TROCA DE PAINEL BOMBA SUBMERSAS.

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 พ.ย. 2024

ความคิดเห็น • 36

  • @fagner8931
    @fagner8931 2 ปีที่แล้ว

    Bom dia ensina a trocar capacitor de bomba de poço artesiano de forma correta

  • @leonardoramos8752
    @leonardoramos8752 2 ปีที่แล้ว

    Ola amigo , posso colocar o control box de outra marca , porém mesma especificação no lugar do antigo ? Quero colocar uma boia automática/manual , porém o contro box da minha bomba não tem essa opção.

  • @brenoramos1347
    @brenoramos1347 3 ปีที่แล้ว +1

    Se ligar os cabos invertidos tem algum problema?

  • @fernandobeltrao9114
    @fernandobeltrao9114 2 หลายเดือนก่อน

    Qual a distância eu posso instalar o control box da bomba?

  • @mizaeleletronicareal
    @mizaeleletronicareal 3 ปีที่แล้ว +1

    Mizael eletrônica real paulista pe lingado no canal valeu irmão

  • @2008wanderley
    @2008wanderley 3 ปีที่แล้ว

    Boa tarde amigo fassa as amedas mais longe uma da outra que fica melhor

  • @motoragames696
    @motoragames696 3 ปีที่แล้ว

    Rapaz to com problema aqui ja testei a bomba e ela não ta queimada e a energia aqui e bifasico entra no painel bifasico ai sai 3 pernas com faze esse capacitor transfoma energia bi para tri

  • @estmaceletrica7979
    @estmaceletrica7979 3 ปีที่แล้ว +1

    Muito bom

  • @valterdezze1785
    @valterdezze1785 3 ปีที่แล้ว

    Vc substituiu o fio fino pelo grosso. Qual a medida do fio q vc colocou? Obg

    •  3 ปีที่แล้ว +1

      4mm

    • @valterdezze1785
      @valterdezze1785 3 ปีที่แล้ว +1

      Valeu! OK 👍👍

  • @antoniodepaula1564
    @antoniodepaula1564 2 ปีที่แล้ว

    Você tem vídeos ensinado monta painel da bomba

  • @renatoramos3623
    @renatoramos3623 3 ปีที่แล้ว

    Olá amigo!
    Estou com um painel de bomba submersa para instalar e fiquei na dúvida em relação as fases a utilizar.
    Meu painel é da marca EBARA, monofásico, 220v, 3hp, 3 fios.
    No esquema de ligacão dele indica a utilização de uma fase e neutro. Mas aqui a fase é 110v, e o painel é 220v. Nesse caso posso utilizar duas fazes de 110v cada?

    •  3 ปีที่แล้ว +1

      Se na sua região fase e neutro for 220V você vai usar fase e neutro, agora se for fase e fase 220V você vai usar as duas fase , e que tem lugares que fase e neutro e 220 e outros lugares que fase e fase e 220v.

    • @renatoramos3623
      @renatoramos3623 3 ปีที่แล้ว

      @ mto obrigado amigo!
      Aqui na minha região fase e fase é 220v. Vou fazer assim

    • @roccodavis4775
      @roccodavis4775 3 ปีที่แล้ว

      i dont mean to be offtopic but does any of you know a way to get back into an instagram account??
      I stupidly forgot the password. I appreciate any tips you can offer me.

    • @kanedillon4107
      @kanedillon4107 3 ปีที่แล้ว

      @Rocco Davis Instablaster =)

    • @roccodavis4775
      @roccodavis4775 3 ปีที่แล้ว

      @Kane Dillon I really appreciate your reply. I got to the site through google and I'm in the hacking process now.
      Looks like it's gonna take a while so I will get back to you later when my account password hopefully is recovered.

  • @icarobezerra9500
    @icarobezerra9500 4 ปีที่แล้ว +1

    O control box, onde posso encontrar para compra? Para bomba de 0,5 cv. Sou de Manaus

    •  4 ปีที่แล้ว

      Se nao tiver na sua cidade, vc so vai comsegui pela internet.

  • @maxhenrique9982
    @maxhenrique9982 2 ปีที่แล้ว

    Esse painel pode ficar ligando e desligando ele quando quiser? Ou tem que deixar ligado direto?

    •  2 ปีที่แล้ว +1

      Pode desligar quando quiser.

  • @antoniodepaula1564
    @antoniodepaula1564 2 ปีที่แล้ว

    Como liga o capacitor da bomba

  • @CarlosOliveira-yt4hk
    @CarlosOliveira-yt4hk 3 ปีที่แล้ว

    Minha energia não tocou, não tava 220 lá na tomada da bomba oq eu faço?

  • @reginaldojose833
    @reginaldojose833 4 ปีที่แล้ว

    Olá, é necessário o aterramento? Causaria algum problema na bomba?

    •  4 ปีที่แล้ว

      Se possivel faça o aterramento, se tiver uma descarga atmosférica ( raios) não ira pra sua bomba e sim para o eterramento.

    • @reginaldojose833
      @reginaldojose833 4 ปีที่แล้ว

      @ O que está acontecendo é que uma bomba de 0,5cv está dando uma amperagem de 19A e como isso o térmico desarma, isso quando a bomba nem parte. Bomba da marca intech :(

    •  4 ปีที่แล้ว

      Peguei uma bomba de 2 CV com esse tipo de situação, fiquei quase 2 dias pra resolver o problema, no poço a bomba ligava e desarmava, a corrente chegava a 32A, mas quando eu testava na minha casa ela funcionava normal, quando cheguei na casa do cliente liguei ela direto no padrão de entrada e funcionou, tive que refazer a instalacao elétrica ate a bomba e funcionou.

    • @leandrosantana8479
      @leandrosantana8479 3 ปีที่แล้ว

      @@reginaldojose833, É bom dá uma olhada na bomba, ela pode está trabalhando a seco. 0,5 cv não é para atingir essa amperagem. A principal funcionalidade o Relé é essa, evitar que a bomba queime por trabalhar a seco.

    • @leandrosantana8479
      @leandrosantana8479 3 ปีที่แล้ว

      @ Nesse caso, 2Cv desarmando e ligando direto no padrão de entrada funcionando, pela sua explicação, o cabos estavam dimensionados errados. Parabéns por compartilhar suas experiências.

  • @jairoeduardodamasceno4278
    @jairoeduardodamasceno4278 4 ปีที่แล้ว +1

    Manda aí o diagrama deste modelo que instalou

  • @rogerioserafimdelima1436
    @rogerioserafimdelima1436 4 ปีที่แล้ว

    Boa tarde como liga uma chave boia no contro Box bomba caneta monofásicos

    •  4 ปีที่แล้ว +1

      Vc coloca os fios da boia no borne da control box, onde esta escrito bóia, e em seguida seleciona o botão da control box na opção automatico.

  • @giliardsouza551
    @giliardsouza551 4 ปีที่แล้ว

    A minha tá jogando sem força oq pode ser