In relay say q ya masla hal howa basic reason keya hay kay meter kay lights on ho jaty hay Aur in relay ka role keya hay Kindly is ko explain karay takay ya fault sub logo kay samj may aja ya. Kay reason keya hay meter kay lights q on hoty hay Thanks
Brother 1st off All me as circuit ko already mein explain kar chuka Hun video aap gaur se dekhen........plzzz. Is relay ka basic reason yah hai k in case aapke wapda ke meter per ya phr aapke solar inverter mein interly koi problem aa rahi hai jiski repairing mein bahut zyada kharcha aur bahut zyada time lagega to us problem se bachne k lye as circuit se aap Bina Apna energy meter aur Bina Apna inverter replace kiye hue hua Apna meter ka earth ur reverse light ka fault remove kar sakte ho jaza k Allah
Bhai just light night ko on hoti Hy tu aska koi issue ni Hy phr be ap inverter ki 16 number setting me Jai ur setting (OSO) kren Yani wapda se battery charge na kren setting only solar kren problem solve ho jaiga
@@Electromech_EMAssalam Alaikum Sir. Mairay ghar par 2.4 KW ka system install hai. Summer main to bohat acha raha. Ab winter main jab electric heater lagaya to 2 problems hain 1- Earth light on hoti hai 2- Raat main wapda par shift honay kay bawajood battery bhi consume ho rahi hoti hai. Main nai inverter kee settings SBU or charging OSO rakhi hoi hai Plz help
اسلام وعلیکم میرے پاس سنگل فیز انورٹر ہے۔ اس میں اف گرڈ اور آن گرڈ کی دونوں سہولتیں ہیں۔ جب میں واپڈا شیئرنگ کے لئے ہائی برڈ پرسیٹنگ کرتا ہوں تو انورٹر میٹر کی طرف بجلی بنا کر بھیجنا شروع کر۔دیتا ہے اور میٹر وہ تمام یونٹس مجھے چارج کرتا ہے۔ کیا میں واپڈا اور انورٹر اوٹ پٹ کے درمیان ریلے لگا کر واپڈا کو بند کروا کر انورٹر کی اوٹ پٹ کو ہی انورٹر میں ان کروا دوں تو کیا انورٹر چلے گا؟
Great Sir ❤
Bhai me apna kam kar rha tha too mujy kish baat samj me nhi aarhe the ap ka video dekha to Mera me masla hal hogaya thanx brother ❤
Welcome bro
Zbrdst
I m interested. What are the charges for this circuit and how will our electrician incorporate this in our wiring?
Its installation is very easy just whatsapp me and I will guide you how to install it
In relay say q ya masla hal howa basic reason keya hay kay meter kay lights on ho jaty hay
Aur in relay ka role keya hay
Kindly is ko explain karay takay ya fault sub logo kay samj may aja ya. Kay reason keya hay meter kay lights q on hoty hay
Thanks
Brother 1st off All me as circuit ko already mein explain kar chuka Hun video aap gaur se dekhen........plzzz.
Is relay ka basic reason yah hai k in case aapke wapda ke meter per ya phr aapke solar inverter mein interly koi problem aa rahi hai jiski repairing mein bahut zyada kharcha aur bahut zyada time lagega to us problem se bachne k lye as circuit se aap Bina Apna energy meter aur Bina Apna inverter replace kiye hue hua Apna meter ka earth ur reverse light ka fault remove kar sakte ho jaza k Allah
Bhaee, agr sirf "Earth" ki light on hoti ho jeb Raat ko Wapda pe Battery charging start hoti hy. Teb kya solution hy?
Bhai just light night ko on hoti Hy tu aska koi issue ni Hy phr be ap inverter ki 16 number setting me Jai ur setting (OSO) kren Yani wapda se battery charge na kren setting only solar kren problem solve ho jaiga
@Electromech_EM Raat ko battery charge nahi kary gy to Garmi ki rato mai Battery end ho jaye gi.
@@Electromech_EMAssalam Alaikum Sir. Mairay ghar par 2.4 KW ka system install hai. Summer main to bohat acha raha. Ab winter main jab electric heater lagaya to 2 problems hain
1- Earth light on hoti hai
2- Raat main wapda par shift honay kay bawajood battery bhi consume ho rahi hoti hai.
Main nai inverter kee settings SBU or charging OSO rakhi hoi hai
Plz help
اسلام وعلیکم
میرے پاس سنگل فیز انورٹر ہے۔ اس میں اف گرڈ اور آن گرڈ کی دونوں سہولتیں ہیں۔ جب میں واپڈا شیئرنگ کے لئے ہائی برڈ پرسیٹنگ کرتا ہوں تو انورٹر میٹر کی طرف بجلی بنا کر بھیجنا شروع کر۔دیتا ہے اور میٹر وہ تمام یونٹس مجھے چارج کرتا ہے۔
کیا میں واپڈا اور انورٹر اوٹ پٹ کے درمیان ریلے لگا کر واپڈا کو بند کروا کر انورٹر کی اوٹ پٹ کو ہی انورٹر میں ان کروا دوں تو کیا انورٹر چلے گا؟
G bilkul chalega ap heavy relay Laga kr control kr skty hy
Price
Whatsapp plz