Bina relay aur olp compressor run karne se kya compressor kharab ho jata hai Log kahte darect chalane se compressor kharab bhai jata hai bhai log batao
jin fridge me R 600 gas ho unme charging line pe brazing nahi karni chahiye. bahut dangrous hota hai, R 600 gas jaldi aag pakarti hai. charging line pe NRV ka use karna chahiye.
Dost is case me drayer se gas leak thi...aur jo oil ki AAP baat kar rahe ho . Wha agar Hahi lekg ya section se lekg ho yani ke fridge me Gas bilkul na ho tab oil aata hi....aur me 100 fridge karta hu to 3 ya 4 me hi flushing karni hoti hi.....mari ek live video hi usme mane btaya hai..... thanks for your comments 🌹🌹🌹🌹
Gupta ji. Mane is fridge me vaccum pump ka istemal kiya hi....me apni suvidha anusar self veakume ya veakume pump ka istemal karta hu... thanks for your comments 🌹🌹🌹🌹
Dost me pin valve kyo nahi lgata is par ek video upload ki hui hai AAP use watch karo.....me nrv pin valve kyo nahi lgata.. AAP use watch karo aapke swal ka jwab mil jayega thank you 🌹🌹🌹🌹
khan sahab aap bht bhadiya kaam krte ho 👍
Very nice Khan shab
Thank you 🌹🌹🌹🌹
Good work choking problem solution nitrogen aveleble nahi he tho kya kare us par vidieo banavo
Thank you 🌹 jald aapko flushing par bhi video milegi. bro aapko har trha ki jankari milegi yha par thanks for watching video 🌹🌹🌹🌹
Samsung ki inverter fridge ki pcb ke error pr ek video banaiye sir
1 blinking
2 blinking
3 blinking
Etc
Ha ji Bhai 🌹🌹🌹🌹
Good job nice 👍
Bina compressor ke is pip se compressor self vaccum ho jayega kya
Drier se self vacuum ho jaega lekin vacuum pump se aap vacuum kare to jyada best hai
Excellent
good work sir
Good work
Very good
Thank you 🌹🌹🌹🌹🌹🌹
Good
Sir kya compresser warenty me bhi gas ka charge lete hai kya
LG nhi leti...baki sab charge karte hi..... thank you
@@electrogeg welocme
Excellent work
Good sir
Good brother
Thank you sir 🙏 🌹🌹🌹🌹🌹🌹🙏
Good work 👍👍
Bina kate ke kar kise kare please replay
Sir charging cuppler gauge aap kidarse purchase kare
Delhi
Sir mere pass same refrigerator hai uska water drein trey me pani jama rahata hai
Nice
Bina relay aur olp compressor run karne se kya compressor kharab ho jata hai
Log kahte darect chalane se compressor kharab bhai jata hai bhai log batao
Dost inverter compressor ded ho jata hi.....
👍👍
nice
jin fridge me R 600 gas ho unme charging line pe brazing nahi karni chahiye. bahut dangrous hota hai, R 600 gas jaldi aag pakarti hai. charging line pe NRV ka use karna chahiye.
Singh Sahab is per bhi main jald hi video banaunga.. आपका तहे दिल से शुक्रिया आपके कॉमेंट्स हमारा हौसला बढ़ता है, शुक्रिया सिंह साहब 🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹
Experience zyada hoto koi dikkat nahi Refrigerator company ka kehna NRV walve se likege ki ya koi technesion ki chedkhani ki sMbhawna rehty he
Cost of this procedure (gas charging + drier ) change Rs?....
1500
Gas charging ka app kitna charge karte ho
Kaam kya hi aur kesa dek kar lete hi... gas charge 1500 2000 2500 3000.....
Gas charge karte samay fan chalu rakh na padta h dobal me
Ha ji dost
Thank
Welcome dost 🌹🌹🌹🌹🌹
Aap section pipe ko kyo nahi flush out kare
Is par ek video banate hai dost
AAP ne ek bi bar flash nahi Kiya q ki esk under oil chada hu va tha iski vajah se choking hone ka problem aa sakta hai thoda galat
Dost is case me drayer se gas leak thi...aur jo oil ki AAP baat kar rahe ho . Wha agar Hahi lekg ya section se lekg ho yani ke fridge me Gas bilkul na ho tab oil aata hi....aur me 100 fridge karta hu to 3 ya 4 me hi flushing karni hoti hi.....mari ek live video hi usme mane btaya hai..... thanks for your comments 🌹🌹🌹🌹
Guruji u r no
adapter konse number ka hai
Me samza nhi dost AAP kis ko adaptor bol rhay ho
Aap se bat ho payega kya sir
TH-cam ki liya new number lunga..fir pablic kar dunga...
Gas pipe charging Breging karte same Agg lagne ka risk hai
R600 ka running back pressure 0 psi hota hi is liya breezing karte samay risk Kam hota hi. Punching tool par bhi accha hai mera... thank you 🌹🌹🌹🌹
R600a charge kartai samaya self vaccum kyo nahi kiya.
Gupta ji. Mane is fridge me vaccum pump ka istemal kiya hi....me apni suvidha anusar self veakume ya veakume pump ka istemal karta hu... thanks for your comments 🌹🌹🌹🌹
Mai b ajj Samsung invetor frig doubbal door gas charging kiya hai R600a
Very good 🌹🌹🌹🌹
Aap kaha se ho sir
Delhi
No brazing pin vhalb lagana chahiye brazing risk hey
Dost me pin valve kyo nahi lgata is par ek video upload ki hui hai AAP use watch karo.....me nrv pin valve kyo nahi lgata.. AAP use watch karo aapke swal ka jwab mil jayega thank you 🌹🌹🌹🌹
Dc
R600a mein aap double punch MARTE ho
Nhi Bhai ji...1 hi punch lgata hu 🌹🌹🌹🌹
@@electrogeg but es video mein to apne 2 jagah punch lagaye charging pipe pr
Fridge mai oil aa gya hai
Dost AAP technicians ho kya....aur kis company ka fridge hi
Sir apka no kya hai
Good job sir
Good
Good Sir
Sir apka no kya hai
good job sir
Good