak puraa nikklaa ... Par ek bund bhi pani nahin niklaa ... Toh udaas ho ke drilling band karwadi ... Or 10 din bad dekha toh 20-25 ft niche pani hai toh sawal ab-
Kitna HP kaa motor or
Kitna stage ka or kounsi compny ka lagaye or kitne ft par lagaye motor ...
Or motor ka price lag bhag kitna aayegaa ....? Plz rply .......
2 hp 30 stage submersible texmo ko 600 feet me laga dijiye dheere dheere ekdum pani 💧 mil jayega agar 4 inch se upper ka borewell hai to
600 feet texmo ko lagaye hai waha bhi pani nahi nahi mila tha uska video channel me hai
3 फेज stabliger की क़ीमत
Bhai mere ghr ka summersible m rait aati h or ab dheere dheere pani deta h kabhi bohot tez to kabhi bohot dheere dheere beech beech m pani deta hi nhi h isko kaise theek kr skte h
Kitha feet ka bor h aur motor kithe feet. Me hai ky motor k filter m kuch alg se diye the kya bina pani ke pump ko to chalaye nhi na the
Bhaiya meri boring 380ft ho rakhi hai or motor 310 ft per hai, jb motor chalu karo to amp meter 14-15 jaa rha tb pani ata hai phir 10-15 sec baad amp meter 10 pe aa jata hai or phir pani nhi ata, phir 5 min k baad phirse se 10-15 sec k liye paani ata hai phir chala jata hai
Motor 1.5hp ki hai
Kitna din hua borewell huye
Humari motor 5 -6 sec chalte hai pani upper aana ka sound bhi aata hai fir motor work karna stop kar dati hai jab chalti hai tab 5amp par hoti hai band hona par 10 ho jati h or voltage toh sahi h
Kirne hp ka hai ho skta hai uska capacitors kharab ho gya ho koi aur penal laga ke try kijiye
Kuch din phale he Chapacitor change kiya tha, subha tak achi chal rahi thi achank sa hui, borewall mai pani bhi bhut jada nhi hai par aata hai, subha ek bucket dirty pani bhi aaya tha fir thik aaya tha
Insta me DM kijiye
Thanks for your reply but we called for repair
Bhai mera moter 5minute chalta hai or band ho jata hai kiya kare
Sar Mere motor Pani uthata hi nahin motor bhi theek hai niche Jameen Mein Shayad Pani hi Nahin Hai To Pani Upar Aata hi nahin Kya Karen
Aap humko Instagram me msg kijiye waha baat karte hai
सर जी पूरा बोरवेल 680 फीट और पानी 580 पे लगा हुआ हा बोरवेल में 7.5 (20) स्टेज 6 नोजल ही फेक रेहा हा पानी पूरा 24 घंटे चलता हा पानी में कोई टूट नहीं हा कोई उपाय बताए काहा या कितने फीट पर मोटर होनी चाहिए
Pani me koi tut nahi hai
Yeah samjh nahi paye ???
@@Easy_fit matlab paani regular 24 ghanta chalata ha paani Kam nahi hua ha lakin pressure Kam de reha ha
@@ankitnagwa6282 kuch time ke bad to pressure down to hoga gi
@@Easy_fit sir ye btao aap ab me motor kitne feet pe fit karu
भैया pump चालु बंद करने पर ऊपर का हिस्सा घूम रहा है क्या करे
Kon sa hissa
@@Easy_fit upar ka hissa jaha se paani nikalta hai
Steel ka jo cylinder jaisa rehta h vo ghum raha hai ya jo head outlate h vo
@@Easy_fit bhiya niche pump se leke sare pipe ghum ja raha hai
😅😅 apka to pura system hi ghum raha hai
6201150992 isme video bana k whatsApp kijiye
पानी से बदबू आए तो क्या करें मोटर डाले 20दीन हो गया
10 feet upper kar dijiye motor ko or dhyaan rahe ki borewell ke aas pass koi ganda pani jana na ho
Ok
Pump chalu krne pr thodi der pani aata h phir andr hwa khinchta h
भाई साहब, मन में एक सवाल आया है
यदि 1 एचपी समोटर को 5 कॉलम पाइप में जोड़ कर लटकाया जाए मतलब 15 मीटर नीचे लटकाया जाए और पानी को जमीन से 15 मीटर ऊपर रखे 1000 लीटर के टैंक में चढ़ाया जाए तो टैंक 7 स्टेज वाली मोटर से ज्यादा जल्दी भरेगा या 10 स्टेज वाली मोटर से??? किसका डिस्चार्ज रेट ज्यादा होगा??
मोटर को fix 230 वोल्ट की सप्लाई मिल रही है मतलब वोल्टेज का कोई issue नहीं है।
Aapka sawal ekdum sahi hai
7 stage wali motor ka speed jyda hoga kyuki
Jitna stage kum hoga utna speed jyda hoga
Stage badh jane se speed kam ho jata hai par borewell me jyda se jyda niche se upper pani laane ka power badh jata hai par speed kum rehta hai
@@Easy_fit जवाब के लिए धन्यवाद 🙏
क्या इसका मतलब ये हुआ कि 7 स्टेज का डिस्चार्ज रेट 10 स्टेज के पंप से ज्यादा होगा???
Meri motor 2.25 amp le rahi h paani nhi aa raha???
Wire check kare
Mere bhai upar niche karne se problem solve ni hogi
Sab ki condition v ek nhi hoti
ज्यादा एम्पिएर लेने का मतलब क्या है
Single phase me agar jyada ampere le to pump over load me chal raha h
Aapka no chahiye hum bahut paresaan h pani ruk ruk kr aata h
About me hai
Mast
Last tak dekha 😂
Thanks
Bhai ampere drop hoo raha haa
Kitne hp ka motor hain
Pani chala hi pani girne lagta hi upar nahi jata hi tanki main
Pipe leakage ho ga
Borewell se bahar pani aaa bhi raha hai ya nahi
Ya sirf ground floor me pani aa raha hai or ground floor se upper nahi jaa raha hai ?
Suru m to pareser htta h fhir bad m kam ho jatha h
Kitne time k bad kam hota hai ?
Very low pressure
Bro Hamari samarsebal motor pahle pressure se Pani Aata Hai FIR slow hokar pani Band Ho Jaati Hai FIR 3 ghante bad Pani Aata Hai borvel wale Kahate Hain level kam hai Bina check kiye 3 Sal se Yahi problem hai Kitni bhi Barish aaye to 5 minut bhi Pani Nahin badhta kya Karan ho sakta hai bhai
Very bad pressure
Our main reason for decrease in pressure is crack in pipe or nipple
भाई आप अपना नम्बरदो
intsa me dm kijiye
Insta id kaha ha bhai aapka
Sir mera 250 par samarshebul hai 4 se 5 chalne ke baad pressure kam ho jata hai aur samarshebul chalu karne ke baad thoda sa balu deta hai please help sir