RGF Environmental How To Install A HALO LED Air Purifier

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ก.ย. 2024
  • The HALO LED is intended to be installed by qualified professionals only. For purchase and installation of certified RGF products, please contact your local air conditioning contractor today!
    Warranty coverage will be affected, due to improper installation, by a non-qualified technician.

ความคิดเห็น • 61

  • @DV-go9ws
    @DV-go9ws 7 หลายเดือนก่อน +2

    Great video. Awesome that a company actually does this. I as able to complete my self and saved 1000 install fee.

  • @mounirdarwiche6075
    @mounirdarwiche6075 ปีที่แล้ว +11

    If you’ve never used an air filter these are great. th-cam.com/users/postUgkx_dppjvjF8BYEmPSDTcgCUdRsgWYLXNHN I ended up with three after starting out with one. The noise level depends on the 1-3 settings with how hard you want the machine to work. You can also upgrade the filters and get one better for pet hair and smells which is a must have in my home. I noticed the air seemed lighter and easier to breathe when running the machine for the first time. Works great every time. Highly recommended!

  • @brianshimp8299
    @brianshimp8299 ปีที่แล้ว +1

    Please ignore my comment below. I spoke in ignorance. I have since contacted RGF and spoke with the man that designs this system. He informed me that some EAC terminals do not put out proper HZ when first coming on and that can damage the REME. He wants all units installed with the transformer powered all the time and break the low voltage to the REME with an air proving switch or relay. He said if you always use the air proving switch, you won't have confusing different diagrams for your techs. Just get the line voltage right to the transformer and good to go.
    New diagrams may be coming out to replace the current ones.

  • @hdryden7652
    @hdryden7652 2 ปีที่แล้ว +2

    Mike, great video on how to install this device. You made it very simple and including the diagrams was very helpful.

    • @rgfgroup
      @rgfgroup  2 ปีที่แล้ว

      We agree, Mike did a great job explaining the installation thoroughly!

    • @js6159
      @js6159 8 หลายเดือนก่อน

      @@rgfgroup: can I purchase this unit from you? If so, what is the price and warranty? I have read that RGF will not honor warranty claims unless this unit was installed by a licensed contractor. I would install the Rene Halo LED myself since I have done all the electrical and HVAC in two homes I built. I see no way that I would improperly install this. Thanks.

  • @geebo47
    @geebo47 2 ปีที่แล้ว +1

    This Is the Best video for this unit out there, Did surprise me to see myself in it though

  • @charlesmorgan2234
    @charlesmorgan2234 3 หลายเดือนก่อน

    RGF instructions for relay installation all involve switching the primary side of the supplied transformer on and off. It seems to me that a better approach would be to switch the secondary side on and off (leaving the transformer always powered), similar to RGF's instructions for an air sensing switch. For air handlers that control the blower fan via the G terminal (fan control) only, the G and C (common) terminals could be connected to the relay coil terminals, and either of the transformer's secondary wires could switched via the NO (normally open) terminal on the relay.

  • @randsipe224
    @randsipe224 ปีที่แล้ว

    Excellent video with plenty of detail.

  • @StMichealdefendus
    @StMichealdefendus ปีที่แล้ว +8

    How do I connect the power without the air switch? You skipped that

  • @searay260sundeckforsale4
    @searay260sundeckforsale4 2 หลายเดือนก่อน

    Thank you for the video! I was able to install it myself. The supplied rubber hose that came with the air switch is not long enough for both sides (positive and negative) - I only connected the return for now and it works. Question - what is the purpose of connecting both on the air switch - is it mainly for backup?

  • @brianshimp8299
    @brianshimp8299 ปีที่แล้ว +2

    Nice video and what you say works, but when Installing the REME LED to a furnace, it is easier to power the transformer from the EAC terminals on the furnace logic board and plug the 24 volt end of the harness into the unit and you are done. No airflow switch or relay is needed on the furnace installation. The furnace logic board is specifically designed to energize the EAC terminals anytime the blower turns on. Air handlers are different because they do not have EAC terminals. Then either the relay or the airflow switch is needed to install the unit properly.

    • @shanew7361
      @shanew7361 ปีที่แล้ว +1

      Does this work only when the furnace is running, or does this run when the AC is running, too? Mine was installed without tje air sqirxh only runs when furnance us on. Is this normal?

    • @brianshimp8299
      @brianshimp8299 ปีที่แล้ว +1

      @@shanew7361 The REME Halo LED should turn on any time the air is being circulated in the home, both heating and cooling and even just fan on. However, it should not be on 24-7. The REME Halo LED does need to turn off and on in order to clean little brushes that you cannot see that are under the plastic cover on the end in the duct. This happens each time the unit turns on. Brian

    • @shanew7361
      @shanew7361 ปีที่แล้ว +1

      Brian Shimp So my contractor didn't install this properly cheaped out and were lazy. They did not install the air switch kit. Mine only functions when the furnace is running. They are coming out tomorrow to have a look. Suggestions on what to say and ask them? My furnace was replaced in October 2022 along with the Reme. Or does one not need the air switch for it to turn on during AC and heating? I got a Carrier 2 stage 125k btu.

    • @brianshimp8299
      @brianshimp8299 ปีที่แล้ว +2

      @@shanew7361 That Carrier gas furnace has EAC terminals that get 120 volts every time the fan in the furnace turns on. They can put a 120 volt coil relay on those EAC terminals and have the relay cycle the low voltage to the REME or they can install the air proving switch.
      Here are my comments from before that are accurate. If they don't like them, they can call RGF like I did.
      I have contacted RGF and spoke with the man that designs this system. He informed me that some EAC terminals do not put out proper HZ when first coming on and that can damage the REME. He wants all units installed with the transformer powered all the time and break the low voltage to the REME with an air proving switch or relay. He said if you always use the air proving switch, you won't have confusing different diagrams for your techs. Just get the line voltage right to the transformer and good to go.
      Hope it helps to make your case.
      Brian

    • @shanew7361
      @shanew7361 ปีที่แล้ว +1

      @brianshimp8299 Thanks. I screen shotted this information I will share with tech after his assumed diagnosis or lack of knowledge. You never know what shows up nowadays, lol

  • @jeromelinnen3944
    @jeromelinnen3944 ปีที่แล้ว +4

    If you have a modulating furnace is it mandatory to use the air switch or can you connect it to the EAC? if you connect with the EAC do you have to use the relay?

  • @7HEREALDON
    @7HEREALDON 11 หลายเดือนก่อน

    How does the product prevent mold growth in the coils in the handler? Ans and does it help people with MCS? Beautiful work btw

  • @infamous3059
    @infamous3059 2 หลายเดือนก่อน

    Someone, please tell me if you have to use the transformer. I have a Goodman ASPT47D14 HVAC unit and my electrician says that it's not necessary to use the transformer. Do you know if this is true?

  • @thecaliforniaconquestor9485
    @thecaliforniaconquestor9485 7 หลายเดือนก่อน

    My company started selling these in totally buying one for my house.

  • @AndyTanguay
    @AndyTanguay 5 หลายเดือนก่อน

    Does the orientation of the air switch make a difference? In the install manual it seems to be illustrated 180 degrees from this video.

  • @peacefulnaturehaven
    @peacefulnaturehaven 8 หลายเดือนก่อน

    A guy came out and installed one at my house today, but didn’t use a rubber grommet for the air switch hose…just put it through an open hole. Is that going to be a problem?

  • @idealynx
    @idealynx ปีที่แล้ว +2

    Hi Mike, great video! What's the warranty on the unit and will a DIY install void the warranty? Also, is the air switch included?

    • @tommckelveyiii7714
      @tommckelveyiii7714 ปีที่แล้ว

      yes it voids the warranty, no the air switch is not included

  • @antonymozart
    @antonymozart 6 หลายเดือนก่อน

    Installer claiming my brand new device is faulty. Cannot turn on. But also claiming correct inctalation and wiring on his side. How to check device in this case? (Installed without air switch).
    Thanks for help.

  • @keaveny63021
    @keaveny63021 ปีที่แล้ว

    Excellent video!

  • @rekinop
    @rekinop ปีที่แล้ว +2

    How to connect without air sensing switch?? Please help

  • @jordanfaltysek9957
    @jordanfaltysek9957 หลายเดือนก่อน

    If you have 2 systems in your home, do you need 2 halo-leds?

    • @rgfgroup
      @rgfgroup  หลายเดือนก่อน

      Hi Jordan! Yes, you will need one for each system.

  • @unclegowron7262
    @unclegowron7262 ปีที่แล้ว +2

    The red indicator light on mine keeps turning off. Ive removed the unit, put it back in and the red light will come on for a while then go off again. Does this mean the bulb needs replaced or is there another issue?

    • @spidaboi2014
      @spidaboi2014 ปีที่แล้ว

      The problem is that it probably doesn’t have its own transformer or it’s powered directly that will kill them , wire it to the G

  • @MrMilanina
    @MrMilanina ปีที่แล้ว

    Just to keep the air circulating in my house I run the fan every hour for 30 minutes from 7AM to 10PM no matter whether the cooling or heating is on or off.
    Would using Halo LED be an option in such case or I should go with Reme HALO, possibly Zero? Thank you.

  • @sonophotossonophotos2538
    @sonophotossonophotos2538 ปีที่แล้ว

    Reme does the same ?
    The only difference is the bulb?

  • @Evim2020
    @Evim2020 ปีที่แล้ว +1

    Quick question Mike. What would happen if the Halo-LED Barrel Plug gets unplugged? The homeowner installed one of those in the apartment where I live with my family and we've been getting sick often after its installation. The homeowner refuses to uninstall it.

    • @TheNorthsquad
      @TheNorthsquad ปีที่แล้ว

      The UV light isn't what's making you sick, even if it unplugged. Unistalling it would make no difference at all

    • @selwyn13
      @selwyn13 9 หลายเดือนก่อน

      You probably getting those symptoms b/c u have mold which will happen if that UV light is unplugged (assuming it's not hardwired), that outlet isn't working, the breaker for that outlet tripped for whatever reason, if the bulb is burnt out. Shouldn't be the other way around.

  • @kylegilliano281
    @kylegilliano281 ปีที่แล้ว

    can you mount these to duct board securely?

  • @robertpardo4346
    @robertpardo4346 ปีที่แล้ว

    How would you install this using the peanut relay that come with the Reme halo?

  • @mjj1587
    @mjj1587 ปีที่แล้ว

    Any videos / instructions for how to install this on a 240v air handler here in Florida?

    • @briantheguy1
      @briantheguy1 ปีที่แล้ว

      Just use the 240v wire as indicated on the power transformer. Look at the label on the metal transformer box.

    • @spidaboi2014
      @spidaboi2014 ปีที่แล้ว

      Use the transformer it comes with and step down it ??😅😂

  • @alliekolomiyets8234
    @alliekolomiyets8234 2 ปีที่แล้ว

    We just got our Reme replaced by a technician, this second one seems to not work as well. We can’t really smell ozone as we used to. Is there a setting where we can turn up the setting? Thanks would hate to have to change it out

    • @geebo47
      @geebo47 2 ปีที่แล้ว +1

      The REME LED makes no ozone so you obviously won't smell it.

    • @rgfgroup
      @rgfgroup  2 ปีที่แล้ว

      Hi Allie! Thank you for your inquiry. The REME is not an ozone generator, but I know what you mean. The REME HALO does have an adjustable shroud so you could have your contractor open that up all the way to increase the output.

  • @jesusdisciple7343
    @jesusdisciple7343 ปีที่แล้ว

    If you connected to L1 which is power always on, how would the halo be control with the fan?

    • @jeremymorgan7199
      @jeremymorgan7199 ปีที่แล้ว +1

      The L1 is powering the transformer not the halo. The 24V coming from transformer powers halo but you're breaking the 24 with the air switch. Just like a float switch pretty much

  • @Ehiz001
    @Ehiz001 ปีที่แล้ว

    My technician has just installed the reme halo LED by connecting directly to the circuit board and it keeps it staying on at all times. Is this an incorrect way? And it is close to air filter in the direction of airflow.

    • @rgfgroup
      @rgfgroup  ปีที่แล้ว

      Hi Sammie! Thank you for your inquiry. We recommend that the HALO LED is wired to cycle on and off with the blower. The REME HALO on the other hand is wired to run continuously.

  • @sonophotossonophotos2538
    @sonophotossonophotos2538 ปีที่แล้ว

    Question
    Which one is The Best then.
    Results

  • @sonophotossonophotos2538
    @sonophotossonophotos2538 ปีที่แล้ว

    Hello LED?

  • @dnell6854
    @dnell6854 2 ปีที่แล้ว

    What the heck ,you need to go back and review this video some things doesn’t add up

    • @rgfgroup
      @rgfgroup  2 ปีที่แล้ว

      Hi Dnell68! We'd love to clarify any questions you might have.

  • @justinsmith4839
    @justinsmith4839 3 หลายเดือนก่อน

    I do not understand why you need a air switch when this the fan come on the halo comes on pretty simple.