TIPS bago bumili ng aircon, Ok lang ba na mas malaking HP?

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 เม.ย. 2022
  • Dito po sa video na ito ay nagbibigay po ako ng aking opinion o suggestion bilang isang refrigeration and airconditioning mechanic patungkol sa kung ok lang ba na mas malaki o mas mataas na cooling capacity ng aircon ang bilhin para sa kwarto. Maganda po na mapanood muna ito bago bumili ng aircon.
    #airconditioner
    #aircon
    #tips
    #HVACR
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 276

  • @roysalazar2132
    @roysalazar2132 หลายเดือนก่อน +3

    Hini sinagot ng maayos ang tanong

  • @oscaryapit9151
    @oscaryapit9151 2 ปีที่แล้ว +1

    Salamat po sa paliwanag

  • @Just_do_it123
    @Just_do_it123 ปีที่แล้ว +3

    The bigger the better para hindi bitin. Mga bahay sa atin walang insulation. Pag patay ng AC, ilang sandali lang mainit kaagad. Kasing tulad ng AC ng kotse. Bakit nga ba hindi requirement ng mga enggr at architect ang insulation value sa pag gawa ng bahay.

  • @user-hp5yv4cf9k
    @user-hp5yv4cf9k หลายเดือนก่อน

    Sir ano po ang tamang settings ng american home window type non inverter para makabawas sa consumption.

  • @rayangelodeleon8173
    @rayangelodeleon8173 ปีที่แล้ว +2

    good evening po sir

  • @rodolfomorales5885
    @rodolfomorales5885 2 ปีที่แล้ว +2

    Sir i like your channel it educate me a lot.
    Godbless and more power.

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Maraming salamat po. Sana makatulong pa. Ingat po.

    • @roysalazar2132
      @roysalazar2132 27 วันที่ผ่านมา

      @@jepokractv5565 Sir, pakisagot nmn kung "sa papaanong paraan nakakasira ng component kapag OVER CAPACITY"

  • @Retro1965
    @Retro1965 2 หลายเดือนก่อน +1

    Common sense nalang po Yung chart na binibigay ng manufacturers na size ng room at size ng aircon computed naman lahat ng factors dyan alangan naman mag bigay sila recommended size ng room at aircon na hindi nila na compute halimbawa dyan pag room ang na compute nila expected na isang tao to tatlong Tao ang palagi dyan kaya lagyan nika ng minimum temperature kung isa lang ang tao Doon at maximum temperature pag 3 tao dyan, hindi naman kasi pang party party ang bedroom.

  • @paulnadera1570
    @paulnadera1570 ปีที่แล้ว +2

    Tama si sir. Height ng room, floor area, ilan ang natutulog, glass window ba ang bintana ay mga factor na dapat iconsider sa pag consider ng HP ng aircon. Lalo pag buhos ang pader napaka init lalo pag summer.

  • @jigz4526
    @jigz4526 หลายเดือนก่อน

    ok po ba 1hp tcl sa 6.25sqm may ref at tv. glass window. boarding house ko po kasi😊

  • @jimsamore06
    @jimsamore06 หลายเดือนก่อน

    Sir new sub nyo ako, tanong lang po kung ok lang po ba 1hp sa 9sqm to 10sqm na room 2 lang kami ni partner natutulog, may 32inches na tv na madalang gamitin at may dalawang cabinet na lalagyan ng damit na medyo nalaki ang size.. Salamat sa sagot sir..

  • @dickdoggie473
    @dickdoggie473 2 ปีที่แล้ว +1

    Ano ang natapos mo idol?

  • @simplepicking2889
    @simplepicking2889 หลายเดือนก่อน

    Hello sir new subcriber here po , may tanong lang po ako nag babalak po kase ako bumili ng ac unit .75 hp room size ko po ay 2.3x2.8m at taas ng ceilling ko po ay 7feet walng bintana yung room ko at yung pader hnd naman expose sa araw pero medyo mainit yung ceilling ko, dalawa lang po kame ng misis ko sa kwarto ko at wala naman mga appliace , sana po mapansin 🙏🙏🙏 at salamat po sa advice sir

  • @asmrRAWrice258
    @asmrRAWrice258 ปีที่แล้ว +10

    may nabili kmi carrier alpha 1.5 hp,, so kmi lang ngcompute ng sqm,compute nmin is 21sqm,, tpos nung kinompute ng installer,,mali compute nmin, kc nga yung heatload,ksama yung nakatira,, yung bintana,, tpos yung mga appliances,, so kelangan daw tlga 2hp,, kya ang nangyari sa kwrto nalang sya nilagay na at ang compute lang na hp sa kwrto eh 0.9 kya sobra sobra tuloy yung 1.5 na aircon dun,, pero mababa din nmn daw magiging bill if maintain lang sa 25 yung set ng aircon

    • @pidoolesco644
      @pidoolesco644 4 หลายเดือนก่อน

      Malinaw eto Tanong ko Buti nabasa ko eto balak ko Kasi bumili Aircon mataas HP para sa maliit na kwarto pero inverter

    • @JennilVargas
      @JennilVargas หลายเดือนก่อน

      kamusta po bill nyo ? mababa po ba?

  • @antoinettedigal1931
    @antoinettedigal1931 ปีที่แล้ว +3

    Sir, gawa naman po kayo ng video about proper Aircon HP capacity vs roomsize+heat load. Maybe you can also discuss how to compute for the heatload. Salamat po

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว +1

      Gawa po tayo content about jan. Salamat po

    • @antoinettedigal1931
      @antoinettedigal1931 ปีที่แล้ว +1

      @@jepokractv5565 promise mo pa yan ah 😉😘

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Hmm siguro po, gagawa nalang ako ng sample ko na computed na para may guide yung mga bibili. Halimbawa for a certain sq mtr na room with this number of appliances, size ng window and how many person =1hp
      Hindi na po siguro yung mismong computation :)

    • @antoinettedigal1931
      @antoinettedigal1931 ปีที่แล้ว +1

      Abangan ko yan ha.. anyway, naka subscribed na ako sayo 😘😉

  • @rommelgubalane5177
    @rommelgubalane5177 2 ปีที่แล้ว +1

    Hi po. New subscriber po ako. I have 1HP inventer aircon. Napansin ko po na laging full speed ang compressor nya kahit na reach na nya ang temp na naka-set. Minsan nga mas mababa pa ng 2°C ang room temp na ni set ko pero maririnig pa rin na gumagana ang compressor. Also, normal po ba na may leak or liquid na natulo sa compressor, yung may nakalagay na copper tube? Salamat in advanced sa pag sagot.

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว +2

      Mahirap madetermine sa tunog ng compressor o vibration lamang kung full speed ba ito o low speed. Maganda po ay magamitan ng clamp meter.
      Pero kung sure po kayo na ganyan nga ang problem ay baka mas probelma ang sensor ng aircon/thermostat. Or possible na mali ang pwesto nito.

  • @user-qo3fl9hb8m
    @user-qo3fl9hb8m หลายเดือนก่อน

    San ba mkita ung hp sa Aircon

  • @allyzamaecogasa4421
    @allyzamaecogasa4421 2 ปีที่แล้ว +2

    💪💪💪💪💪

  • @biensandoval6916
    @biensandoval6916 ปีที่แล้ว +1

    Sir anong best brand mo ng aircon, in all types? Thank you! and God bless!

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Halos pare parehas mga leading brands.

  • @ricoevangelista7623
    @ricoevangelista7623 2 ปีที่แล้ว +1

    Sir meron po ba kayo tech na kasing galing nyo yng pwde mag service at magkano kng maari malapit lng d2 sa pasay rotonda tnx po.

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Pasensya na po hindi po kami umaabot jan

  • @allyzamaecogasa4421
    @allyzamaecogasa4421 2 ปีที่แล้ว +2

    💪💪💪💪💪💪

  • @alexanderhabibon6336
    @alexanderhabibon6336 หลายเดือนก่อน

    mas matipid poba pag mas mataas yung cooling capacity ng inverter Aircon kesa sa room?
    Sample: room size is 8sqm and inverter aircon is 1hp.
    thank youu

  • @watatabee7917
    @watatabee7917 หลายเดือนก่อน

    ok ba if mas malaki ang hp

  • @aimeedejuan4933
    @aimeedejuan4933 ปีที่แล้ว +1

    Hi sana po masagot. Buong bahay walang room yung kusina bukod may pinto din so pwede isara. Yung ref po is nasa loob ng bahay mismo. 1tv 1ref 2ilaw tapos anim kami sa 1 bahay.

  • @BigartiS19
    @BigartiS19 6 หลายเดือนก่อน +1

    New sub niyo po ako, so tama lang po ba na laging may +.5 hp sa actual room capacity, considering na hindi constant ang heat load ng kwarto, like if madaming tao sa kwarto or mga gamit inside the room.

    • @jepokractv5565
      @jepokractv5565  6 หลายเดือนก่อน

      Yes pwede naman. Pero maganda kung halimbawa bilang naman sa pamilya nyo ang magkkwarto doon. Dapat masabi sa surveyor iyon para macompute yung sakto. Kung ilan yung pinaka madalas na tao doon.

  • @rmerose22
    @rmerose22 2 ปีที่แล้ว +2

    Tanong ko lang po sana sir kung pwede po bang buhatin ang aircon window type na nakatagilid paakyat sa itaas kasi po yun hagdan namin is spiral. Medyo makitid po at yun aircon po malaki ang kaha. Salamat po

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว +1

      Pm po kayo sa j rey cruz ref and aircon services sa fb, number nyo po. Tawag ako.

  • @ricardopalmo46
    @ricardopalmo46 ปีที่แล้ว +2

    Tama kac nung bumili kami thru online lng, sobra ng 4sqm ung size ng room para dun sa ac hp capacity na kinuha namin pero nung ikakabit na sabi nung installer di raw nila pwede ikabit un kac mamroblema lng kami at magrereklamo dahil baka hindi lumamig ung room tapos sagarin pa kami sa kuryente kaya ang ending ung 1.5hp di nila kinabit tapos sinuggest nila na dapat ay 2.5hp ang kunin kaya yun binalikan nalang ulit kami hehe

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว +1

      thank you for sharing po.

    • @frankcadillac1456
      @frankcadillac1456 11 หลายเดือนก่อน +2

      Tinamad lng Sila magkabit. 😂

    • @MoonArk
      @MoonArk 2 หลายเดือนก่อน

      kaya di kinabit. para kumita pa sila. wala.na sila pake kun di gaano malamig di naman sila.mag babayad ng kuryente.
      kun sobrang.underload.pwede pa.. kung pro .5 hp lang ang kulang. bakit hindi. kaya nga may low medium.high ang settings nyan.

  • @dhangski1742
    @dhangski1742 2 หลายเดือนก่อน

    sir anong marerecommend nyo pong brand at ilang Hp na inverter window type ac sa room na 18 sqm with 2-3 PC
    TIA po

  • @arvielyntayco2424
    @arvielyntayco2424 ปีที่แล้ว +1

    Good day po sir, new lang po ako dito sa channel nyo, balak po sana namin bumili ng aircon, ok lang po kaya ang 1hp split type invertedr aircon sa room na may L-3.5m, W-2.5m, H-4.5m then no window po, 2 adults and 2 kids po natutulog. .minsan po may nkikitulog na 3 adults. .thank you in advance. .

  • @crisjohnmedina3849
    @crisjohnmedina3849 11 หลายเดือนก่อน +2

    Good day Sir, nagpalagay po ako ng AUX Inverter 2HP para po sa 16sqm na room, tpos exhaust sa katabing kwarto same size ( sobrang dalang lang gamitin pag may bisita lang, mga once a month) tpos tapat din yun room sa araw pag hapon. Okay lang po ba un 2 HP na capacity? or mas magiging malaki ang consumo sa kuryente? Thank you in advance po.

    • @jepokractv5565
      @jepokractv5565  11 หลายเดือนก่อน

      Maganda po macomputed ang heatload.

  • @francesgaspe9633
    @francesgaspe9633 ปีที่แล้ว +1

    Good day Sir, ask ko lang, ilang hp window type po ba dapat ang 19 to 20sqm na studio type may tv pero di naman masyadong nagagamit, ang meron is ref na laging nakasaksak. sa labas na kami nagluluto hindi na sa loob. sana masagot kasi nga ang window type ac namin is 1Hp lang at hindi talaga sya nag oon and off kahit ilagay na sa thermostat #6 at naka highcool hanggang #9 lang thermostat namin, salamat sa magiging sagot

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Maganda magpasurvey po para macompute ng tama

  • @karldhavenorboc2273
    @karldhavenorboc2273 6 หลายเดือนก่อน +1

    Kwarto ko po ay 2.30x2.30m, nabili ko pong ac ay kolin 0.75hp full dc inverter, tatlong tao kami sa kwarto at tsaka may pc at laptop for work, at one glass window with block curtain okay lang po ba, ano po masasabi nyo? New subscriber!

    • @jepokractv5565
      @jepokractv5565  5 หลายเดือนก่อน

      Sa tingin ko ok po yan

  • @speechless1111
    @speechless1111 8 หลายเดือนก่อน +1

    Sir hello po. Ano po magandang aircon window type po sana para sa 9sqm na room tv lang po at isang ilaw lang ginagamit tas isang clip fan hnd nmn po sya direct na natatamaan ng araw bali mainit lng sya dahil na dn sa singaw ng pader

  • @glesiemaeparreno2212
    @glesiemaeparreno2212 ปีที่แล้ว +1

    Sir new subscriber here. Tanong ko lang po kung ok lng ba na after patayin ung AC na nakaset sa low cool, paandarin agad pero sa fan mode po. Nasa gitna po kasi ung OFF ng AC ko po. Thanks in advance po.

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      yes, ok lang naman kung fan mode lang

  • @subzer_08vlog64
    @subzer_08vlog64 9 หลายเดือนก่อน +1

    Sir 7.4 sq meter ung room nmin, 5 kami sa loob 2 adults at 3 mga bata may tv 2 bintana.Hnd nman maxado direct sa sunlight ang mga pader.Ilang hp po kaya ba2gay sa room?tnx in advanced

    • @jepokractv5565
      @jepokractv5565  5 หลายเดือนก่อน

      Mas ok po kung masurvey pero sa tingin ko po 1 hp

  • @viligarrido8807
    @viligarrido8807 ปีที่แล้ว +1

    Good pm sir. Patulong sana ako ok lang po gamitin ang 1hp window type inverter sa room size na 7sqm. Ang heatload po ay 2persons, ref, laptop at hindi gaanu napapasukan ng hangin ang room? Salamat po sa tulong.

  • @jexsamson
    @jexsamson ปีที่แล้ว +3

    Hi Sir, ask lang po. Ang room size ko is around 9sqm (2 sides ng wall is may 3 panel windows each, may computer, lights, electric fan, and 2 persons sleeping)
    Ang nabili ko ay 1.5hp TCL Titan Gold Inverter. Sobra po ba yun para room ko at magkokonsumo ng malaki sa electricity or sapat na?
    Salamat po

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Kung tutok sa araw ang kwarto mo, pwede na din, pero sa tingin ko medyo oversized ang aircon mo.

    • @jexsamson
      @jexsamson ปีที่แล้ว

      Pinapalitan ko ng 1hp sir. Oks parin ba yun? Salamat sa sagot par ko. 😁

  • @lordryanpineda5993
    @lordryanpineda5993 ปีที่แล้ว +1

    boss ano maganda bilhin 2nd hand na ac inverter o brand new na inverter? pero wala naman issue yung binebentang 2nd hand

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Kung kilala nyo naman po yung nagbebenta ng secondhand inverter ok lang, pero mas ok po kung brand new.

  • @johnvilla
    @johnvilla 2 ปีที่แล้ว +1

    Sir ano po ba mas okay gamitin and more cost efficient dry mode or cool mode for an inverter type AC. Thanks in advance.

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Tipid din naman po ang dry mode.
      Pero kung i simplify natin. Dry mode po ay parang cool mode lang din ang pinagkaiba lang ay sa dry mode. Hindi nyo pwedeng mai adjust ang fan speed. Nakalow speed lang ito palagi.
      Personally, nag seset lang ako ng 23 or 24, tapos low fan speed.

    • @johnvilla
      @johnvilla 2 ปีที่แล้ว

      @@jepokractv5565 Thank you sir, oo nga po na noticed ko di pwede ma adjust ang fan speed try ko po mag dry mode palagi advisable po ba whole day? di po ba delikado sa health or skin natin? Thanks.

  • @DanelaMulles-wb1ru
    @DanelaMulles-wb1ru 2 หลายเดือนก่อน

    Good morning, ok lng po ung 0.8 hp n daikin s kawrto n 6sqm, 2 person lng glass window tapos kabinet n lagayan ng damit, ang laman ng kwarto, thanks

    • @jepokractv5565
      @jepokractv5565  2 หลายเดือนก่อน

      Sa tingin ko kaya n po

  • @goodtoknow13
    @goodtoknow13 2 ปีที่แล้ว +1

    Sir kc un room q 4x4m ,wala naman nakalagay kung yun built in na cabinet/drawer, ilan kaya hp ang need, para kapag namilj nq ng gamit alam ko na po Salamat

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Depende po sa heatlaod iyan. Maganda magpasurvey po kayo para macompute.

  • @bingortiz8634
    @bingortiz8634 2 ปีที่แล้ว +1

    Ang size ng room ko ay pang 1hp pero gawa sa init ng araw sa concreto concreto rin kc ang bubong, ginawa kong 1.5hp inverter. Tama ba un decision ko?

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Pwede sin po sana na mas ayusin ang insulation ng kwarto or mag devider. Pero kung no other choice. Good decision na po ang ginawa nyo.

  • @cangelmichael4953
    @cangelmichael4953 2 ปีที่แล้ว +1

    Anu praktikal o mas ok na bilhin na Aircon split Types . Non inverter o Inverter na Aircon? Thank s sasagot.

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว +1

      gawa po tayo video about jan.
      for me, go for inverter na. kung tumagal ito ng let say 3 years . bawi mo na sa kuryente yung dapat sana na ipambibili mo ng non inverter.
      dapat lang po ay may maayos kayong technician na magmmaintain.

  • @isaganideguzman1481
    @isaganideguzman1481 2 ปีที่แล้ว +1

    Sir un po bng heater sa paliguan pg nakasaksak , may konsumo ng kuryente

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      gawan po natin video yan . salamt po

  • @melaniecaballero7294
    @melaniecaballero7294 2 ปีที่แล้ว +1

    hello po makaktipid po ba ung pag gamit ng 6-8hrs sa gabe tas sa umaga 4hrs ?

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Mas tipid po sana kung gabi lang. Pero kung need nyo din po gamitin ng umaga at kung inverter naman po. Sa tingin ko ay worth it naman po ang pag gamit nyo nyan kung kailangan talaga.

  • @ahmaderan8224
    @ahmaderan8224 ปีที่แล้ว +2

    Anu po sir gagawin sa split type aircon pag matagal na hindi gagamitin mga 1year?

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Patayin po ang breaker.pero maganda po iyan napapaandar kahit 1 per week. Iwas stuck up

  • @rachelgonzales9715
    @rachelgonzales9715 2 ปีที่แล้ว +2

    sir pwde pong mag patulong.. ung ac namin wala pang 1yr mag 1yr pala pero hindi lumalamig pero. nagana naman po ang fan nyan ano po kaya ang problema . salamat po

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Maganda macheck po iyan ng tech.

  • @rolandulidan9174
    @rolandulidan9174 10 หลายเดือนก่อน +1

    sir ano advice mopo sa room na 5sqmeter 2adults 1kid bed lng gamit,, tas may curtain sya 4sqmtr yong kabila nandon mga gamit like 3 durabox, nilagyan curtain sya para di msyado tagos ung magiging lamig sa kabila. ano po advice nyo na HP inverter aircon? plywood double wall po sya . thanks

    • @rolandulidan9174
      @rolandulidan9174 10 หลายเดือนก่อน

      sana mag reply ka idol. thanks

    • @jepokractv5565
      @jepokractv5565  10 หลายเดือนก่อน +1

      Sa tingin ko 1 hp pwede na.

    • @rosemariejordan1112
      @rosemariejordan1112 9 หลายเดือนก่อน

      @@jepokractv5565 gud pm sir, sna po mtulungan nyo ako, pa advice nmn po, 19 sqm studio type, May partition lng ng cabinet at kurtina para magkaroon ng kwarto, high ceiling , meron washing machine, 32 inch Tv nakalagay s sala, then sa kwarto po n May partition apat po kmi natutulog, may gamit kmi 2hp non inverter , setting po is 5 sa thermostat and low cool..10 pm to 2 am lng po nagagamit ang aircon kunsomo nya po is 10kwh for 5hours , balak ko po mag buy 1hp na inverter at mura lng ang consume sa kuryente, ano po ma recommend nyo at pwede po kya ang 1hp sa amin? Sana po masagot mo sir.. marami salamat po.. Godbless

  • @finntv4280
    @finntv4280 ปีที่แล้ว +2

    Sir, sabi ng nagi-install ng aircon namin, bawal daw mag luto kapag naka bukas ang ac sa kusina? Bakit po kaya? Thank you sa pag sagot.

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Pwede naman po, pero mas magiging malakas sa kuryente dahil dagdag ito sa init at isa pa po mas mabilis po itong dudumi dahil sa moist at mga mantika na galing po sa niluluto na pagkain.

  • @regnerportillo6378
    @regnerportillo6378 8 หลายเดือนก่อน +1

    Sir good day, new subscriber. Tanong ko lang. 9sqm ang kwarto ko at ako lang mag isa. Ano po ba ang da best na aircon ang dapat kung bilhin? Split type o window type?. At ilan po bang hp ang sapat na.? Yung maka ka tipid sana. Salama boss.

    • @jepokractv5565
      @jepokractv5565  8 หลายเดือนก่อน

      Depende din sa insulation ng kwarto mo. Mas safe sa 1hp yan pero kung maganda insulation at hindi naman gaano mainit. Pwede 3/4. Kung 3/4hp i suggest kahit wag ka na mag inverter. At kung may provision for window type go for it. Mas mababa ang maintainance cost.

    • @alexmy264
      @alexmy264 6 หลายเดือนก่อน

      ​@@jepokractv5565 sir help po sana. my room size is hindi lalampas ng 7sqm. may 2 tao natutulog. nasa second floor po ito so meron direct sunlight. it has two windows, both are covered with blackout curtains. may isang kama, isang PC at isang TV. ano po b mgandang HP. thank u po and i look forward to your expert advice. 😊

  • @derickfederizo4257
    @derickfederizo4257 ปีที่แล้ว +1

    Sir Tanong kolang Tama ba ang ac. na (0.5Hp) sa room ko at 2 person, bato yung wall at yung kisame naman ay hardiflex.
    Ito sukat ng room/heatload
    *width 1.854 meters.
    *Length 2.921 meters.
    *One window, size-(31x 34).
    *Tv.
    *One electric fan.

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว +1

      Yes, kaya po iyan ng aircon nyo..

    • @derickfederizo4257
      @derickfederizo4257 ปีที่แล้ว +1

      Salamat sa pagsagot sir, Carrier optima 0.5hp.bibilin ko e, ask Kona den kung pwede na ba I rekta sa socket yung Aircon or need talaga ng CB.Na 15 amps? For safety.btw naka subscribe Nako sayo para mas madame Pako matutunan. Next content mo sir General cleaning naman ng carrier optima 0.5hp. hehe

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว +1

      @@derickfederizo4257 mas maganda kung meron sana for safety. Maraming salamat po sa pag subscribe. :)

  • @markbayer7759
    @markbayer7759 2 ปีที่แล้ว +1

    Ser dalawa po un room nmin one Aircon lang gmit naglagay Ako auxiallary fan ok b yun,pls reply

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว +1

      Hindi sya advisable para sa akin pero jung ganyan talaga ang set up. You need 2 exhaust fan. Isang papunta ang buga sa kabilang kwarto at isa pabalik ang buga sa may aircon na kwarto. Mas maganda din kung pag hiwalayin ang exhaust. Sana po makatulong.

  • @alexmy264
    @alexmy264 6 หลายเดือนก่อน +1

    sir help po sana. my room size is hindi lalampas ng 7sqm. may 2 tao natutulog. nasa second floor po ito so meron direct sunlight. it has two windows, both are covered with blackout curtains. may isang kama, isang PC at isang TV. ano po b mgandang HP. thank u po and i look forward to your expert advice. 😊

    • @jepokractv5565
      @jepokractv5565  6 หลายเดือนก่อน

      1.5 hp sa tingin ko, pero maganda masurvey po iyan para sakto.

  • @ralphangel1836
    @ralphangel1836 7 หลายเดือนก่อน +1

    Hi sir naka double deck po kami 3 kami sa room midea 1.5 hp ang gamit namin window type.
    Ano pong temp ang tama sa room namin
    At naka auto po ba dapat or high cool

    • @jepokractv5565
      @jepokractv5565  6 หลายเดือนก่อน

      24, low fan. Cool mode.

  • @lordryanpineda5993
    @lordryanpineda5993 ปีที่แล้ว +1

    hello po okay po ba yung brand na matrix na 1hp split type?

  • @jeraldinmanto2660
    @jeraldinmanto2660 ปีที่แล้ว +1

    Sir anu po bah magand brand samsung wind free or LG?

  • @marialuciasuplito1912
    @marialuciasuplito1912 10 หลายเดือนก่อน +1

    sir pag mas malaki ang hp mas malakas ba sa koryente? 1hp media gamit namin pero kahit .6 pwede na dito sa kwarto namin,bale twing gaga itin namin AC kada 1hr eh 1kilowats dagdag sa submiter namin.twing mag Ac kami wslang ibang gamit na sinasabay.

    • @jepokractv5565
      @jepokractv5565  10 หลายเดือนก่อน

      yes possible mas malakas sa kuryente.

  • @joeymasarateii3417
    @joeymasarateii3417 3 หลายเดือนก่อน

    nakabiki po ako 1.5 ho window type and ako lang po and one computer , 8sqm meter and room. Okay lang ba?

    • @kmf402
      @kmf402 2 หลายเดือนก่อน

      Sobra

  • @janrylozada428
    @janrylozada428 6 หลายเดือนก่อน +1

    4.684m x 2.362m and 8ft lng po ceiling, ilang hp po gagamitin ko? no source of heat po galing sa labas and taas, for 3 persons po kasama baby. tnx in advance

    • @jepokractv5565
      @jepokractv5565  6 หลายเดือนก่อน

      Maganda po iyan masurvey, para makita din ang insulation ng kwarto at ang sikat ng araw. Pero sa tingin ko po ay 1.5hp. To 2.

  • @jadebrown8968
    @jadebrown8968 3 หลายเดือนก่อน

    pinasukat ko po room namen 10-12sqm daw po, ang ac na nabili ko po ay astron .6hp coolmode lage 16 pero nkaka 2hrs na hindi nya napapalamig ang buong room, kundi tapat lang po ng ac ang malamig ano po kaya problema😢

    • @christianerni2589
      @christianerni2589 หลายเดือนก่อน

      Kulang yan.. 1hp na pag ganyang size.. 10-15sqm- 1hp na ang ginagamit.. 16-21 sqm = 1.5hp, 22-and up sqm= 2hp
      Yang 0.6hp pang studio type lang yan. Max of 9sqm

  • @fahrrent
    @fahrrent ปีที่แล้ว +1

    mas malakas ba sa kuryente ang 2hp over 1.5hp? 10sqm na room pero naka loftbed with high ceiling po, ano po ba ma advise nyo na kung anong hp bblhin? 3/4 ng room naka loft bed po, bali 2dogs, 1 baby and 2 adults, kaya po ba ng 1.5hp palamigin both ilalim ng loft bed and sa loftbed? salamat

    • @jepokractv5565
      @jepokractv5565  11 หลายเดือนก่อน

      About sa loftbed, depende sa magiging pwesto ng indoor unit nyo maganda sana ay tatamaan sya ng discharge air ng indoor unit para lumamig din. Go for 1.5hp. At tip lang din po, mas dalasan nyo po ang pagpapalinis dahil may dogs. Medyo mas mabilis mag dumi amg ac.

    • @fahrrent
      @fahrrent 11 หลายเดือนก่อน

      @@jepokractv5565 hello, salamat sa reply, nasa isip ko is 2hp, overkill na po ba ang 2hp? ska mas malakas ba sa kuryente ang 2hp?

  • @macoja2931
    @macoja2931 ปีที่แล้ว +1

    Sir tanong ko lang po, bakit po kaya nagkakatubig yung loob ng outdoor, normal po ba na malakas ang tulo ng tubig doon sa may discharge tapos di mareach ang temperature settings, lumalamig din po yung kaha ng outdoor. Salamat po in advance.

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว +1

      Maganda macheck po iyan.

    • @macoja2931
      @macoja2931 ปีที่แล้ว

      @@jepokractv5565 Thank You po sa reply, pina check po namin dati po ang problema lang kalahati lang ang gumagana pero naaabot nya ang temp. Malamig po tapos sabi ng nag repair sa board daw po sa outdoor dinala po nila tapos siningil kami ng 5 thousand tapos ganyan na po nangyari sa aircon namin. Thank you po masyado pong mahaba .

  • @GonzaloSalcedo-hw9fm
    @GonzaloSalcedo-hw9fm ปีที่แล้ว +1

    Sir papaano ba ma compute ang 0:31 kunsomo ng aircon 1hp non inverter tanx po

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Meron po sa google kung paano magcompute ng kilowatt hour

  • @louieafulugencia9474
    @louieafulugencia9474 5 หลายเดือนก่อน +1

    Thank you sa vid sir. Pero ok lang po ba na mag over po ng hp? Ilagay natin na nacompute na po lahat ng heat capacity. 1hp lang ang computation. Ok lang ba na 1.5hp ang ikakabit po?

    • @jepokractv5565
      @jepokractv5565  5 หลายเดือนก่อน

      Ok lng. Mas malakas lang po sa kuryente.

    • @louieafulugencia9474
      @louieafulugencia9474 5 หลายเดือนก่อน

      @@jepokractv5565 salamat po sir

  • @ice8244
    @ice8244 ปีที่แล้ว +1

    good day po sir, ok lang ba naka on ang window type ac ng 48hours? koppel brand po

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Kaya naman po ng aircon. Kaya lang para sa akun mas maganda po na may pahinga ang aircon.

    • @ice8244
      @ice8244 ปีที่แล้ว

      @@jepokractv5565 sir ilang oras po ang pahinga ng ac bago ion ulit?

  • @michaelcebrano3133
    @michaelcebrano3133 2 ปีที่แล้ว +2

    Sir un terminal ng capasitor ko 4 cya nasusunog ano po b ang problima nya bka sumabog maamoy cya

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Possible corrosion or loose contact. Maganda marepair po ng tech.

  • @michaelrelato5722
    @michaelrelato5722 11 หลายเดือนก่อน +1

    Good day po, nakabili po kami ng 1hp aux inverter, ang heatload lang po ay isang 55 inches tv, 1 led light, isang standfan, 2 panel window na may kurtina, 2 adults at 1 bata ang setting po namin ay 25C medium speed, mga magkano po kaya ang aabutin ng consumption kung 5 hours a day for 1 month ang gamit nmn? Salamat po

    • @jepokractv5565
      @jepokractv5565  11 หลายเดือนก่อน

      pinakamaganda po tingnan nyo po ang total kilowatt hour nyo per day, then icompute nyo po para makuha ang per month. slamat po.

  • @relisagonzalvo6176
    @relisagonzalvo6176 2 ปีที่แล้ว +2

    anu po ba ang pag on ng air con? simula po ba sa mababa bago mag on or sa mataas agad?

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      ok lang po kahit mag start po kahit saan kayo magstart. pwede po na mag set na po kayo ng gusto nyong setting kahit sa simula palang. salamt po sana makatulong po.

  • @antoniobuhat4602
    @antoniobuhat4602 ปีที่แล้ว +1

    Sir may paraan ba para macontact kayo at mapagawa ang refrigerator

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      PM po sa J rey cruz ref and aircon services sa fb page po

  • @kayet19
    @kayet19 2 หลายเดือนก่อน

    Sir pa assess naman, hingin ko lang opinion nyo, ok po ba ang 1.5 hp sa is a 15sqm room with 6 to 7 people at isang laptop?

    • @jans7230
      @jans7230 2 หลายเดือนก่อน

      ako po 1.5hp pero 15sqm hehe, kapag hapon direct yung araw sa kwarto kaya mainit, so i consider yung init kaya 1.5ph kinuha namin. 2 lang kmi ni hubby, mabilis siya lumamig kahit 23-25 degrees lang. cool and low fan. 4-5hrs lang namin ginagamit sa gabi.

  • @mmv14
    @mmv14 ปีที่แล้ว +1

    Sir, ang binili ko pong aircon ay 1hp. Ang room ko po ay 2.5x2.5 lang. Pero binubuksan ko po ang pinto para ma-airconan din ang sala at kwarto ng mama ko. Ang total sukat na na-aaircon ay 5x5. Okay lang po ba yun?

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Medyo mahihirapan po iyan dahil sa airflow. At depende pa sa heatload po

    • @mmv14
      @mmv14 ปีที่แล้ว

      @@jepokractv5565 masisira po ba compressor nun?

  • @jhayrwinsuaga5722
    @jhayrwinsuaga5722 2 ปีที่แล้ว +1

    sir màgtanong lang po , tama po ba kc aircon ko po nakàlàgay sa low cool, at nakaset sa 18'c para hindi malamig wala po bang epecto or masisira po ba ? sabi ng iba hindi daw maganda na setting , ano po ba dapat ang setting.
    maraming salamat po

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว +1

      Malamig po ang 18.
      Depende po sa tao iyan kung ginawin po ba o lamigin ang katawan.
      Pero ako personally, 23 ay ok na po. Minsan 24.low cool.

    • @jhayrwinsuaga5722
      @jhayrwinsuaga5722 2 ปีที่แล้ว

      @@jepokractv5565 maraming salamat po sir, marami po akong natutunan sa panood , at pakikinig sa mga paliwanag nyo po.
      God bless you more po sir.

  • @EhmGeeVlogs
    @EhmGeeVlogs 2 ปีที่แล้ว +1

    Sir my bedroom size is almost 10sqm w/ 1 window and 1 led bulb light at computer. Ilang hp po kaya dapat? Gusto ko sana split type inverter na. Thanks po

  • @owen111207
    @owen111207 ปีที่แล้ว +1

    Boss 9sqm ang sukat ng room pero ang itaas ko ay yero ang bubungan at pader na expose sa init talaga. Okay lang po ba na 1hp window type ang bilhin? Salamat

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว +1

      ayusin po muna ang insulation bago mag aircon. malakas po sa kurytente iyan at baka masayang po ang ibabayad nyo sa kuryente hindi gaanong mararamdaman,.

    • @owen111207
      @owen111207 ปีที่แล้ว

      @@jepokractv5565 naayos naman na boss,may kisame at nasarahan na lahat ng dapat labasan ng lamig at naging isang buong room na talaga.

  • @valeryjanegutierrezgarcia3796
    @valeryjanegutierrezgarcia3796 3 หลายเดือนก่อน

    Hi sir, kapag po ba 2.5hp mas malakas ang consume ng kuryente?

  • @adrianorense1492
    @adrianorense1492 ปีที่แล้ว +1

    Hindi naman nasagot ang tanong. What if balak talaga nung subcriber bumili ng mas malakas na aircon i.e. 1.5hp aircon for a 1hp room, ano effect nun sa electric consumption or sa aircon unit? That way if i'm moving to a bigger house/room, hindi ko na kelangan bumili ng higher hp aircon

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Tinapos nyo po ba ang video? Nag skip po ba kayo? 3:57 mins sinabi ko po jan na kung mas malaki ang mabili nyo para sa kwarto ay mas malaki ang magihing consumption nyo sa kuryente. Kaya ang sinabi ko po sa video mas maganda kung masurvey ang room para sakto ang mabili na aircon. At hindi maging mas malaki ang consumo sa kuryente. Ngayon kung gusto nyo gamitin ang mas malaking hp para sa maliit na room. Ok lang po yan. Kaso asahan nyo kuryente nyo mas malaki compared kung sakto lang ang hp na kukunin nyo. Salamat po.

    • @adrianorense1492
      @adrianorense1492 ปีที่แล้ว +1

      @@jepokractv5565 noted. Hindi nman ako ngskip pero hindi lang 100% attention ko.namention mo sya for 10 sec in a 5min video kaya hindi ko nasagap.pero salamat sa sagot

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว +2

      Maraming salamat po at pasensya na po. Nagpaliwanag lang din po ako ng mga maaari nating gawin bago bumili ng aircon. mas pag iigihin ko po ang pag gawa ng video. Maraming salamat po malaking tulong po ang inyong comment.

  • @rhoydacumos6722
    @rhoydacumos6722 ปีที่แล้ว +1

    sir 10sqrmeter ang kwarto tapos isang electricfan 2adult at 2child po ang natutulog anu po pwede n split type aircon 1hp or 1.5hp

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว +1

      1.5

    • @rhoydacumos6722
      @rhoydacumos6722 ปีที่แล้ว

      ​@@jepokractv5565salamat po s pag sagot nag subscribe n din po ako hehehe Sana bahain ng subscriber ang dumating s inyo godbless po

  • @kaliyahporca7164
    @kaliyahporca7164 หลายเดือนก่อน

    boss Jepok
    Planning to buy 1.5hp inverter aircon sana
    Length 3 meter
    Width 2.3 meter
    Height 2.5meter
    3 to 4 person lang sa room
    Ung init ng araw umaga till hapon kaya kahit gabi mainit pa din ung pader
    No appliances sa loob
    overkill ba ung 1.5? or pwede na 1hp?
    Any brand na tipid sa kuryente?

    • @dongbertovlog7348
      @dongbertovlog7348 17 วันที่ผ่านมา

      Kaya na 1HP sir . Hitachi na brand hitachi sir matipid po talaga

  • @salvaciontadena9163
    @salvaciontadena9163 ปีที่แล้ว +1

    Sir, yong aircon po namin nagyeyelo po sa harap, magkano po ba mag paayos po,? Salamat po

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Pm po kayo sa j rey cruz ref and aircon services po. Salamat po.

  • @epsgamertv6110
    @epsgamertv6110 ปีที่แล้ว +1

    Basta inverter ac kahit oversized ang hp pwede parin yan sa mas maliit na room. Ang di la g pwede sa ganyan yung non inverter.

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว +1

      Much better kung sakto sa heatload. Kung masyadong malaki,it can cause short cycling, may mga sensor po ang inverter aircon kaya possible na hindi lumamig masyado kung masyadong malaking hp ang gagamitin. Tip ko sa ganyan, mag set nalang ng hindi masyadong malamig or magdagdag ng heatload sa kwarto na palalamigin

    • @gavhinlacsamana
      @gavhinlacsamana 11 หลายเดือนก่อน

      ​@@jepokractv5565sir pag 1hp po room ko then direct sunlight kaya sinuggest sakin ng nabilan ko eh 1.5hp na split type tama lang po ba ginawa ko na nag pa oversize ako na ac heatload po 32inch tv isang ilaw isang clip fan at isang blower tatlo lang kami sa room isa pong 1years old baby

  • @florentinoalvendia7367
    @florentinoalvendia7367 2 ปีที่แล้ว +1

    Sir bakit may lumalabas na ex E1 or E4 tapos hindi na malamig. Ano ang ibig sabihin nun?

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Maraming possible cause. E1 kadalasan "communication error" Maganda macheck po ng tech.

  • @didotbasmayor
    @didotbasmayor 7 หลายเดือนก่อน +1

    new subscriber here, meron kaming portable aircon grabe an lakas s kuryente 1.5hp ngaun planning to buy window type aircon di po pde split typle 10sqm po room namin 3 meters un ceiling 1 kama wla pong appliances s loob bukod sa mga wardrobe cabinet 2 adults, 3 kids 1 baby, ilang hp po ba dpat samin? also sa kabilang room 10sqm din sya kaso bawal n lagyan ng window type aircon kaya naisip nmin lagyan ng exhaust ubra kaya? sa kabilang room 1 adult, 3 kids naman.. if idadamay namin kabilang room ilang hp kaya dapat total of 3 adult 7 kids? tapos kaya kaya un through exhaust lang? parecommend naman po ng brand and model if ever hehe ty much

    • @BigartiS19
      @BigartiS19 6 หลายเดือนก่อน +1

      Hindi po kaya ng 1hp yung 2, rooms, considering may mga gamit pa, hindi na lalamig kwarto niyo, mataas pa kuryente niyo

    • @jepokractv5565
      @jepokractv5565  6 หลายเดือนก่อน

      Well said

    • @jepokractv5565
      @jepokractv5565  6 หลายเดือนก่อน

      No choice. Portable talaga. Malakas po talaga sa kuryente.

    • @jepokractv5565
      @jepokractv5565  6 หลายเดือนก่อน

      Mas maganda kung tag isang aircon yung room.

  • @ryanCHRYSTAL3
    @ryanCHRYSTAL3 ปีที่แล้ว +1

    idol san po maganda astron inverter or ung LG?

  • @maloucabrillas4684
    @maloucabrillas4684 2 หลายเดือนก่อน

    GOod day po. Pwede nb ung 1hp split type sa room n ang size po ay nasa 6sqm then parang ang taas ng room ay nasa 10ft po?

  • @johnalexanderayudan9229
    @johnalexanderayudan9229 6 หลายเดือนก่อน +1

    Sana mapansin mo Sir " Worth it ba bumili ng 2nd hand aircon? And anytipe anong dapat icheck?"

    • @jepokractv5565
      @jepokractv5565  6 หลายเดือนก่อน

      Much better kung sa kakilala, atleast alam nila kung ano ang sira o kung may ipinagawa na.

  • @gibsbatengga2542
    @gibsbatengga2542 ปีที่แล้ว +1

    sir, 3m W, 5m, 3m H. okay na po ba yung panasonic 1hp inverter po?

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Depende pa po sa heatload at kung saan ang installation. Pero kung good lahat. Ok naman po iyan

  • @stephen8014
    @stephen8014 ปีที่แล้ว +1

    Totoo ba na mas makakatipid sa higher hp kasi di daw nahihirapan palamigin ang room so di cya laging nakaturbo?sana may sasagot.

  • @mayari3200
    @mayari3200 ปีที่แล้ว +1

    Sir mas nakakatipid ba pag naka eco mode?

  • @ricoevangelista7623
    @ricoevangelista7623 2 ปีที่แล้ว +2

    Saan po ba location nyo nag service po ba kayo sa metro mnl may problema po yng carrier aircon malakas naman ang buga ng hangin pero walang lamig tnx po.

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      Mayamot antipolo po kami. Marikina area service only.

    • @ricoevangelista7623
      @ricoevangelista7623 2 ปีที่แล้ว +1

      Sir salamot po sa reply nyo inaabangan q vlog nyo sa u tube alam q po magaling kayo tech. sayang malayo pala sa inyo.

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว

      @@ricoevangelista7623 maramong salamat po. Hindi pa po tayo makagawa ng bagong video medyo busy pa sa mga client. Pero gagawa at gagawa tayo :) ingat po

  • @jaysonsumeguin1363
    @jaysonsumeguin1363 ปีที่แล้ว +1

    Pwede po ba mas mataas na hp para sa room a 1hp lng dapat ang ilalagay po ay 2.5 hp.. mataas po ba konsumo nun sa kuryente? Sana lo masagot nyo

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Yes, ok lang po. Kaya lang expect nyo din po yung electric consumption ng 2.5hp.

    • @jaysonsumeguin1363
      @jaysonsumeguin1363 ปีที่แล้ว

      @@jepokractv5565 hindi po ba makakatipid dun?

  • @jonathancanlas7558
    @jonathancanlas7558 2 ปีที่แล้ว +2

  • @kaseyleneante3814
    @kaseyleneante3814 ปีที่แล้ว +1

    Bkt po ung Carrier WCARH009EEVC2 inverter, di maxado lumalamig? ☹️

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Kung brand new po iyan. Sabihan nyo po ang pinagbilhan nyo. Kung hindi po. Maganda macheck po

  • @zkejauraflow7338
    @zkejauraflow7338 ปีที่แล้ว +1

    Bumili kami ng 1.5 hp pra sa 12 sqm. May dalawang bintana kami na mgkk hiwalay saka 4 kming nka tira. tama lang po ba yung 1.5hp pra samin?

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Yes pwede na po.

    • @wencyabot7909
      @wencyabot7909 ปีที่แล้ว

      7 sqm po kwarto namin
      8Hp po bilihin aircon dual inverter na lg ? Okay lamg po ba un sa kwarto namin ?

  • @angelohinubania7540
    @angelohinubania7540 2 หลายเดือนก่อน

    ano ba pinakamababa na horsepower inverter para sa maliit na kwarto lang lodz.

    • @j24227
      @j24227 17 วันที่ผ่านมา +1

      0.5 hp

    • @angelohinubania7540
      @angelohinubania7540 17 วันที่ผ่านมา

      @@j24227 thank u lods

  • @7BoGGs
    @7BoGGs 2 ปีที่แล้ว +1

    kung ang recommend ng surveyor sa room namin ay 1hp lang, pwedi ba bumili ako ng 1.5hp?

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว +1

      Kung nagsurvey po sila at nag compute ng heatload ay sundin nyo po ang 1hp. Sakto po iyan para sa room nyo. Kung bibili po kayo ng 1.5hp ok lang naman po pero baka mas mapamahal naman po kayo sa kuryente.

    • @7BoGGs
      @7BoGGs 2 ปีที่แล้ว +1

      @@jepokractv5565 salamat po! anong brand you recommend to buy for split type inverter?

    • @jepokractv5565
      @jepokractv5565  2 ปีที่แล้ว +1

      Kung ano po yung may malapit na service center sainyo para madali ang service pag nagkaproblema.

  • @tito_jan
    @tito_jan 2 ปีที่แล้ว +2

    Babyface 😊

  • @trishkhali7361
    @trishkhali7361 ปีที่แล้ว +1

    Sir. Paano po ba magsukat ng roomsize? :)

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      length multiply by width to get square mtrs

  • @abraexploretv9387
    @abraexploretv9387 ปีที่แล้ว +1

    idol pano ba kayo ma contac

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Pm po kayo sa J rey cruz ref and aircon services sa fb page po. Salamat po

  • @jaybongpalaginog2100
    @jaybongpalaginog2100 4 หลายเดือนก่อน +1

    Good morning idol,, bumili kasi ako ng ac 10sqm ang sukat ng room tapos heat load 2-4 person lang talaga,, kaso nabili ko na aircon 1.5hp split full dc ,, ok lang po ba o over capacity po

    • @jepokractv5565
      @jepokractv5565  4 หลายเดือนก่อน

      ok lang naman po kaso medyo mas malakas ka po sa kuryente, mas tipid po sana kung mas maliit. overpower

  • @rayangelodeleon8173
    @rayangelodeleon8173 ปีที่แล้ว +1

    paano po ba mag compute ng load para malaman kung ilang sqmtr..
    yung bahay ko kasi 30sqmtr.
    tapos leless pa po ba ang kitchen at t&b bali papatak lang po ng 24sqmtr. yung lalagyan...
    kaya na po ba sa 2hp split type aircon..
    tapos yung hieght ceilling to floor is 260cm
    salamat sa sagot sir

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Sa technician po na marunong magcompute po. Pwede po kayo magpapunta sa bahay nyo po nakakabitan ng aircon para sakto ang hp.

  • @theresemoneda8854
    @theresemoneda8854 ปีที่แล้ว +1

    sir pa tulong po
    pwede po kaya to 1.5hp nabili kong A/C sukat po ng bahay H: is 4m Lenght: 3.6m Width: 3.5m
    2 adult 1 newborn 1 computer 1 rice cooker soon refrigerator bibile (2 ilaw isang bintana 1 cabinet at BUhos yung bahay expose sa araw gang 4pm) at my isang kama at crib
    Thank you po in advance

    • @jepokractv5565
      @jepokractv5565  ปีที่แล้ว

      Mas ok po kung 2hp, pero kaya din naman po nyan.