    @indranilbal9507 ปีที่แล้ว +1

    If it is a structural wall, I have to check punching for wall too.. but in that case column punching is showing only.. how to check punching for walls?

    • @civilconst
      @civilconst ปีที่แล้ว +1

      For the wall, you have to check one-way shear only not punching shear.

    • @indranilbal9507
      @indranilbal9507 ปีที่แล้ว

      @@civilconst sir, One thing I noticed while importing base reaction from etabs to safe that, in case of shear wall, a beam is imported with same thickness of shear wall having a depth equal to the height of bottom most story in etabs. What to do with that beam while designing foundation in SAFE? Should I keep that beam?