H3/AC3/AIO-H3 Meter Installation

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ส.ค. 2024

ความคิดเห็น • 35

  • @AndreasGoettsche
    @AndreasGoettsche 8 หลายเดือนก่อน +3

    Brilliant to produce a video that creates more questions than answers. What would it have been like to show the result to someone beforehand during production, before so many things were misrepresented.

    • @foxess5669
      @foxess5669  3 หลายเดือนก่อน

      Hello, we are so sorry if you still have lots of questions, but please feel free to send a message to service@fox-ess.com with a detail description of your request. Have a very good day.

  • @Ferdayssosa
    @Ferdayssosa ปีที่แล้ว +2

    I spoke to one of their techinician, they confirmed that, the smart meter will need to be installed after the house meter. It has to be between the house meter and Henley block if present.

    • @foxess5669
      @foxess5669  ปีที่แล้ว

      yep the location is correct.

  • @shakirzaidi2678
    @shakirzaidi2678 2 หลายเดือนก่อน +1

    I have 15 kw grid tied inverter installed at my home. It doesn't show load and grid consumption option on the app. Please guide if there's any settings issue or what I need to do? Thanks .

  • @erbse
    @erbse ปีที่แล้ว +4

    The AC plug has screw clamps and you have tighten the flexible wires without ferrules. Do you think this is professional work?

    • @foxess5669
      @foxess5669  3 หลายเดือนก่อน

      Thank you for your answer. If you still need more help please feel free to contact service@fox-ess.com with a detail description of your request. Have a very good day.

  • @2BmoreCrafts
    @2BmoreCrafts 2 ปีที่แล้ว +6

    At 1:50 you can see how cables from distribution box is being connected to Meter bottom (INPUT). And latter at 2:22 You can see that cables to distribution box is being connected to The plug that goes to Inverter. So its very confusing. When You connect Inverter at the bottom of Meter (INPUT) than Meter counts incoming electricity from a Grid as Exported. In this case Modbus might not work correctly. So this video by it self is very confusing and does not show how to connect Metter to Inverter, it only shows how to connect wires to plugs. :(

    • @MrDrVar
      @MrDrVar ปีที่แล้ว

      Agree

    • @foxess5669
      @foxess5669  ปีที่แล้ว

      Hi Martins, we got you and will soon make some progress regarding the meter wiring.

  • @mikem.5907
    @mikem.5907 ปีที่แล้ว +1

    Which side of the Smartmeter is connected to the converter? 1-4-7-or 3-6-9?

    • @foxess5669
      @foxess5669  3 หลายเดือนก่อน +1

      Thank you for your answer. If you still need more help please feel free to contact service@fox-ess.com with a detail description of your request. Have a very good day.

  • @blanchardmukanya8300
    @blanchardmukanya8300 4 หลายเดือนก่อน

    Hi Brother do u have a video that shows how to wire the 30 kw inverter 3phase

    • @foxess5669
      @foxess5669  3 หลายเดือนก่อน

      Hello @blanchardmukanya8300 Thank you for your message. All the videos are available on our YT channel, I invite you to check I am sure you will find a video for what you need. Have a great day.

  • @christopherlithgo2600
    @christopherlithgo2600 ปีที่แล้ว

    I have went from. Ac3 grid to top of meter. From bottom of meter to mcb in db. Is this correct its only giving out -20 - -40 w ? When charging it goes up to 8000w. Why is it discharging so low ?

    • @foxess5669
      @foxess5669  ปีที่แล้ว

      Hi Christopher, thanks for choosing Fox. May I have your email address, I will arrange our technical engineer to contact you shortly.

  • @christopherlithgo2600
    @christopherlithgo2600 ปีที่แล้ว

    Instead of this meter csn i just use 3 ct's ? If so how do i wire the plug up ?

    • @foxess5669
      @foxess5669  3 หลายเดือนก่อน

      Hello, thank you for your message. If you have still some questions, I adviced you to send an email to service@fox-ess.com with a detail description of your request (which products, series number, conditions of work...). Hope it will help. Have a nice day.

  • @volkergerbeth330
    @volkergerbeth330 ปีที่แล้ว

    Nach Inbetriebnahme zeigt die FusionSolarApp einen Fehler: Die Batterie ist offline. Kann es sein, dass die Entfernung zum SmartMeter zu groß ist und daher eine Fehleranzeige kommt?
    After commissioning, the FusionSolarApp shows an error: The battery is offline. Can it be that the distance to the SmartMeter is too large and therefore an error display comes?

    • @jog8184
      @jog8184 6 หลายเดือนก่อน

      Die Datenverkabelung ist nur bis 100 Meter zuverlässig. Größere Strecken müssen per Glasfaser verkabelt werden und dann an beiden Enden einen Umsetzer installieren, der das Lichtsignal wieder in Stromsignale (RJ45-Stecker) umwandelt.

    • @foxess5669
      @foxess5669  3 หลายเดือนก่อน

      Thank you for your answer. If you still need more help please feel free to contact service@fox-ess.com with a detail description of your request. Have a very good day.

  • @GJ-nt5li
    @GJ-nt5li ปีที่แล้ว

    Do you have any meter Indirect connection through /5A ratio current transformers?

    • @GJ-nt5li
      @GJ-nt5li ปีที่แล้ว

      I have a question, is the Fox T20 compatible with indirect meter measurement?

    • @foxess5669
      @foxess5669  ปีที่แล้ว

      Hi Sir, YES, we provide Meter+CT solutions; basically we only support the meter or CT authorized by FOX-ESS, we don't recommend the third-party meter/CT.

    • @foxess5669
      @foxess5669  ปีที่แล้ว

      YES again, T20 is compatible with the indirect meter measurement.

    • @GJ-nt5li
      @GJ-nt5li ปีที่แล้ว

      @@foxess5669 Can I have two inverters with zero export using this meter?

  • @tomtomi7853
    @tomtomi7853 ปีที่แล้ว

    can we modi with wlan?

    • @foxess5669
      @foxess5669  3 หลายเดือนก่อน

      Hello, thank you for your message. If you have still some questions, I adviced you to send an email to service@fox-ess.com with a detail description of your request (which products, series number, conditions of work...). Hope it will help. Have a nice day.

  • @taoduongquang5139
    @taoduongquang5139 4 หลายเดือนก่อน

    ok

    • @foxess5669
      @foxess5669  3 หลายเดือนก่อน

      I hope you have all the answers of your questions. Have a very good day.

  • @user-ns1ee1fu8d
    @user-ns1ee1fu8d 11 หลายเดือนก่อน

    نريد طريقة البرمجة

    • @foxess5669
      @foxess5669  3 หลายเดือนก่อน

      Hello and thank you for your message. Please feel free to send a message to service@fox-ess.com with a detail description of your request. Have a very good day.

  • @andremagel8382
    @andremagel8382 ปีที่แล้ว +2

    Was für ein Schwachsinn, alles falsch was hier gemachte wird. Bitte nicht nachmachen!

    • @foxess5669
      @foxess5669  ปีที่แล้ว +1

      Dear Sir, could you please describe more clearly about the 'mistake'?

    • @stevestrobel6497
      @stevestrobel6497 ปีที่แล้ว

      @@foxess5669 In the manual from the inverter H3-10.0E ist mention on page 23 you should take the PIN connection for RS485 - 1 for 485A and 2 for 485B in the video you say PIN connection 4 and 3 - so what is correct now ???????